Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 2 4 136 4TH BLOCK LINGA REDDY MANSION OPP TARBUND SECUNDERABD TARBUND SECUNDERABAD TELANGANA 500009 | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.7 L+₹77,058 (3.22%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-AOC Not being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT HAVING REQUISITE WORK CATEGORY i.e. c(i) |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS / REPLACEMENT OF UNSERVCEABLE SPARES OF AC PLANTS UNDER AGE E/M NO-II OF GE (UTILITY) SECUNDERABAD
2022_MES_505380_1
GE(U)/SEC/TOKEN/65 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER UTILITY SECUNDERABAD
₹60,000
Yes
30 Aug 2022
2 Feb 2022
7 Mar 2022
2 Feb 2022
28 Feb 2022
16 Feb 2022
60 days
Amount
M&L for Blue star 2x40 TR+1x40TR Scroll compressor chiller type air cooled AC Plant inspection and fault rectification carried out by Manufacturer Engineer for releasing out locking setting the programming for proper functioning of AC plant and to rectify other minor/major problems, including Re-programming & rectify faults occured as and when, with all necessary tools and machines and other major problem & faults (faults either software problem or hard ware) including providing new software if software not working properly with all necessary tools and machines.
All as per Item No.1 here in before but for Hitachi 4 x 8.5 TR + 2 x 8.5TR ductable type air cooled packaged AC Plant Note for Item No. 1 and 2 :- (i) Transportation & loading charge & hiring charge of machines and equipments are deemed to be included in quoted rates (ii) Material shall be mesured & paid separately under relavent items. (iii) The service Engineer shall be from OEM only.
Evacuation of gas from each Chiller Unit of 8.5 TR package type System/central type AC plant and leak testing the system by giving the dry nitrogen by separating the low side /high side of the system and arresting the leaks including replacement of Teflon seating of the all refrigerant line, suction/discharge valves of compressor, gland package of all angle valves flaring off and charging complete all as directed by Engr-in-charge. Note :- Quoted rate shall be inclusive for filling of cost of nitrogen gas.
All as per Item No. 3 here in before but for 40 TR(each chiller unit) of AC Plant Chilled system.E16
S&F of 'V' Belts ISI marked suitable for existing one of the following size A-32 to 34.
All as per Item No. 5 here in before but for size B-84
Supply and charging the Refrigerant Gas R- 410A complete all as directed by Engr-in-charge.
Supply and charging the Refrigerant Gas R- 407C complete all as directed by Engr-in-charge.
Draining out the old compressor oil from various compressors and supplying, filling/ top up of compressor oil of Freezol-68/ freezol F-57 complete all as directed by Engineer-in-charge.
Servicing and cleaning of Double skin AHU(including blower & existing heat bank strip) unit of capacity 4000CFM including Cleaning of the evaporating coil (AHU coil) with cleaning Acid forced feed method to remove the unwanted dust particles formed on the coil and in AHU unit, cleaning of the filter, greasing to the AHU unit bearing of the structure, expansion valve etc and testing complete all as directed by Engineer-in-charge.
All as per Item No. 10 here in before but for AHU Capacity 12800CFM.
All as per Item No. 10 here in before but for AHU Capacity 6000CFM.
Renewal of unserviceable condenser safety valve 15mm to 20mm, withstand pressure 300-800 PSI complete all as directed by Engr-in-charge
S&F in Liquid line Filter Dryer suitable for 8.5 TR capacity Compressor unit complete all as directed by Engr- in -Charge.
All as per Item No. 14 here in before but for 40 TR capacity Compressor unit complete all as directed by Engr- in -Charge. Make for item Nos 14 & 15 : Emerson/Jhonson/Honewell or equivalent as approved by GE.
Disconnecting the Motor of condenser / Blower/ Chiller/ AHU units from installed position, disconnecting the pump and rewinding the same with super enamelled copper wire of same gauge and turns as per existing, replacement of wornout Bearings fixing back on its original exisiting position, testing and commissioning complete for the following capacities :- Note : Transportation charges also included in quoted rate (i) up to 7.5 hp capacity
All as per Item No. 16 here in before but above 7.5hp to 15hp
Renwal/Replacement of electronic star delta timer along with LED incations,including talking down old one complete all as directed by Engr-in-Charge. Make : GIC/SEIMENS/Minilec or equivalent as approved by GE.
Renwal/Replacement of single phase preventor with following LED indications 3- phase healthy -ON, phase -loss -OFF including talking down old one complete all as directed by Engr-in-Charge. Make : GIC/SEIMENS/Minilec or equivalent as approved by GE.
Taking out unserviceable MS pipe and Supply, erection, testing & commissioning of New 125mm(5") dia bore, mild steel chilled water piping of class'C",cut to required lenth and installed with welded joints,inclduing all necessary fittings such eblows,tees,bends,reducers,flanges and necessary civil/MS supports,pressure testing etc complete.chilled water pipe insulation shall be with 32mm thich nitrile rubber covered with vapour barrier and finished with 26G alumiunium clading complete all as directed by Engr-in-Charge.
All as per Item No. 20 here in before but for size 75mm(3") dia bore complete all as directed by Engr-in-Charge.
All as per Item No. 20 here in before but for size 40mm(1.25") dia bore complete all as directed by Engr-in-Charge. Make for item No.20 to 22: TATA/Jindal or equivalent as approved by GE.
Taking out unserviceable butterfly vlave and Supply,erection,testing &commissioning of New 75mm(3") dia bore, butter fly valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Advance/Castle or equivalent as approved by GE.
Taking out unserviceable Globe valve and Supply,erection,testing &commissioning of New 75mm(3") dia bore, globe valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Advance/Castle or equivalent as approved by GE.
Taking out unserviceable NRV and Supply,erection,testing &commissioning of New 75 mm(3") dia bore ,Non -return valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by ENgr-in-Charge. Make: Advance/Audco/Inter valves/Sant
Taking out unserviceable Y-strainer and Supply,erection,testing &commissioning of New 75 mm(3") dia bore, Y-strainer PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed including taking down old u/s one complete all as directed by ENgr-in-Charge. Make : ant/Advance/Emerald or equivalent as approved by GE.
Suuply, test, install & commissioning of the pressure guage suiatble for existing one as per latest engineering standards and spcifications,fixed with necessary insulations(matching to existing) as required including taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make: H Guru/Sant/Waree or equivalent as approved by GE.
Suuply, test, install & commissioning of the Thermo meter suitable for exisitng one as per latest engineering standards and spcifications,fixed with necessary insulations(matching to existing) as required including taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make : H Gru/Sant/Ware or equivalent as approved by GE.
Supply, install, test & commissioning of the water flow swtich suitable for existing one as per latest enginnering stanards and specifications ,fixied with necessary insualtion(matching to existing) as required including taking down old u/s one complete all as directed by Engr-In-Chrarge. Make: Honey well/Johnsons/Siemens or equivalent as approved by GE.
Supply, test, install & commissioning of the Auto air vent of suitable size 15mm dia to 20mm dia as per latest engineering standards and specifications,fixed with necessary insulation(matching to exisitng) as required inclduing taking down old u/s one comeplete all as directed by Engr-In-Charge. Make:Amtrol/Anergy/flammcotraders or equivalent as approved by GE.
Supply, test, install & commissioning of the rubber bellow connections for pumps as per latest engineering standards and specifications,fixed with necessary insulation(matching to exisitng) as required inclduing taking down old u/s one comeplete all as directed by Engr-In-Charge. Make: Cori/Easyflex or equivalent as approved by GE.
Supply, install, test & commissioning of Micro bubbler Air & Dirt separators,with matching flanges bolts,Nuts,gaskets,insulation,vlaves and airvent for the size of 150mm dia PN 1.0 including taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make: Amtrol/Anergy/flammcotraders or equivalent as approved by GE.
Supply, install, testing and commissioning Suction line with fittings of hard copper piping for condensor units with isulation of 6mm thick nitrile rubber pre formed sections includingsupporting fixtures and accessories etc suitable for Hitache 8.5TR packaged type unit complete all as specified and directed by Engr-in-Charge.
Supply, install, testing and commissioning liquid line with fittings of hard copper piping for condensor units with isulation of 6mm thick nitrile rubber pre formed sections includingsupporting fixtures and accessories etc suitable for Hitache 8.5TR packaged type unit complete all as specified and directed by Engr-in-Charge.
Supply, insulation, test and commissioning of under deck insulation for exposed roof of 23mm thickness Class 'O' grade XLPE material all as specified and as directed by Engr-In-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of OT unit, MH complete all as directed by Engr-in-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of ICU unit, MH complete all as directed by Engr-in-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of Air cooled plant, MCEME auditorium complete all as directed by Engr-in-Charge
S&F of 3 pole power contactor MNX-12,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
S&F of 3 pole power contactor MNX-18,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
S&F of 3 pole power contactor MNX-25,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
S&F of Add on block MNX-A1 for 3 pole power contactor suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
S&F of Add on block MNX-A2 for 3 pole power contactor suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
S&F of DOL MN2 -Thermal overload relay suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
S&F of analog timer suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make: L&T/GIC/Schnieder/Siemens
S&F Refrigerent gas R - 22 for AC Plant complete all as specified and directed.
S&F of 3 pole MCB,40-63amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens or equivalent as approved by GE.
S&F of 3 pole MCB,6-32 amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens or equivalent as approved by GE.
S&F of 3 pole power contactor CHINT NC1-4011,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make:CHINT NC1-4011 or its equivalent in L&T/Siemens/Schneider as approved by GE.
Supply & fixing of 3 pole Air break (power) contactor suitable 10-0A,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make:Seimens -3TS30 10E or its equivalent in L&T/Schneider as approved by GE.
Taking out unserviceable chilled water inlet sensor & supply and fixing of new chilled water sensor complete all as directed by Engr-in-Charge.
Taking out unserviceable chilled water outlet sensor & supply and fixing of new chilled water sensor complete all as directed by Engr-in-Charge.
Disconnecting and taking out unserviceable oil tight limit swtich and S& new Oil tight limit switch complete all as directed by Engr-in-Charge. Make:TEKMEC/Honeywell or equivalent as approved by GE.
S&F main switch with HRC fuses of 3 pole with neutral 160A capacity,50Hz,3-Ph, front handle operated including necessary cable connections, nuts bolts complete all as directed by Engr-in-charge. Make: Seimens/L&T/Schneider/ABB
Renwal/Replacement to existing unserviceable PCB board(mother board) suitable for exisitng Blue star scroll compressor(compatiable for 4 -compressors air cooled DLT type) chiller plant of capacity 40 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engr-in-charge. Note : Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Renwal/Replacement to existing unserviceable Display PCB board suitable for existing Blue star scroll compressor(compatiable for 4 -compressors air cooled DLT type) chiller plant of capacity 40 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engr-in-charge. Note : Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Taking out unserviceable balancing vlave and Supply, erection, testing & commissioning of New 75mm(3") dia bore, balancing valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Advance/Castle or equivalent as approved by GE.
Taking out unserviceable 3-way mixing valve and Supply, erection, testing & commissioning of New 62.5 mm(2.5") dia bore, 3-way mixing valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Honeywell/Jhonsons/Siemens/rapid control
Disconnecting & Taking out un servicebale MCCB and S&F of new MCCB 400 Amps, 36 KA, 4 pole, 415 volts, 50 HZ adjustable settings,thermal,magnetic release type suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new MCCB 100 Amps, 25 KA, 3pole, 415 volts, 50 HZ , suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new MCCB 100 Amps, 25 KA, 4pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new S&F MCCB 160 Amps, 36 KA, 3 pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new S&F MCCB 200 Amps, 25 KA, 4 pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge. Make for item Nos.59 to 63: L&T/Siemens/Schnieder/ABB/Legrand
Taking out old u/s rotary handle and supply & fixing of new S&F of Exended ROM(Rotary handle) kit suitable for existing one inclding neccesary connections and taking out old u/s one complete all as directed by Engr-in-Charge Make :L&T/Siemens/Schnieder/ABB/Legrand
Supply & fixing of 4 pole power contactor MCX-12,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make: L&T/Schnieder/Siemens as approved by GE.
Taking out unserviceable VFD drive from its existing position and Supply,test, install & commissioning of VFD drive of capacity 11kW/15Hp,415volts,3-Ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engr-in-Charge. Make: Danfoss VLT micro drive- 132F0058 or its techno commerical equivalent in L&T/Yaskawa/Fuzi as approved by GE.
Taking out unserviceable VFD drive from its existing position and Supply,test, install & commissioning of VFD drive of capacity 3.7kW/5Hp,415volts,3-Ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engr-in-Charge. Make: Danfoss VLT micro drive- 132F0026 or its techno commerical equivalent in L&T/Schnieder/Yaskawa/Fuzi as approved by GE.
Taking out unserviceable VVVF drive from its existing position and Supply,test, install & commissioning of VVVF drive of capacity 3.7kW/5Hp,415volts,3-ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engr-in-Charge. Make: L&T Cx 2000-LTVF-C40010BAA or its techno commerical equivalent in L&T/Yaskawa/Fuzi as approved by GE. Note for item No 66 to 68 : Installation & commissioning shall be done by OEM only.
REPAIRS TO DGQA 12.50 TR AC Plant SM No 198186
S&F Thermostatic Switch operated on 230 Volts AC Supply suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F Coil for loading and un-loading solinoid valve suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F Main bearing non end driving for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Main bearing driving end for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Connecting rods for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Discharge reed with springs (set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Suction reed with springs (Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Piston ring( Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Cylinder liner ( Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Piston for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Gasket set for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Gudgeon pin with bush for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F shaft seal assembly including carbon ring suitable for make ACCEL, Compressor of capacity SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Thermostatic Expansion Valve suitable for12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F Solinoid valve of existing size and model suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F in replacement of crank shaft assembly suitable for 12.5 Ton AC Plant
S&F spare parts suitable to RO Plants of capacity 500 LPH-02 Nos including taking down old unserviceable spare parts complete all as specified and directed
Filter for RO Plant 500 LPH
Carbon Sand
40x40 Membrane
Flow meter
Pressure guage
PTMT Ball Valve
Pump NRV of suitable size
UV System
PVC Pipe
Disconnection RAW water feed pump 0.5HP and re-winding,including replacement of unserviceable bearings of suitable size and re-assembling the motor including installation complete all as specified and directed.
Disconnecting High pressure pump 500 LPH and re-winding, including replacement of unserviceable bearings of suitable size and re-assmbling the motor including instalation complete all as specified and directed.
Mebrane housing for 40x40 RO membranes.
Taking out old blocked GI tubing with all accessories such as Bend, Elbow, Tees, Nipples, sockets, unions, reducers from any position (in trenches/ floors/ walls) and cleaning of the same and refixing in original position with necessry new GI fittings (ISI Marked)(if required) heavy grade and making good with existing surface including if necessary civil works like Brick, cement work etc., for the following dia of pipes complete all as directed by Engineer-in-charge :-
15 mm dia
20 mm dia
50 mm dia
Taking out old unserviceable GI pipe line and supply and fixing/ laying GI tubing medium grade laid in trenches/ floors or fixed to walls including necessary GI fittings such as bends, elbows, nipple, sockets, unions, reducers, tees etc and making good with existing surface following dia of pipes complete all as directed by Engineer-in-Charge :- Make of GI pipes :- TATA / JINDAL / ZENITH as approved by GE. Note:(i) The rates deemed to be inclusive of GI fittings & fixing/laying of pipe. (ii) Earth work shall be measured & paid separately under relevant items.
15 mm dia
20 mm dia
25mm dia
50 mm dia
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed by Engr-in-Charge.
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed by Engr-in-Charge
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed by Engr-in-Charge.
S&F GI stop valves 20mm dia,cast copper alloy,screwed down,high pressure,with cruth or butterfly handle,screwed both ends including taking down old unserviceable one complete all as specified and directed by Engr-in-charge. Make : Zoloto/Hindware/Zenith as approved by GE.
S&F GI stop valves 15mm dia,cast copper alloy,screwed down,high pressure,with cruth or butterfly handle,screwed both ends including taking down old unserviceable one complete all as specified and directed by Engr-in-charge. Make : Zoloto/Hindware/Zenith as approved by GE.
Taking out water sample in clean container and getting the same tested from the “Department of Water and Waste Water Examiner, Institute of Preventive Medicine, Narayanaguda, Hyderabad” or “Any Govt Lab” for chemical tests complete all as directed by Engr-in-Charge.
Taking out water sample in clean sterilised container and getting the same tested from the “Department of Water and Waste Water Examiner, Institute of Preventive Medicine, Narayanaguda, Hyderabad” or “Any Govt Lab” for bacterioligical tests complete all as directed by Engr-in-Charge Note for item No 78 & 79 :- Sample water shall be taken from various places of MH and adjoing area under AGE EM-II(U) complete all as directed by Engr-in-Charge .
S&F Manifold Wall Needle pins and brass washer including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F High Pressure MOX Regulator including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F High Pressure oxygen tail pipe of stainless steel including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F Oxygen outlets of double lock front mounted including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F Oxygen flow meters including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F of 22mm dia copper pipe including all necessary fittings nuts bolts and clamps for manifold system including taking down old unservceable one complete all as specified and directed.
S&F of 15mm dia copper pipe including all necessary fittings nuts bolts and clamps for manifold system including taking down old unserviceable one complete all as specified and directed.
Repair/Replacement of ward vacum unit with connected accessories including taking down old unserviceable one complete all as specified and directed.
Repair/Replacement of theatre vacum unit with connected accessories including taking down old unservceable one complete all as specified and directed.
Repair/replacement of adayate valve of size 15mm perole type incl necessary fittings including taking down old unservceable one complete all as specified and directed
S&F in replacement of following spare parts suitable to Oil fired incinerator capacity 60 Kg/ Hrs automatic waste feeding system fuel tank including taking down old unserviceable spare parts complete as under
M&L for Diesel Mono block fully automatic burners of Cat part No LO -20 including necessary spare ie, Sequence control, Ignition coil, transformer including necessary accessories. Make : Alfa Therm or its techno commercial equivalent make approve by GE.
M&L descaling of Primary Chamber 800 Degree Centigrade + 50 Degree Centigrade by Hydro chloric acid 33% concentration till the scaling is removed and cleaning of the chamber with fresh water.
M&L descaling of Secondary Chamber 1050 Degree Centigrade + 50 Degree Centigrade by Hydro chloric acid 33% concentration till the scaling is removed and cleaning of the chamber with fresh water.
M&L descaling of Secondary Chamber- static solid hearth mild cleaning by new technology method of the chamber with fresh water.
Repair & Replacement and servicing of automatic through hydraulic Ram pusher, hydraulic power pack.
Dismantling/Removing of oil fired incinerator Ventury Scribbing System ID Fan winding from motor, re-winding and Re-assembling the original position
Dismantling/Removing of FD Fan of Oil fired incinerator winding from motor, re-winding and Re-assembling the original position
M&L labour for cleaning of Air cooled AC plant of capacity 40 to 50TR Exahust Fans along with copper/tinted copper/Aluminum fins/coils along with suitable liquid chemical and water till desired effectiveness of cooling is achieved for satisfactory completion of job including all misc materials complete all as directed Engr-in-Charge,
S&F of 9mm dia copper pipe including all necessary fittings nuts bolts and clamps for manifold system including taking down old unserviceable one complete all as specified and directed.
Supply, test, install & commissioning of 6'x8' laminar flow terminal filter units for OT being made of CRCA/Pre insulated panel material suitable for fixing HEPA filters including HEPA filter, perforated stainless steel sheet in the bottom suitable provision for OT light to be supported being part of the module including taking down old u/s one complete all as directed by Engr-in-Charge. Make: Laminar flow/Sagarair or equivalent as approved by GE, Make of HEPA: AAF/Fudenburg/Camfil or equivalent as approved by GE.
S&F 12V 48AH maintenance free battery suitable for UPS System complete including taking down of old unseriveable one and replacement of existing connections for 30 Nos of batteries of UPS System in series connection by new connectors of necessary size of copper cable / strips specified by Engineer-in-Charge by means of new nut and bolts etc. and connecting UPS System to existing panel board and Panel board to Building distribution board by 10Sqmm Copper cable all as specified and directed by Engineer-in-Charge Make:- AMARON/EXIDE/EXPRESS/CANON
M&L labour for servicing of 15 KVA UPS by Visual inspection of the battery set and UPS system, connected mains cables, battery cables, distribution boards and the external maintenance bypass switch, Battery terminal connections will be inspected and tightened and re-torqued, alarm and system logs are downloaded and inspected to see how the UPS has performed, Internal components are inspected for age, wear and tear and cleanliness, consumable items like fans and AC and DC capacitors are inspected and replaced according to their replacement programs, checks are made for corrosion in extreme environments that can see dust build up or chemical or salt erosion, Thermal checks may be made using thermal imaging cameras which are used to find hot-spots in the UPS, batteries, cabling, distribution and LV switchgear connected to the UPS system, electrical measurements are taken from the front panel LCD to identify input and output performance per phase complete all as directed by Engr-In-Charge.
All as per Item No. 95 here in before but for 80KVA UPS complete all as directed by Engr-in-Charge.
Supply and drawn sub main wiring with four runs of 4 Sq mm single core PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through and including non metalic PVC rigid conduit accessories surface type on walls, floors etc including two runs of 4.0 Sqmm PVC insulated copper conductor for earth continuity wire all as specified. Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only.
All as per Item No. 97 here in before but for sub main wiring with four runs of 6 Sq mm and two runs of 4.0 Sqmm single core copper conductor for earth continuity all as specified. Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only
All as per Item No. 97 here in before but for sub main wiring with four runs of 10 Sq mm and two runs of 4.0 Sqmm single core copper conductor for earth continuity all as specified. Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only.
S&F MCCB box made of sheet of suitable size Powder coated Suitable for fixing at Pole / wall including two set of clamps comprising with the following :- (i) MCCB 63 Amps 16 KA TP WITH BOTH SIDE SPREADER LINK.
S&F MCCB box made of sheet of suitable size Powder coated Suitable for fixing at Pole / wall including two set of clamps comprising with the following :- (i) MCCB 100 Amps 16 KA TP WITH BOTH SIDE SPREADER LINK.
S&F MCB box made of sheet of suitable size Powder coated Suitable for fixing on wall including two set of clamps comprising with the following :- (i) MCB 32 Amps 10 KA TPN WITH BOTH SIDE SPREADER LINK.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia (THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification. GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC 1:2:4, B1 cover of 300 x 300 mm complete all as specified and directed. Make : ASHLOK / INDELEC/JMV /TERCEL.
M&L for painting of chiller units of OT including basement, suporting channels etc., with suitable colour coding by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of chiller units of ICU including basement, suporting channels etc., with suitable colour coding by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of Squirrel cage induction motors upto 10 HP capacity including basement, suporting channels, connecting pipe lines etc., with suitable colour coding by using synthetic enamelled paint first grade after scrapping /cleaning
Supply of Rubber mat ISI marked of size 1mX2mX20mm
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with necessary frame removable prepared by MS corss arm of required shape and size specified by Engineer - In- Charge.
M&L for replacement of existing base frame of cooling tower for DGQA AC Plant by removing existing connections to cooling tower, removing of existing rusted base frame, fixing of new base frame on existing plinth by the means of PCC, nut bolt etc, painting with two coats for base frame and reconnecting of all connections of cooling tower as per existing all as specified and directed by Engineer-in-Charge. Note:- Rate quoted deemed to be inclusive of all necessary arrangements for removing and reconnecting of existing cooling tower.
Supply, Install, Testing & Commissioning of wall mounted Indoor type totally enclosed LT panel Board CPRI APPROVED, IP 55 compartmentalised design, dust and varmin proof of suitable size suitable for 440 Volt 3 phase 4 wire system made out of 2.0mm thick CRCA sheet and built upon regid frame work having front hinged doors with neoprene rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be Epoxy Powdwer Coated and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom and TOP. The Panel shall be emmbeded with 40 x 4 mm MS Angle Iron frame a complete all as specified and directed by Engr in charge.
Universal refrigeration and Engineering Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .