Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-Due to Non submission of EMD. |
Tender Value
Refer Docs
EMD Value
₹3.9 L
Closing Date
7 Jul 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Capital Division
Office of the Executive Engineer Capital Division A PWD AP Itanagar
Construction of RCC Bridge over Chandan Nagar Nallah between Industry colony and F and D sector Itanagar in Papumpare District
2022_PWDAP_796_1
CD-A/W-3/6A/2022-23/e-T-03
Open Tender
Civil Works
Item Rate
365 days
Itanagar
Not More then 2 work in hand
2 documents required · 2 mandatory
₹1,000
EE CD-A PWD Itanagar
₹3.9 L
Yes
Itanagar
15 Jul 2022
1 Jul 2022
15 Jul 2022
1 Jul 2022
7 Jul 2022
1 Jul 2022
1 Jul 2022 - 4 Jul 2022
4 Jul 2022
90 days
Amount
Sh:- RCC Wall 3 m Height
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M20/ Using Concrete Mixer
Plain/Reinforced Cement Concrete in super-structure complete as per Drawing and Technical Specifications. RCC Grade M20/ Using Concrete Mixer
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (A) Granular material
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
Sh: - RCC Wall 7 m Height
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)(upto 3 m depth)
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M20/ Using Concrete Mixer
Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and Technical Specifications. RCC Grade M20/ Using Concrete Mixer
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications, In Footing and Main Wall
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (A) Granular material
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
SH: Embankment
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
Sh:- CC Pavement
Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade.
Granular Sub-base with Close Graded Material (Table:- 400-2)(Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 )For grading I materials or where ever necessary, 19.23% of GSB may replaced with Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications; A. PCC Grade M15 i.e. (19.23x150)/100=28.845cum @ Rs. 7876.00/cum = Rs. 227183.20/-
Cable Duct Across the Road. Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.(Single row for one utility services)
Cement Concrete Pavement : Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )(Rate is exclusive of cement concrete & transportation)
Sh:- CC Drain
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)Ordinary Soil up to 3 m depth
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC Grade M20
Sh:- Culvert
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. Grade M15
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M20 Height upto 5m
Supplying fitting andPlacing HYSD bar reinforcement in super structure complete as per drawing and technical specifications
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification Granular material
Sh:- Boundary Wall
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M20/ Using Concrete Mixer
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
Centering and shuttering including strutting,proppering etc and removal of frame works a. Foundation footing basement of column etc
Centering and shuttering including strutting,proppering etc and removal of frame works d. Lintels, beams, girders, bressumers and cantilevers etc.
Centering and shuttering including strutting,proppering etc and removal of frame works e. Column, pillars, posts and struts etc.
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications, In Footing and Main Wall
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
White washing with whiting on new work (three or more coats) to give even shade.
Providing and fixing Angle Iron Post of Section 45x 45x6mm
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Providing and fixing of Barbed wire
M/s M Taying Enterprises
stage.html
html • 0.02 MB
finance_899.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .