| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹82.7 L+₹1.5 L (1.80%)Rejected-AOC 80 G T ROAD FEROZEPUR CANTT PB | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹86.9 L+₹5.7 L (6.99%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹87.5 L+₹6.3 L (7.71%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹87.9 L+₹6.7 L (8.21%)Rejected-AOC BAZAR RAM SUKH DASS FEROZEPUR CITY 152002 | FIROZEPUR | PUNJAB | 152002 | L5 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
12 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
PROVN OF CERTAIN OTM ACCN AT FEROZEPUR CANTT
2020_MES_389975_1
81000/E8
Open Tender
Civil Works
Lump-sum
270 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹1,000
Garrison Engineer (West) Ferozepur Cantt
₹1.5 L
Yes
12 Jan 2021
27 Oct 2020
14 Dec 2020
27 Oct 2020
12 Dec 2020
28 Nov 2020
27 Oct 2020 - 12 Dec 2020
60 days
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 15 to 19 of tender documents. (ii) Item from Srl No. 3.00 to 9.03 of this document shall be Part-XII (Miscellaneous items) of BOQ.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS INCLUDING RETAINING WALL as listed in Schedule 'A' Part-I brought forward from serial page No. 20(R).
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 21.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 22(R).
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 24.
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND PCC HARDSTANDING WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 25.
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 26(R).
Lump sum price worked out by the contractor for CATTLE FENCING WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 28(R).
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 30.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 31.
Lump sum price worked out by the contractor for LIGHTENING ARRESTER & PROTECTION WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 32.
Lump sum price worked out by the contractor for AIR CONDITIONING WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 33.
INTERNAL ELECTRIFICATION WORKS
Material and labour for concealed point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLS PVC insulated multi-stranded copper conductor in and including heavy duty PVC conduit pipe (ISI marked) including fittings & accessories including MS concealed terminal boxes with 2.0 mm thick plastic laminated bakelite (Hylum) sheet top cover for mounting switch socket etc including 1.5 sqmm FRLS PVC copper conductor multi-stranded as earth wire connected to the common earth dolly as specified for one light point/fan point/bell point controlled by one switch,socket,fan regulator etc complete all as specified and directed.
All as per item No. 3.01 above but one three pin socket outlet 5 Amp on same board.
All as per item No. 3.01 above but one three pin socket outlet 5 Amp on independent board.
All as per item No. 3.01 above but with 2.5 sqmm cable and 2.5 sqmm copper conductor as earth wire for 3 pin, 15 Amps socket outlet complete.
Supply and fixing batten holder insulated body including LED lamp 10 W 220-240 volts, 6500K, B-22 base cap complete all as specified and directed.
Supply and fixing ceiling fan 1200mm sweep BEE 5 star rated ISI marked with complete fitting including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector including GI pipe down rod of suitable dia 450 mm long all as specified and directed.
Supply and fixing exhaust fan heavy duty steel body with louvers complete of 300mm size with bolts,nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified. Note: Cost of opening in wall and grouting of mild steel work shall be deemed included in the lump sum cost of the building.
Supply and fixing for energy saving tube light luminaires with diffuser LED comprising with CRCA MS box and for fit 18 to 20 watt (max) of 1200mm length retro fit tube rod having thermally conductive material heat sink, lumen output 2100 lumens (min) 6500K, power factor more than 0.95, IP 20 class-I protection with inbuilt LED driver surge protection device, operative on 140-270 volts AC supply complete pre-wired, connection and testing complete all as specified and directed.
Supply and fixing MCB, single pole 240 volts, capacity 6 - 32 Amps, C series 50 Hz, 10 KA complete all as specified and directed.
Supply and fixing for MCB, SPN 240 volts, capacity 32/40 Amps, C series 50 Hz, 10 KA complete all as specified and directed.
Supply and fixing for MCB, TPN 415 volts, capacity 100 Amps, C series 50 Hz, 10 KA complete all as specified and directed.
Supply and fixing energy efficient aesthetically designed 2x2 LED, IP-55 flat panel for ceiling mounting which provides soft light and glare free symmetrical illumination environment friendly LED light for celling illumination as per national lighting code (SP 72 : 2010) by using security light of less than or equal to 34W (total input power) CCT 5000-5700K, CRI-67PF>0.95, operating performance temp-10 degree centigrade +45 degree centigrade LED mounted fire span 60000 burning hours external storage and over voltage protection device upto 440V alongwith connection 3 core copper flexible cable size-0.75 Sqmm to be provided with weather proof connector complete all as specified and directed
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron medium grade 15mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-2 & RCC cover in M-20 (Design mix) and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1 m away from the outer edge of PCC chamber. (ii) GI earth wire upto main board is included in this item. (iii) Water pipe shall be provided in slanting position.
Supply and fixing sub main wiring with two single core FRLS PVC insulated standard copper conductor 6 Sqmm and 1 x 6 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 6 sqmm & one run of earth wire 6 sqmm will be considered as one unit
SEWAGE DISPOSAL WORKS
Supply and installation of non clog vertical sewage submersible pump 2 HP three phase, 440V, 50 Hz capable of delivering 375 LPM 8m head with automatice ON/ OFF switch, TOP tehrmal overload protector including testing complete all as specified and directed.
Supplying, laying in trenches, jointing and testing 80mm bore centrifugally cast ductile iron pipe, S/S class K7 conforming to IS 8329-2000 with necessary DI fittings including testing complete all as specified.
Supply, laying and testing PVC insulated submersible cable and FR PVC sheathed, copper conductor (flexible) industrial cable, 1100 V, conforming to IS : 694 of size 4.0 Sqmm, 3 Core complete all as specified and as shown on drawings
INTERNAL WATER SUPPLY WORKS
Material and labour fo fancy type 15mm bore central hole basin mixture with 'U' shaped round casted spout with 3" long pipe connection with aerator complete all as specified and directed
EXTERNAL ELECTRIC SUPPLY WORKS
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1 m away from the outer edge of PCC chamber. (ii) Water pipe shall be provided in slanting position.
Supply & fixing LED security light fitting 60 watts die-cast aluminium housing,IP 65 protection including 1.5 sqmm 3 core multistrandard Copper conductor cable and UPVC pipe 15 mm bore from Junction box to street light fitting including 2 Nos clamps made out of MS Flat of size 25×6 mm complete with all accessories including 40 mm dia GI Pipe light grade 1.2 m long bracket duly cut and welded at an angle of 120 degree and FI 25×6 mm clamp 2 Nos with bolts, nuts and washers complete all as specified and directed. Cat Part No LHETBXU7PA7B060 of Havells or equivalent Crompton/Philips/Bajaj complete all as specified.
Supply, fixing, installation, commissioning & testing Electrical Panel Board factory made, CPRI approved outdoor cubical type, dust and vermin proof 415 V, 3 phase, 4 wire with common TPN aluminium bus bar 320 Amps 4 Nos, front openable with locking arrangement made of CRCA sheet (protection class IP 54) of thickness not less than 3.15 mm, size 1100x450x1250 mm, mounted on angle iron frame 50x50x6mm, grouted below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates including earthwork,painted as per the 7- tank process, testing and commissioning and consisting with following :- Incoming a) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA- 1 No, make- L&T/C&S/ABB/SIEMENS/SCHNEIDER Outgoing b) MCCBs 415V,16KA, 4 Pole, 100 Amps 50 Hz-02 Nos c) MCB TPN 415 Volts, 32 Amps 50 Hz - 02 No. d) MCB, Single Pole and neutral 240 V, 32 Amps 10 KA - 01 No. e) Aluminium busbar rating- 320 Amps f) LED Indicating lamp- 03 Nos g) Digital Ammeter with CT Ratio 160/5 - 1 No h) Digital Voltmeter - 01 No j) Digital Timer switch with contractor of suitable rating 20A single ph 220V - 01 No
Supply and fixing pole junction box made of thermoplastic with IP 65 degree of protection (EN60529),dust proof, water tight weight acid resistence, corrosion proof insulated and shock proof fire retardant self extingushing, halogen & silica free non-Toxic material,UV resistance (UI subject 94:V2) with internally embedded gasket size of test certificate and verification by glow wire test in accordance with IEC60695-2-11 cat no-K8100 (Make- Hensel) with suitable capacity MCB SP neutral link with three phase copper busbar/connector for connection of cable of suitable size complete all as specified.
Supply and fixing RCC LT cable route indicator of size 75 x 40 x 10cm duly marked with LT cable made of cement concrete (1:2:4) type B-1 as in foundation of electric pole/ structs etc including necessary formwork, fair finished complete all as specified.
DG Sets Supply, installation, commissioning and testing of eco-friendly Static type Diesel Engine driven generating set silent type confirming to CPCB condition/norms, 50 KVA 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank & including all excavation PCC foundation anti vibration pads/ dampers including standard control panel other accessories as per manufacturer's design.The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level.The accostic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt Notification. Specifications of DG set shall be as specified and and comprising of the following:- (A) ENGINE (Prime mover) : Diesel engine vertical type of adequate capacity for 50 KVA ,1500 RPM (conforming to IS: 4722/BS:5514) of suitable BHP as per manufacturer recommendation, Turbo charged water cooled ,12 volts electric battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic techometer.Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shut down in case of fault such as high water temperature low oil pressure,over speed etc including self starter,alternator,coggedV belt,fuel tank with first fill of lub oil and coolant(as applicable) etc complete all as specified. (B) ALTERNATOR: Aternator AC ,3 phase 415 volts 4 wire rated line current for output 50 KVA,PF 0.8 1500 RPM confirming to BS 5000/ IS 4722. Insulation class enclosure/SPDP self excited, self regulated brushless, complete with AVR with +1% voltage regulation directly coupled with above engine. (i) Anti vibration pads for mounting engine and alternator assembly on the base frame/plate or as recommended/provided by the manufacturer (ii) Base frame made out of structural steel as per manufacturer's recommended. design/specifications
Notes : (a) The Engine, alternator,control Panel, Acoustic enclosure shall be integrated unit sourced from OEM only as per Make given in Sch 'A'. (b) All arrangements for Installing, testing & commissioning of DG set is deemed to be included in the quoted rate. The rate quoted deemed to be inclusive of first fill of Engine oil/Lub oil & POL for testing & commissioning complete. (c) Contractor will submit the technical litrature of specific model for approval before placing order.”
Supply and Fixing Steel tubular swaged pole swan neck type complete with cast iron base plate, finial taper plug,bolts,nuts & screws complete as specified type 410 SP-22 (8.5 meters long) complete all as specified and directed.
EXTERNAL WATER SUPPLY WORKS
Material and labour for cutting and jointing the existing pipe line 50mm dia for making branch connection of GI pipe of suitable and making thread for suitable insertion of tee of size 50 x 50 x 50mm bore complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 600 x 600 x 600mm (internal size) with mild steel sheet cover 6mm thick and frame of angle iron of size 40x40x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earth work,150mm thick PCC (1:4:8) type D-2 as in foundation,brick work in cement mortar (1:6), locking arrangement, and all inner size of pit shall be plastered 15mm thick in cement mortar (1:4) and coping in PCC (1:2:4) type B-1 over brick wall complete all as shown in Drg No CEJZ/TD-1060/08 Sh 1/3 to 3/3.
LIGHTENING ARRESTER & PROTECTION WORKS
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1 m away from the outer edge of PCC chamber. (ii) Water pipe shall be provided in slanting position.
Supply and fixing Air termination vertical type, single pointed made of 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead washers etc., complete and including provision of GI tubing light grade 40mm dia, 300mm long with one end embedded in PCC block of size 300mm x 300mm x 300mm and other end fitted with air termination rod, complete all as specified and directed
AIR CONDITIONING WORKS
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type with copper wound, designed for input voltage between 170 volts to 250 volts with output voltage stabilized at 230 volt with accuracy of + 2.5% and of capacity 4 KVA with low and high voltage cut off for 2 to 3 minute time dealy relay complete all as specified and directed.
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type with copper wound, designed for input voltage between 170 volts to 250 volts with output voltage stabilized at 230 volt with accuracy of + 2.5% and of capacity 3 KVA with low and high voltage cut off for 2 to 3 minute time dealy relay complete all as specified and directed.
Supply and fixing in repair sub main wiring with two single core FRLS PVC insulated stranded copper conductor 4 Sqmm and 1 x 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 4 sqmm & one run of earth wire 4 sqmm will be considered as one unit.
HARBHAJAN SINGH KHARBANDA
Vee Vee Enterprises
M/S Yashpaul Gulati
Supreme Constructions
M/s Manoj Construction Co.
Harmesh Kumar Sharma and Sons
Marwaha Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .