Karnataka Power Transmission Corporation Limited
PADMASHREE K T
Tender for providing redundant station auxiliary supply(11kV ref) for complying Protection Audit Recommendations made by SRPC at 220KV SRS Hiriyur
KPTCL/2024-25/SS/WORK_INDENT1472/CALL-2
KPTCL/2024-25/SS/WORK_INDENT1472/CALL-2
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL SEE Transmission Works Circle Davanagere
15 documents required · 14 mandatory · 1 optional
Contractor should have carried out similar type of work/ Augmentation of Power Transformers/providing of additional Transformers / breakers (66 KV & 220 KV) on TK or PTK or labour contract basis in KPTCL/ESCOMS in last Five years. The Contractor shall submit the experience certificate issued by the officer not below the rank of Executive Engineers
Lead Bidder and Consortium Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of techno-commercial bid and shall upload the same along with other bidding documents failing which the offer will be rejected
ESI
Pan card
GST
Letter of undertaking 500rs Bond Paper
Power of Attorney in favour of all the persons signing the documents
The bidder should not have been blacklisted by any Government Department/Power Utilities/Local Bodies of any state. A self declaration in this regard is to be uploaded.
Non performance: The bidder should not have been disqualified for non-performance in any of the Government utilities in the past five years and bidder shall furnish a self-declaration to this effect, failing which the offer is liable to be rejected.
Approved Vendors: Bidders are requested to furnish an undertaking to source the supply of equipment/material from KPTCL approved Vendors only.
Risk and cost declaration.
The bidder shall stand disqualified if annual financial turnover of the bidder is less than Two times the amount put to tender (Rs. 78,68,364/-) in any of the last Five year
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years with KPTCL. A history of awards involving litigations against the bidder or any party or JV may result in rejection of bid Bidders are requested to furnish the self-declaration stating the above and upload the same along with the other documents in the relevant field in the eprocurement portal failing which the offer is liable to be rejected.
No Deviation declaration.
EPF
₹990
₹79,190
18 Dec 2024
18 Dec 2024
4 Jan 2025
26 Dec 2024
Material Portion
Mutli Functional Transducer (MFT) 0.2S class
Opto coupler 110 V DC for 110 kV and 66 kV sub station 220 V DC for 400 kV and 220 kV sub stations
Current Cables copper core with 2 5 sqmm cross section multistrand 7 core for CT termination
Voltage cables copper core with 2 5 sqmm cross section multistrand 4 core for PT termination
Signal communication cables -Armoured copper core with 0.5 sqmm cross section multistrand 10 core
Control cables-copper core with 1.5 sqmm cross section multistrand 10 core
4 core x 6.0 Sq.mm
4 core x 25Sq.mm
19 core x 2.5Sq.mm
11 kV GOS D/B 400 A
Rabbit ACSR Conductor
PG Clamps for Rabbit to Rabbit
11 kV Lightning Arrester, 10 kV, 5 KVA Lightening Arrester Polymeric type with ground disconnetor
LT Distribution Box for 100 250 KVA DTC with MCCBs
HG Fuse unit with solid core insulator
GI Chain link mesh 10 guage 50 50mm opening
LTAC Panel (Indoor), 415V as per technical specification comprising of Volt meter/Ammiterem 2 I/C ACB, 800A+2O/G SFU, 200A+8OG SFU, 100A+14O/G SFU, 63A+12O/G, 32A+1B/C SFU, 800A+1DG Change Over switc...
DG set, 3 Phase , 50Hz, 415V, 0.8 PF, 58.5 KVA including erection 50 kW 58.5 kVA Diesel Generator set rated at 50 kW 58.5 kVA, 415 V, 0.8 pf mounted on a base frame, complete with inbuilt fuel tank an...
11 kV, 3 core, XLPE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 part-2 armouring wires dia and resistivity as per IS-3975. 3x240 sq.mm. Laying
3x240 sq.mm (Indoor Pothead)
3x240 sq.mm (out door Pothead)
Erection Testing and Commissioning
Erection,alignment and fixing to the foundation,indoor 11kv switchgear unit including movement from the point of unloading to the point of erection
Wiring and assisting in testing and commissioning
Testing and commissioning: Identification of wires,ferruling,crimping and termination of wires testing of relays ,CTs PTs and breaker for operation
Annunciator Panel For three feeders
Mutli Functional Transducer (MFT) 0.2S class
Opto coupler, 110 V DC for 110 kV and 66 kV sub-station 220 V DC for 400 kV and 220 kV sub-stations
Current Cables copper core with 2 5 sqmm cross section multistrand 7 core for CT termination
Voltage cables-copper core with 2 5 sqmm cross section multistrand 4 core for PT termination
Signal/communication cables Armoured copper core with 0 5 sqmm cross section multistrand 10 core
Control cables-copper core with 1.5 sqmm cross section multistrand 10 core
Grounding of equipment with 50 X 6 mm GI flat and connecting equipments to earth mat/ grounding pits including all connected works with all materials supplied by the contractor.
Providing C.I. pipe of 100 mm ID 13 mm thick 2.75 mtr long with 2 part GI flat 50 X 6 mm clamp welded all round the pipe etc., including cost of excavation
4 core x 6.0 Sq.mm
4 core x 25Sq.mm
19 core x 2.5Sq.mm
11 kV GOS D/B 400 A
11 kV Lightning Arrester, 10 kV, 5 KVA Lightening Arrester Polymeric type with ground disconnetor
LT Distribution Box for 100/250 KVA DTC with MCCBs
HG Fuse unit with solid core insulator
G.I Chain link mesh 10 guage 50 50mm opening
Guarding Civil work for 2x500 kVA Auxiliary Transformer
LTAC Panel (Indoor), 415V as per technical specification comprising of Volt meter/Ammiterem 2 I/C ACB, 800A+2O/G SFU, 200A+8O/G SFU, 100A+14O/G SFU, 63A+12O/G, 32A+1B/C SFU, 800A+1DG Change Over swit...
Assisting in Testing & commissioning
11 kV, 3 core, XLPE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (part-2) armouring wires dia and resistivity as per IS-3975. 3x240 sq.mm.
3x240 sq.mm (Indoor Pothead)
3x240 sq.mm (out door Pothead
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per dr...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, wit...
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and for...
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mor...
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructu...
Wiring for lighting/power circuit using one of FRLSPVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-6...
Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 lumen maintenance with CRI 80 Power Input 220 240V 50 60Hz and Power factor 0...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,boltsnutsetc.,complete on the existingmetal/P...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
2 gtc-general terms & conditions.doc
Instructions to Tenderers • 0.58 MB
NIT- Sd.doc
Instructions to Tenderers • 0.16 MB
Revised_stamp_duty_payments.pdf
Instructions to Tenderers • 0.82 MB
Volume II.zip
Tender Document • 18.61 MB
Section -DG SET.pdf
Technical Information / Worksheet • 0.44 MB
Techno commercial Hiriyur.xlsx
Techno-Commercial Worksheet • 0.03 MB
Vol 1.zip
Tender Document • 0.30 MB
Annexure A T and C for vendor approval.pdf
Instructions to Tenderers • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .