Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.0 L+₹2.6 L (15.2%)Rejected-Finance 12 MALIKPUR GURDASPUR ROAD SARNA PATHANKOT PUNJAB 145025 | PATHANKOT | PUNJAB | 145025 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹21.9 L+₹4.5 L (26.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹23.1 L+₹5.8 L (33.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹25.8 L+₹8.5 L (48.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S G P MARWAHA L4 | dadwal engineers L5 | Vishav Karma Refrigeration and Electric Work L8 | Vijay Kumar Contractor and Engineers L6 | M/s. Aggarwal Engineers L7 | new hi tech engineers and contractors L2 | Ashoka Engineers L1 | M/S SHRI RAM BUILDERS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Carrying out comprehensive maintenance of day to day Technical area from Technical gate gaurd room to Nesahra gate all installation,pump house and other misc area for internal eletrification complaines by Collection from complaint cell daily 9.00 AM Repair in situ or attending of complaints of Technical area one Elect and one helper after rectifying complaines job card will be return on same date. Defects of the items such as switches, fuse wires, DB, MCB (light/ power), lamp holder (bracket, pandent, batten) bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings, repairing of geysers etc including providing of small pieces of electrical wire of size 1.5 sqmm to 10 sqmm single core/ two core and length not exceding 1.5 mtrs complete all as specified and directed by Engineer-in-Charge.
Note :- Any accessories as mentioned above found unserviceable shall be replaced under respective items of this Sch. seperately. However any minor requirement essential for making overall system serviceable is deemed to be included in the quoted rate of this item. | 270 | Each day Job | 713 ₹1,92,510 | 200 ₹54,000 Lowest | 249 ₹67,230 | 400 ₹1,08,000 | 300 ₹81,000 | 600 ₹1,62,000 | 450 ₹1,21,500 | 450 ₹1,21,500 |
| 2.00 | All as per item No. 1 here in above Canal gate to D loop area all installation,pump house and other misc area complete all as specified and directed by Engineer-in-Charge.
Note:(Item 1 to 2)
i) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down/ Complaint received on Cell phone and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type.
(ii) Penalty for not rectifying the defect in time(within 72 hrs) will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract.
(iii) Manpower requirement for attending and completing day to day complaints will be depending upon the number of complaints which may vary day to day and cost of same is deemed to be included in quoted rate. Contractor is advised to quote accordingly.
(iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M/Rep of MES.
(v) Old material obtained from replaced items under this item shall be contractor's property and will be measured as per Schedule of credit.
(vi) Cost of minor spares i.e, insulation tape, lugs, thimbles etc are deemed to be included in the quoted rate. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor.Items replaced shall be measured and paid seperately .
(vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates.
(viii) Making good the area / cleaning the area will be mandatory for the contractor & failing which penalty of Rs. 5000/- will be charged at each up stance
Note:-(Items 3 to 38 supply only and fixing against Item 1 to 2) and (Items 88 to 96 supply only and fixing against Item 95) | 270 | Each day Job | 713 ₹1,92,510 | 200 ₹54,000 Lowest | 249 ₹67,230 | 400 ₹1,08,000 | 500 ₹1,35,000 | 380 ₹1,02,600 | 450 ₹1,21,500 | 450 ₹1,21,500 |
| 3.00 | PVC Wire single core multi strnderd FRLS of size 1.5 sq mm complete all as specified and directed by Engineer-in-Charge. | 450 | RM | 5 ₹2,250 | 16 ₹7,200 | 29 ₹13,050 | 10 ₹4,500 | 19 ₹8,550 | 27 ₹12,150 | 2 ₹900 Lowest | 5 ₹2,250 |
| 4.00 | PVC Wire single core multi strnderd FRLS of size 2.5 sq mm complete all as specified and directed by Engineer-in-Charge. | 350 | RM | 7 ₹2,450 | 25 ₹8,750 | 39 ₹13,650 | 17 ₹5,950 | 31 ₹10,850 | 35 ₹12,250 | 3 ₹1,050 Lowest | 10 ₹3,500 |
| 5.00 | PVC Wire single core multi strnderd FRLS of size 4.0 sq mm complete all as specified and directed by Engineer-in-Charge. | 250 | RM | 10 ₹2,500 | 39 ₹9,750 | 49 ₹12,250 | 22 ₹5,500 | 50 ₹12,500 | 55 ₹13,750 | 5 ₹1,250 Lowest | 15 ₹3,750 |
| 6.00 | PVC Wire single core multi strnderd FRLS of size 6 sq mm complete all as specified and directed by Engineer-in-Charge. | 180 | RM | 9 ₹1,620 | 45 ₹8,100 | 89 ₹16,020 | 30 ₹5,400 | 72 ₹12,960 | 55 ₹9,900 | 5 ₹900 Lowest | 20 ₹3,600 |
| 7.00 | Switch piano flush button single pole one way 5 amps 230 volts complete all as specified and directed by Engineer-in-Charge. | 600 | Each | 35 ₹21,000 | 15 ₹9,000 | 23 ₹13,800 | 20 ₹12,000 | 18 ₹10,800 | 20 ₹12,000 | 8 ₹4,800 Lowest | 12 ₹7,200 |
| 8.00 | Switch piano flush button single pole one way 15 amps 230 Volts complete all as specified and directed by Engineer-in-Charge. | 350 | Each | 80 ₹28,000 | 55 ₹19,250 | 79 ₹27,650 | 60 ₹21,000 | 60 ₹21,000 | 65 ₹22,750 | 20 ₹7,000 Lowest | 50 ₹17,500 |
| 9.00 | Switch piano flush button single pole two way 5 amps 230 volts complete all as specified and directed by Engineer-in-Charge. | 40 | Each | 10 ₹400 | 25 ₹1,000 | 23 ₹920 | 30 ₹1,200 | 70 ₹2,800 | 25 ₹1,000 | 6 ₹240 Lowest | 18 ₹720 |
| 10.00 | Socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed by Engineer-in-Charge. | 450 | Each | 40 ₹18,000 | 28 ₹12,600 | 35 ₹15,750 | 30 ₹13,500 | 38 ₹17,100 | 55 ₹24,750 | 10 ₹4,500 Lowest | 18 ₹8,100 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
5 Jun 2025, 6:00 pmClosed
Sh Mahajan Singh
GE (AF) Pathankot
COMPREHENSIVE MAINTENANCE OF INTERNAL ELECTRIFICATION AND CONNECTED ITEMS IN TECHNICAL AREA AT AIR FORCE STATION PATHANKOT
2025_MES_708099_1
GE/PAF-18/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹76,000
Yes
22 Aug 2025
15 May 2025
9 Jun 2025
15 May 2025
5 Jun 2025
29 May 2025
Amount
Carrying out comprehensive maintenance of day to day Technical area from Technical gate gaurd room to Nesahra gate all installation,pump house and other misc area for internal eletrification complaines by Collection from complaint cell daily 9.00 AM Repair in situ or attending of complaints of Technical area one Elect and one helper after rectifying complaines job card will be return on same date. Defects of the items such as switches, fuse wires, DB, MCB (light/ power), lamp holder (bracket, pandent, batten) bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings, repairing of geysers etc including providing of small pieces of electrical wire of size 1.5 sqmm to 10 sqmm single core/ two core and length not exceding 1.5 mtrs complete all as specified and directed by Engineer-in-Charge. Note :- Any accessories as mentioned above found unserviceable shall be replaced under respective items of this Sch. seperately. However any minor requirement essential for making overall system serviceable is deemed to be included in the quoted rate of this item.
All as per item No. 1 here in above Canal gate to D loop area all installation,pump house and other misc area complete all as specified and directed by Engineer-in-Charge. Note:(Item 1 to 2) i) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down/ Complaint received on Cell phone and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. (ii) Penalty for not rectifying the defect in time(within 72 hrs) will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (iii) Manpower requirement for attending and completing day to day complaints will be depending upon the number of complaints which may vary day to day and cost of same is deemed to be included in quoted rate. Contractor is advised to quote accordingly. (iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M/Rep of MES. (v) Old material obtained from replaced items under this item shall be contractor's property and will be measured as per Schedule of credit. (vi) Cost of minor spares i.e, insulation tape, lugs, thimbles etc are deemed to be included in the quoted rate. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor.Items replaced shall be measured and paid seperately . (vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates. (viii) Making good the area / cleaning the area will be mandatory for the contractor & failing which penalty of Rs. 5000/- will be charged at each up stance Note:-(Items 3 to 38 supply only and fixing against Item 1 to 2) and (Items 88 to 96 supply only and fixing against Item 95)
PVC Wire single core multi strnderd FRLS of size 1.5 sq mm complete all as specified and directed by Engineer-in-Charge.
PVC Wire single core multi strnderd FRLS of size 2.5 sq mm complete all as specified and directed by Engineer-in-Charge.
PVC Wire single core multi strnderd FRLS of size 4.0 sq mm complete all as specified and directed by Engineer-in-Charge.
PVC Wire single core multi strnderd FRLS of size 6 sq mm complete all as specified and directed by Engineer-in-Charge.
Switch piano flush button single pole one way 5 amps 230 volts complete all as specified and directed by Engineer-in-Charge.
Switch piano flush button single pole one way 15 amps 230 Volts complete all as specified and directed by Engineer-in-Charge.
Switch piano flush button single pole two way 5 amps 230 volts complete all as specified and directed by Engineer-in-Charge.
Socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed by Engineer-in-Charge.
Switch & Socket with box type 5 amps 5 pin flush type, 230 volts complete all as specified and directed by Engineer-in-Charge.
Socket 15 amps 3/5 pin flush type, 230 volts complete all as specified and directed by Engineer-in-Charge.
Switch & Socket box type 15 amps 3/5 pin flush type, 230 volts complete all as specified and directed by Engineer-in-Charge.
Lamp holder insulated body with back plate for batten fittings complete all as specified and directed by Engineer-in-Charge.
Ceiling rose surface bakelite 3 terminals complete all as specified and directed by Engineer-in-Charge.
Bell ding dong type 230 volts single pole complete all as specified and directed by Engineer-in-Charge.
Piono type bell push 5 Amp complete all as specified and directed by Engineer-in-Charge.
Compact fluorescent lamp 36 watts 230 volts 6500 K, 2 pin complete all as specified and directed by Engineer-in-Charge.
Fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% complete all as specified and directed by Engineer-in-Charge.
Plug top 3 pin 5 amps AC 230 Volts complete all as specified and directed by Engineer-in-Charge.
Plug top 3 pin 16 amps AC 230 Volts complete all as specified and directed by Engineer-in-Charge.
Cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 1.50 sqmm, cut to size all as required at site complete all as specified and directed by Engineer-in-Charge.
tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed by Engineer-in-Charge.
Gun metal ball bearing No 6200 to 6203 of any description and size to fan. complete all as specified and directed by Engineer-in-Charge.
Gun metal bushes of any description and size to suit existing motor shaft of fan. complete all as specified and directed by Engineer-in-Charge.
LED tube rod 18/20 watt (4ft), 240 volts complete all as specified and directed by Engineer-in-Charge.
lamp LED 9/12 watt, 240 volts. complete all as specified and directed by Engineer-in-Charge.
Flexible wire 23/0.00076, twin core twisted, PVC insulated copper stranded conductor. complete all as specified and directed by Engineer-in-Charge.
Modular type switch 6 Amp one module complete all as specified and directed by Engineer-in-Charge.
Modular type switch 16 Amp one module complete all as specified and directed by Engineer-in-Charge.
Modular type Socket 6 Amp two module complete all as specified and directed by Engineer-in-Charge.
Modular type Socket 16 Amp two module complete all as specified and directed by Engineer-in-Charge.
Modular type fan regulator 6 Amp two module step type complete all as specified and directed by Engineer-in-Charge.
Modular type bell push 6 Amp one module complete all as specified and directed by Engineer-in-Charge.
Plastic laminated top sheet cover 3 mm thick of size 5"x5" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers with sunken pressed steel terninal box 1.6 mm thick of suitable size complete all as specified and directed by Engineer-in-Charge.
Plastic laminated top sheet cover 3 mm thick of size 8"x5" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers with sunken pressed steel terninal box 1.6 mm thick of suitable size complete all as specified and directed by Engineer-in-Charge.
Plastic laminated top sheet cover 3 mm thick of size 11"x9" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers with sunken pressed steel terninal box 1.6 mm thick of suitable size complete all as specified and directed by Engineer-in-Charge.
Plastic laminated top sheet cover 3 mm thick of size 13"x11" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside regulators/ light fitting/ MCBs serviceable/ unserviceable items for reuse with in the same bldg or deposited to MES store yard complete all as specified and directed by Engineer-in-Charge.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit Medium grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed by Engineer-in-Charge. (a) One light point/fan point controlled by one switch
(b) One 5 Amps socket point on same board with other switches
(c) One 5 Amps switch socket outlet point on an independent board.
(d) One bell point controlled by one 5 Amps bell push
(e) One light point controlled by two Nos two way switch.
All as per item No 40 above but for point wiring for power point with 2.5 Sqmm (nominal area) PVC insulated copper cable 1100 Volt grade drawn through and including heavy duty PVC conduit ISI marked as required at site along with accessories with 1.5 Sq mm PVC insulated stranded copper conductor cable connected to common earth dolly with all accessories for 15 Amps socket point complete all as specified and directed by Engineer-in-Charge.
All as per srl item No-40 here in above but in existing conduit existing & CI/MS sunk boxes complete all as specified and directed by Engineer-in-Charge. (a) One light point/fan point controlled by one switch
(b) One 5 Amps socket point on same board with other switches
(c) One 5 Amps switch socket outlet point on an independent board.
(d) One bell point controlled by one 5 Amps bell push
All as per above item 40 but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 1.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge.
Material and labour Switch piano flush type single pole, one way 5 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge.
Supply and fixing switch piano flush type,15 Amps, Single pole, two way complete all as specified and directed by Engineer-in-Charge.
Material and labour for socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Material and labour for socket outlet 2 in 1, 3 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Material and labour Switch piano flush type single pole, one way 15 Amps 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement electronic fan regulator 230V, stepped, socketed type complete all as specified and directed by Engineer-in-Charge.
Material and labour for ceiling rose surface bakelite 63.5 x 20 mm, three terminals complete all as specified and directed by Engineer-in-Charge.
Material and labour for bell push 5 Amps 230 V, AC circuit complete all as specified and directed by Engineer-in-Charge.
Material and labour for call bell ding dong 230 V AC circuit complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Lamp holder, PVC/Polycarbonate type with back plate for batten fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LED box type fitting pre-wired for LED tube with enegry efficient LED tube extruded aluminium heat sink & high efficiency diffuser 4 Ft version for 20/22 Watts, including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as specified and directed by Engineer-in-Charge.
Supply and fix Recess mounted LED fitting with high transmittance polycarbonate diffuser 36 watt fit to 600x600 mm modular/pop/gypsum ceilling complete with including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as specified and directed by Engineer-in-Charge.
Supply and fixing energy saving new generation 10 W LED bulk head luminaire with opal diffuser watt suitable for 10 W LED 6000K complete with LED lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fix batten for LED tube light pre coated CRCA sheet steel,end caps made up with engineering plastic with 18 W highly efficient t8 tube with polycarbonated body complete accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fix batten for LED tube light pre coated CRCA sheet steel,end caps made up with engineering plastic with 20 W highly efficient t8 tube with polycarbonated body complete accessories complete all as specified and directed by Engineer-in-Charge.
Supply & fixing and Testing MCCB DB (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DB's IK-09 flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable management including MCCB 100 Amps,ICs=100%ICu, 25KA four pole as in comer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3complete all as specified and directed by Engineer-in-Charge including taking out old unserviceable DB and removing from site.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 230 Volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 230 Volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 230 Volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge.
Supply and replacement MCB single pole 230 Volts any rating from 5 to 30 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
Supply and replacement MCB SPN 230 Volts any rating from 5 to 30 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
Supply and replacement MCB three/four pole 415 volts any rating up to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
Material and labour for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 230 Volts, complete with one single pole MCB of 20 amps earthing complete all as specified and directed by Engineer-in-Charge.
Material and labour for submain wiring with two single core FRLS insulated flexible copper conductor cable of sze 4 sqmm and one single core PVC FRLS insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge.
All as per srl item No-74 here in above but in existing conduit & CI/MS sunk boxes complete all as specified and directed by Engineer-in-Charge.
Material and labour for submain wiring with two single core FRLS insulated flexible copper conductor cable of sze 6 sqmm and one single core PVC FRLS insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge.
All as per srl item No-76 here in above but in existing conduit & CI/MS sunk boxes complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC medium grade 20 mm conduit incl complete fitting and fixture i.e. bend , elbow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC medium grade 25 mm conduit incl complete fitting and fixture i.e. bend , elbow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and fix Capacitor AC 415 volts 3.15 mfd 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix Capacitor AC 415 volts 2.5 mfd 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim conductor multistranded of size 10 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable flat or circular complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim conductor multistranded of size 16 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable flat or circular complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement for point wiring with 1.5 sqmm 1100 volts grade Unilay-FRLS insulated copper conductor single core multi strand flexible cable in and including ERW rigid steel conduit fittings and accessories including flame proof bends,couplers, junction boxes etc fixed on wall/ceiling with proper fixing arrangements incl copper conductor 1.5 sqmm PVC insulated unsheathed multistranded copper conductor single core cable (green color) as earth lead continuity conductor fixed to earth terminal and matellic body of light fittings complete all as suitable fir class II Zone IE IIA for one light point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 84-above here in above but in existing conduit existing & CI/MS sunk boxes complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No-84 here in above but for 3 pin 15 Amps socket with 2.5 sqmm complete all as specified and directed by Engineer-in-Charge.
All as per srl item No- 84 abve here in above but in existing conduit existing & CI/MS sunk boxes complete all as specified and directed by Engineer-in-Charge.
Suuply and fixing explosion proof rotary switch, single pole ON/OFF with cable termination box of 16 Amps rating 250 Volts class E Ex I C suitable for class 1, Zone 2 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement for flame proof switch socket and plug combind in LM6 cable termination box in LM6 , 16A, 250V,2P+Earth complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement for flame proof switch socket and plug combind in LM6 cable termination box in LM6 , 25A, 250V,2P+Earth complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement for surface mounting industrial plug and socket IP-66/67 protection , 415 volts , 63 Amp complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement for metal industrial plug and socket with provision with 20 Amp SP MCB complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of flame proof LED light fitting 1x20 Watt including all accessories prewired with heat resistant glass cover, polyester resin enclosure and centrally locking system suitable for class I,Zone II E Ex II C including proper fixing arrangement on elevation on angle iron frame with clamps, nut, bolts & washers of suitable size as recommended by manufacturer and directed by Engr-in-Charge inluding electric connection complete all as specified and directed by Engineer-in-Charge.
Taking down carefully geyser 25 to 50 Ltrs capacity from wall after unscrewing nuts/bolts etc and again refixing in position after repair & replacement of spare-parts incl testing complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of unserviceable 50Ltr capacity internal tank of geyser with copper tank heavy duty guage with double lapped joint 50 ltr capacity suitable for geyser of any type/make with necessary screws, nut bolts gasket etc complete and all as specified including taking down of Geysers and reassembling, testing and reinstallation after repair complete all as specified and directed by Engineer-in-Charge.
All as per item No 95 above but 25 Ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Supply only in Replacemet of old usnerviceable syphon assembly for geyser having hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as specified and directed by Engineer-in-Charge.
Supply only in Replacement of old unserviceable heating element with heating element AC 230 volt of rating 1500 watt complete all as specified and directed by Engineer-in-Charge.
All as per Srl 98 above but of rating 2000 Watt capacity complete all as specified and directed by Engineer-in-Charge.
Supply only in Replacement of old unserviceable Thermostat switch with Thermostat switch for geyser AC 230 volt adjustable range from 60 degree celslus complete all as specified and directed by Engineer-in-Charge.
Supply only in Replacement of old unserviceable PVC connection with steel hose pipe 15mm bore (450mm long) complete with brass nuts at water temprature upto100 degree celceus complete all as specified and directed by Engineer-in-Charge.
Supply only in Replacement of fusible/safety plug melting at 95-100 degree centigrade suitable for any type/make of Geyser complete all as specified and directed by Engineer-in-Charge.
Supply only in Replacement of old unserviceable cable with PVC sheathed, copper conductor, 3 core 2.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp suitable bracket with all fixing accessories, impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp suitable bracket with all fixing accessories, impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of unserviceable and broken with new exhaust fan made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM,, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of unserviceable and broken with new exhaust fan made of sturdy Engineering plastic complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC,1200 RPM,, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of unserviceable and broken with new exhaust fan steel body , 450 mm sweep, with blades and frame and louvers.,single phase, 230 Volts AC, with provisioning of suitable fixing/tightening arrangements and connecting/testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of unserviceable and broken with new wall mounted fan 400 mm sweep, single phase, 230 Volts with regulator, oscilation type complete fixed properly on wall and connecting/testing on load complete all as specified and directed by Engineer-in-Charge.
Supply & fixing SLEEK surface mounted round downlight 12 W for soft diffused lighting ,powder coated CRCA sheet steel housing with high efficiency translucent acrylic in center complete fitting including taking down all fixing arrangement complete with all as specified and directed by Engr-in-Charge.
Supply & fixing SLEEK surface mounted square downlight 15 W for soft diffused lighting ,powder coated CRCA sheet steel housing with high efficiency translucent acrylic in center complete fitting with all fixing arrangement complete including taking down with complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LED avaiation light luminaires ,integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including connecting electricaly to existing location using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 9W LED bollards light in cylindrical shape with opal acrylic diffuser and IP 65 protection including connecting electricaly to existing location using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED amp including connecting up with three core flexible copper conductor cable of suitable size complete size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing decorative wall mounting fitting made out of polycarbonated suitable for and incl up to 10 watts LED bulb complete all as specified and directed by Engineer-in-Charge.
Supply and fixing fancy LED lamp fitting decorative, wall mounting, chrome finish fixture with opal glass diffuser suitable & including 7 to 9 W LED lamp complete all as specified & directed by Engr In Charge.
Supply and fixing LED Poarch light fitting LED commercial 2x2 recessed having white powder coated CRCA body with soft opal PMA diffuser at centre, seprate driver suitable for Armstrong and Grid ceiling 36 W complete all as specified and directed by Engr In Charge.
Supply and fixing LED decorative post top lantern Gate light 40 to 45 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version including taking down old unserviceable post of lantern fittings complete all as specified and directed by Engineer-in-Charge.
Cleaning thoroughly gyser 25/50 Ltr capacity with Kerosene Oil and painting with two coat of synthetic enamelled paint including preparation of surfaces, change the unserviceable lamp any type and writing MES No after painting complete all as specified & directed by Engineer-in-Charge
Replacement of old unserviceable bolt with bolt 12mm 100mm long completecomplete all as specified and directed by Engineer-in-Charge. Note- bolt shall be grouted with hammer drill only.
Supply and laid Galvanised steel water tubing in trenches/floor/wall of 15 mm dia alongwith complete fittings etc as required at site complete all as specified and directed by Engineer-in-Charge.
Supply & fixing stop cock CP 15 mm bore with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
Gun metal globe or gate valves,with iron wheel head,screwed both ends from iron pipes and fixed in repair of following sizes complete all as specified and directed by Engineer-in-Charge:- (a) 25 mm bore.
(b) 20 mm bore.
(c) 15 mm bore.
Supply and fix bib taps , cast copper alloy with crutch or butterfly , handle , screwed for iron pipes of 15 mm bore complete all as specified and directed by Engineer-in-Charge.
Material and labour for Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through existing PVC/Steel conduit/casing capping and including 1 run of 1.5 Sqmm PVC insulated unsheathed copper conducter with multistranded copper conductor as earth continuity complete all as specified and directed by Engineer-in-Charge:- Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
new hi tech engineers and contractors (BID ID -3313923)
M/S SHRI RAM BUILDERS (BID ID -3314310)
M/S G P MARWAHA (BID ID -3308016)
dadwal engineers (BID ID -3311070)
Vijay Kumar Contractor and Engineers (BID ID -3313249)
M/s. Aggarwal Engineers (BID ID -3312920)
Vishav Karma Refrigeration and Electric Work (BID ID -3313156)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .