| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC NATIONAL TOWER 5TH FLOOR SCO 89 DSC RANJIT AVENUE AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹4.5 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹4.6 Cr+₹13.5 L (3.02%)Rejected-Finance | ₹4.6 Cr+₹13.5 L (3.02%) | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹5.2 Cr+₹72.8 L (16.3%)Rejected-Finance | ₹5.2 Cr+₹72.8 L (16.3%) | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹5.7 Cr+₹1.2 Cr (27.6%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹5.7 Cr+₹1.2 Cr (27.6%) | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹6.6 Cr+₹2.2 Cr (48.6%)Rejected-Finance | ₹6.6 Cr+₹2.2 Cr (48.6%) | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹5.8 Cr
EMD Value
₹6.2 L
Closing Date
24 Jun 2023, 6:00 pmClosed
HQ Chief Engineer Delhi Zone Delhi Cantt-10
HQ Chief Engineer Delhi Zone Delhi Cantt-10
COMPREHENSIVE REPAIR AND RESTORATION OF OPERATION THEATRE INTENSIVE CARE UNIT OF BASE HOSP DELHI CANTT 10
2023_MES_602319_1
CEDZ/TOKEN-14 OF 2023
Open Tender
Civil Works
Item Rate
120 days
Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹3,000
GE (East)
₹6.2 L
Yes
11 Jul 2023
10 Jun 2023
26 Jun 2023
10 Jun 2023
24 Jun 2023
17 Jun 2023
10 Jun 2023 - 15 Jun 2023
Amount
Taking down chowkhat or frame without taking off shutters of any description exc 1.5 sqm and n-exc 4 sqm each complete all as specified and directed.
S&F Powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron)
S&F aluminium powder coated window and ventilator shutter ,side hung type without sas bar, aluminium section weighting 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws , anodised aluminium fitting such as peg stays 150mm long (1 No), hinges tyjpe B-21 100mm long (2 Nos) suitable handle (1 No|) complete all as specified.
S&F aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified
S&F aluminium powder coated Sliding door shutters with frame, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing,handles 2 Nos in each door, 5mm th glass, 12mm thick PVC moulded solid board both side prelaminated ,anodised aluminum snap beading, Chanel and roller, screws etc. complete all as specified
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S & F repair extruded aluminum alloy section body door closer hydraulically regulated, design No 3 universal type suitable for door shutter 851 mm to 1000 mm in width and of weight 61 to 80 Kg each cast iron body all as specified Make : Hardwyn/Godrej
S&F repair brass mortice lock vertical type 100mm size 4 levers for aluminium door with duplicate keys complete as directed by Engineer-in-Charge.
S&F repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete for glass/aluminium door as directed by Engineer in charge.
S & F 12mm mm thick PVC moulded solid board both side prelaminated for door and partition complete all as specified and as directed.
S & F 5.5mm thick Frosted glass and glazing with oil putty in square exc 0.5 Sqm in each pane or rubber beading as required complete all as specified & directed.
Demolition of brick work built in cement mortar complete all as specified and directed
M & L for brick work with sub-class B brick straight or curved on plan built in cement mortar 1 : 6 complete all as specified and directed
Taking down cement plaster of any description on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or on concrete surfaces finished fair and even without using extra cement.
M&L for 10mm thick cement plaster in cement mortar 1:3 on fair face of brick or concrete surface/ceiling finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surface of walls and applying one coat of wall care putty then scrubbing by sand paper to prepare a even surface and applying priming paint followed by applying two coats of Acrylick interior Emulsion paint complete all as specified and directed.
M&L for for two coat of oil bound distemper including prepration of new ceiling surface complete all as specified and directed
M & L for complete removal of existing treatment from old decorated wall surface by scrapping by electrically operated grinder machine/electric regmal machine and applying one coat of wall care putty then scrubbing by sand paper to prepare a even surface and applying priming paint followed by applying two coats of Acrylick interior Emulsion paint complete all as directed. (Asian Paints,Berger)
M & L for complete removal of existing treatment from old decorated wall surface by scrapping by electrically operated grinder machine/electric regmal machine and applying one coat of wall care putty then scrubbing by sand paper to prepare a even surface and applying priming paint followed by applying two coats of Oil Bond Distemper complete all as directed. (Asian Paints,Berger)
M&L for preparation of Old ceiling surfaces & applying one coat of oil bound distemper complete all as specified and as directed
M&L remove existing paint from decorated Wooden surface by scrapping by electrically operated grinder machine/electric regmal machine and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as directed. (Asian Paints,Berger)
Dismantling wall ceiling boards (Fibre pulp. Insulation, AC boards,wooden boards,Gypsum ceiling etc) or insulation boards/slabs/composite panel, etc any thickness including cover fillets and ceiling frame work including disposal of all debris exc 1.5 Km not exc 5 Km and complete complete all as specifed & as directed.
M&L for Wall PANELS: Pre-fabricated Modular ceiling Panels, 50mm thick, with sloping panels PUF panels, between one sheets of 0.8mm & One Sheet 0.5 mm PPGI (Pre Painted Galvanized Steel) having PUF density of 40kg/m3 with proper supports. Wall panels shall be fixed to the floor with Channels & anchor fastener and interlocked with each other thru CAM LOCK system. Ceiling Panels shall be supported with wall panels thru L type Flashing, CAM LOCK system and ceiling support system as required. Panels including cutouts for lights, pendants, electrical switch sockets etc. Antibacterial & Antifungal paint coating supply and installation of jointless coating: for wall ceiling and corner panels: filling of all joints and cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial and anti fungal paint equivalent to a min dry film thickness of 300microns complete all as specified and as directed . (Paint-SKK Japan) (PPGI Sheet Make‐ Tata steel / Bhushan / National. (Make- MHS , CHP,Isolloyd,Maharaja Polyurethane)
M& L for GI anodised snap grid ceiling made of Tee and angle of size 24.5 x 24.5 x1.50 mm thick, size of grid 605 x 605 mm with GI wire suspender 2 to 3 mm dia fixed with wooden/steel truss/rafter flat or slope complete all as specified and as directed.
M&L for 4 mm thick E-board (designer)classic of size 595 x 595 mm, fixed to GI snap grid ceiling flat or slope complete all as specified and as directed. (Make : Everest or equivalent).
M&L for CEILING PANELS: Pre-fabricated Modular ceiling Panels, 50mm thick, with sloping panels PUF panels, between one sheets of 0.8mm & One Sheet 0.5 mm PPGI (Pre Painted Galvanized Steel) having PUF density of 40kg/m3 with proper supports. Wall panels shall be fixed to the floor with Channels & anchor fastener and interlocked with each other thru CAM LOCK system. Ceiling Panels shall be supported with wall panels thru L type Flashing, CAM LOCK system and ceiling support system as required. Panels including cutouts for lights, pendants, electrical switch sockets etc. Antibacterial & Antifungal paint coating supply and installation of jointless coating: for wall ceiling and corner panels: filling of all joints and cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial and anti fungal paint equivalent to a min dry film thickness of 300microns complete all as specified and as directed (Paint-SKK Japan) (PPGI Sheet Make‐ Tata steel / Bhushan / National. (Make- MHS , CHP,Isolloyd,Maharaja Polyurethane)
M&L12mm thick Gypsum board as in ceiling/lining fixed with counter sunk screws on & including GI channels frame work of standard section as per manufacturers instruction , fixed @ 1.2m in one direction and 45cm in C/C in other direction with necessary fixing arrangement at their junction point at desired heights below roof slab and including two coats of antibacterial & antifungal paint over a coat of primer on exposed surfaces, the frame work shall be fixed with the help of GI suspenders of suitable size with the help dash fasteners and along wall, making good disturbed surfaces smoothening the gypsum board, POP lining at joints panning as required complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and as directed.
S&F of Imported Vinyl Floor seamless antistatic conductive ESD, anti fungal vinyl flooring system, 2 mm thick , with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting. . Flooring in operation theater room will be seamless with perfectly curved flash covings, resistance to mechanical stress and dynamic loads and having ESD/EMI (Conductive) protection characteristics, 2mm thick, washable vinyl. The condictive carbon coated PVC pellets create the permanent static conductive properties. It complies with EN 649. Before laying the Flooring inside the Operation theater a copper strip of width of 25 mm and thickness of 0.05mm is placed in such a way the each flooring tiles get cunnected to earthing complete all as specified and as directed. ( Make - MHS, Gerflor, Tarkett or Equivalent)
M&L for Joint free Glazed ceramic tiles of size 450mmX 350mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 15 mm thick rendering in CM 1 :4 complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in cm 1 : 6 complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in cm 1 : 6 complete all as specified and as directed.
M & L for joint free Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in dado up to ceiling height etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in CM 1 :4 complete all as specified and as directed.
Dismantling of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floor, aprons etc and including disposal of all debris exc 1.5 KMtr not exc 5 Km complete all as specified and as directed.
M&L for 20 mm thick Granite work in platforms, partitions and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite & moulding the edges of granite including 20 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L 20-25 mm thick machine cut kota stone flooring laid over and including screed bed or bedding layer mortar 20mm thick in cement mortar 1:6 for laying floor finished jointed and pointed with grey cement slurry mixed with pigments to match the shads incl rubbing and polishing upto mirror image complete all as specified and as directed.
S&F in repair 2 Way Automatic Surgical Scrub sink of size 1500 mm length x 1365mm height x 565 mm depth, made out of 1.6 mm thick SS 304 stainless steel seamless welding, polished to stain finish complete with themostatic mixing valve for Hot & Cold water, Straingers, Jaquar Spouts, Soap Stand, Touchless Senser & Foot operated Spout bypass system etc complete all as specified and directed. Make : Modular Health Care System/CMP Metal/Creative Health Tech Pvt Ltd.
S&F in repair 3 Way Automatic Surgical Scrub sink of size 2100mm length x 1365mm height x 565 mm depth, made out of 1.6 mm thick SS 304 stainless steel seamless welding, polished to stain finish complete with themostatic mixing valve for Hot & Cold water, Straingers, Jaquar Spouts, Soap Stand, Touchless Senser & Foot operated Spout bypass system etc complete all as specified and directed. Make : Modular Health Care System/CMP Metal/Creative Health Tech Pvt Ltd.
S & F in repair Automatic operated Hemettically sealed sliding door with High Pressure Laminate on both side, Door size ( 1500mm wide 2100mm height) complete with double toughned glass vision window of 300mm x 300mm and smooth effortless sliding door runs on nylon wheel within an aluminum extrusion high qulity rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door. The doorframes consist of reinforced plasterboard panels faced with the same laminate as the door and will be edged with an aluminium extrusion and with concealed fixings that are adjustable during installation to ensure a 100% hermetic seal is achieved. Microcontroller based door automation unit complete with motor, touchless hand sensor 2 Nos , foot switch 2 nos, safety beam sensor complete all as specified and directed. . Make : Western India Electromedical Systems Pvt. Ltd/Tanvi enterprics/Hospedia Medicare Pvt. Ltd/MHS
S & F in repair Automation Kit set for Automatic operated Hemettically sealed sliding door with Microcontroller based door automation unit complete with motor, touchless hand sensor 2 Nos, foot swith 2 Nos safety beam sensor etc complete all as specified and direceted. . Make : Western India Electromedical Systems Pvt. Ltd/Tanvi enterprics/Hospedia Medicare Pvt. Ltd/MHS
S&F in repair white water closet floor mounted two piece Closet 'S' Trap Square of size 475 x 340 x 750 mm with soft close seat cover with twin flush fitting with Cistern complete all as specified and as directed.
S&F in repair One piece white Wash Basin with Pedestal of approved make for size 560 x 415 x 820 mm complete all as specified and directed.
S & F in repair vitreous china urinals half stall type white including connection to inlet and out going pipe (waste coupling) complete fixed to walls with steel screws and PVC rawel plug and making good the surface by white cement to match the wall shade complete all as specified and directed.
S&F in repair 32 mm bore waste coupling brass chromium plated for VC sink, VC WHB, VC urinals, steel sinks etc with long screwed shanks and fly nuts, complete all as specified and as directed. Make: Jaquar Cat No: ALD 705 or equivalent model of Parko / Zim.
S&F in repair 32 mm bore waste pipe for WHB, Sink, Urinals etc complete all as specified and as directed.
S&F in repair 15 mm bore chromium plated fancy type brass two way angle valve with elegant knob screwed down high pressure screwed both ends for Iron pipe or for union complete including CP cap complete all as specified and directed.
S&F in repair 15 mm bore chromium plated fancy type brass angle valve with elegant knob screwed down high pressure screwed both ends for Iron pipe or for union complete including CP cap complete all as specified and directed.
S&F in repair 15 mm bore CP bib cock long nose brass chromium plated with elegant knob screwed down high pressure complete including CP cap all as specified and as directed.
S&F in repair 15mm bore sensotronic sensor faucet chromium plated swan neck for WHBs complete all as specified and as directed. Make – Jaquar Cat No. SNR-CHR-51011/Marc
S&F in repair 600mm Long PVC connection suitable for 15mm bore pipes complete all as specified and as directed.
S&F in repair 125mm dia chromium plated gratings over nahani / floor traps including embedded the same in white cement to match complete all as specified and directed.
S&F in repair chromium plated toilet paper holder brass fixed to wall with brass screw complete all as directed. Make: Jaquar Cat No: ACN-1153N or equivalent model of Marc/Prayag.
S&F in repair chromium plated brass soap dish fixed to wall with brass screw complete all as directed. Make: Jaquar Cat No: ACN-1131N or equivalent model of Marc/Prayag.
S&F in repair tubular towel rail 20 mm dia 60 cm long of brass chromium plated fixed to wall with brass screw complete all as specified and as directed. Make: Jaquar Cat No: ACN-1111NM or equivalent model of Marc/Prayag.
S&F in repair CP Jet with 1200 mm CP PVC connection pipe for EWC complete all as specified and as directed.
S&F in repair health faucet with 1m long flexible tube in CP finish & wall hook for EWC complete all as specified and as directed. Make: Jaquar Cat No: ALD-573 or equivalent model of Marc/Prayag.
S&F in repair bevelled edge looking mirror 6mm thick of approved shape & size of superior quality glass mounted on wall with screws, washers complete all as specified & directed.
S&F in repair Urinal Spreader of CP White colour fixing to 15 mm bore pipe complete all as specified and as directed.
Dismantling of CI pipes & fitting of any description & position up to 100 mm dia complete all as specified & directed.
S&F 75mm PVC (SWR) pipe single socketed, in any length with rubber ring jointes , laid in trenches or in floor complete all as specified and directed.
S&F PVC (SWR) floor trap 75 mm dia, plain with grating including jointing with solvent cement complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning or refixing or removal to store complete all as specified and as directed.
S & F 15 mm bore galvanized steel tubing medium grade with all fitting and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S & F 20 mm bore galvanized steel tubing medium grade with all fitting and fixed to walls and ceiling or laid in floors complete all as specified and directed.
M&L for cleaning ,rubbing and polishing old stone slab flooring/wall any type of stone by electrically operated machine complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F steel tubular trusses purlins, rafter vertical post and similar works including special shaped washer etc. complete using ERW or induction butt welded tubes including cleats, plates,MS flats complete conforming to IS 1161-1998 Gde st-240
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Fe-410-W(GdeE-250) quality 'A' complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F rolles mild steel plates (plain or chequered ) channels square cut or notched ( ordinary and counter sunk) forming holes , without any attatchment (Fe-410-W(GdeE-250) quality 'A', complete all as specified and as directed.
M&L for removing complete Aluminium Partition from site carefully including glass & board , etc. and refixing the same after laying of floor tile complete all as specified and directed.
M&L for providing plain cement concrete, type B-1, 1:2:4 (using 12.5 mm graded stone agg) as in roof kerbs, padding, rounded or chamfered on edges complete all as specified and directed.
M&L for guniting of spalled/corroded reinforced cement concrete surface,i.e column, beam, slab, chajja, comprising of chipping of spalled and loose concrete, cleaning rust form reinforcement by sand blasting, scrubbing down concrete surface with wire brushes, cleaning with water; allowed to dry and applying a layer antirust chemical of fosroc or equivalent on all exposed reinforcment followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited; applying two layers of guniting over steel welded wire mesh having 5mm dia of wire and aparture 50mm, total thickness of gunite not exceeding 60mm thick (average thickness) in cement mortar 1:2 using OPC 43 grade weight cement duly mixed with polycrete admixture @2%by weight of cement or as per manufacturer's instruction and finally applying cement plaster over guinite surface of required thickness to give even uniform and smooth finish conforming to proper geometrics in cement mortar 1:3 to match with the existing suface as in sides and soffits etc of slabs, chajjas,fins. fascias, parapets,lintels,columns& beams etc with and including necessary scaffolding, shuttering, chases to brick work or RCC members etc, complete all as specifed and all as directed. Note-GI wire shall be insert into RCC member by doing hole then inject HILTIHIT RE 500 into the hole before guniting.
Taking down chowkhat or frame without taking off shutters of any description n.exc 1.5 sqm each complete all as specified and directed.
Description of Work / Item(s)
Amount
Internal Electrification
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc shall be measured and paid separately) and making good disturbed surfaces of wall floor etc complete all as specified and as directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, ZHFR, 1100 Volt grade, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 25mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No. 4 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No. 4 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No. 4 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.Make-Polycab/Havells/Finolex. .
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.Make- Anchor Roma /Legrand/indoasian
S&F in replacement modular bell push, 6 Amp, 1 Module complete all as specified and as directed. Make: ANCHOR ROMA/LEGRAND/CRABTREE
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular switch with indicator 1 way, 16 Amp, 1 Module, complete all as specified and as directed. Make: ANCHOR ROMA/LEGRAND/CRABTREE
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular Fan step regulator, 120W - 1 module complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement Bell ding dong, AC, 230 Volts, fixed in position & connecting complete all as specified and as directed. Make-Anchor Roma /Legrand/Crabtree
S & F in repair Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed. Make-Anchor/Havells/Kinjal
S&F in replacement modular cover plate with frame, 1 or 2 module complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 1 or 2 modules complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement module metal flush box, 12 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement sub main wiring with 2 runs of 2.5 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor cable ZHFR drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Make- Polycab/Havells/Finolex. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor,cable ZHFR drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Make- Polycab/Havells/Finolex. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor,cable ZHFR drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 6 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Make- Polycab/Havells/Finolex. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
M&L in repair for sub main wiring with 2 runs of 10 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper cable ZHFR conductor drawn through concealed conduit including PVC rigid conduit 32mm medium grade as per ISS and one run of 10 sqmm size earth wire PVC insulated copper conductor complete all as specified and directed.(Note Two runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit. Make- Polycab/Havells/Finolex.
Supply, fixing and connecting in replacement recessed mounting back- lit LED 2X2, not less than 30 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Lumen efficiency 120 Lm/watt not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours @ L70B50,IP20,UGR<19 THD<10% complete with all accessories as required complete all as specified and as directed.
Supply, fixing and connecting in replacement recessed mounting bottom opening LED 2X2, not less than 30 watt LED Cleanroom IP65 ( from bottom) zero maintenance luminarie having highly translucent opa diffuser with Aluminium Frame for POP/Gypsum Board is a perfect energy saving for hospitals , size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Lumen efficiency 120 Lm/watt not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours @ L70B50,IP20,UGR<19 THD<10%complete with all accessories as required complete all as specified and as directed.
Supply, fixing and connecting in replacement of Slim LED Batten not less than 10 watt with Surface/Wall Mounted integrated LED 2 feet Fitting Aluminium housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen efficiency 120 Lm/watt not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours @ L70B50,IP20,UGR<19 THD<10% complete with all accessories as required complete all as specified and as directed.
Supply, fixing and connecting in replacement of Slim LED Batten not less than 20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Aluminium housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Lumen efficiency 120 Lm/watt not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours @ L70B50,IP20,UGR<19 THD<10% complete with all accessories as required complete all as specified and as directed.
S&F in replacement Bldg security light fitting LED 25 Watt, highly efficient IP66 LED, high power having aluminium pressure die cast housing and PC cover in the front and high power lens for batwing light distribution with electric connection with suitable size of PVC insulated copper wire including GI bracket 1.5 Mtr with clamps and bolts Lumen efficiency 120 Lm/watt not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours @ L70B50,IP20,UGR<19 THD<10% complete with all accessories as required complete all as specified and as directed.
S&F in repair modular blanking plate, 1 Module complete all as specified and as directed.
S&F in repair PVC T-COVER complete all as specified and as directed.
M&L Cutting chases, pinning in, including making good in cement mortar 1:3 including painting to match with the existing surface as in edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concealed conduit wiring, etc, cutting not exc 10 cm girth complete all as specified and as directed.
S & F in repair Thermal magnetic MCCB with Electronic Earth leakage module 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed.Make -Legrand(420076) / ABB /Schneider
S & F in repair Thermal magnetic MCCB with Electronic Earth leakage module 415 V, 100 Amps, 25 KA, 4 Pole complete all as specified and directed.Make - Legrand(420075)/Havells/Schneider
S & F in repair MCB 4 pole,10KA,C-Curve 240 Volts, 63 Amps complete all as specified and directed. Make-Legrand (408702) / Havells /Schneider
S & F in repair MCB DP,10KA.C-Curve,240 Volts, 40 Amps complete all as specified and directed. Make-Legrand(408637) / Havells / Schneider
S & F in repair MCB DP,10KA,C-Curve, 240 Volts, 63 Amps complete all as specified and directed. Make-Legrand(408639) / Havells / Schneider
S & F in repair MCB SP,10KA,C-Curve, 240 Volts, 63Amps complete all as specified and directed. Make-Legrand(408598) / Havells / Schneider
S & F in repair MCB SP,10KA,C-Curve, 240 Volts, 40 Amps complete all as specified and directed. Make-Legrand(408596) / Havells / Schneider
S & F in repair MCB SP,10KA,C-Curve, 240 Volts, 20Amps complete all as specified and directed. Make-Legrand(408593) / Havells /Schneider
S & F in repair MCB SP,10KA,C-Curve240 Volts, 16Amps complete all as specified and directed. Make-Legrand(408592) / Havells / Schneider
S & F in repair MCB SP,10KA,C-Curve 240 Volts, 10Amps complete all as specified and directed. Make-Legrand(408590) / Havells /Schneider
S & F in repair RCBOs, double pole , 240 Volts, 63Amps , 100 mA , for earth leakage, Overload & Short- Circuit Protection , IP 20 Protected terminals and sliding shutters , colour coded On / Off indication and front face indication for earth leakage fault complete all as specified and directed. Make-Legrand(411335) / Havells / Schneider
Supply, installation, commissioning and testing in replacement of LED based ceiling suspended double dome Operation Theater Light with provision only for Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601-2-41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring from and hanging arrangements as per manufacturers guidelines with following specifications :-
TECHNICAL SPECIFICATION MAIN DOME SATELLITE DOME Intensity @ 1 Meter (Lux) 1,60,000 + 10% 1,60,000 +10% Adjustable Field diameter (cm) 14-38 14-38 Depth of illumination L1+L2 (cm) > 100 > 100 Color Rendering Index (CRI) (Ra) 95 + 3% 95 + 3% Color temperature (K) 4,500 + 10 % 4,500 + 10 % Intensity control (%) 25-100 25-100 Type of field focusing control By sterllizable handle By sterllizable handle Type of Intensity control By control panel on lamp head By control panel on lamp head
ELECTRICAL & MECHANICAL SPECIFICATIONS Power Supply input voltage (V) 220-230 V Power Consumption (W) < 150 Frequency (Htz) 50/60 Dome Diameter 500-700 mm LED service life (hrs) > 40,000 complete all as specified and directed Make :Dr Mach/Hospedia medicare/ Stryker.
M&L for Inspection , cleaning and testing of LED 50 Double Dome Unit rewiring of the entire unit , Revalidation of the internal circuitry and control panels for the proper functionng of the unit and complete inspection all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as directed. Note:- The unit rate quoted shall be include for necessary excavation and earth work , earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit & Pit cover, funnel with wire mesh including GI medium grade watering pipe 15mm bore & 25 mm dia for supporting of earth strip/wire.
S & F in repair for load line distribution board double door type, VTPN 4 way,IP-43,IK-09, complete suitable for accomodating upto 125 Amps MCCB(with earth leakage) with incomming frame four pole , including bus bar, neutral link, blanking plates etc complete all as specified and directed.Make : Make : Legrand Model: 5077 45 or equivalent Model of Siemens/ Schnieder.
S & F in repair for load line distribution board double door type, VTPN 8 way,IP-43,IK-09, complete suitable for accomodating upto 125 Amps MCCB(with earth leakage) with incomming frame four pole , including bus bar, neutral link, blanking plates etc complete all as specified and directed.Legrand 507747 /or equivalent Model of Siemens/ Schnieder.
& F in Outdoor Vertical distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, VTPN 8 way with 200 Amps rated copper bus bar, 415 Voltswith provision of MCCB(With Earth leakage) 125 Amps,4P,25 KA,earth bar IP54 protection,flush to wall complete all as specified and directed. Make : Legrand Model: 507752 or equivalent Model of Siemens/ Schnieder. No. 24000/-S
S & F in outdoor Vertical distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, VTPN 4 way with 200 Amps rated copper bus bar, 415 Voltswith provision of MCCB(With Earth leakage) 125 Amps,4P,25 KA,earth bar IP54 protection,flush to wall complete all as specified and directed. Make : Legrand Model: 507750 or equivalent Model of Siemens/ Schnieder.
S & F in repair for distribution board double door type, SPN, 8 way,IP-43,IK-09, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed. Make-.Legrand 507611 /equivalent Model of Siemens/ Schnieder.
S & F in repair for distribution board double door type, SPN, 12 way,IP-43,IK-09, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed. Make-.Legrand 507612/equivalent Model of Siemens/ Schnieder.
S& F in repair Exhaust fan 300 mm sweep 240 Volt Heavy duty (Iron), 1400 RPM , Air delivery 1300 CMM with self closing louver frame connection with flexible PVC copper wire from ceiling rose to exhaust fan including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete with minimum two year warranty on Product all as specified and directed.MAKE- MAXX AIR 300 MM METALLIC GREY EXHAUST FAN BAJAJ/ Havells/ CG Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
Supply and Fixing in repair Geysers of cap. 25 Ltr, five star BEE rating , Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell Glass lined enamel coated incoloy heating elements , temperature indicating dial ,adustable thermostate konb, tank design is suitable to withstand 8 bar pressure, shock resistant ABS outer body automatic cutoff , including electrical and water connection with hot and cold water connection pipe (PVC type) and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete with minimum two year warranty on Product all as specified and directed. Make: BAJAJ (CALENTA )/ HAVELLS/ /USHA.Note :- Old unserveciable Geyser will be deposited to MES store yard.
S& F in repair PVC exhaust fan 250 mm sweep 240 Volt, 1325RPM , Air delivery 500 CMM connection with self closing louver frame flexible PVC copper wire from ceiling rose to exhaust fan including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed. Make:-Havells/Bajaj/Orient/Usha Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
S&F in repair Wall/ Cabin fan of sweep 400 mm, 240 volts,1350 RPM , Air delivery 75 CMM w with all connected accessories complete all as specified and as directed Make:-Havells/Bajaj/Orient/Usha Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
Supply and installation testing and commissioning of wire mesh cable trays of size CF54/100, including all accessories , manufactured with a longitudinal 'T' welded, safety edge, constructed with 50x100mm mesh configuration with all accessories including of same finish as per site requirement, Supports, brackets or hangers designed, mechanically tested & supplied by the wire cable tray manufacturer shall be used complete all as specified and as directed. Make : Legrand Cat Part No 000073 or equivalent Model of Make- Schneider/ Siemens
S&F in replacement console for cable tray provided here in before complete all as specified and as directed. Make : Legrand / Schneider/Siemens.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm complete all as specified and as directed.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm complete all as specified and as directed.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm complete all as specified and as directed.
Fire Fightings
Supply, Installation, Testing & Commissioning of Analogue Addressable 4 Loop Fire Alarm Control Panel expandable via plug-in loop driver boards, loop current 500mA maximum per loop, dual flash based microprocessor, supports to connect wired and wireless 126 Detector/devices (Min 120 Detector) in each loop via fully digital communication protocol, equipped with a white backlit display (1500 Character/240x64 pixel resolution/10" Touchscreen) graphical LCD Display with atleast 6 lines of information, 400 fire zones (soft zones), fully programmable via alphanumeric keypad or configuration software without using any king of DONGLE/LICENCE/SPECIAL CABLE, dediacted USB and RS-232 serial port for direct or PC connection. 10500 events storage, loop current 500 mA, panel shall be equipped with in-built multi-meter for live monitoring of loop current, earth voltage, loop voltage etc., installer's logo application, inbuilt fault-tolerant network card to network with compatible addressable panel(s) and repeater panel(s), capable to connect maximum 200 network nodes on a standard network, features battery charger status and temperature, supports programmable cause / effect on outputs, panel housing meets min IP30 ingress protection classification finished in RAL 7035, The panel shall support more then one OEM protocol to allow user of using other make detector & devices at later stage. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). The panel shall have provision to connect with SCADA. Approved by: British Standards Institute (BSI) and Vertrauen durch Sicherheit (VdS), Independently certified as complying with requirements of BS EN 54 Part 2, 4, and 13. Make : Advanced(UK), Argus, Godrej, Schneider.
Supply, Installation, Testing & Commissioning of Active Repeater Panel (Remote Control Panel) with white backlit (240x64) graphical LCD display, incorporates function buttons for Silence, Mute, Resound, Reset and Disable/Enable, flash memory and advanced graphical display allows it to be easily configured to operate in virtually any language, with any character set and allows for the installer’s logo and company details to be displayed on the LCD display during normal operation. Networked for system display and control, in-built fault-tolerant network card to network with compatible addressable panel(s) and repeater panel(s), fully on-site programmable via alphanumeric keypad or configuration software, panel housing meets min IP30 ingress protection classification finished in RAL 7035. Approved by: British Standards Institute (BSI) and Vertrauen durch Sicherheit (VdS), Independently certified as complying with requirements of BS EN 54 Part 2 & 4. (Make : Advanced(UK), Argus and Schrack )
Supply, Installation, Testing & Commissioning of RF translator wireless device which can control upto 32 detectors modules or signalling devices, configuration through manual or PC software, up to 32 fully intelligent wireless field devices. Operating at frequency of 865 MHz. status indication via 3 LEDs, IT communicates with the control panel via the loop, radio transmission range 150m in free air, operating frequency channels 7, all as specified and directed. Approval by IMQ for EN54-17, EN54-18 & EN54-25. ((Make : Advanced(UK), Argus and Schrack )
Supply, Installation, Testing & Commissioning of RF expander wireless device, two orthogonal antennas for safe radio communications, operating at frequency range of 865 MHz, 7 bi-directional data channels, range of RF transmission is 150 metres in free space can boosted , operating frequency channels 7, all as specified and directed. Approval by IMQ for EN54-18 & EN54-25. (Make : Advanced(UK), Argus and Schrack )
Supply, Installation, Testing & Commissioning of optical detector radio-linked optical detector (smoke) operates with an optical sensing chamber based on the principle of scattered light sensor. The detector communicates with a fire detection control panel in loop technology via the loop RF interface. Two lithium batteries are accommodated in the detector base one as backup. The two coloured LED indicator with 360 visibility. Mechanical theft protection in the base. Radio transmission of 150 m (in free air), operating at de-licensed frequency range of 865MHz all as specified and directed. Approval by IMQ for EN54-7 & EN54-25. (Make : Advanced(UK), Argus and Schrack )
Supply, installation, testing & Commissioning of wireless Analogue Addressable Heat detector. Each sensor is fitted with a reed switch facility allowing testing using a magnet, The detectors parameters are programmed via the Translator Module via a PC link, Communication range with the Translator Module is up to 150 Mtrs in open Area , Bi-directional wireless communication with self-optimising wireless frequency and amplitude Adaptive signal processing helps with the elimination of false alarms .Automatic wireless channel hopping, Fully intelligent with high reliability and sensitivity Flexible on site device adjustment Makes additions to existing wired systems easy and cost effective Utilises standard low cost lithium battery technology Fully monitored primary and secondary power sources complete all as specified and as directed by Engr-in Charge.Approval by IMQ for EN54-7 & EN54-25. (Make : Advanced(UK), Argus and Schrack )
Supply, Installation, Testing & Commissioning of analogue addressable optical smoke detector with inbuilt isolator and standard base working on pure light technology, It shall have multiple settings with min five different EN approved modes for optical sensitivity adjustment from 1.4%/m to 2.4%/m. 360° Visible Tri-coloured led for Normal, Fault and alarm condition, addressing shall be posiible by means of Soft addressing as well as Hard addressing. It shall have Compensation to drift and transient rejection and complies with the essential requirement of the EMC Directive, designed for IP44 requirements and approved to operate in –40°C to +70°C temperature, It shall be possible to insert and remove detectors by a single push twist movement, base shall have special locking tool feature to prevent loosening of detector on its own.. Approved by LPCB for EN 54-7 & EN 54-17 standard. Make : Advanced(UK), Apollo, Argus, Godrej, Schneider and Schrack.
Supply, installation, testing & Commissioning of Analogue addressable Wireless Resettable Manual Call Point, Bi Directional wireless communication Fully intelligent Utilises standard low cost lithium battery technology, Long battery life, Resettable Element, Clear ‘device activated’ warning flag, High reliability, automatic channel hopping self-optimising wireless amplitude and frequency and fixing with suitable size of MS conduit pipe along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. Communication range with the Translator Module is up to 150 Mtrs in open Area complete all as specified and as directed by Engr-in Charge.Make : Advanced(UK), Apollo, Argus, Godrej, Schneider.
Analogue Addressable Wall Sounder weather proof as standard and is equipped with 3 levels of volume adjustment and 32 recognised tones which can be set locally at the sounder. When configured onto a Translator, the Wireless Sounder is fully addressable and benefits from intelligent control, test and monitoring complete all as specified and as directed by Engr-in Charge.Make : Advanced(UK), Apollo, Argus, Godrej, Schneider and Schrack
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electrical control cable with stranded copper conductor of size 1.5Sqmm 2 core complete all as specified and directed.( Make :- Polycab / Havalls/ Finolex/ RR kabel /KEI)
Supply, fixing, testing and commissioning of 2 KGS capacity Novec1230/FK-5-1-12 DLP assembly including automatic valve, push in connector for tube, 2 KGS cylinder with PESO approved FK-5-1-12 gas cylinder and mounting bracket with all accessories as required. Gas shuold be filed in PESO approved plant MAKE : FIRETRACE/KANEX/UTC
Supply, fixing, testing and commissioning of 4 KGS capacity Novec1230/FK-5-1-12 DLP assembly including automatic valve, push in connector for tube, 4 KGS cylinder with PESO approved FK-5-1-12 gas cylinder and mounting bracket with all accessories as required. Gas shuold be filed in PESO approved plant MAKE : FIRETRACE/KANEX/UTC
Supply, fixing, testing and commissioning of End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check Valve, Pressure Gauge and fitting to connect to sensor tubing. Tube connection 6mm, length 2.77``/71mm, Gauge scale :0-20 bar. Fitting made by brass (plated /unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C. Make :As per standard
Supply, fixing, testing and commissioning of Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars. Switch Type SPST, Normally Open, Electric Rating : 120/240 VAC-375 VA, 24 VAC-125 VA, Open 160 psi y-7, Close 185 psi y-5,Pressure switch + adaptor / 5bar. Make :As per standard
Supply, fixing, testing and commissioning of T Connection, Brass, Nickle plated, for 4x6 mm Sensor Tube, quick and easydisassembly using special tool, working pressure 15 bars at 15 Deg Temperature, temperature range-40 Deg C till + 80 Deg C, Elastometric Sealings, External Diameter tube 6mm. Make :As per standard
Supply, fixing, testing and commissioning of End of plug used for fitting at the tube end to terminate the point. Fitting made by brass nickel plated material with Elastomeric sealings, Temperature range TS -20 Deg C till+ 60 Deg C, Maximum working pressure 25 Bars, made as per PED pressure equipmentDirectives Make :As per standard
Supply, fixing, testing and commissioning of Linear pneumatic heat Detection Tube with all necessary fittings & supports to complete the works etc as required. UL listed tube as per UL521. MAKE : FIRETRACE/KANEX/UTC
Supply, fixing, testing and commissioning of master control unit for controlling system including pressure switches,buzzers , electronic hooters,electrical wiring and other all necessary accessories as required to make entire system functional. Make :As per standard. Note:- The contractor shall produced OEM authorization/support letter.
Deep Cleaning
M&L high pressure washing provide Specialized solutions for typical horizontal and vertical surfaces,types of horitontal surfaces managed include granite, marble terrazzo, kota stone, Glass Surface with 1. Disinfectant Chemicals from Diversey (R2,R3,R4,R6) Alcohal 60-90% ethyl or isoproyl, Calcium Hypochloride, Sodium hypochloride,Iodophors,Quaternary Ammonium,using some of the hard chemicals to remove carbon and Hard Stain Marks. equipment shall be used 1. Floor Dish Machine 2.Vacuuming Machines. 3. Different Kinds of Pads and Greets will be used to clean the floor surface such as Red, White, Green& Black Pads 4. Hand Machines and buffing Machines. 5. All kinds of tools required for the Jobs (Dusters, Brooms, Mops, Wiper, Hand Scrubbing Tools etc. ). Removing all the un wanted materials from the O.T and I.C.U under the supervision of Hospital team Member.The job shall include repeated removal & disposal of unwanted burnt smoke/waste item as on site during various phases - repair/removal /replacement of B/R and E/M works site under supervision of medical attendant. The job shall include the cleaning after completion of all associated works of AC/Civil/E/M works required to restore the services. The complete job shall be executed by superspecialized facility provider such as Urban clap/Jaz facility/Banzai solution pvt Ltd/ sunrise pest management services/MS facilty services.
Air Conditioning
Supply, Installation, testing and commissioning of VRF type AC units, Outdoor type, Capacity 22HP, Air cooled, 100% inverter Scroll compressor based VRF system using R410 refrigerant Gas, including first fill of refrigerant. The system shall be suitable for cooling and heating both purposes and shall work on 3-phase , 415V, 50Hz AC power supply. Minimum Two Highly Efficient Inverter Scroll compressors with accumulator, air cooled condensers made with corrosion proof blue fins and its fan with motors, microprocessor controls, control panel along with internal control and power wiring, internal interconnected refrigerant pipes, charging ports with precharged non CFC gas of R 410A. The unit shall be Heating-Cooling both type and No deration up to 43° C and non stop cooling up to 56 °C. Minimum COP(100% Capacity Ratio) at AHRI will be more than 3.96. All above specification should be submit by OEM with Sign Stamp to Respective MES Engineer on there Letter Head . Condition will be Quoted rates complete all as specified and directed.Capacity- 22HP Model-IVRFB-22THA/B
Supply, installation, testing and commissioning of AHU Expansion Kit to Integrate the AHU System with VRF ODU Capacity- 20Tr (Model No. VAEKIT-200)
S & F Wired Remote control for VRF type AC unit complete all as specified and directed. Make- Blue Star Model No-CDCO-D170-00
Supply, Installation, testing and commissioning of Interconnecting refrigerant copper pipe ,fitting like elbow ,couplers ,tee , joints, brass fitting,"U" loops etc work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with glass cloth between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger at a distance of 1m and all external piping shall run in covered cable tray and the exposed piping should be insulated with factory backed glass cloth for mechanical and UV protection as per specifications complete all as specified and directed: -Make- Mandev ,Rajco, Max flow Good Grade nitogen bleeding (at the rate of 3-4L per Min) while making brazing of Copper pipe with min 2% silver alloy brazing rod in Presence of MES Engineer.
(a) 28.6 mm dia with 19mm thick insulation
(b) 15.9 mm dia with 13mm thick insulation
Supply and fixing Rigid UPVC piping complete with fittings, supports and duly covered with 9 mm thick closed cell nitril rubber insulation complete all as specified and directed. Note : Providing and fixing in position the following size of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category.
Supply and charging Additional refrigerant gas of R410A complete all as specified and directed.
S & F weather proof 4 Pole encloser consisting of 40 Amp 4 Pole MCB, 10 KA, complete all as specified and directed.
S & F Metal encloser 4 Module consisting of 40 Amp MCB single Pole, complete all as specified and directed.
M&L for control wiring with 4 core X 16sqmm , ZHFRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Traycomplete all as specified and directed Make : Finolex/Havells/Polycab (Note : Four run of wire with PVC conduit will be considered as one Length.)
M&L for control wiring with 2 core X 1.5sqmm , ZHFRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed Make : Finolex/Havells/Polycab (Note : Two run of wire with PVC conduit will be considered as one Length.)
M&L for control wiring with 2 core X 0.75sqmm sqmm , Sheilded wire, twisted pair & Sheilded 2 Core Sheathed Wire, Sheilding use for Earthing Connection, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed Make : Finolex/Havells/Polycab
Supply and fixing of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel complete all as specified and directed.
Supply and fixing of 125mm deep Antivibration Flexible Joints made out of imported fire retardant fabric with extruded aluminium complete all as specified and directed. frame/ flange on both sides for Outdoor Units & AHU.
Supply , re-assemble and erection of Aluminium Ducting with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engg -in-charge including making of hole in any type of wall and making good with plastering work, masonary work and necessary MS channel supports complete all as specified and directed.
(a) 24 Gauge GI Sheet
(b) 22 Gauge GI Sheet
Supply & erection in replacement 19 mm thick nitrile duct thermal insulation with Aluminium foil, non - fibrous, fire retardant, closed cell, tri-dimensional, chemically cross linked polyethylene foam , confirm to class O' for fire propation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
S&F in replacement acousting lining of supply air ductung complete with GI frame , tissue paper, 26 Gauge perforated Aluminium Sheet, 25mm thick , of density 32 Kg/cum fiber glass insulation complete complete all as specified and as directed.
Supply, installation, testing and commission of UL-555 motorized fire dampers complete with smoke detector/ thermister linkage etc in AHU Room Supply Air Ducts as required for operation complete all as specified and directed.
Supply, installation, testing and commission of Actuator with control panel in AHU Room Supply Air Ducts as required for operation complete all as specified and directed.
Air Handling Units DX Type for OT-7 Area (New OT)
Supply, Installation, testing and commissioning of Smart AHU(Air Handling Unit) Floor Mounted type, 100% Fresh Air Type (TFA), Double Skin Casing consist of Outer Skin of 0.6mm Pre Coated GI, Inner Skin of 0.6mm Plain SS-304, Frame work consist of Thermal Break Aluminium profile with thermal barrier, insulated panels of Thickness 45mm CFC Free PUF injected (Density: 40 kg / Cu. m.), Drain tray material consist of 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation, GSS Base Channel. Coil Casing / Blank offs SS-304 with Copper tube(IGT) of thickeness 0.5mm, Fins Thickness of 0.15mm of Plain Copper with hydrophilic coating 11 Nos.Per Inch. with filter : Media of Filters-Synthetic (non woven type) / Fiber Glass for (EU-13),Efficiency of Pre-filters (EU-4)-90 % down to 10 micron, Efficiency of Fine-filters (EU-7) - 99 % down to 03 micron, with Motor - EFC Squirrel Cage IP 55 Protected VFD Compatible induction motor. DX Coil: (IGT):- 02 Nos (01 No for 44 HP VRF Out door unit & 01 No for 44 HP VRF stand by out door Unit (a) Make of coil - Zeco (b) Coil Casing / Blank offs - GI (c) Material of Tube - Copper (d) Tube Dia (mm/Inch) - 9.52mm / 3/8" O.D (e) Thickness of tube (SWG/mm) - 25 SWG / 0.5 mm (f) Header Material - Copper (g) No. of Fins per inch (FPI) - 11/12
(h) HW Coil:- 01 No (j) Make of coil - Zeco (AHRI certified as per test standard ARI-410 & UL certified for safety) (k) Coil Casing / Blank offs - GI (l) Material of Tube - Copper (m) Tube Dia (mm/Inch) - 12.7 mm / 1/2" O.D (n) Thickness of tube (SWG/mm) - 27 SWG / 0.41 mm (o) Header Material - MS Header with MS adaptor (p) Thickness & Material of fins - 0.15 mm plain Copper (q) No.of Fins per inch (FPI) - 8/10 FILTERS :- (a) Make of filters - Thermadyne/spectrum/(ZECO-EU-04) (b) Media of filters - Synthetic (non-woven type) (c) 90% down to 10 micron (d) 90% down to 5 Micron FAN & MOTOR:- (a) Fan make - Kruger (b) Motor make - ABB/BHARAT BIJEE/CROMPTON Lower Tier :- (a) Mixing box with Motorized operation FA damper & RA damper in Al constructions with actuator. (b) Filter section with 50 mm thick (EU-4) box type pre filter with 305mm thick (EU-5) bag type fine mounted on common GI filter frame. (c) Coil section with 6 row deep DX cooling coil.(2 Nos),With single distributor. (d) Coil section with 2 row deep hot water heating coil- 01 No (e) Fan section with SISW Backward curved plug fan & Motor (IE-2). (f) Motorized operation Exhaust Air damper in Al constructions, with actuator.
Operating & Physical Parameters (Lower):- (a) Flow Rate- 3500 CFM (Lower Tier) (b) TPS (mmwg) - 125 (c) Unit Model - ZDS-40 (d) Fan Type- PLUG FAN-400 (e) FAN Model - BNC-P 400 (f) Fan Qty - 1 (g) Fan Dia - 400 (h) Fan RPM - 2669 (j) Motor RPM - 2880 (k) Frequency - 46 (l) Shaft Absorbing Power - 3.04 (m) Motor Rating (Kw) - 3.7 (n) Motor Qty - 1 (o) Motor Pole - 2 (p) Coil area (sq. ft) - 7.0 (q) Cooling coil RD - 6.0 (r) Heating coil RD - 2.0 (s) Filter Area: 8 Sqft Upper Tier :- (a) Return air intake section with manually operated RA damper in Al construction. (b) Manually operated Exhaust Air Damper in Al constructions. (c) Fan section with SISW Backward curved plug fan & Motor (IE-2). (d) Motorized operation Exhaust Air Damper in Al constructions, with actuator
Operating & Physical Parameters (Upper Tier):- (a) Flow Rate- 3500 CFM (Upper Tier) (b) TPS (mmwg) - 30 (Upper Tier) (c) Unit Model - ZDS-40 (d) Fan Type- PLUG FAN-540 (e) Fan Qty - 1 (f) Fan Dia - 450 (g) Fan RPM - 1367 (h) Motor RPM - 1440 (j) Frequency - 47 (k) Shaft Absorbing Power - 0.801 (l) Motor Rating (Kw) -1.1 (m) Motor Qty - 1 (n) Motor Pole - 4
Supply and installation, testing, commissioning Outdoor type feeder piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specifed abd directed & Connisting of the following equipments:- (i) MCCB, 4 pole , 25 KA , 125 Amps adjustable to thermal Magnetic Release -01 No ( Incomming) (ii) MCCB , 4 pole , 16 KA, 63 Amps -05 No (Out going) (iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set (iv) Energy meter - 01 No (v) Solid aluminium bus bar 400 Amp for 3 phase , 200 Amp for neutral (vi) PCC and block Mesonry work for grouting of panel complete all as specified and directed
Supply, Laying, jointing and testing in repair of electric cable XLPE 3.5 Core 50 sqmm insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.
M&L in repair for Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including provision of 40 mm GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, Charcol, salt, funnel, wire mesh, GI strip Up to 7.5 mtrs length complete all as specified and directed.
Supply, install, testing and commissioning of Mini Pleat HEPA Filters for operation theatres (as per UL 900 fire rating) in Aluminum frame flange type , filter media consisting of Micro Fibre Glass (imported) protected with Aluminum mesh on both sides having efficiency better than 99.97% down to 0.3 microns particle size with I.P.D < 15 mm WG, F.P.D >= 50 WG complete all as specified and directed. Note: DOP SITE TESTING OF HEPA FILTERS (a) Testing will be done with the Help of Photometer and smoke generator. (b) Room validation will be done with particle counter. (c) Velocity of outlet of HEPA filters shall be done with velocity meter. compressed air and all other materials for testing shall be arranged by the contractor.
S&F in repair 50mm thick box type Pre-Filter (EU-4) Synthetic media type flange type (non woven type ) efficency - 90% down to 10 micron with complete all fitting for AHU and 50 mm wg static pressure with rod support fabrication with GI/Aluminium frame, suitable for AHU of make fedders lloyd all complete as specified & directed. Make for filter :- Athlete/ AAF/ Fredenberg
Supply and fixing of fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct with nuts , bolts complete all as specified and directed.
Supply, installation ,testing and balancing in repair square shape supply air diffuser with removable core and antismudge ring and volume control dampers , power coated , extruded aluminium construction complete all specified and as directed.
Supply, installation ,testing and balancing in repair square shape supply Return air diffuser with removable core and antismudge ring and without control dampers , power coated , extruded aluminium construction complete all specified and as directed.
Supply and fixing in repair GI Pipe 50 mm dia heavy class fixing on wall for ducting supports including making of hole in any type of wall and making good with plastering work, masonry work complete all as specified and directed.
Supply, installation, testing and balancing of Return air grill without dumper powder coated extruded aluminium construction in repair complete all as specified and directed.
Supply, installation, testing and balancing of Supply air grill with aluiminium dumper powder coated extruded aluminium construction in repair complete all as specified and directed.
Dismantling of existing water cooled central AC plant complete upto 2 x 12.5 TR capacity with AHU capacity 3500 CFM complete with connected pipe lines (Chiller & condenser), insulations, valves and strainers, motors, cooling tower pipe lines, disconnecting power and contrrol wires of complete plant, dismantling of existing AC plant contrrol panel dismatling of existing AC plant control panel, dismantling/ Cutting pipe supports and breaking existing foundations of chiller pumps, condenser pumps & Chiller units 02 Nos each with arrangement of necessary manpower & T & P for transporting it upto 6 KM at MES store yard for further disposal complete all as specified and directed.
Supply, installation, testing and commissioning of Communicable type Temperature & RH 7 inch Touch Screen display with set point adjustor for OT.
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch. The controller shall have 16 inputs/outputs inbuilt and can be expandable up to max 40 points by Input/output Modules. The DDC shall have 300 MHz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. DDC Controller shall be equipped with a battery-free real-time clock with backup for min 7 days using super capacitor. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). It should have WLAN interface, Cloud connectivity for Remote access and inbuilt port for POT for local interface.
The above shall be housed in vandal proof, lockable & secure MS Cabinets to be Supplied along with all necessary switchgear protections as required.
Controller for OT AHU system ( Max 1 AHU in 1 DDC)
Field instruments:- Supply, installation, testing and commissioning of the following sensors / Transducers / transmitters
Differential pressure switch for Blower and Filter Status
Duct type temperature and RH Sensor
Differential Pressure Sensor Air for OT Room
Note :- Item ser No 124 of BOQ is pertains to Air Flow management system . Contractor should visit site for OT No 03 , 04, 07 & 09 before quoting rate. The quoted rate is inclsuive for necessary modification, Repair & replacement of sensors, control and power wiring, VFDs , control panels, acuators , 3 way valves, PLCs , Dihumidifer etc . For smooth functioing of OTs Air flow management items which are not mentioned in Item ser No 124 and suggested by OEM will provide by contractor without any extra cost. Quoted rate is inclusive for testing, commissioing and calibration of all sensors, PLCs and other electrical and electronic devices.
Conduits and cables
Supply, installation, testing and commissioning of 25 mm dia. PVC ZHFRLS Conduit complete all as specified and directed.
Supply, installation, testing and commissioning of 2 core x 1.5 sq. mm, Shielded ZHFRLS, ATC Cable complete all as specified and directed.
S&F in replacement Acoustic treatment/ lining of area of AHU room with 22 Gauge, GI channels of 50x50 mm size fitted at 600x600mm girds, fitted with 50mm thick, 32 Kg/cum fibber glass insulation, covered with fibber glass tissue and 24 Gauge Aluminium perforated sheet as required, The joint shall be with minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering, All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed.
Supply, installation, testing and commissioning, Ultra Sonic (Mist) Humidifier Model- RM-3 Capacity- 3 LPH, Type :- Horizontal (Indoor Unit), Construction:- Tank made from 1.5mm thick stainless sheet 304L grade sheet, Electrical panel constructed in 18 Gauge CRC Sheet, Controls:- (a) Low Level Cut-out- Mini Float Switch (b) Auto Drain System - Timer with Motorized valve for auto flushing (c) Filter Assembly - 5-10 micron air filter and 5-10 micron water filter. Mist Outlet fan with throw type blade Electrical panel:- Power Supply (S.M.P.S), Contactor, MCB Relay card, connectors, On/off switch with Light, Auto Drain System, Indication for Drain valve / Humidity off/ Supply On/ Low Level. Paint:- Tank - Phiroza blue enamel paint complete all as specified and as directed.
Supply and lay MS pipe for Hot water and drain pipe MS 'C' class 40 mm dia confirming to IS-1239 and IS- 3589 both revised till date as required and as specified and complete with bends, reducers tees, supports vibration pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and complete all as specified & directed.
All as per item No 137 here-in-above but of pipe 50 mm bore.
Supply and fixing in repair 50mm 3 way gun metal modulating valves for AHU complete with linkage modulating actuator with all accessories complete in all respect as specified and as directed
Supply and fixing in repair Butterfly valve 50mm made out of gun metal , with all accessories complete in all respect as specified and as directed
supply and fixing in repair balancing valve 50 mm made out of gun metal, with all accessories complete in all respect as specified and as directed
Supply, installation , testing and commission of Duct mounted inline fans of G.I construction, Complete with centrifugal fan with motor, Canvas connection ai inlet & Outlet complete with MCB & relays. Cabling & earthing (with 5 RM).complete in all respect as specified and as directed
Cleaning of inside surface of supply Ducts of HVAC system by (NADCA certified duct cleaning agency) using high power vacum air compressor, Robotic camera, air hammer, special nozzles, air sweep with other required accessories giving/ showing inspection of duct before and after cleaning of duct using color video inspection complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out the old GI/AL ducting, grill, Hepa filters etc with out disturbing the adjacent and making good the disturb surfaces
Gas Pipe Line Note: (a) The contractor submit the complete drawing alongwith suitable color coding as per industry norms of manifold system and its layout after the successful completion of the project. The facility will be taken by the users immediately after the successful testing and commissioning. (b) The cost of painting the complete manifold system where ever required will not be paid separately but will be deemed to cover in this schedule.
Distribution: Piping Medical graded Copper pipes shall be solid drawn, tempered, seamless, phosphorous deoxidized, non-arsenic and degreased for oxygen service. Distribution Copper Pipe should be Cu- DHP grade half hard and manufactured as per BSEN:13348: 2008 complete as per specification,.
Supply, installation, commissioning and testing of Copper Pipe 28mm x 0.9 mm complete all as specified and directed. Make: MEXLO/RAJCO/MANDEV
Supply, installation, commissioning and testing of Copper Pipe 22mm x 0.9 mm complete all as specified and directed. Make: MEXLO/RAJCO/MANDEV
Supply, installation, commissioning and testing of Copper Pipe 15mm x 0.9 mm complete all as specified and directed. Make: MEXLO/RAJCO/MANDEV
Supply, installation, commissioning and testing of Copper Pipe 12mm x 0.7 mm complete all as specified and directed. Make: MEXLO/RAJCO/MANDEV
Supply, installation, commissioning and testing of semi Automatic Gas Control Panel for Oxygen having left bank and right bank for oxygen supply so that after finishing of one bank the another bank will start with in built alarming system consisting pressure guaze for main supply, left bank and right bank semi- automaticcomplete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply, installation, commissioning and testing of semi Automatic Gas Control Panel for Nitrous Gas having left bank and right bank for Nitrous supply so that after finishing of one bank the another bank will start with in built alarming system consisting pressure guaze for main supply, left bank and right bank semi- automatic complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and Fixing of front insertion type gas outlets for oxygen gas system complete with box and probe all as specified and directed BS Type complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and Fixing of front insertion type gas outlets for vacuum system complete with box and probe all as specified and directed BS Type complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and Fixing of front insertion type gas outlets for Nitrous Oxide system complete with box and probe all as specified and directed BS Type complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and Fixing of front insertion type gas outlets for Medical Air system complete with box and probe all as specified and directed BS Typecomplete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and fixing of oxygen flow meter of 15 lpm capacity with humidifier bottle complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and fixing of digital area alarm system microprocessor based audio visual type alarm for four gas complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and fixing of digital area alarm system microprocessor based audio visual type alarm for three gas complete all as specified and directed. Make: MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and fixing of ward vaccum unit complete with Jar of 600 ml capacity complete all as specified and directed. Make:- MR ENGG/BIOLOGICS/INDIMEDICAL
Supply and fixing of low pressure antistatic tubes complete all as specified and directed. Make: RN/RB
Supply and fixing of isolation ball valves with brass adopter 12 mm OD complete all as specified and directed. Make: RN/RB
Supply and fixing of isolation ball valves with brass adopter 15 mm OD complete all as specified and directed. Make: RN/RB
Supply and fixing of isolation ball valves with brass adopter 22 mm OD complete all as specified and directed. Make: RN/RB
Supply and fixing of isolation valves box including presure guaze and lock and key with brass adopter for 3 & 4 gases complete all as specified and directed. Make: RN/RB
Supply and fixing of bed head panel 3.5 feet including 2 Nos. power switch socket and 2 no normal switch socket for medical equipment with provision of 4-5 gases outlet, IV pole, monitor tray etc.complete all as specified and directed. Make: MR ENGG/INDIMEDICAL
Supply, installation, commissioning and testing of air compressor filtter already air compressor istalled in OT complex complete all as specified and directed. Make: INGERSOLLERAND/ ANESTIVATA
Supply, installation, commissioning and testing of medical air dryer needs to attached with the air compressor of trident pneumatic brandcomplete all as specified and directed. Make: ANESTIVATA
Service, repair and replacement of air compressor ring and piston already air compressor installed in OT complex complete all as specified and directed. Make: ANESTIVATA
Supply, installation, commissioning and testing of genetics air regulator for Air 4 Bar and Air 7 Barcomplete all as specified and directed. Make: MR ENGG/ INDIMEDICAL
M P TYAGI ENGINEERS AND CONTRACTORS
AMIT ASSOCIATES
M/S J J ENTERPRISES
LUMOS INFRA PVT LTD
Airef Engineers Pvt Ltd
NAFREF ENGINEERS PVT LTD
AMIT ASSOCIATES
M P TYAGI ENGINEERS AND CONTRACTORS
LUMOS INFRA PVT LTD
M/S J J ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .