Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.8 L+₹2.3 L (20.4%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹13.8 L+₹2.4 L (20.9%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹14.8 L+₹3.4 L (29.5%)Rejected-AOC 93 61 AGARWAL FARM MANSAROVER JAIPUR 302020 | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹16.6 L+₹5.2 L (45.6%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF LT OH/ UG CIRCUIT AND SWITCH GEARS PANEL BOARD AND OTHER CONNECTED ACCESSORIES AT ZONE-III, MES IB AND HOLIDAY HOME AREA UNDER GE (S) JAIPUR
2023_MES_633446_1
GE(S)/J-50P/2023-24 8849/E8
Open Tender
Civil Works
Item Rate
270 days
Jaipur
E class and category b (i)
9 documents required · 9 mandatory
₹500
Yes
GE (S) Jaipur
₹40,000
Yes
23 Mar 2024
19 Dec 2023
23 Jan 2024
19 Dec 2023
15 Jan 2024
2 Jan 2024
Amount
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches for n.exc 1.5 metre wide and depth exceeding 1.5 mter but not exceeding 3.00 meter for foundation etc or for laying of cable/poles etc and getting out in soft/loose soil complete all as specified and as directed.
M & L Sand cushioning to under ground cable with stone crushed sand and punning to provide a required cover complete all as specified and as directed.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in depth complete all as specified and as directed.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point complete all as specified and as directed.
Dismantling of existing Unsv ACSR conductor of any size from insulators fixed on poles complete all as specified and as directed.
Dismantling of prestressed cement concrete poles complete of any size including PCC foundation and necessary excavation & earth work and making good to distubed surfaces complete all as specified and as directed.
Dismantling and taking down existing LT insulators of any type and size complete all as specified and as directed.
Dismantling of existing stay assembly of any type & size complete including excavation and earth work and demolition of concrete and making good to distubed surfaces complete all as specified and as directed.
Dismantling of cross arms, bracing, supports, clamps, nuts and bolts of mild steel channel or angle sections etc complete all as specified and as directed.
Dismantling/taking out old defective LT UG cable from trench/ on walls/poles/ducts etc of 16 Sqmm sqmm 4 core to 240 Sqmm 3.5 core complete all as specified and as directed.
M&L pre-stressed cement concrete poles, 9.0 metre long with minimum cross section 102 mm x 172 mm at top and minimum cross section 102 mm x 279 mm at bottom, class-10, conforming to IS-1678 complete all as specified and as directed.
M&L stay assembly complete with accessories as shown in electrical plate No. 1 of MES SSR part I, including stay rod of 20 mm dia, MS stay plate 300 mmx500mmx6mm & GI stay wire of 7/8 SWG, bow, PCC 1:3:6 of suitable length as required complete all as specified and as directed.
M&L cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section including bolts, nuts, washers, welding, bending (cold or hot) drilling holes for bolts any shape or size as indicated or directed and inclusive painting with one primer coat of zinc chromate and two coats of aluminium paint complete all as specified and as directed. Note :- MS/GI clamps, bolts, nuts and washers will also be measured under this item.
M&L pin type, porcelain, vitreous china, brown, white or green insulator 100 mm height and 65 mm dia, 1100 volts grade including one galvanised MS spindle, two GI washers and one GI nut, bolt etc conforming to IS complete all as specified and as directed.
M&L shackle type, porcelain, vitreous china, brown, white or green insulator 1100 volts grade of 90 mm dia and 75 mm height including galvanised MS strap of 31 mm x 3 mm size, 12 mm dia insulator bolts, washers and nuts etc conforming to IS complete all as specified and as directed.
M&L for aluminium conductor steel reinforced (ACSR) straining properly on insulator and binding with aluminium binding/ Clamps, for running lines or jumpers etc.of any type and sizes complete all as specified and as directed. Note:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
M&L for straining only existing ACSR of any size/span on existing poles, insulators using proper tensioners and binding with aluminium binding/ Clamps complete as directed. (each length of single conductor measured separately) Note:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
Supply and lay tube GI of size 40 mm dia bore Light grade fixed on poles, walls and ceiling etc. with all fittings for protection of cable in repairs (Clamps for fixing shall be measured and paid seperately)
All as per item No 20 above but 50 mm
All as per item No 20 above but 80 mm
M&L for boring under road/drain by manual/machine method for inserting GI tubing not less than 80 mm dia for cable protection all as specified and as directed.
M&L in replacement earthing with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, with earth strip 25 mm x 4 mm protected by galvanised iron or steel pipe 40 mm bore light grade with Watering pipe 20 mm bore GI medium grade. The rate of earthing shall be inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I.
Trimming of tree branches upto 75 mm dia to clear the route of HT/LT over head lines (any nos of conductors) upto 3m all around fom the conductor including removing the cut branches from site and depositing at places n exc 50m all as directed by Engineer-in-Charge. Note (i) One span from pole to pole of distance not more than 30 meters (approx) shall be considered as one unit. (ii) The frequency of trimming of tree branches shall not be less than 6 months and initial trimming to be carried out with in one month of handing over site and subsequent trimming if required to be carried out with prior written approval GE.
Supply, lay, connect and commission LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strip armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc of size 95 Sqmm, 3.5 Core.
All as per item No 26 above but 70 Sqmm, 3.5 Core
All as per item No 26 above but 50 Sqmm, 3.5 Core
All as per item No 26 above but 35 Sqmm, 3.5 Core
Supply and fix heat shrinkable straight through jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of size 10 - 35 Sqmm 3½ Core
All as per item No 30 above but 50 - 70 Sqmm 3½ Core
All as per item No 30 above but 95 - 150 Sqmm 3½ Core
All as per item No 30 above but 185 Sqmm 3½ Core
Supply and fix heat shrinkable end jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of size 50-70 Sqmm 3½ Core
All as per item No 34 above but 95 - 150 Sqmm 3½ Core
All as per item No 34 above but upto 240 Sqmm 3½ Core
M&L for Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB 63 amp, 16/18 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase, adjustable type including extension terminals and Ics=100%Icu connecting using suitable fasteners, modification/fabrication if any complete all as required at site, as specified and directed.
All as per item No 37 above but 100 amp, 16/18 KA
All as per item No 37 above but 125 amp, 16/18 KA
All as per item No 37 above but 160 amp, 35/36 KA
All as per item No 37 above but 200 amp, 35/36 KA
All as per item No 37 above but 250 amp, 35/36 KA
S&F in replacement of out door (Kiosk type) type LT panel, weather & vermin proof MS sheet housing 3.15 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 200 Amp, 35/36 KA, 415 volts, thermal release, adjustable type (Ics=100%Icu) as incomer and one on-load changeover switch, 4 pole, 415 Volts, 200 Amps & Aluminium bus bar 300 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and as directed.
S&F Bus bar electrolytic grade aluminium of 25×6 mm, mounted on insulators including drilling holes including disconnection & reconnection of cables from existing panel complete all as specified and as directed.
S&F Bus bar electrolytic grade copper of 25×4mm, mounted on insulators including drilling holes including disconnection & reconnection of cables from existing panel complete all as specified and as directed.
S & F On-load change over switch, 4 pole, 415 volts, 100 amp suitable for existing panel including taking down the unsv c/o switch, disconnecting and reconnecting all electrical connections, modification/fabrication if any complete all as specified and as directed.
All as per item No 48 above but 200 Amps
All as per item No 48 above but 400 amp.
S&F in repair LED indicating lamp (Set of three lamps, RYB), 240 volts AC including necessary wiring
S&F in repair Red luminous push button complete all as specified and as directed.
S&F in repair Green luminous push button complete all as specified and as directed.
M&L for cutting/removing damaged Hinge of any size and welding/ fabricating same with best quality replacement spare in the existing panel including making good of existing surface
M&L for Scraping of old steel surface of LT Panel/ feeder panel from both side i.e. inside and outside completely and removing dust and painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. Note:- (i) Second coat should be after agap of 24 hours. (ii) Colour of paint will be decided by Engr-in-Charge.
M&L for repair of PCC base of LT panels with proper brick masonry and cement mortar material and painting with two coats of cement base paints complete all as specified and as directed.
M&L for removal of grass vegetation from beneath the LT panel and nearby places completely.Note:-The frequency of removal of unwanted grass/creepers should be twice a month till period of completion of contract.
M&L for external based paint for earth pit for transformers completely as specified and as directed. Note:- Colour of paint will be decided by Engr-in-Charge.
M&L in repair of broken earth pit and earth pit chamber at LT panels/Transformers with proper brick masonry and cement mortar material including all tools and accessories complete all as specified and as directed.
S&F precast earth pit covers in PCC 1:2:4 Type B-0 using 12.5 mm graded stone aggregate of suitable size complete all as specifed and as directed.
M&L for maintenance of earth pit and earthing of the earth pit below 3 ohm by pouring coal powder and salt together of 25 Kg complete all as specified and as directed.
M&L for replacement of GI Earth strip of size 25X4 mm connecting LT panels,transformers or other installations completely and connecting the pit through anti corrosive nuts and bolts as specified and as directed. Note:- (i) The quoted rate includes replacement of rusted nuts and bolts. (ii) The strip should be burried in ground and exposed part should be insulated through flexible pipes.
Supply, install, testing and commissioning in replacement factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compartmantalised and IP-65 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system complete all as specified and as directed, having bus bar chamber. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron , powder coated, having front and rear openiable hinged double door shuters with aprons for cable entry and locking arrangement complete :- Incoming (a) MCCB 320 amps, 4 pole, 50 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 Nos. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, not less than 60cm long mounted on insulators. (c) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), CT operated 415 volts, 50 Hz AC supply including CTs. -01 set. (d) LED indicating lamps (R, Y & B) -01 Set. Outgoing (a) MCCB 200 amps, 4 pole, 25KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 Nos. (b) MCCB 160 amps, 4 pole, 25KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 Nos. (c) MCCB 63 amps, 4 pole, 25 KA , with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 02 No.
S&F new out door (Kiosk type) LT panel, weather & vermin proof MS sheet housing 3.15 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 250 Amp, 35/36 KA, 415 Volts, thermal release, adjustable type (Ics=100%Icu) as incomer and copper bus bar 300 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections after due approval of panel drawing including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and as directed.
Repairs & Maintenance of APFC panel of capacity 25 KVAR to 150 KVAR including replacement of wiring with copper conductor cable with lugs etc calibration of relay, digital meter complete all as specified and as directed. Note : Unserviceable Spare Parts will be measured & paid separately under respective items of Schedule ‘A’.
Supply only power capacitor 1 KVAR cylindrical type suitable for existing APFC panel complete incl removal of old unsv capacitor complete all as specified and as directed.
All as per item No 66 above but 2 KVAR
All as per item No 66 above but 3 KVAR
All as per item No 66 above but 5 KVAR
M&L for PCC (1:3:6) type C2 with 40 mm graded stone aggregate for base / foundation for feeder pillar or pole including form work complete all as specified and as directed.
M&L for fault finding in U/G cable using fault locating machine on requirement for LT/HT cables of any type/size complete all as specified and as directed.
S&F cable route indicator, cast iron 10 cm dia with 25x25x4 mm angle iron 0.8 m along the LT/HT cable in trench including painting and grouting in ground in PCC 1:2:4 type B1 using 20 mm graded stone aggregate complete all as specified and as directed.
M&L for shifting of LT Panel from one location (within the electrical zone) to another location including making all electrical connections as well as PCC foundation completely as specified and as directed. Note:-Excavation & related earth work shall be inclusive of quoted rates.
LAKSHMI ASSOCIATES
M/s Prakash Enterprises
M/S Anil Enterprises
M/S TRADE LINKERS
Nvimal Engineers and Contractor
S.R.Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .