| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC JAISALMER | JAISALMER | RAJASTHAN | 342310 | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.6 L+₹52,176 (1.58%)Rejected-Finance 1286 TOTA RAM KI DHANI JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.5 L+₹5.4 L (16.4%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹38.6 L+₹5.6 L (16.9%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹41.8 L+₹8.8 L (26.6%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
26 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPL REPAIRS TO CERTAIN GUARD POSTS AND SEWAGE LINE IN OTM ACCN AT MIL STN JAISALMER
2023_MES_599106_1
8303/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹93,000
Yes
1 Sept 2023
29 May 2023
3 Jul 2023
29 May 2023
26 Jun 2023
12 Jun 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick (below or above ground level) & removing rubbish out side MD landcomplete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and directed by the Engineer-in-Charge.
Returning filling in soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc complete all as specified and directed by the Engineer-in-Charge.
Returning filling in soil/disintegrated rock including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc complete all as specified and directed by the Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) but except stone complete all as specified & directed by Engineer-in-charge. Note :- Serviceable stone obtained from demolition shall be used.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-charge.
M&L Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25 to 35cm wide, hoisted and set, jointed and grouted in cement mortar (1:3) complete all as specified & directed by Engineer-in-charge.
M&L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in Padding complete all as specified & directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floors & finishing the surface even & fair without using extra cement all as specified & directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
S&F glazed ceramic coloured tiles of size 450mmx300mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick backing coat in CM (1:3) complete all as specified and directed by Engineer-in-charge.
Demolition of stone slab & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified & directed by Engineer-in-charge.
M&L Machine cut kota stone slab flooring 20- 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified & directed by Engineer-in-charge.
All as per item No. 23 above but as in skirting, steps etc in vertical surfaces with 10mm thick rendering as in backing coat in CM 1:3 complete all as specified & directed by Engineer-in-charge.
M&L sand stone slabs 5cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
M&L sand stone slabs 10cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing complete all as specified & directed by Engineer-in-Charge.
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
Providing, precast cement concrete (1:2:4) type B-1 (20 mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:6 complete with joints to match complete all as specified & directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L for rendering 5 mm thick plaster in cement mortar (1:3) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick, plaster in cement mortar (1:6) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and fair without using extra cement all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick on stone masonry surfaces in cement mortar (1:4) including water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge. (Note: Supply only water proofing compound shall be measured and paid seperately).
M&L for rendering 15 mm thick, plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and fair without using extra cement all as specified & directed by Engineer-in-charge.
Supply only integral water proofing compound in sealed pack (ISI marked) complete all as specified & directed by Engineer-in-charge.
M & L preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L preparation of new plastered surfaces of any description and applying two coats of oil emulsion distemper on wall over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered surfaces of ceiling incl Washing, rubbing down and stopping of distempered and painted and applying one coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered surfaces of wall incl Washing, rubbing down and stopping of distempered and painted and applying one coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered surfaces of wall incl Washing, rubbing down and stopping of distempered and painted and applying one coats of distemper oil emulsion complete all as specified & directed by Engineer-in-charge.
M&L for preparing old plastered surfaces incl Complete removal of existing treatment and applying Two coats of cement base paint incl priming coat on surfaces of walls, column, beam, chajjas etc complete all as specified & directed by Engineer-in-charge.
M&L preparation of old wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel (ordinary tint) (each coat) complete all as specified & directed by Engineer-in-charge.
M&L preparation of old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel (ordinary tint) (each coat) complete all as specified & directed by Engineer-in-charge.
Taking down Shutters of any description exc 2 sq. m each complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats (without taking down shutters from the frames) of any description exc 1.5 sq. m but n exc 4.0 sqm each complete all as specified & directed by Engineer-in-charge.
S & F factory made 35 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered article board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed by Engineer-in-charge.
S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by Engineer-in-charge.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium handle, cast type, anodiesed complete all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed by Engineer-in-charge.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MSD square tube etc complete all as specified & directed by Engineer-in-charge.
S&F factory made solid PVC moulded masonic door shutter 28 to 30 mm thick (style) with 2, 4, 6 raised panel design with 2 mm moulded PVC sheet on the front face and2 mm moulded PVC sheet on back face supply and fixing in the frame at site as per specification with particle board core complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous china squatting pan padastel type pattern “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC low level white flushing cistern syphonic action type 10 ltrs capacity incl flush pipe 32 mm dia incl PVC connection 450 mm long and complete all as specified & directed by Engineer-in-charge. (Make:-Cera Cat part No B1010102 or equivalent in Appx 'C' list of makes.
S&F in repairs 140 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drwn steel spring, fixed in floor complete all as specified & directed by Engineer-in-charge.
S&F in repair MS powder coated drapery rod 25mm dia decorative manner all as per sample complete all as specified & directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed by Engineer-in-charge.
M&L mild steel framed works such as angles, tees, channels, etc as in fenching posts large and small gates and grills, gratings and chainlink fenching etc, including hanging gates in pillar with proper pintle hinges, stops, hand made sliding bolts ,etc complete all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each panes and including hacking out old broken glass of any thickness size, quality or description from metal frames complete all as specified & directed by Engineer-in-charge. Note :- To be fixed at any floor level not more than triple storey.
S&F steel water tubing 15mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F in repair, 15 mm bore, bib tap, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F in repair, 15mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified & directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls and including taking down existing pipe of any description complete all as specified and directed by Engineer-in-charge.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and including taking down existing pipe of any description complete all as specified and directed by Engineer-in-charge.
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and including taking down existing pipe of any description complete all as specified and directed by Engineer-in-charge.
M&L for in repair PVC (SWR) gully trap of 125/100mm setting and jointing with slovent cement complete all as specified & directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed by Engineer-in-charge.
S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by Engineer-in-charge.
S & F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by Engineer-in-charge.
M&L 100 mm size cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 complete all as specified & directed by Engineer-in-charge.
S&F 1000 litres capacity Three Layers White colour Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including taking down old existing PVC tank of any description complete all as specified and directed by Engineer-in-charge.
S&F ball valves for 15mm bore pipe, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified & directed by Engineer-in-charge. (minimum weight 142 gms)
S&F in repair vitreous china wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engineer-in-charge.
S&F Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm dia pillar taps cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-charge.
S&F in repair, tubular towel rail aluminium anodised, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC connection pipe for WHB, cistern, gysers etc of size 15 mm dia and 450 mm long fixed complete all as specified & directed by Engineer-in-charge.
M&L Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C-1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight complete all as specified & directed by Engineer-in-charge.
M&L for chequred cement concrete tiles fixed with grey cement & pigment of size 20cm X 20cm X 25mm thick set jointed and pointed in neat cement slurry laid over and including screed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6.complete all as specified & directed by Engineer-in-charge.
M & L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars including demolition and breaking up of existing pipes of any description complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M & L for 200mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars including demolition and breaking up of existing pipes of any description complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance complete all as specified & directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm dia pipe complete all as specified & directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm dia pipe complete all as specified & directed by Engineer-in-charge.
Cleaning of choked sewage line of 100 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified & directed by Engineer-in-charge.
Cleaning of choked sewage line of 150 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified & directed by Engineer-in-charge.
Cleaning of choked sewage line of 200 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified & directed by Engineer-in-charge.
Cleaning of choked sewage line of 300-600 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified & directed by Engineer-in-charge.
Cleaning of manholes not exceeding 1.5m deep by means of removing the silt, sludge, etc & bailing out foul water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required complete all as specified & directed by Engineer-in-charge.
Cleaning of manholes exceeding 1.5m but not exceeding 3m depth by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required complete all as specified & directed by Engineer-in-charge.
Cleaning of floor trap, gully trap in any size by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WC/EWC in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of urinal in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WHB in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Cleaning of septic tank, man holes and inspection chamber etc. by means of removing the silt, sludge, excreta etc. or other materials, manually or mechanically and depositing the same, where directed at a distance not exceeding 150m including excavation of pits of required size to accommodate the foul materials taken out from septic tank, manholes, soakage pits and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge. Note for item No. 1.00 :- (i) Depth of silt, sludge, excreta, etc shall only be measured and paid. (ii) Dewatering/pumping out of foul water shall be measured and paid separately.
Pumping out foul water from soakage wells / septic tank mechanically and removing sludge of capacity 100 users complete all as specified & directed by Engineer-in-charge.
M&L for rendering 10 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
Taking down carefully copper/ aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc removing materials for taking credit and making good disturbed surface of walls, floors etc complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-Charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-Charge.
Taking out carefully copper/GI earthing complete including GI pipe with Cu/GI strip and removing materials for taking credit and making good disturbed surface complete all as specified & directed by Engineer-in-Charge.
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One Ceiling /Exaust fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No 111.00 here-in-before but of size cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano, flush type, 6 amps, 230 volts, single pole, one way complete all as specified & directed by Engineer-in-charge.
S&F switch piano, flush type, 16 amps, 230 volts, single pole, one way complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
Supply and fixing 415V 10 KA 'C' curve MCB's TPN 40 to 100 Amps four pole and current carrying capacity in the DB with necessary connections and comissioning complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 6 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour including taking down existing u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length)
Supply and fixing LED building security light fitting 35 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S&F GI pipe bracket medium grade of 40 mm dia for building security light, clamps made of FI 40 mm x 6 mm Incl nuts, bolts & washers including two coats of synthetic enamel paint over a coat of zink chrome primer including taking down existing unserviceable bracket of any description complete all as specified and directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95, Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10%, Necessary mounting arrangements. The fixture shall be suitable for wall mounting /suspension mounting as per site requirement. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per Make :- Crompton CAT PART NO Shelter. CIS -305-40-57-SL-DP-NWH or equivalent in App 'C' list of makes.
S & F in repair of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
Supply, installation, testing and commissioning of LED flood light fitting 120 Watts made out of pressure die cast aluminium housing and IP-66 Protection with emmiter LED including making electri connection complete all as specified and directed by Engineer-in-charge. Make :- Crompton Cat fef LFLN-150-CDL/60M or equivalent in App 'C' list of makes.
Taking down ceiling fan/exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position as directed complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
Supply & fix heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
S&F fans ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-Charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 132.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, laying and testing LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core including cable gland, lugs & necessary jointing material and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 100 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor/trenches including cutting, threading and testing and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 80 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor/trenches including cutting, threading and testing and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 50 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor/trenches including cutting, threading and testing and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor/trenches including cutting, threading and testing and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F gun metel, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 20 mm bore with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge
S&F gun metel, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 20 mm bore with fittings and accessories. ISI marked and as per IS 14846 including taking down existing gate valve of any description complete all as specified & directed by Engineer-in-Charge
GEMRARAMCONTRACTOR
M/s Shri Inder Construction Company
M/S OM VISHNU ENGINEERING & CONSTRUCTION COMPANY
M/S MAYA CONSTRUCTION COMPANY
AMBEY MAA CONSTRUCTION COMPANY
BHAGWATI CONSTRUCTION
Leelashah Enterprises
Bhawani Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .