Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹5.2 L+₹85,950 (20.0%)Rejected-AOC 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹5.6 L+₹1.3 L (29.4%)Rejected-AOC B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹6.0 L+₹1.6 L (38.3%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹6.3 L+₹2.0 L (45.5%)Rejected-AOC B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
7 Feb 2022, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400 088
CONSULTANCY SERVICES FOR STRUCTURAL ANALYSIS AND NDT OF LOAD TEST PLATFORM AND LEAK TEST TANK AT SRU (W) OP FACILITY AT MANKHURD UNDER GE (NW) MANKHURD
2022_MES_502483_1
8131/E8
Open Tender
Civil Works
Item Rate
90 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUEMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹14,000
Yes
12 Feb 2022
19 Jan 2022
9 Feb 2022
19 Jan 2022
7 Feb 2022
25 Jan 2022
19 Jan 2022 - 24 Jan 2022
Amount
Load test platform
Visual Inspection & Photography : Performing a visual survey of the Deck Pad System & recording / mapping on drawing & extent of spalling of concrete, cracked concrete honeycombing, reinforcement corrosion, delaminated concrete etc, taking photographs to collect evidence of damage to structure. (SAC Code - 998346)
Site Testing Charges Concrete
UPV Test• : Ultra sonic Pulse Velocity Test (UPV Test) in accordance with IS : 13311 : Part 1 1992 by ponable ultrasonic non-destructive degital test equipment. Plaster chipping mandatory. lf chipping is not permitted by client, the same shall be noted. (SAC Code - 998346)
Rebound Hammer Test : Schmidt’s rebound hammer test for determining the concrete compressive test (Ref. IS: 1331 I - Part 2 )
Half Cell Potential* in accordance with ASThi C876 Half Cell Potential to assess the probability of corrosion of i-einforcement (SAC Code- 998346)
Carbonation* in accordance with BS 18P1-201-1986 clause 2.22 Carbonacion Test to measure extent of carbonation from the concrete surface. (SAC Code - 998346)
Profomeier Scan Test on CCC members to assesss covers,spacing ot bars including approximate diameter bar.
Core Test: Core cutting and compression test for RCC structure in accordance with IS:516 on RCC membeers.70mm core cutting in reinforcement concrete, core filling by specialized epoxy material/micro concrete with bond coat.
Structure to be analyzed for impact of all loads as per governing loads, Structural analysis & Design to be checked by E-tabs, Staad Pro, or any other relevent Software.
Preparing Detail Report :- • Visual inspection & Photographs • NDT Test Results • Analysis of NDT Data Results • Preparing of Drawings • Strucrural Analysis • Conclusion & Recommendations
Steel test tank
Performing a visual survey of the water tank and taking photographs etc . (SAC Code -998346)
Structural Analysis of existing water tank to check whether it is safe against hydrostatic and force due to immersion of submarine.
M/S. BECQUEREL INDUSTRIES PVT. LTD.
Geo Designs n Research Pvt Ltd
KBP CIVIL ENGINEERING SERVISES
Cortex Construction Solutions Pvt. Ltd.
A R ENGINEER
H R ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .