Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.6 L+₹1.2 L (4.67%)Rejected-Finance E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹29.0 L+₹2.7 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹38.6 L+₹12.2 L (46.4%)Rejected-Finance 7 345 C 1 AERO NAGAR KANGEYAMPALAYAM KADAMPADI SULUR COIMBATORE TAMIL NADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹62,300
Closing Date
19 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineers AF South , Bangalore
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
ADDITION/ ALTERATION/ IMPROVEMENT TO BUILDING NO P-18 ( AIRMEN MESS ) AT AFAC COIMBATORE
2021_MES_440365_1
84198/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) (AF) COIMBATORE
Ref NIT
7 documents required · 7 mandatory
₹500
AGE (I) (AF) Coimbatore
₹62,300
Yes
2 Sept 2021
4 May 2021
21 Jun 2021
5 May 2021
19 Jun 2021
7 Jun 2021
6 May 2021 - 15 May 2021
60 days
Amount
Demolition of brick work or stone /boulder masonary built in cement mortar including all quoins arches,pillars etc but excluding ashlar facings,dressed stone work and precast concrete articles complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, laid bedded and pointed in any mortar complete all as specified and directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thick (above or below the ground level) complete all as specified and directed.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&LBrick work with sub class 'B' bricks,straight or curved on plan exc 6m mean radius built in cm 1:6 with old size bricks complete all as specified and directed.
M&LBrick work with sub class 'B' bricks,straight or curved on plan exc 6m mean radius built in cm 1:4 with old size bricks complete all as specified and directed.
Demolition of reinforced cement concrete in any description and in any position complete all as specified and directed.
M & L Cement concrete 1:2:4 type B1 (20mm graded stone aggregate), 40mm thick for sub base for floor tile,kota stone complete all as specified.
M &L for pointing and jointed with grey cement slurry or white cement and with admixture of pigment to match the shade of kota stone of existing kota stone surface including grinding and polishing complete all as specified and directed.
M&L for Machine cut Kota stone 18 to 20mm thick as in floors, laid over 15mm thick rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing (granite finish) including cutting hole for inserting of studs, moulding and nosing as required etc complete as per specification and as directed by Engr-in-charge.
M&L for Granite (of any type) 16 to 18mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete in window cill, cooking platform over and including 5mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for Granite (of any type) 16 to 18mm thick machine cut, in skirting /dado laid over 10mm thick rendering in CM 1:4 cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete in window cill, complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:4 for laying floor finishes under floor and all as specified and directed.
M & L for glazed ceramic coloured tiles in vertical surface 350 x 250 x7mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1 : 4 on brick or concrete wall to receive tile etc all as specified and as directed.
Racking out joints / pointing as in cement mortar to squared rubble masonry coursed or uncoursed all as specified and directed.
M & L for keyed pointing in CM 1:4 for squared rubble masonry complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed.
Dismantling of mild steel work of any description not otherwise described complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified and directed.
M & L for 0.50mm thick Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws complete all as specified and directed.
Dismantling loose/disintegrated portion of RCC Chajjas, bands, shelves, beams and similar works incl provison of supports if reqd and dubbing with PCC (1 : 1.5 : 3) using 6 to 12 thick graded stone aggregate in any portion of 15mm to 50mm thick and finish including necessary scoffolding and temporary shuttering to edges with cement mortar 1:2 all as specified and as directed
M&L RCC type B-1, 1:2:4 using 20 mm graded stone aggregate as in Chajjas complete all as specified and directed.
M&L Form work to chullah hoods, Chajjas troughs and similar items including edges of rough finished flat surfaces of concrete complete all as specified and directed.
Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames) and all as specified and directed.
Taking down Chowkhat or frames exc 1.5 Sqm but not exceeding 4 Sqm each with shutters(Without taking off shutters from the frames) and all as specified and directed.
Taking down shutters of any description exceeding 1Sqm and not exceeding 2 Sqm each all as specified and directed.
S & F IInd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, and all as specified and directed.
S&F 30mm thick Flush shutters,solid core construction,with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 35mm thick second class Hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers ,for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats all as specified and directed.
S & F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory Made Solid PVC moulded door shutter, 28 to 30mm thick (stiles), 0f wood free EPS with 2, 4 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F 300 mm Aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts of extruded sections complete all as specified and directed.
S&F 150mm Aluminum anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 100mm Aluminum anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm extruded aluminium alloy handles, fabricated type, anodised all as specified and directed.
S&F 100mm extruded aluminium alloy handles, fabricated type, anodised all as specified and directed.
S & F Mild steel butt hinges 125 mm long medium weight of cold rolled all as specified and directed.
M&L PCC 1:2:4, type B0 (using 12.5 mm thk graded stone aggregate) as in bed plates, coping, levelling concrete, laid to slope etc all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise desribed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with staples or old serviceable fillets complete all as specified and directed.
S&F in repair stainless steel wire cloth of 0.36mm dia of wire and average width of aperture 1.40mm nominal with staples or old serviceable fillets complete all as specified and directed.
S & F PVC (SWR) pipes single sockted in any length with rubber ring joints laid/ fixed to walls 110 mm bore including taking down the old PVC pipe all as specified and directed.
S & F PVC (SWR) pipes single sockted in any length with rubber ring joints laid/ fixed to walls 75mm bore including taking down the old PVC pipe all as specified and directed.
PVC (SWR) bends any radius 110 mm bore with access door all as specified and directed.
PVC (SWR) bends any radius 75 mm bore with access door all as specified and directed.
Taking down steel tubing 15mm bore and connections all as all as specified and directed specified and directed.
Taking down steel tubing 20mm bore and connections all as specified and directed.
Taking down Cement plaster on bricks or stone walls etc including raking out joints, hacking for key , scrapping down with water etc,any description all as specified and directed.
M&L 75mm thick cement concrete 1:3:6, type C2 (40mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement all as specified and directed.
S&F 75mm extruded aluminium alloy butt hinges with galvanised mild steel hinge pin anodised, type E22 all as specified and directed.
S&F Steel ventlator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S/F sheet glass ordinary quality 3 mm thick, in squares n.exc. 0.50 Sqm in each pane with oil putty or with existing metal beadings including hacking out old broken glass from metal frame, punching or drilling out old galzing pins/spring clips complete all as specified and directed.
S&F 3mm thick Sheet glass ordinary quality and glazing with oil putty in square not exc 0.5sqm in each pane all as specified and directed.
S&F 3mm thick figured glass pin head type and glazing with oil putty in squares not exc 0.5 Sqm in each pane all as specified and directed.
S&F steel tubes medium grade galvanised with all fittings and fixtures 15mm bore fixed to walls all as specified and directed.
S&F steel tubes medium grade galvanised with all fittings and fixtures 20mm bore fixed to walls all as specified and directed.
M & L for 12mm thick plywood, grade BWR type BB , fixed with screws to timber frame work as in rack, shelf etc all as specified.
M& L 2nd claas hard wood plain fillets square/ rectangular or triangular in section, clean sawn secured with nails or brads sectional area exc 13 & not exc 25 sqcm all as specified and directed.
M&L Veneered decorative plywood , 6 mm thick grade 1 (with BWR resin) with decorative face veneers on both faces fixed with screws to timber frame work all as specified and directed.
M&L 12 mm thick Prelaminated particle board ,interior grade, preliminated one side with decorative choice lamination & other side balancing white lamination,fixed with screw to timber frame work complete all as specified and directed.
S & F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised width of flaps 30mm (when open) all as specified and directed.
S&F 40 mm dia cupboard knobs fixed with nut screw and washer of brass polished finished all as specified and directed.
M& L 2nd class hard wood plain fillets square,/ rectangular or triangular in section, clean sawn, secured with nails or brads sectional area exc 03 & not exc 06 sqcm all as specified and directed.
S & F Continuous (piano) hinges mild steel bright finish or electrogalvanised width of flaps 40mm (when open) all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue ,anodised with hard drawn steel spring fixed in floors 140 mm (overall length of cover plate) complete all as specified.
S&F of 0.56 mm thick aluminium sheeting alloy 31000H4 fixed with doors and fixed by nails etc all as specified and as directed.
S&F Anodised aluminium frame for sliding doors , Partition Walls, windows, ventilators with one or more rebates including joining clear for fixing etc.complete all as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars ,aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips rubber packing anodised aluminium snap beading, screws, anodised aluminum fittings such as peg stays 150 mm long( (1 No ) , hinges type B-21 100 mm long(2 Nos) suitable handle (01 No) etc complete all as specified and as directed
M&L Hard core of guage n. exc 63 mm, broken stone or boulders deposited spread and levelled in layers n.exc 15cm thick , watered and well rammed to a true surface complete all as specified and directed.
M&L 75mm thick PCC 1:4:8, type D2 ( 40 mm graded aggregate) as in sub base of paver block all as specified and directed.
M & L for machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS - 15658-2006of 80mm thickness , M-25 Grade with grey cement and pigment etc all as specified and as directed .
M&L for sand cushioning under floor or in foundation including watering and consolidation for laying of interlocking paver block all as specified and directed.
M & L for Precast cement concrete block masonry type C1, 1:3:6 (20mm aggregate ) solid blocks, n exc 10cm in width (with plain or interlocking joints as directed )and setting in cement mortar 1:4 as in edge of paver block etc all as specified and as directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as in ceiling and finishing the surface even and smooth without using extra cement all as specified and as directed.
M&L for Rendering 10mm thick on fair faces of brick work or stone wall surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer all as specified.
M & L for preparation of newly plastered surfaces and applying 3 coats of white wash on ceiling all as specified and as directed.
M & L for complete removal existing treatment of walls surfaces and applying two coats of cement based paint over a coat of primer all as specified and directed.
M & L Preparation of old plastered or unplastered surfaces of walls and applying one coat of oil bond distemper over one coat of primer all as specified and directed.
M & L for preparation of old plastered surfaces and applying one coat of white wash on ceiling all as specified and directed.
M & L for preparation of old plastered surfaces and applying two coats of white wash on wall all as specified and directed.
Preparing old wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamal paint all as specified and directed.
Preparation of old steel surfaces of any diecription over 10 cm width or girth and applying one coat of synthetic enamal paint all as specified and directed.
M & L RCC M-25 (20 mm graded aggregete) as in slabs supported on walls,beams and columns in floors, roofs and the like complete all as specified and directed.
M & L RCC M-25 (20 mm graded aggregete) as in Beams, cantilevers, lintels and the like complete all as specified and directed.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) for flat, fair finished surfaces of concrete complete all as specified.
M & L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs, fair finished flat surfaces complete all as specified.
M&L for Formwork to sides and soffits of floor or roof beams etc. also splays between floors and beams, etc. finished rough flat surfaces of concrete complete all as specified and directed.
M & L for TMT bars 10mm dia and over,cut to length ,bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia for securing with clips complete all as specified and directed.
M & L for TMT bars 8mm dia,cut to length ,bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia for securing with clips complete all as specified and directed.
M & L for TMT bars 5mm dia and over upto and incl 10mm,cut to length ,bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia for securing with clips as in stirrups, spacers and binders complete all as specified and directed.
Supply and fix 15mm bore bib taps, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix 15 mm bore stop valves fancy type chromium plated with cruch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
S&F 15mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or Cold with long screwed shanks and flynuts, screwed for iron pipe and fixed all as specified and directed.
S& F in repairs PVC waste pipe 32mm bore for ,WHB,and Sink all as specified and directed.
M&L UPVC pipe of pressure 10 kgf/cm2 suitable for water supply distribution incl all fittings,20 mm bore all as specified and directed.
M&L PVC (SWR) floor trap dia 75mm, plain with grating including jointing with solvent cement complete all as specified and directed.
M&L salt glazed stoneware gully traps, square or round mouthed, type 'P' of size 100x100mm all as specified and directed.
S&F 110mm dia PVC (SWR) vent cowl, complete all as specified.
Removing building material out side the campus including loading and unloading, etc to any distance at out side the M.D land all as specified.
Note : Location and permission of depositing the building materials/disposal out side the M.D. land shall rest with contractor at his own arrangement.
Surface excavation not exc 30 cm deep & averaging 15 cm deep and getting out in Hard / Dense Soil.
Excavation in trenches , n exc 1.5m wide and n.exc 1.5m in depth for foundation etc.or for shafts , wells , cesspits laying of cables/ poles etc as in soft/ loose soil complete all as specified.
Excavation in trenches , n exc 1.5m wide and n.exc 1.5m in depth for foundation etc.or for shafts , wells , cesspits laying of cables/ poles etc as in hard/ dense soil complete all as specified.
Excavation in trenches n exc 1.5m wide, exc 1.5m in deep and not exc 3.0m in deep for foundation etc.or for shafts , wells , cesspits laying of cables/ poles etc as in hard/ dense soil complete all as specified.
M & L for 100mm thick PCC 1:4:8, type D2 (40mm graded stone aggregate) as in sub base complete all as specified.
M & L for 50 mm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in floors finishing even and smooth without using extra cement complete all as specified.
M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified.
5 mm thick water proofing cement plaster in cm 1:3 mixed with approved water proofing liquid finished even and smooth over RCC roof slab complete all as specified.
M & L for rendering 20mm thick in CM 1:3 on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for applying of oil bound bituminous primer @ 0.20 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure on note No.6 of TD drawing No. AFB/TD/260/06 Sheet No.1/1 (R ) and applying a coat of blown grade @1.2 Kg per sqm hot bitumen 90/15 over and below the membrane finished with solar reflective bituminous aluminium paint/primer @ 0.1 Kg per sqm all as specified and as directed.
Supply only approved water proofing liquid all as specified and as directed. Note : WPC shall be measured & paid seperately.
M&L for providing post construction antitermite treatment along the external wall below concrete or masonry apron of bldg using chemical emulsion at the rate of 2.25 ltrs per linear metre including, drilling and plugging holes with white cement in apron complete all as specified and directed by Engr-in-Charge.
M&L for providing post construction antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart, including drilling and plugging 12mm dia holes with white cement mixed coloured pigment to match the existing floor complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soil complete all as specified and directed.
Removing excavated soil material to a distance not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point.
M&L Rotational moulded polyethyene water storage tanks of 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified,ball brass valves, high pressure, with polythene float (25mm dia) and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and as directed.
M& L for Pre-cast cement concrete 1:2:4 type B1 (20mm graded aggregate ) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers! shelves and similar articles etc with plain facss, and setting in cement mortar 1 :4 complete all as specified and as directed.
M & L for Framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 Grade E-165 all as specified and as directed.
M & L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces, plastered surfaces should be even and smooth with out using extra cement etc all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of primer all as specified.
S & F Unplasticised PVC pipe 25mm dia of pressure rating 10 kgf /cm2 fixed complete to walls, ceiling or in floors etc complete all as specified and as directed.
S & F ball brass vales 20mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or PVC pipe etc complete all as specified and as directed.
S&F of PPR Gate vales (brass insert) as per requirement of the site 25 mm outer dia of pipes all as specified and as directed.
S&F 25mm stop valves cast copper alloy, screwed down , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and as directed.
M & L for waste fittings,50mm brass,chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed in repairs all as specified and as directed.
M & L for flush pointing in CM 1:4 including raking out cement mortar joints/ pointing to brick tiles in floors,surface channels, roofs, etc including water proofing liquid all as directed.
M/L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe including packing to drain pipe and hunching against sides of pipe for 150mm dia pipes all as specified and as directed.
M/L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe including packing to drain pipe and hunching against sides of pipe for 200mm dia pipes all as specified and as directed.
M/L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe including packing to drain pipe and hunching against sides of pipe for 100mm dia pipes all as specified and as directed.
Cutting into existing man holes for connecting new drain , making good to pipe and rendering, cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm dia pipe all as specified and as directed.
M/L extra for forming fair finished to drain or channel 30cm inner girth in cement concreting using extra cement including forms, mould mitred/stopped end etc all as specified and as directed.
M/L for 100mm dia salt glazed stone ware drain pipes ISI Marked laid in trenches and jointed all as specified and as directed.
M/L for 150mm dia salt glazed stone ware drain pipes ISI Marked laid in trenches and jointed all as specified and as directed.
M/L for 200mm dia salt glazed stone ware drain pipes ISI Marked laid in trenches and jointed all as specified and as directed.
Cleaning of sewage line for removing the blockage by manually or technically for 150mm dia sewage line complete all as directed and as specified
Cleaning of sewage line for removing the blockage by manually or technically for 200mm dia sewage line complete all as directed and as specified
Cleaning of manhole of any size and depth upto 1.5m by removing the sludge and night soil including opening and removing the cover slab and keeping in position after cleaning etc complete all as specified and as directed.
Cleaning of covered drain including removal of sludge by opening the cover slab and placing the same in position properly complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces, plastered surfaces should be even and smooth with out using extra cement etc all as specified and as directed.
M & L for 15mm thick rendering in cement mortar 1:4 as in backing coat for fixing wall tiles all as specified and as directed.
M &L for Providing precast cement concrete 1:2:4 type B0, (12.50mm graded aggregate ) set in cm 1:4 , louvres and jallies, 25mm thick (measured solid), including all .mouldings but excluding frame all as specified and as directed.
M&L PCC 1:2:4, type B1 (using 20 mm thk graded stone aggregate) as in bed plates, coping, benching etc all as specified and directed.
Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
Taking down Ceiling fan sealing cable end, dismantling blades from fan, painting of Ceiling fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc, refixing and connecting up including provision of cable from celling rose/ connector to fan including keeping in safe custody for reuse at site and making good the disturbed surfaces complete all as specified and as directed.
Taking down exhaust fan, dismantling blades from fan, painting of exhaust fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc, refixing and connecting up including provision of cable from celling rose/ connector to fan including keeping in safe custody for reuse at site and making good the disturbed surfaces complete all as specified and as directed.
Disconnecting electric connection and taking down main switch/DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface all as specified and as directed.
M& L for making opening for fixing of exhaust fan of size 450 mm sweep complete and making good the disturbed surface to match with the existing surface complete all as specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed for one light point controlled by one, one way switch.
All as per item No 151 above but one ceiling/exhaust fan point controlled by one, one way switch.
All as per item No 151 above but one switch socket outlet point 5 Amps on independent board.
All as per item No 151 above but one switch socket outlet point 5 Amps on same board.
All as per item No.151 described here-in-before but with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Note for item No. 151 to 155 :- Cutting chases and making good in wall / floor will be Measured and paid seperately.
Supply & fix TARA-M/10W , LED tube light fitting 1x10W MS white powder coated decorative LED T8 batten with PC tube complete.
Make: C&S Cat No. LTDC01210WLED/WD or Havells Cat No. ENDURALINEARNEOBS10WLED830SPCWH or equivalent in Luker
Supply & fix LED Mirror light 10 watt, complete.
Make: Luker Cat No. LMR10 , Philips Cat No. 340341486 or equivalent in C&S, Havells.
Supply & fix surface mounting LED light fitting 4ft, 1x18 watt retrofit batten powder coated and including 1x18 watt 4 ft retrofit PC/glass tube complete with making connection by using twin core flexible twisted copper wire from ceiling rose to light fitting complete.
Make: Luker Cat No of batten- LLTB and Cat No. of tube - LTI818T , Havells Cat No. of BattenREGALBATTENT8UPTO1x22WDSBSWH and Havell Cat No. of tube CRYSTAL1213T8DSTL18WLED865GLASS or equivalent in C&S
Supply and fix LED Hanging tube light fitting 36 Watt complete with LED PC tubes with and including hanging aluminium string etc complete.
Make: Luker Cat No.LPL70501M, or Havells Cat No. CONSTA1144LP40WLED857SPCWH
Supply & fix exhaust fan 450 mm sweep metallic body heavy duty complete with louvrs, single phase 230 volts, 50 Hz, 1400 RPM complete.
Make : Crompton Model No. EXHD450-4-1, or equivelent in Usha, Philips, Havells model Turboforce450mm
S&F Triple pole and neutral enclosure, 240 volts with a three pin and earth plug and socket complete with one triple pole MCB 20 Amps.
M&L for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through in and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories surface/concealed in wall/Ceiling etc all as specified and as directed by engr - in- charge.
Note :- 2 runs of 6 sqmm, 1 run of 6 sqmm as earth cotinuity conductor and 1 run of PVC conduit shall be measured as one unit length.
Supply and fix sheet metal enclosure double door with distribution board vertical (DB) VTPN, 415 volts, having IP:43 protection, isolated neutral bar, insulated busbar assembly, door earthing arrangement, mechanical impact strength IK08, 04 way double door suitable for fixing 4 pole MCCB upto 125 Amps, frame F1 as incommer and MCBs SP as out going complete, fixed on wall and connecting with all electric connections/circuit complete all as directed by Engineer in charge. Make: Indoasian Cat No. 811870 or Havells Cat No. DHDLVDRWGOF004, or eqivalent in Standard
Supply and fix sheet metal enclosure with distribution board (DB) TPN, 415 volts, having IP:43 protection, isolated neutral bar, insulated busbar assembly, door earthing arrangement, mechanical impact strength IK08, 06 way compact double door suitable for fixing MCBs TPN as in commer and out going complete.
Supply and fix MCB DB, SPN, 8 ways, Isolated neutral bar with double door IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete.
Supply and fix 4 pole MCCB 100 A frame 1, 50 Hz, 415 V with rupturng capacity 25 kA complete all as specified and directed.
Make: Indoasian Cat No. 830052 or equivalent in Havells, Standard
Supply and fix MCB TPN 63 Amps, 240Volts, 10 KA, "C" Curve complete.
Make: Indoasian, Cat No. 811220 or Havells Cat No. DHMGCTNF063, or equivalent in Standard.
Supply and fix MCB TP 16 Amps, 240Volts, 10 KA, "C" Curve complete.
Make: Indoasian, Cat No. 811192 or Havells Cat No. DHMGCTPF006-032, or equivalent inStandard.
Supply and fix MCB SPN 40 Amps, 240Volts, 10 KA, "C" Curve complete.
Make: Indoasian Cat No. 811152 or Havells Cat No. DHMGCSNF040, or equivelent inStandard
Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, "C" Curve complete.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
S&F Modular fan regulator step type 120 W, 2 module complete all as specified and as directed.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
M&L for concealed Sub main wiring by making recess in wall/surface complete with 4 runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 2 run of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 40 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc for incommer of VTPN DB all as specified and as directed by engr - in- charge.
Note :- 4 runs of 10 sqmm, 2 run of 10 sqmm as earth cotinuity conductor and 1 run of PVC conduit shall be measured as one unit length.
M&L for concealed Sub main wiring by making recess in wall/surface complete with 4 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 2 run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc for three phase sockets all as specified and as directed by engr - in- charge.
Note :- 4 runs of 4 sqmm, 2 run of 4 sqmm as earth cotinuity conductor and 1 run of PVC conduit shall be measured as one unit length.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board/ feedar pillar and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:2:4 type B-1 & RCC cover and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth
M/L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, multi stranded, 1100 volts grade, cross-sectional area 10 Sqmm, 4 core.
Supply and laid well burnt bricks sub-class 'B' designation 75 for cable protection, brick shall be laid dry flat as width of brick eqals to the length of cable and the gap between adjacent brick shall not exceeded 10 mm, complete all as specified and as directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-31, 09 Metres long complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 using 40 mm gradded stone aggregate in foundations, filling mass concrete for errection of steel tubular pole complete all as specified and directed.
M&L for GI pipe 40 mm dia light grade with all fittings for cable protection laid under road/path/hard standing or fixed with wall/pole etc complete all as specified and directed.
Supply and fix LED Street light 90 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device complete mounted on GI bracket 40 mm dia light grade, bent to shape, fixing with street light pole including necessary fixing arrangement such as nuts, bolts, washers, clamps etc and making connection complete all as specified and directed.
Make: Havells Cat No. ENDURAPEARLPLUSSL90WLED757SASYTOPCASTHO, Luker Cat No. LST-90 or equivalent in Crompton
S&F Cable junction box IP66 halogen free and weather proof for out door installation made of thermoplastic material of size 167mm x125mm x 82 mm, suitable for upto 35 sqmm cable entry & cable out opening , fitted with and 01 Nos MCB SP, 6 for control of street light and 4 pole conector 32 amps -1 No complete internally pre-wired fitted with terminals,connectors etc and including neccessary fixing arrangement such as nuts, bolts, washers, clamps etc & making connection complete.
Make: Hensel, Cat No. KF5105 or equivelent in Sintex, Array
M&L for cutting of existing bituminous road/path/hard standing suitable for laying cable protection pipe 40 mm dia under the road/path/hard satnding at a depth not less than 60 CM below the normal ground level, Returning filling soil and making good the disturbed surface of road/path/hardstanding by using cement concrete mortar 1:3:6 type C2, using 40 mm graded stone aggregate 0.30 mtr wide and 0.30 mtr thick complete all as specified and directed.
M&L for sub main wiring Flexible copper cable multistrand 2x 1.5 sqmm and 1 x 1.5 sq mm as earth continuity conductor FR PVC insulated, drawn through in and including non mettalic PVC rigid conduit incl fixing accessories such as clamps, nut/bolts washers etc fixed with wall surface or fixed with pole complete and making connection complete all as specified and directed.
Supply and fix time switches 250 volts single phase of 20 amp rating with contactor & one MCB SPN 20 Aamps plus one MCB SP 16 Aamp fitted inside the steel enclosure with and including all fixing accessories complete all as specified and directed.
Make of timer Havells Cat No.DHTED15016 or equivalent in Iindoasian, Standard, L&T.
M&L for PCC 1:3:6, type C1 (using 20mm graded stone aggregate) in coping for poles including form work complete all as specified.
SEMBA ELECTRICALS
M/s Shana Constructions
p.chinnasamy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .