Loading…
Loading…
Tender Value
₹61.5 L
EMD Value
₹1.2 L
Closing Date
5 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
POWER/BCT
22 conditions · 5 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure - VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. (Page-14, Para 10.2, Part-I of GCC April 2022). Attached Performa as per Annexure VIB - in Tender Document).
Electrical Contractor License: The tendering firm must have valid Electrical Contractor's License issued by any State Government in their own name or in the name of the firm, as per IE Rule 1956 clause No. 45 or as amended from time to time. A copy of the license shall be uploaded along with the tender offer failing which the offer shall be summarily rejected. The license must be valid as on the date of opening of the tender. If the license has been expired as on the date of opening of tender, the license renewal documents must be uploaded along with the copy of the old license. The Contractor shall possess valid License throughout the currency of the contract. The contractor shall ensure timely renewal of the license.
Similar Nature Work - "Wiring/Re-wiring in buildings with associated electrical works like control gear and protection arrangements in residential buildings or service buildings or railway stations /yards or colony/highway lightings. OR Lighting arrangement in buildings, circulating area, yard, street etc. with associated electrical woks. OR Wiring/Rewiring, Lighting arrangement in buildings with associated electrical works."
26 conditions · 7 needing a document upload
1) The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. 2) The Bid Security shall be deposited either in cash through e-payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. (3) In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days before closing date for submission of bids(ACS-2 Dated 13.12.2022) iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non-submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder. (As per Clause 5, Page -4,5,6 Part I GCC April 2022 with ACS-2 Dated 13.12.2022)
Subject to exemptions provided under para 5(1) (a) of Part-1 (ITT) of GCC April 2022, the tender must be accompanied by a Bid Security as mentioned in tender documents, failing which the tender shall be summarily rejected. (Clause 6 (a) Annex -I, Page-11, Part-I of GCC April 2022)
Note: i) Any firm recognized by Department of Industrial Policy and Promotion (DIPP as 'Startups' shall be exempted from payment of Bid Security subject to submission of Registration Certificate issued by appropriate authority. ii) Labour Cooperative Societies shall submit only 50% of Bid Security shall also additionally submit Registration Certificate. (As per Clause 5 , Page-5, Part-I of GCC April 2022)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer Credentials: Documents testifying tenderer previous experience and financial status should be produced along with the tender. (Clause 11, Page-16-17, Part-I of GCC April 2022)
(i) Certificates and testimonials regarding contracting experience for the type of job for which tender is invited with list of works carried out in the past.
(ii) Audited Balance Sheet duly certified by the Chartered Accountant regarding contractual payments received in the past.
(iii) The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
(iv) A copy of certificate stating that they are not liable to be disqualified and all their statements / documents submitted along with bid are true and factual. Standard format of the certificate to be submitted by the bidder is enclosed as Annexure-V. Non submission of a copy of certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested / digitally signed by which they/he are/is qualifying the Qualifying Criteria mentioned in the Tender Document.
(v) The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway there under.
(vi) (a) In case of any information submitted by tenderer is found to be false, forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Bid Security besides banning of business for a period of upto two years. (b) In case of any information submitted by tenderer is found to be false, forged or incorrect after the award of contract, the contract shall be terminated. Bid Security, Performance Guarantee and Security Deposit available with the railway shall be forfeited. In addition, other dues of the contractor, if any, under this contract shall be forfeited and agency shall be banned for doing business for a period of upto two years.
Non-compliance with any of the conditions set forth therein above is liable to result in the tender being rejected.
This tender complies with Public Procurement Policy (Make in India) Order, 2017 - Revision dated 16/09/2020, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2020/RS(G)/779/2/Pt.1 dated 25/09/2020 and amendments / revisions thereof." The full details of the order can be seen at http://dipp.nic.in/whats-new/publicprocurement- preference- make-india-order- 2017. (Authority Railway Boards L. No. 2020/RS(G)/779/2/Pt.1 dated 25-09- 2020)
Contractor is to abide by the provisions of various labour laws in terms of above clause 54, 55, 55-A and 55-B of the Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website ''www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/ company etc. and upload requisite details of labour and their payment in this portal. These details shall be available in public domain. (Page- 86-89, Part-II of GCC-April 2022)
Mumbai Central - Electrical (Power) work in connection with improvement and furnishing of Officers Rest House at Near Rail Nikunj & Mumbai Central Main station and ORH Parichar Sadan.
EL-81-7-927-WA-42R~WR
EL-81-7-927-WA-42R
Open
Works - General
6 Months
Mumbai, Maharashtra
₹0
₹1.2 L
5 Feb 2026
13 Jan 2026
22 Jan 2026
97 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 61,46,703 | ||
| — | 400.00 | — | — | ||
| Supply of material and providing light/fan point concealed wiring, with single core multi-strand copper wire, PVC insulated unsheathed, LSHF / ZHFR, of size 1.5 sq.mm. for phase, neutral & earth wire and modular switches, complete with all accessories, junction box, ceiling rose etc, as per specifications in Annexure I. | — | — | — | 2,10,400 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing & commissioning of call bell, and supply of material and providing concealed wiring of call bell point, with single core multi-strand copper wire, PVC insulated unsheathed, LSHF / ZHFR, of size 1.5 sq.mm. for phase, neutral & earth wire, and modular switches, complete with all accessories, junction box, ceiling rose etc., as per specifications in Annexure II. | — | — | — | 22,800 | |
| — | 2750.00 | — | — | ||
| Supply of material and providing main/ submain concealed wiring with single core multi-strand copper wires, PVC insulated unsheathed, LSHF / ZHFR, of size 2.5 sq.mm., with set of 3 wires for phase, neutral & earth wire, as per specifications in Annexure III. | — | — | — | 3,05,250 | |
| — | 4039.00 | — | — | ||
| Supply of material and providing main/ submain concealed wiring with single core multi-strand copper wires, PVC insulated unsheathed, LSHF / ZHFR, of size 4.0 sq.mm., with set of 3 wires for phase, neutral & earth wire, as per specifications in Annexure III. | — | — | — | 6,26,045 | |
| — | 300.00 | — | — | ||
| Supply, fixing, testing & commissioning of modular socket 3 pin of 10A capacity with 10A one way modular switch, as per specifications in Annexure IV. | — | — | — | 50,700 | |
| — | 150.00 | — | — | ||
| Supply, fixing, testing & commissioning of modular power socket 3 pin twin heavy duty of 10/20 A capacity with 20A one way modular switch having neon indicator, as per specifications in Annexure V. | — | — | — | 46,650 | |
| — | 50.00 | — | — | ||
| Supply, fixing & commissioning of weather proof modular power socket 3 pin twin heavy duty of 20A capacity with 20A SP modular MCB in enclosure made of non metallic polycarbonate thermoplastic material, IP 65, as per specifications in Annexure VI. | — | — | — | 75,000 | |
| — | 25.00 | — | — | ||
| Supply, fixing & commissioning of single phase 20A, 230V, DP industrial type socket outlet, with phase, neutral & earth, metal enclosed plug top alongwith 20A DP MCB in SS enclosure, as per specifications in Annexure VII. | — | — | — | 62,225 | |
| — | 120.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of four module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure VIII. | — | — | — | 16,920 | |
| — | 100.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of six module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure VIII. | — | — | — | 17,800 | |
| — | 100.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of twelve module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure VIII. | — | — | — | 25,800 | |
| — | 15.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of sixteen module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure VIII. | — | — | — | 4,275 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of MCB DB single phase with RCCB in m.s. enclosure, I/C-DP MCB of 40A - 1No. & DP RCCB of 40A - 1No., O/G: SP MCB of 6A-32A - 8Nos., as per specifications in Annexure IX. | — | — | — | 1,19,150 | |
| — | 6.00 | — | — | ||
| Supply, fixing & commissioning of MCB DB three phase, I/C: MCB TPN 63A - 01 No & O/G: 1) MCB SP 10A- 04 Nos. 2) MCB SP 20A - 04 Nos. 3) MCB SP 32A - 04 Nos., enclosure made of non metallic polycarbonate thermoplastic material, IP 65 weatherproof, as per specifications in Annexure X. | — | — | — | 65,934 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of Geyser, storage type of 10 ltrs capacity, as per specifications in Annexure XI. | — | — | — | 1,31,225 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing & commissioning of decorative type super energy efficient BEE 5 star rated BLDC ceiling fan 1200mm (48") sweep with down rod, and standard accessories, fan & regulator shall be compatible to work with various makes & models, fan as per sample approved, & as per specifications in Annexure XII. (Minimum Warrantee - 2 years) | — | — | — | 2,20,700 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of exhuast fan 8"/9" of plastic blade, as per specification given in Annexure XIII. | — | — | — | 31,170 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing & commissioning of super energy efficient BLDC motor industrial exhaust fan of size 300mm (12") sweep and standard accessories, as per specifications in Annexure XIV. (Minimum Warrantee - 2 years) | — | — | — | 79,275 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of wall bracket fan of size 16"/400mm sweep, 1350 rpm and BLDC motor, as per specifications in Annexure XV. (Minimum Warrantee - 2 years) | — | — | — | 1,07,200 | |
| — | 20.00 | — | — | ||
| Supply and providing Pedestal fan size 16"/400mm sweep, BLDC motor, with regulator as per specifications in Annexure XVI. (Minimum Warrantee - 2 years) | — | — | — | 91,220 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED for use atop mirrors, with small-to- mid-sized vanity cabinets, or over wash basins. Effective heat dissipation with extruded aluminum heat sink, Robust driver with wide voltage range 100-240 volts and inbuilt protection, protected from dust and insects, Waterproof moisture anti-fog anti-corrosion anti-rust, complete with cover/ other accessories etc. Luminous efficacy 90 Lumen/ Watt. Metal frame in chrome finish with glass/ acrylic diffuser. Colour temperature: between 2700K - 3500 Kelvin (Warm White). Fitting shall be as per sample approved, and shall be fixed with proper workmanship and wiring. | — | — | — | 25,700 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 20W maximum, 4 ft long, System efficacy greater than or equal to 110 lm/W, Luminaires must be capable of delivering minimum 2000 lumens, luminaires complete with all accessories and other specifications as per Annexure XVII. (Minimum Warrantee - 5 years) | — | — | — | 11,300 | |
| — | 280.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 24W minimum, 8"x 8" size, surface/ recess mounting type, System efficacy greater than or equal to 100 lm/W, Luminaires must be capable of delivering minimum 2400 lumens, luminaires complete with all accessories and other specifications as per Annexure XVII. (Minimum Warrantee - 5 years) | — | — | — | 3,86,960 | |
| — | 90.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED 20W-30W, ceiling /wall bracket /wall mounting decorative light fitting, Effective heat dissipation with extruded aluminum heat sink, Robust driver with wide voltage range 100-240 volts and inbuilt protection, protected from dust and insects, complete with cover/ other accessories etc. Wattage may vary as per site requirement. Luminous efficacy 70 Lumen/ Watt min. Fitting shall be as per sample approved, and shall be fixed with proper workmanship and wiring. | — | — | — | 6,87,150 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED reading light fitting of 3W (minimum), robust driver with wide voltage range 100-240 volts and inbuilt protection, protected from dust and insects, complete with cover/ accessories, control switch on the base etc. Fitting shall be as per sample approved, and fixed with proper workmanship and wiring. | — | — | — | 25,650 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED night light/ foot light fitting of 4W/ modular type of 3 module, robust driver with wide voltage range 100-240 volts and inbuilt protection, protected from dust and insects, complete with cover/ accessories etc., as per model no.673036 / 675597 of Legrand or similar or as per sample approved. Fitting shall be fixed with proper workmanship and wiring. | — | — | — | 10,650 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 60W maximum, whether proof having IP 65/66 protection, System efficacy greater than or equal to 120 lm/W, Luminaires must be capable of delivering minimum 7000 lumens, luminaries complete with all accessories and other specifications as per Annexure XVII. (Minimum Warrantee - 5 years) | — | — | — | 61,890 | |
| — | 10.00 | — | — | ||
| Provision of new fire extinguishers, 6 KG DCP type, as per specifications in Annexure XVIII. | — | — | — | 15,880 | |
| — | 10.00 | — | — | ||
| Provision of new fire extinguishers, 4.5 KG CO2 type, as per specifications in Annexure XIX. | — | — | — | 30,490 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of 125A, 4 pole electronic / microprocessor based MCCB, with inbuilt earth fault protection along with earth leakage protection having shunt coil, earth leakage relay 30mA -30A CBCT etc., in sheet steel enclosure, as per specifications in Annexure XX. | — | — | — | 1,04,364 | |
| — | 500.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 50 sq.mm.x 4 core, as per specifications in Annexure XXI. | — | — | — | 1,58,500 | |
| — | 300.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded copper conductor cable of size 10 sq.mm.x 4 core, as per specifications in Annexure XXI. | — | — | — | 1,76,700 | |
| — | 32.00 | — | — | ||
| Supply, fixing, testing & commissioning of aluminium lugs of size 50 sq.mm. for cable termination, as per specifications in Annexure XXII. | — | — | — | 512 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing & commissioning of heavy duty copper lugs of size 10 sq.mm. for cable termination, as per specifications in Annexure XXIII. | — | — | — | 520 | |
| — | 300.00 | — | — | ||
| Supply of material & saddling to the cables with GI saddles, as per specifications in Annexure XXIV. | — | — | — | 13,800 | |
| — | 500.00 | — | — | ||
| Supply of material, fabrication of clamps of size minimum 25x3 mm & GI screw of size minimum 2 inch, and clamping of cables as per specifications in Annexure XXV. | — | — | — | 42,000 | |
| — | 15.00 | — | — | ||
| Supply, fixing & commissioning of cable looping junction box, weatherproof for single phase, made of glass fiber reinforced polyester GRP moulding composite material, of minimum size 200mm x 140mm x 95mm (inside dimensions) with Kitkat fuse, as per specifications in Annexure XXVI. | — | — | — | 6,930 | |
| — | 4.00 | — | — | ||
| Supply of material & installation of maintenance free earth electrode of length 3 meter, including earth enhancement material for earthing for each electrode & other accessories as per Drg. No. SDO/ RDSO/ E&B/001 and RDSO Spec No. RDSO/SPN/197 /2008, as per Annexure XXVII. | — | — | — | 44,548 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing & commissioning of G.I. strip 25mm x 6mm for earthing, including cutting, bending, welding, excavation etc., as per specifications in Annexure XXVIII. | — | — | — | 4,000 | |
| — | 100.00 | — | — | ||
| Supply & fixing of PVC casing & capping of size 50mm x 100mm with all accessories for covering of cables/ wires etc., as per specifications in Annexure XXIX. | — | — | — | 76,200 | |
| — | 30.00 | — | — | ||
| Supply of energy efficient inverter type split air conditioner unit of capacity 1.5 TR, having min. ISEER 5.0, along with copper tubing of on an average 3 mtr in length, as per specifications in Annexure XXX. | — | — | — | 15,42,990 | |
| — | 300.00 | — | — | ||
| Supply and fixing of refrigerant copper tubing with insulation of required size, copper pipe dia 5/8" or 3/8" or 1/2" as per site requirement, complete with hardware fittings, as per specifications in Annexure XXXI. | — | — | — | 1,60,500 | |
| — | 300.00 | — | — | ||
| Supply and fixing of refrigerant copper tubing with insulation of required size, copper pipe dia 1/4", complete with hardware fittings as per specifications in Annexure XXXI. | — | — | — | 87,600 | |
| — | 30.00 | — | — | ||
| Supply and fixing of bracket type ready made M.S. stand for outdoor units of split Air conditioners, as per specifications in Annexure XXXII. | — | — | — | 47,940 | |
| — | 350.00 | — | — | ||
| Supply, fixing, testing and commissioning of PVC insulated & sheathed copper cable flexible multistrand of size 2.5mm², 4 core, as per specifications in Annexure XXXIII. | — | — | — | 53,200 | |
| — | 175.00 | — | — | ||
| Supply and fixing of plumber grade CPVC pipe line of nominal bore size 25 mm / 40 mm, as per site requirement, with all accessories, to drain out the condensate water - as per Annexure XXXIV. | — | — | — | 16,100 | |
| — | 25.00 | — | — | ||
| Supply and fixing of flexible pipe to drain water. The drain pan shall be connected to rigid PVC pipe by braided PVC flexible pipe with appropriate adapters. | — | — | — | 1,000 | |
| — | 30.00 | — | — | ||
| Installation, testing & commissioning of split AC units of capacity 1.0TR/1.5 TR/2TR at the nominated site, as per specifications in Annexure XXXV. | — | — | — | 43,890 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-April-2022.pdf
ATTACHMENT
GCCCorrectionSlipNo1ofACS-14-07-2022.pdf
ATTACHMENT
GCCApril2022CorrectionslipNo_2RBDtd13122022.pdf
ATTACHMENT
IRSGCC-2022-AdvanceCorrectionSlipNo.3.pdf
ATTACHMENT
GCCApril2022ACS4.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo_5.pdf
ATTACHMENT
AnnexureVIBAnnualContractualTurnoverGCC2022.pdf
ATTACHMENT
AnnexureVclarificationforonlinesubmissiondated14.05.2024.pdf
ATTACHMENT
NoRelativeFormatEmployeeofWesternRailway-Annexure-II.pdf
ATTACHMENT
NORETIREDRAILWAYEMPLOYEEGCC2022-Annexure-III.pdf
ATTACHMENT
BankGuaranteeNewFormat.pdf
ATTACHMENT
EL-81-7-927-WA-42R2025-2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .