Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | ₹30.9 L Quoted ₹32.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹32.9 L+₹46,041.45 (1.42%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹32.9 L+₹46,041.45 (1.42%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹33.9 L+₹1.5 L (4.69%)Rejected-Finance | ₹33.9 L+₹1.5 L (4.69%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹34.6 L+₹2.2 L (6.64%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | ₹34.6 L+₹2.2 L (6.64%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹35.6 L+₹3.2 L (9.83%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | ₹35.6 L+₹3.2 L (9.83%) | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
22 May 2021, 6:00 pmClosed
GE I KANPUR
GE I KANPUR Cariappa Road Kanpur 208004
REPAIR REPLACEMENT OF LT PANEL BUS BAR LIGHTNING CONDUCTOR AND VARIOUS ITEMS IN CANTT AND INSIDE DGQA UNDER AOR OF AGE EM UNDER GE I KANPUR
2021_MES_438213_2
GE(I)/KAN/T-12 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kanpur Cantt
Class D category b i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹99,800
Yes
9 Jun 2021
24 Apr 2021
24 May 2021
24 Apr 2021
22 May 2021
10 May 2021
Amount
EnM Schedule
Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for under ground cable / pole foundation and getting out including forming bottom surface to required level or slop, complete all as specified and directed .
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft / loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
Supply & spreading local sand obtained from ganga river in trenches for cable cushioning 8 cm under and 15 cm over the cable complete all as specified and directed. Note: Punned thickness shall be measured.
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed..
Laying only bricks any size/type obtained from srl item no 02 above laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed..
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as speified and directed. Make: Mehtab tiles Indore/Hind Mosaic Tiles Upleta. Note: Purchase voucher and manufacturer test certificate shall be submitted by contractor while claiming payment.
Demolition of cement concrete (un reinforced) in ground floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed..
M&L for cement concrete ( 1:2:4) type B-1 using 20mm graded stone aggregate for as in floor/hardstanding surface finished even and smooth without using extra cement to match with the existing surface complete all as specified and directed..
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection pipe upto 80 mm bore complete all as specified and as directed by Engineer in Charge. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Taking out carefully unserviceable LT UG cable of size 6 Sqmm to 35 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Taking out carefully unserviceable LT UG cable of size 50 Sqmm to 240 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Taking out carefully unserviceable HT UG cable of size 70 Sqmm to 185 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Disconnecting and taking out existing unserviceable LT Cables of sizes 6 sqmm to 25 sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Supply and laying to wall or poles or fixing or passing through pipe, of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core Including making good all distributed wall / flooring/tilling surfaces to match with existing specification complete all as specified and directed. Make: Gloster/Havells/ Polycab/ Grandlay/Finolex Note : 1.Cable laying and jointing are required to be carried out in short / long stretches as per site requirement 2.Necessary excavation and earth work , sand cusioning, cable cover will be measured and paid separately.
All as per srl item No 16 above but cable of size 10 Sqmm 2 core.
All as per srl item No 16 above but cable of size 6 Sqmm 2 core.
All as per srl item No 16 above but cable of size 25 Sqmm 2 core.
Disconnecting and taking out existing unserviceable LT Cables of sizes 25 sqmm to 95 sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out existing unserviceable LT Cables of sizes 120 sqmm to 400 sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Supply laying , jointing, testing and commissioning of XLPE insulated, PVC sheathed, strip armoured heavy duty electric cable with aluminium conductor (stranded) working voltage upto 1100 volt confirming to IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of aluminium lugs duly crimped with die press crimping device and cable gland of size 25 Sqmm 3.5 core complete all as specified and directed : Make: Gloster/Havells/ Polycab/ Grandlay/Finolex Note : 1.Cable laying and jointing are required to be carried out in short / long stretches as per site requirement 2.Necessary excavation and earth work , sand cusioning, cable cover will be measured and paid separately.
All as per srl item No.22 but cable of size 35 Sqmm 3.5 core.
All as per srl item No.22 but cable of size 70 Sqmm 3.5 core.
All as per srl item No.22 but cable of size 95 Sqmm 3.5 core.
All as per srl item No.22 but cable of size 120 Sqmm 3.5 core.
All as per srl item No.22 but cable of size 150 Sqmm 3.5 core.
All as per srl item No.22 but cable of size 185 Sqmm 3.5 core.
All as per srl item No.22 but cable of size 240 Sqmm 3.5 core.
S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core complete all as specified and directed. Make : Denson/ M seal/ 3 M.
All as per item No 30 but for 6 to 25 Sqmm size 2 core.
All as per item No 30 but for 50 to 95 Sqmm size.
All as per item No 30 but for 120 to 185 Sqmm size.
All as per item No 30 but for 225 to 300 Sqmm size.
S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core complete all as specified and directed.Make : Denson/M seal/ 3 M.
All as per item No 35 but for 25 to 50 Sqmm size.
All as per item No 35 but for 70 to 150 Sqmm size.
All as per item No 35 but for 185 to 240 Sqmm size.
Disconnecting electrically, dismantling from foundation with due care and setting aside old unserviceable LT panel box any type any size with all accessories.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 600 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 400 Amps 4 pole 35/36 KA, two Nos 200 Amps 4 pole 35/36 KA, two Nos 100 Amps 25 KA, one Nos 63 Amps 25 KA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at single living accn front of KV School as required at site complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 KA, one Nos 160 Amps 4 pole 25 KA two Nos 100 Amps 4 pole 25 KA, two Nos 63 Amps 25 KA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site at COD Estate near Gurudwara complete all as required at site or directed.Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-06, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 KA, two No 100 Amps 4 pole 25 KA. two Nos 63 Amps 25 KA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site at near main pump house Cantt complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 250 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 160 Amps 4 pole 35/36 KA, one No 100 Amps 4 pole 25 KA, two No 63 Amps 25 KA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site at near T 2/1 Old MH complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 600 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-10, suitable for and including one incoming MCCB 400 Amps 4 pole 35/36 KA one Nos 250 Amps 4 pole 35/36 KA, three Nos 100 Amps 25 KA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at HRDC Qtrs Cantt as required at site complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 ka, two Nos 100 Amps 4 pole 25 ka, two Nos 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at COD Estate gate near P-9 block as required at site complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-06, suitable for and including one incoming MCCB 200 Amps 4 pole 35/36 ka, one No 100 Amps 4 pole 25 ka, three Nos 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site at COD Inside near guard post-2 and 18 complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 250 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 160 Amps 4 pole 35/36 ka, one No 100 Amps 4 pole 25 ka, two No 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at near VRG pump House and DAD Qtrs as required at site complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 ka, one No 160 Amps 4 pole 25 ka, two Nos 100 Amps 4 pole 25 ka, two No 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at near JCO Mess of COD Estate as required at site complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
M & L for Installation, commissioning and testing of LT panel cubical type suitable for outdoor factory made CPRI approved of suitable size , , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 600 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-10, suitable for and including one incoming MCCB 400 Amps 4 pole 35/36 ka, two Nos 200 Amps 4 pole 35/36 ka, one Nos 100 Amps 25 ka, two Nos 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at 12 Assam as required at site complete all as required at site or directed. Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Panel drawing shall be got approved by GE before incorporation.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 400 Amps 35/36 KA, thermal magnetic release. Make : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S
All as per item No 50 but MCCB 250 Amps 35/36 KA.
All as per item No 50 but MCCB 100 Amps 25 KA.
All as per item No 50 but MCCB 160 Amps 36 KA.
All as per item No 50 but 63 Amps 25 KA.
Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/3 M.
S & F in replacemet cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 (Gde E-165) grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed. (Note : (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
Disconnecting electrically, dismantling from foundation with due care and setting aside LT/HT fedder pillar box any type any size with all accessories.
Supply and installation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35/36 KA. complete all as required at site.Make of MCCB/MCbs : Legrand/Siemens / Schneider/L&T/Havells/ABB/Indo Asian/C&S Note: Drawing shall be got approved by GE before incorporation.
Supply & laying in replacement of GI tubing of 80 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Supply & laying in replacement of GI tubing of 50 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Supply & laying in replacement of GI tubing of 40 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Supply & laying in replacement of GI tubing of 20 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing of new hinges and other material as required at site complete all as spfd and directed.
Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not esceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M.
M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place as directed by Engineer-in-Charge.
Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.
M&L in replacement of Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 5 of SSR Part-I 2009 including taking down old unserviceable complete all as specified & directed by Engr-in-charge Note :- If the desired earth resistance is not found earthing shall be redone by the contractor at no extra cast to the department
M&L in replacement of Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable complete all as specified & directed by Engr-in-charge Note :- If the desired earth resistance is not found earthing shall be redone by the contractor at no extra cast to the department
Supply and fixing in replacement of PCC pit cover 50 mm thick complete with handle and angle iron frame for cover of required size as per sample incl PCC work all as required at site or directed.
M&L in replacement of earthing pits with , PCC M-15 (Nominal mix) incl excavation and earth work in any type of soil compete with funnel and 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6 mm dia MS bar all as direted by Engr-in-Charge.
Disconnecting, dismentling and taking down carefully single pointed air termination alumn rod incl GI pipe any size including nuts & bolts and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Disconnecting, dismentling and taking down carefully aluminum strip any size up to 32x6 mm complete with saddles GI tubing insulators and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Disconnecting, dismentling and taking down carefully GI strip of any size up to 32x6mm and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Fixing only single pointed air termination rod incl GI pipe obtained from site as per item No-76 above including nuts, bolts & suitable insulators for refixing air termination rod all as required at site or directed by Engr In Charge .
Fixing only aluminum strip any size complete obtained from site as per item No-77 above incl providing nut, bolt, saddles/ insulators and making joints by brazing or welding all as required at site or directed by Engr-in- Charge.
Fixing only GI strip obtained from site as per srl item No-78 above buried in ground upto 50 cm depth or fixed to wall etc including jointing by welding for loop earthing as directed by Engineer-in-Charge. (earth work will not be paid separately).
Supply and fix single pointed air termination alumn rod 12mm dia 300 mm long including insulator, nuts & bolts for fixing air termination rod to pole pipe all as required at site.
All as per srl item No 82 but 25mm dia 900mm long.
Supply and fix aluminum strip 25x3.15 mm complete incl providing nut, bolt & saddles/ insulators made out of porcelain or fibre for roof conductor/down conductor including welding or brazing for joints all as required at site or directed by Engr In Charge.
Supply & fix GI strip 32x6mm, buried in ground upto 50 cm depth or fixed to wall with nut, bolt & saddles/ insulators etc for loop earthing including welding for joints all as required at site or directed by Engr In Charge. (Note : Earth work will not be paid separately).
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm. Drilled and screwed incl 3 nos 8mm dia 25mm long hex head screw.
M&L for pre cast cement concrete ( 1:2:4) type B-1 using 20 mm graded stone aggregate for earth pits as mass concrete.
Bharat Sales Corporation
SAKSHAM SUPPLIERS BUILDERS
AUTOMATION AND SWITCHGEAR PANELS
U K Enterprises
Himanshu Construction and Suppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .