| 1.00 | M&L for Electrical safety energy audit of Main Recieving Station, Electric sub stations, HT/LT Switch gears, LT panel board and feeder piller boxes, HT/LT cable Net working system, water supply pumping installations and Air Conditioning Plants based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details :
(i) conducting survey of electric Sub stations -10 Nos.
(ii) conducting survey of Pump houses -17 Nos.
(iii) On ground site check of all LT Panel boards and feeder piller boxes.
(iv) Checking of earth resistance , Load balancing.
(v) Checking of loose connections.
(vi) Testing of APFC Panels and power factor Identification and devlopment of energy conservation opportunities.(ENCON)
(vii) Comparision and cost benefit analysis by low medium and long term measures.
(viii) Submission of energy audit report along with recommendations as per annexture. | 1 | Each Job | 4,24,999 ₹4.2 L | 3,90,000 ₹3.9 L |
| 2.00 | M & L for Electrical safety energy audit of LIFT Installations and Fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details :
(i) conducting survey of all high rise buildings from G+6 and above - 12 Nos. (ii) conducting survey of all high rise buildings upto G+6 - 27 Nos. (iii) On ground site check of all control Panel boards and fie panel boards, meter panels and DBs.
(iv) Checking of earth resistance in meter Room, Load balancing. (v) Checking of loose connections.
(vi) Identification and development of energy conservation opportunities.(ENCON). (vii) Comparision and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture.
Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY (ii) Energy audit service provider must be having minimum experience of 10 years with Central Govt and Statae Govt. (iii) Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter, magger etc. | 1 | Each Job | 4,09,999 ₹4.1 L | 3,05,000 ₹3.0 L |
| 3.00 | M & L for Electrical safety energy audit of buildings and fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details :
(i) conducting survey of all Machine Rooms of lift -26 Nos.
(ii) conducting survey of fire fighting Pump houses -5 Nos.
(iii) On ground site check of all control Panel boards and fire panel boards.
(iv) Checking of earth resistance in Machine Room , Load balancing.
(v) Checking of loose connections.
(vi) Identification and development of energy conservation opportunities.(ENCON).
(vii) Comparision and cost benefit analysis by low medium and long term measures.
(viii) Submission of energy audit report along with recommendations as per annexture.
Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY.
(ii) Energy audit service provider must be having minimum experience of 10 years with Central Govt and State Govt.
(iii) Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter, magger etc. | 1 | Each Job | 3,99,999 ₹4.0 L | 2,80,000 ₹2.8 L |
| 4.00 | Supply and fix Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 120 Sqmm x 3.5 core including disconnecting /getting out old unserviceable cable, complete all as specified and directed. | 50 | RM | 599 ₹29,950 | 1,155 ₹57,750 |
| 5.00 | All as per sl item No. 4 but for cable size 95 Sqmm x 3.5 Core. | 30 | RM | 579 ₹17,370 | 1,052 ₹31,560 |
| 6.00 | All as per sl item No. 4 but for cable size 70 Sqmm x 3.5 Core. | 30 | RM | 559 ₹16,770 | 835 ₹25,050 |
| 7.00 | All as per sl item No. 4 but for cable size 50 Sqmm x 3.5 Core. | 30 | RM | 529 ₹15,870 | 695 ₹20,850 |
| 8.00 | M&L for HT cable route tracing along with marking & erecting metallic HT cable route indicators each at distance of 7 meter, providing single line diagram of size on A1 sheet in glass frame on all 10 substations, complete all as specified and directed. | 3,000 | RM | 64 ₹1.9 L | 66 ₹2.0 L |
| 9.00 | M&L for LT cable route tracing along with marking & erecting metallic LT cable route indicators each at distance of 7 meter, providing shock tratment chart on on A1 sheet in glass frame on all 10 substation, complete all as specified and directed. | 15,000 | RM | 44 ₹6.6 L | 49.85 ₹7.5 L |
| 10.00 | Supply and fixing Standard operating procedure (SOP) for operation of Ring Main Unit (RMU) & Vaccum Circuiit Breakers (VCB) as per IS Standard all as directed by Engineer in charge. | 12 | Each | 8,999 ₹1.1 L | 500 ₹6,000 |
Updated dates
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 May 2026, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE(West), Colaba, Mumbai - 400 005
ENERGY AUDIT OF E/M INSTALLATION AND REPAIRS/RECTIFICATION OF CERTAIN CONNECTED ITEMS AT DUTY AREA UNDER GE (WEST) COLABA, MUMBAI
2026_MES_752017_2
8183/E8
Open Tender
Civil Works
180 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹70,000
Yes
8 Jun 2026
9 Apr 2026
4 May 2026
9 Apr 2026
1 May 2026
17 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
M&L for Electrical safety energy audit of Main Recieving Station, Electric sub stations, HT/LT Switch gears, LT panel board and feeder piller boxes, HT/LT cable Net working system, water supply pumping installations and Air Conditioning Plants based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details :
(i) conducting survey of electric Sub stations -10 Nos.
(ii) conducting survey of Pump houses -17 Nos.
(iii) On ground site check of all LT Panel boards and feeder piller boxes.
(iv) Checking of earth resistance , Load balancing.
(v) Checking of loose connections.
(vi) Testing of APFC Panels and power factor Identification and devlopment of energy conservation opportunities.(ENCON)
(vii) Comparision and cost benefit analysis by low medium and long term measures.
(viii) Submission of energy audit report along with recommendations as per annexture. | - | Each Job | - | - | itemH1Code1 | |
M & L for Electrical safety energy audit of LIFT Installations and Fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details :
(i) conducting survey of all high rise buildings from G+6 and above - 12 Nos. (ii) conducting survey of all high rise buildings upto G+6 - 27 Nos. (iii) On ground site check of all control Panel boards and fie panel boards, meter panels and DBs.
(iv) Checking of earth resistance in meter Room, Load balancing. (v) Checking of loose connections.
(vi) Identification and development of energy conservation opportunities.(ENCON). (vii) Comparision and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture.
Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY (ii) Energy audit service provider must be having minimum experience of 10 years with Central Govt and Statae Govt. (iii) Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter, magger etc. | - | Each Job | - | - | itemH1Code2 | |
M & L for Electrical safety energy audit of buildings and fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details :
(i) conducting survey of all Machine Rooms of lift -26 Nos.
(ii) conducting survey of fire fighting Pump houses -5 Nos.
(iii) On ground site check of all control Panel boards and fire panel boards.
(iv) Checking of earth resistance in Machine Room , Load balancing.
(v) Checking of loose connections.
(vi) Identification and development of energy conservation opportunities.(ENCON).
(vii) Comparision and cost benefit analysis by low medium and long term measures.
(viii) Submission of energy audit report along with recommendations as per annexture.
Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY.
(ii) Energy audit service provider must be having minimum experience of 10 years with Central Govt and State Govt.
(iii) Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter, magger etc. | - | Each Job | - | - | itemH1Code3 | |
Supply and fix Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 120 Sqmm x 3.5 core including disconnecting /getting out old unserviceable cable, complete all as specified and directed. | - | RM | - | - | itemH1Code4 | |
All as per sl item No. 4 but for cable size 95 Sqmm x 3.5 Core. | - | RM | - | - | itemH1Code5 | |
All as per sl item No. 4 but for cable size 70 Sqmm x 3.5 Core. | - | RM | - | - | itemH1Code6 | |
All as per sl item No. 4 but for cable size 50 Sqmm x 3.5 Core. | - | RM | - | - | itemH1Code7 | |
M&L for HT cable route tracing along with marking & erecting metallic HT cable route indicators each at distance of 7 meter, providing single line diagram of size on A1 sheet in glass frame on all 10 substations, complete all as specified and directed. | - | RM | - | - | itemH1Code8 | |
M&L for LT cable route tracing along with marking & erecting metallic LT cable route indicators each at distance of 7 meter, providing shock tratment chart on on A1 sheet in glass frame on all 10 substation, complete all as specified and directed. | - | RM | - | - | itemH1Code9 | |
Supply and fixing Standard operating procedure (SOP) for operation of Ring Main Unit (RMU) & Vaccum Circuiit Breakers (VCB) as per IS Standard all as directed by Engineer in charge. | - | Each | - | - | itemH1Code10 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_850943.xls
BOQ • 0.31 MB
8183TenderPages.pdf
Tender Documents • 1.36 MB
Download all tender documents and submit your bid