| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | ₹13.3 L Quoted ₹13.9 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹14.0 L+₹5,540 (0.40%)Rejected-Finance | ₹14.0 L+₹5,540 (0.40%) | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | L3₹14.5 L+₹57,204 (4.11%)Rejected-Finance | ₹14.5 L+₹57,204 (4.11%) | L3 | Rejected-Finance Being other than lowest tenderer |
| 4 | L4₹14.5 L+₹60,330 (4.34%)Rejected-Finance | ₹14.5 L+₹60,330 (4.34%) | L4 | Rejected-Finance Being other than lowest tenderer |
| 5 | L5₹14.7 L+₹83,375 (5.99%)Rejected-Finance | ₹14.7 L+₹83,375 (5.99%) | L5 | Rejected-Finance Being other than lowest tenderer |
| Sl No | Description | Qty | Unit | FG CONSTRUCTION L6 | FG CONSTRUCTION L6 | M/S GHULAM MOHI UD DIN RATHER L10 | M/S GULZAR ENTERPRISES L9 | M/S NEW FAROOQ TRADERS L1 | M/s Nasir Rasool Dar L4 | M/S KHAN ENTERPRISES L8 | M/S ZAHOOR ENTERPRISES L3 | M/S LATIF AHMED MIR L2 | M/S M.Y Enterprises L5 | M/S RATHER CONSTRUCTION CO L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repairing of unserviceable light point, Fan point, socket point 5A / 15A, switches, sockets or regulator, light fixtures any type any type MCBs, replacement of connected wire from ceiling rose to fitting etc in day to day / door to door maintenance and making it serviceable in all respect with provision of adhesive tape and screws & washers etc. Work shall also include to check & removal of breakages in service connection / sub main of houses as and when directed, complete all as specified and directed.
(All items such as switch / socket / switch socket combination / light fitting / regulator / MCBs, connection wire etc required to be replaced for this job will be measured seperately and paid under ser Item No 2.00 to 47.00 as supply only.)
Note : (a) Contractors representative / electrician will report to JE E/M / Engr-in-charge daily at forenoon and afternoon to collect routine / urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine / urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. | 800 | Per Job | 50 ₹40,000 | 50 ₹40,000 | 150 ₹1,20,000 | 20 ₹16,000 Lowest | 30 ₹24,000 | 80 ₹64,000 | 20 ₹16,000 Lowest | 80 ₹64,000 | 320 ₹2,56,000 | 29 ₹23,200 | 260 ₹2,08,000 |
| 1.01Note : (a) Contractors representative/engineer will report to JE E/M/Engr-in-charge daily at forenoon and afternoon to collect routine/urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. (b) The penalty shall be applicable to the contractor if the delay is noticed by the EIC more than 12 hrs after handing over works of urgent nature to the contractor. The Engr-In-Charge / JE E/M shall handover the slip containing specification of work to the contractor. The contractor shall attend the job immediately and report to Engr-In-Charge within 12hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12 hrs then the facts shall be brought to the notice of the GE / Engr-in-charge | ||||||||||||||
| 1.02and the period for the working to the complaint shall be decided by the GE / EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50.00 (Rs fifty only) per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding. (c) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same. (d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours (0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs) Other than the Regular complaints during working Hrs (0900 Hrs to 1700 Hrs) (e) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor. (f) If the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the govt. | ||||||||||||||
| 2.00 | Supply only Switch piano flush type SP, one way 5 Amps / 6 Amps 230 Volt. | 200 | Each | 24 ₹4,800 | 24 ₹4,800 | 35 ₹7,000 | 50 ₹10,000 | 20 ₹4,000 | 15 ₹3,000 Lowest | 22 ₹4,400 | 20 ₹4,000 | 60 ₹12,000 | 19 ₹3,800 | 35 ₹7,000 |
| 3.00 | Supply only Switch piano flush type SP, one way 15 Amps / 16 Amps, 230 Volt. | 200 | Each | 68 ₹13,600 | 68 ₹13,600 | 60 ₹12,000 | 100 ₹20,000 | 40 ₹8,000 Lowest | 80 ₹16,000 | 80 ₹16,000 | 100 ₹20,000 | 50 ₹10,000 | 90 ₹18,000 | 60 ₹12,000 |
| 4.00 | Supply only Switch socket combination 2 in1, 5 Amps, flush type, 230 Volt. | 200 | Each | 62 ₹12,400 Lowest | 62 ₹12,400 Lowest | 100 ₹20,000 | 150 ₹30,000 | 72 ₹14,400 | 80 ₹16,000 | 90 ₹18,000 | 110 ₹22,000 | 75 ₹15,000 | 85 ₹17,000 | 135 ₹27,000 |
| 5.00 | Supply only Switch socket combination 2 in1, 5 Amps / 15 Amps, flush type, 230 Volt. | 200 | Each | 145 ₹29,000 | 145 ₹29,000 | 240 ₹48,000 | 150 ₹30,000 | 105 ₹21,000 | 125 ₹25,000 | 130 ₹26,000 | 120 ₹24,000 | 70 ₹14,000 Lowest | 130 ₹26,000 | 145 ₹29,000 |
| 6.00 | Supply only Socket outlet 2 in 1, 5 pin, 5 Amps | 300 | Each | 39 ₹11,700 | 39 ₹11,700 | 60 ₹18,000 | 50 ₹15,000 | 45 ₹13,500 | 35 ₹10,500 Lowest | 70 ₹21,000 | 70 ₹21,000 | 70 ₹21,000 | 45 ₹13,500 | 100 ₹30,000 |
| 7.00 | Supply only Socket outlet, 2-in-1, 5 pin, 5 and 15 Amps flush | 300 | Each | 99 ₹29,700 | 99 ₹29,700 | 60 ₹18,000 Lowest | 130 ₹39,000 | 105 ₹31,500 | 85 ₹25,500 | 110 ₹33,000 | 80 ₹24,000 | 60 ₹18,000 Lowest | 105 ₹31,500 | 80 ₹24,000 |
| 8.00 | Supply only Switch piano flush type SP, two way 5 Amps 230 Volt. | 10 | Each | 24 ₹240 | 24 ₹240 | 45 ₹450 | 80 ₹800 | 40 ₹400 | 20 ₹200 Lowest | 60 ₹600 | 50 ₹500 | 50 ₹500 | 48 ₹480 | 80 ₹800 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Aug 2026, 6:00 pmClosed
GE (AF) SRINAGAR
Garrison Engineer (AF) Air Force Station Srinagar 190 007
CA NO. GE (AF)/SGR-42/2026-27 REPAIR / REPLACEMENT OF INTERNAL WIRING, SOCKET, SWITCHES ETC AND OTHER ALLIED WORKS AT TECHNICAL AREA UNDER GE (AF) SRINAGAR
2026_MES_779771_1
GE(AF)/SGR-42/2026-27
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (AF) SRINAGAR
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹50,000
Yes
27 Aug 2026
20 Jul 2026
13 Aug 2026
20 Jul 2026
11 Aug 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing of unserviceable light point, Fan point, socket point 5A / 15A, switches, sockets or regulator, light fixtures any type any type MCBs, replacement of connected wire from ceiling rose to fitting etc in day to day / door to door maintenance and making it serviceable in all respect with provision of adhesive tape and screws & washers etc. Work shall also include to check & removal of breakages in service connection / sub main of houses as and when directed, complete all as specified and directed.
(All items such as switch / socket / switch socket combination / light fitting / regulator / MCBs, connection wire etc required to be replaced for this job will be measured seperately and paid under ser Item No 2.00 to 47.00 as supply only.)
Note : (a) Contractors representative / electrician will report to JE E/M / Engr-in-charge daily at forenoon and afternoon to collect routine / urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine / urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. | 800 | Per Job | - | - |
| 1.02 | and the period for the working to the complaint shall be decided by the GE / EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50.00 (Rs fifty only) per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding.
(c) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.
(d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours (0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs) Other than the Regular complaints during working Hrs (0900 Hrs to 1700 Hrs)
(e) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor.
(f) If the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the govt. | - | - | - | - |
| 2 | Supply only Switch piano flush type SP, one way 5 Amps / 6 Amps 230 Volt. | 200 | Each | - | - |
| 3 | Supply only Switch piano flush type SP, one way 15 Amps / 16 Amps, 230 Volt. | 200 | Each | - | - |
| 4 | Supply only Switch socket combination 2 in1, 5 Amps, flush type, 230 Volt. | 200 | Each | - | - |
| 5 | Supply only Switch socket combination 2 in1, 5 Amps / 15 Amps, flush type, 230 Volt. | 200 | Each | - | - |
| 6 | Supply only Socket outlet 2 in 1, 5 pin, 5 Amps | 300 | Each | - | - |
| 7 | Supply only Socket outlet, 2-in-1, 5 pin, 5 and 15 Amps flush | 300 | Each | - | - |
| 8 | Supply only Switch piano flush type SP, two way 5 Amps 230 Volt. | 10 | Each | - | - |
| 9 | Suppy only bed Switch 5 Apms, 230 volts | 10 | Each | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.18 MB
BOQ_873402.xls
BOQ • 4.45 MB
Tender42.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .