Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹4.9 L
Closing Date
10 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
23 conditions · 12 needing a document upload
As per IRSGCC 2022 (including correction slips and amendments) as on date of publishing of tender
11.4. Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
11.5. Bid Capacity: The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of GCC April 2022.
11.6 Credentials if submitted in foreign currency shall be converted into Indian currency i.e., Indian Rupee as under: The conversion rate of US Dollars into Rupees shall be the daily representative exchange rates published by the Reserve Bank of India or entity authorized by RBI to do so for the relevant date or immediately previous date for which rates have been published. Where, relevant date shall be as on the last day of month previous to the one in which tender is invited. In case of any other currency, the same shall first be converted to US Dollars as on the last day of month previous to the one in which tender is invited, and the amount so derived in US Dollars shall be converted into Rupees at the aforesaid rate. The conversion rate of such currencies shall be the daily representative exchange rates published by the International Monetary Fund for the relevant date or immediately previous date for which rates have been published. [Explanation for Para 10 of the Tender Form (Second Sheet) including Para 10.1 to 10.5 - Eligibility Criteria: 1. Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender. 2. In case a work is started prior to 07 (seven) years, ending last day of month previous to the one in which tender is invited, but completed in last 07 (seven) years, ending last day of month previous to the one in which tender is invited, the completed work shall be considered for fulfillment of credentials. 3. If a work is physically completed and completion certificate to this extent is issued by the concerned organization but final bill is pending, such work shall be considered for fulfillment of credentials 4. In case of completed work, the value of final bill (gross amount) including the PVC amount (if paid) shall be considered as the completion cost of work. In case final bill is pending, only the total gross amount already paid including the PVC amount (if paid) shall be considered as the completion cost of work. In case of substantially completed work, the total gross amount already paid including the PVC amount (if paid), as mentioned in the certificate, shall be considered as the cost of substantially completed work
5. If a bidder has successfully completed a work as subcontractor and the work experience certificate has been issued for such work to the subcontractor by a Govt. Organization or public listed company as defined in Note for Item 10.1 Para 10 of the Tender Form (Second Sheet), the same shall be considered for the purpose of fulfillment of credentials. 6. In case a work is considered similar in nature for fulfillment of technical credentials, the overall cost including the PVC amount (if paid) of that completed work or substantially completed work, shall be considered and no separate evaluation for each component of that work shall be made to decide eligibility. 7. In case of newly formed partnership firm, the credentials of individual partners from previous propriety firm(s) or dissolved previous partnership firm(s) or split previous partnership firm(s), shall be considered only to the extent of their share in previous entity on the date of dissolution / split and their share in newly formed partnership firm. For example, a partner A had 30% share in previous entity and his share in present partnership firm is 20%. In the present tender under consideration, t 8. he credentials of partner A will be considered to the extent of 0.3*0.2*value of the work done in the previous entity. For this purpose, the tenderer shall submit along with his bid all the relevant documents which include copy of previous partnership deed(s), dissolution deed(s) and proof of surrender of PAN No.(s) in case of dissolution of partnership firm(s) etc. 9. In case of existing partnership firm, if any one or more partners quit the partnership firm, the credentials of remaining partnership firm shall be re-worked out i.e., the quitting partner(s) shall take away his credentials to the extent of his share on the date of quitting the partnership firm (e.g. in a partnership firm of partners A, B & C having share 30%, 30% & 40% respectively and credentials of Rs 10 crore; in case partner C quits the firm, the credentials of this partnership firm shall remain as Rs 6 crore). For this purpose, the tenderer shall submit along with his bid all the relevant documents which include copy of previous partnership deed(s), dissolution deed(s) and proof of surrender of PAN No.(s) in case of dissolution of partnership firm(s) etc. 10. In case of existing partnership firm if any new partner(s) joins the firm without any modification in the name and PAN/TAN no. of the firm, the credentials of partnership firm shall get enhanced to the extent of credentials of newly added partner(s) on the same principles as mentioned in item 6 above. For this purpose, the tenderer shall submit along with his bid all the relevant documents which include copy of previous partnership deeds, dissolution/splitting deeds and proof of surrender of PAN No. (s) in case of dissolution of partnership firm etc. 11. Any partner in a partnership firm cannot use or claim his credentials in any other firm without leaving the partnership firm i.e., In a partnership firm of A&B partners, A or B partner cannot use credentials of partnership firm of A&B partners in any other partnership firm or propriety firm without leaving partnership firm of A&B partners.
12. In case a partner in a partnership firm is replaced due to succession as per succession law, the proportion of credentials of the previous partner will be passed on to the successor 13. If the percentage share among partners of a partnership firm is changed, but the partners remain the same, the credentials of the firm before such modification in the share will continue to be considered for the firm as it is without any change in their value. Further, in case a partner of partnership firm retires without taking away any credentials from the firm, the credentials of partnership firm shall remain the same as it is without any change in their value. 14. In a partnership firm "AB" of A&B partners, in case A also works as propriety firm "P" or partner in some other partnership firm "AX", credentials of A in propriety firm "P" or in other partnership firm "AX" earned after the date of becoming a partner of the firm AB shall not be added in partnership firm AB. 15. In case a tenderer is LLP, the credentials of tenderer shall be worked out on above lines similar to a partnership firm. 16. In case company A is merged with company B, then company B would get the credentials of company A also.
As per IRSGCC 2022 (including correction slips and amendments) as on date of publishing
Electrical License : The individual/firm should have valid "A" grade electrical license and should be on their own name/firm name issued by the competent Authority. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
11.3(i) Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last07(seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
(b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components.(b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity.(b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarized, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakhs, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing.
Note for Item 11.3(ii): Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs.500 crore and above in last 3 financial years excluding the current financial year, listed on National StockPa Egex c2h7/a3n3ge or financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case of non submission of such certificates, tender will be summarily rejected. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. (a) For Works without composite components The technical eligibility for the work as per para 10.1 above, shall be satisfied by either the ' JV in its own name & style' or 'Lead member of the JV'. Each other (non-lead) member(s) of JV, who is/ are not satisfying the technical eligibility for the work as per para l0.l above, shall have technical capacity of minimum 10% of the cost of work i.e., each non-lead member of JV member must have satisfactorily completed or substantially completed during the last 07 (seven) years, ending last day of month previous to the one in which tender is invited, one similar single work for a minimum off 10% of advertised value of the tender. (b) For works with composite components The technical eligibility for major component of work as per para l0.l above, shall be satisfied by either the 'JV in its own name & style' or 'Lead member of the JV' and technical eligibility for other component(s) of work as per para 10.1 above, shall be satisfied by either the 'JV in its own name & style' or 'any member of the JV'. Each other(non-lead)member(s)of JV, who is /are not satisfying the technical eligibility for any component of the work as per-par l0.l above, shall have technical capacity of minimum 10% of the cost of any component of work mentioned in technical eligibility criteria. i.e., each other (nonlead) member of must have satisfactorily completed or substantially completed during the last 07 (seven) years, ending last day of month previous to the one in which tender is invited, one similar single work for a minimum- of 10% of cost of any component of work mentioned in technical eligibility criteria. Note for Para 17.15.1:a) The major component of the work for this purpose shall be the component of work having highest value. In cases where value of two or more component of work is same, any one work can be classified as Major component of work b)Value of a completed work done by a Member in an earlier JV shall be reckoned only to the extent of the concerned member's share in that JV for the purpose of satisfying his/her compliance to the above mentioned technical eligibility criteria in the tender under consideration.
Similar nature of work: - "Works of wiring /cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements earthings etc. (with or without supply of items/equipments) for 230 V, 1 phase or 415 V, 3 phase system or higher voltages." (Ref: Hqrs Lr.No:E.29/P/Similar nature of works Dt: 30.12.2014.)
28 conditions · 11 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
For the tender value above Rs.20.0 crores, the tenderers should submit Bid capacity statement in the prescribed proforma (As per GCC) duly verified by Chartered Accountant. In case, the tenderer/s failed to upload Bid Capacity Proforma along with offer, their /his offer shall be considered as incomplete and will be rejected summarily
Tender value is including escalation of (-)10% (minus ten percent) on CPWD DSR rates. Tenderer should note this before quoting the rates.
The original Bank Guarantee (in lieu of Bid Security) should be delivered in person to the official nominated (i.e OS/Tenders/GS/SC Division) as indicated in the tender document Before closing date for submission of bids. (i.e. excluding the last date of submission of Bids).
All the instructions furnished in the Technical Compliance / Commercial Compliance / Custom / Undertakings / General instructions are only indicative and not exhaustive. The tenderer shall read the GCC / Tender documents for complete details.
The tenderer shall thoroughly go through the entire tender documents and strictly adhere to the instructions and directions given therein.
Gati Shakti - Secunderabad Division - SC-WADI & VKB-PRLI Section : (i) Proposed Parli Vaijanath station for connecting Parli vaijnath- Latur Road & Parli vaijnath -Parbhani Main lines - Electrical Arrangements (ii) Proposed New Byepass Line at Latur Road station for connecting Latur Road - Parli vaijnath & Latur Road - Kurduwadi Main lines - Electrical Arrangements
C-E-GS-SC-4-OT-2026-27
C-E-GS-SC-4-OT-2026-27
Open
Works - General
9 Months
Hyderabad, Telangana
₹0
₹4.9 L
10 Jul 2026
18 Jun 2026
26 Jun 2026
795 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Below/Par | ||
| — | — | — | 1,68,30,204.38 | ||
| — | 14.00 | — | — | ||
| Concrete for foundations and plinth in hard soil. | — | — | — | 60,088 | |
| — | 2600.00 | — | — | ||
| Supply of 25mm size PVC rigid conduit pipe of 2mm thickness as per BIS-9537 (latest) along with accessories. | — | — | — | 67,600 | |
| — | 2600.00 | — | — | ||
| Erection of 25mm size PVC rigid conduit pipe of 2mm thickness along with accessories. | — | — | — | 7,800 | |
| — | 2800.00 | — | — | ||
| Supply of 32mm PVC rigid conduit pipes of 2mm thickness as per BIS-9537 (latest) along with accessories. | — | — | — | 98,000 | |
| — | 2800.00 | — | — | ||
| Erection of 32mm PVC rigid conduit pipes of 2mm thickness along with accessories. | — | — | — | 11,200 | |
| — | 96.00 | — | — | ||
| Supply of 50mm PVC rigid conduit pipes of 2mm thickness as per BIS-9537 (latest) along with accessories. | — | — | — | 6,048 | |
| — | 96.00 | — | — | ||
| Erection of 50mm PVC rigid conduit pipes of 2mm thickness along with accessories. | — | — | — | 768 | |
| — | 144.00 | — | — | ||
| Supply of 50mm size 'B' class GI pipe as per IS:1239 along with accessories. | — | — | — | 42,048 | |
| — | 144.00 | — | — | ||
| Erection of 50mm size 'B' class GI pipe along with accessories. | — | — | — | 5,760 | |
| — | 342.00 | — | — | ||
| Supply of 100mm size 'B' class GI pipe as per IS:1239 along with accessories. | — | — | — | 2,34,612 | |
| — | 342.00 | — | — | ||
| Erection of 100mm size 'B' class GI pipe along with accessories. | — | — | — | 32,832 | |
| — | 5010.00 | — | — | ||
| Supply of 63mm of HDPE pipes of Grade PE-100, PN 6 (6Kg/Cm2 Capacity) with accessories as per IS 4984 - 2016 (SDR-21) or latest | — | — | — | 4,75,950 | |
| — | 5010.00 | — | — | ||
| Erection of 63mm of HDPE pipes of Grade PE-100, PN 6 (6Kg/Cm2 Capacity) with accessories | — | — | — | 65,130 | |
| — | 1300.00 | — | — | ||
| Supply of 110 mm of HDPE pipes of Grade PE-100, PN 6 (6Kg/Cm2 Capacity) with accessories as per IS 4984 - 2016 (SDR-21) or latest | — | — | — | 3,87,400 | |
| — | 1300.00 | — | — | ||
| Erection of 110 mm of HDPE pipes of Grade PE-100, PN 6 (6Kg/Cm2 Capacity) with accessories | — | — | — | 53,300 | |
| — | 600.00 | — | — | ||
| Supply of 40mm HDPE pipes of Grade PE-100, PN 16 (16Kg/Cm2 Capacity) with accessories as per IS 4984 - 2016 or latest | — | — | — | 49,800 | |
| — | 600.00 | — | — | ||
| Erection of 40mm HDPE pipes of Grade PE-100, PN 16 (16Kg/Cm2 Capacity) with accessories | — | — | — | 6,600 | |
| — | 360.00 | — | — | ||
| Supply of 50mm of HDPE pipes of Grade PE-100, PN 16 (16Kg/Cm2 Capacity) with accessories as per IS 4984 - 2016 (SDR-21) or latest | — | — | — | 46,800 | |
| — | 360.00 | — | — | ||
| Erection of 50mm of HDPE pipes of Grade PE-100, PN 16 (16Kg/Cm2 Capacity) with accessories | — | — | — | 6,480 | |
| — | 3000.00 | — | — | ||
| Cutting and chipping the wall for laying the PVC conduit pipe and plastering after laying the PVC conduit pipe with cement and sand mortar mixed with 1:8 ratio, but without laying PVC conduit pipe. | — | — | — | 1,17,000 | |
| — | 12.00 | — | — | ||
| Supply of 1 or 2 module GI concealed sheet metal box | — | — | — | 396 | |
| — | 12.00 | — | — | ||
| Erection of 1 or 2 module GI concealed sheet metal box | — | — | — | 48 | |
| — | 42.00 | — | — | ||
| Supply of 3 module GI concealed sheet metal box | — | — | — | 1,932 | |
| — | 42.00 | — | — | ||
| Erection of 3 module GI concealed sheet metal box | — | — | — | 252 | |
| — | 81.00 | — | — | ||
| Supply of 6 module GI concealed sheet metal box | — | — | — | 6,075 | |
| — | 81.00 | — | — | ||
| Erection of 6 module GI concealed sheet metal box | — | — | — | 810 | |
| — | 30.00 | — | — | ||
| Supply of 8 or 9 module GI concealed sheet metal box | — | — | — | 2,940 | |
| — | 30.00 | — | — | ||
| Erection of 8 or 9 module GI concealed sheet metal box | — | — | — | 390 | |
| — | 34.00 | — | — | ||
| Supply of 12 module GI concealed sheet metal box | — | — | — | 4,114 | |
| — | 34.00 | — | — | ||
| Erection of 12 module GI concealed sheet metal box | — | — | — | 544 | |
| — | 12.00 | — | — | ||
| Supply of 1 or 2 module plate-solid white | — | — | — | 552 | |
| — | 12.00 | — | — | ||
| Erection of 1 or 2 module plate-solid white | — | — | — | 84 | |
| — | 42.00 | — | — | ||
| Supply of 3 module plate-solid white | — | — | — | 2,436 | |
| — | 42.00 | — | — | ||
| Erection of 3 module plate-solid white | — | — | — | 336 | |
| — | 81.00 | — | — | ||
| Supply of 6 module plate-solid white | — | — | — | 8,829 | |
| — | 81.00 | — | — | ||
| Erection of 6 module plate-solid white | — | — | — | 1,215 | |
| — | 30.00 | — | — | ||
| Supply of 8 or 9 module plate-solid white | — | — | — | 4,200 | |
| — | 30.00 | — | — | ||
| Erection of 8 or 9 module plate-solid white | — | — | — | 570 | |
| — | 34.00 | — | — | ||
| Supply of 12 module plate-solid white | — | — | — | 5,916 | |
| — | 34.00 | — | — | ||
| Erection of 12 module plate-solid white | — | — | — | 816 | |
| — | 439.00 | — | — | ||
| Supply of 6/10A 1-way modular switch | — | — | — | 17,121 | |
| — | 439.00 | — | — | ||
| Erection of 6/10A 1-way modular switch | — | — | — | 2,195 | |
| — | 262.00 | — | — | ||
| Supply of 6/10A multi socket for cell phone pin or 2pin +3 pin with safety shutter | — | — | — | 23,842 | |
| — | 262.00 | — | — | ||
| Erection of 6/10A multi socket for cell phone pin or 2pin +3 pin with safety shutter | — | — | — | 3,144 | |
| — | 156.00 | — | — | ||
| Supply of 6/16A or 10/20A twin socket heavy duty socket with safety shutter | — | — | — | 24,180 | |
| — | 156.00 | — | — | ||
| Erection of 6/16A or 10/20A twin socket heavy duty socket with safety shutter | — | — | — | 3,276 | |
| — | 144.00 | — | — | ||
| Supply of 16/20A one way modular switch | — | — | — | 12,816 | |
| — | 144.00 | — | — | ||
| Mark | Each | — | — | ||
| Erection of 16/20A one way modular switch | — | — | — | 1,728 | |
| — | 40.00 | — | — | ||
| Supply of 5 step fan regulator 2Module | — | — | — | 11,840 | |
| — | 40.00 | — | — | ||
| Erection of 5 step fan regulator 2Module | — | — | — | 1,640 | |
| — | 392.00 | — | — | ||
| Supply of Ceiling rose (3-terminal). | — | — | — | 8,624 | |
| — | 392.00 | — | — | ||
| Erection of Ceiling rose (3-terminal). | — | — | — | 1,176 | |
| — | 8000.00 | — | — | ||
| Supply of 3 Nos.. of 1.5 Sq.mm FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 3,92,000 | |
| — | 8000.00 | — | — | ||
| Erection of 3 Nos.. of 1.5 Sq.mm FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 48,000 | |
| — | 3600.00 | — | — | ||
| Supply of 2 Nos.. of 2.5 Sq.mm, 1No. 1.5 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 2,30,400 | |
| — | 3600.00 | — | — | ||
| Erection of 2 Nos.. of 2.5 Sq.mm, 1No. 1.5 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 28,800 | |
| — | 3600.00 | — | — | ||
| Supply of 2 Nos.. of 4.0 Sq.mm, 1No. 2.5 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 3,45,600 | |
| — | 3600.00 | — | — | ||
| Erection of 2 Nos.. of 4.0 Sq.mm, 1No. 2.5 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 43,200 | |
| — | 1200.00 | — | — | ||
| Supply of 4No.s of 4.0 sq. mm, 1No. 2.5 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 1,78,800 | |
| — | 1200.00 | — | — | ||
| Erection of 4No.s of 4.0 sq. mm, 1No. 2.5 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 24,000 | |
| — | 500.00 | — | — | ||
| Supply of 4No.s of 10 sq. mm, 1No. 6 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 1,83,500 | |
| — | 500.00 | — | — | ||
| Erection of 4No.s of 10 sq. mm, 1No. 6 sq.mm of FRLS PVC insulated flexible multistrand copper wire including earth continuity wire . | — | — | — | 25,500 | |
| — | 200.00 | — | — | ||
| Supply of single core multi strand 16 sq. mm FRLS Copper Cable | — | — | — | 36,400 | |
| — | 200.00 | — | — | ||
| Laying, connecting & commissioning of single core multi strand 16 sq. mm FRLS Copper Cable | — | — | — | 3,600 | |
| — | 280.00 | — | — | ||
| Supply of 25 Sq.mm FRLS PVC insulated flexible single core multistrand copper wire including earth continuity wire as per IS:694 or latest | — | — | — | 86,800 | |
| — | 280.00 | — | — | ||
| Erection of 25 Sq.mm FRLS PVC insulated flexible single core multistrand copper wire including earth continuity wire | — | — | — | 8,680 | |
| — | 220.00 | — | — | ||
| Supply of Single Core 50 Sq.mm Copper Wire | — | — | — | 1,34,640 | |
| — | 220.00 | — | — | ||
| Erection of Single Core 50 Sq.mm Copper Wire | — | — | — | 13,420 | |
| — | 960.00 | — | — | ||
| Supply of 3 core 4.0 sq.mm flat copper cable suitable for submiersible pump | — | — | — | 80,640 | |
| — | 960.00 | — | — | ||
| Erection of 3 core 4.0 sq.mm flat copper cable suitable for submiersible pump | — | — | — | 10,560 | |
| — | 2800.00 | — | — | ||
| Supply of Two core 70 sqmm size LTUG XLPE Aluminium armoured cable to IS 7098 Part I complete with end terminations | — | — | — | 5,57,200 | |
| — | 2800.00 | — | — | ||
| Erection of Two core 70 sqmm size LTUG XLPE Aluminium armoured cable complete with end terminations | — | — | — | 78,400 | |
| — | 1600.00 | — | — | ||
| Supply of Two core 150 sq.mm armoured XLPE Aluminum cables to IS 7098 PART I (latest) complete with end terminations | — | — | — | 6,41,600 | |
| — | 1600.00 | — | — | ||
| Laying of Two core 150 sq.mm armoured XLPE Aluminum cables complete with end terminations | — | — | — | 62,400 | |
| — | 3600.00 | — | — | ||
| Supply of 4 core 16 Sqmm size LTUG XLPE aluminium armoured cable to IS 7098 Part I complete end terminations | — | — | — | 5,58,000 | |
| — | 3600.00 | — | — | ||
| Erection of 4 core 16 Sqmm size LTUG XLPE aluminium armoured cable complete with end terminations | — | — | — | 72,000 | |
| — | 1200.00 | — | — | ||
| Supply of 4 core 50 Sqmm size LTUG XLPE aluminium armoured cable as per IS 7098 Part I alongwith end terminations | — | — | — | 4,18,800 | |
| — | 1200.00 | — | — | ||
| Erection of 4 core 50 Sqmm size LTUG XLPE aluminium armoured cable alongwith end terminations | — | — | — | 58,800 | |
| — | 9200.00 | — | — | ||
| Supply of 8SWG GI wire | — | — | — | 82,800 | |
| — | 9200.00 | — | — | ||
| Erection of 8SWG GI wire | — | — | — | 9,200 | |
| — | 15.00 | — | — | ||
| Supply of Heavy duty exhaust fan generally confirming to IS 2312 (latest) and shall meet the following requirement: (a) diameter of the fan - 300 mm (12 inches), (b) speed - 900 RPM, (c) Input power - 55 watts, (d)operating voltage - 230 V AC, 50 Hz, 1 phase, (e) Air delivery - 1250 cmh. | — | — | — | 39,736.5 | |
| — | 15.00 | — | — | ||
| Erection of Heavy duty exhaust fan generally confirming to IS 2312 (latest) and shall meet the following requirement: (a) diameter of the fan - 300 mm (12 inches), (b) speed - 900 RPM, (c) Input power - 55 watts, (d)operating voltage - 230 V AC, 50 Hz, 1 phase, (e) Air delivery - 1250 cmh. | — | — | — | 3,973.65 | |
| — | 84.00 | — | — | ||
| Supply of energy efficient 230V, 50Hz a.c 1400mm sweep, 32W BLDC motor Energy Saving Ceiling Fan with Remote Control. | — | — | — | 3,74,892 | |
| — | 84.00 | — | — | ||
| Fixing, testing and commissioning of energy efficient 230V, 50Hz a.c 1400mm sweep, 32W BLDC motor Energy Saving Ceiling Fan with Remote Control. | — | — | — | 37,464 | |
| — | 152.00 | — | — | ||
| Supply of 6/10/16/20/25/32A, C-curve SP MCBs with 10KA breaking capacity | — | — | — | 18,544 | |
| — | 152.00 | — | — | ||
| Erection of 6/10/16/20/25/32A, C-curve SP MCBs with 10KA breaking capacity | — | — | — | 2,584 | |
| — | 13.00 | — | — | ||
| Supply of 6/10/16/20/25/32A, C-curve DP MCBs with 10KA breaking capacity | — | — | — | 5,161 | |
| — | 13.00 | — | — | ||
| Erection of 6/10/16/20/25/32A, C-curve DP MCBs with 10KA breaking capacity | — | — | — | 715 | |
| — | 28.00 | — | — | ||
| Supply of 6/10/16/20/25/32A, C-curve TP MCBs with 10KA breaking capacity | — | — | — | 22,708 | |
| — | 28.00 | — | — | ||
| Erection of 6/10/16/20/25/32A, C-curve TP MCBs with 10KA breaking capacity | — | — | — | 3,164 | |
| — | 15.00 | — | — | ||
| Supply of 6/10/16/20/25/32A, C-curve FP MCBs with 10KA breaking capacity | — | — | — | 12,960 | |
| — | 15.00 | — | — | ||
| Erection of 6/10/16/20/25/32A, C-curve FP MCBs with 10KA breaking capacity | — | — | — | 1,815 | |
| — | 6.00 | — | — | ||
| Supply of 50/63A, C-curve SP MCB with 10KA breaking capacity | — | — | — | 2,688 | |
| — | 6.00 | — | — | ||
| Erection of 50/63A, C-curve SP MCB with 10KA breaking capacity | — | — | — | 264 | |
| — | 4.00 | — | — | ||
| Supply of 50/63A, C-curve DP MCB with 10KA breaking capacity | — | — | — | 2,640 | |
| — | 4.00 | — | — | ||
| Erection of 50/63A, C-curve DP MCB with 10KA breaking capacity | — | — | — | 368 | |
| — | 4.00 | — | — | ||
| Supply of 16/25A ,C-Curve 30mA DP RCBO | — | — | — | 19,993.92 | |
| — | 4.00 | — | — | ||
| Erection of 16/25A ,C-Curve 30mA DP RCBO | — | — | — | 999.68 | |
| — | 2.00 | — | — | ||
| Supply of 32A,C-Curve 30mA DP RCBO | — | — | — | 10,846.56 | |
| — | 2.00 | — | — | ||
| Erection of 32A,C-Curve 30mA DP RCBO | — | — | — | 542.32 | |
| — | 1.00 | — | — | ||
| Supply of 25A,C-Curve 100mA FP RCBO | — | — | — | 6,329.52 | |
| — | 1.00 | — | — | ||
| Erection of 25A,C-Curve 100mA FP RCBO | — | — | — | 316.48 | |
| — | 11.00 | — | — | ||
| Supply of 32A,C-Curve 100mA FP RCBO | — | — | — | 70,390.54 | |
| — | 11.00 | — | — | ||
| Erection of 32A,C-Curve 100mA FP RCBO | — | — | — | 3,519.56 | |
| — | 11.00 | — | — | ||
| Supply of SPN 12 way Double door DB. | — | — | — | 16,665 | |
| — | 11.00 | — | — | ||
| Erection of SPN 12 way Double door DB. | — | — | — | 2,332 | |
| — | 6.00 | — | — | ||
| Supply of 6 way TPN Double door distribution board (Single phase outgoing MCB incomer) | — | — | — | 28,104 | |
| — | 6.00 | — | — | ||
| Erection of 6 way TPN Double door distribution board (Single phase outgoing MCB incomer) | — | — | — | 3,930 | |
| — | 3.00 | — | — | ||
| Supply of 12 way vertical Double door TPN distribution board MCCB as incomer | — | — | — | 17,628 | |
| — | 3.00 | — | — | ||
| Erection of 12 way vertical Double door TPN distribution board MCCB as incomer | — | — | — | 2,466 | |
| — | 2.00 | — | — | ||
| Supply of 25A DP RCCB with 100/300mA sensitivity | — | — | — | 3,796 | |
| — | 2.00 | — | — | ||
| Erection of 25A DP RCCB with 100/300mA sensitivity | — | — | — | 530 | |
| — | 3.00 | — | — | ||
| Supply of 63A FP RCCB with 100mA sensitivity | — | — | — | 6,411 | |
| — | 3.00 | — | — | ||
| Erection of 63A FP RCCB with 100mA sensitivity | — | — | — | 897 | |
| — | 1.00 | — | — | ||
| Design, fabrication & supply of Sheet Steel Enclosure Outdoor type LT panel board ( Powder coated RAL 7032 ) with suitable Busbar capacity including supply and fixing of digital voltmeter, digital ammeter with CTS, indication lamps complete with all accessories, for housing of 2x 160A FP MCCB , 250A FP Onload COS and Digital Multifunctional panel meter etc. (Before fabrication drawing approval is to be taken from Dy.CEE/GS/SC) | — | — | — | 30,000 | |
| — | 1.00 | — | — | ||
| Erection, testing & commissioning of Sheet Steel Enclosure Outdoor type LT panel board ( Powder coated RAL 7032 ) with suitable Busbar capacity including supply and fixing of digital voltmeter, digital ammeter with CTS, indication lamps complete with all accessories, for housing of 2x 160A FP MCCB , 250A FP Onload COS and Digital Multifunctional panel meter etc. (Before fabrication drawing approval is to be taken from Dy.CEE/GS/SC) | — | — | — | 2,500 | |
| — | 3.00 | — | — | ||
| Design, fabrication & supply of Sheet Steel Enclosure wall mounted type LT panel board (Powder coated RAL 7032 ) including supply and fixing of digital voltmeter, digital ammeter with CTS, indication lamps complete with all accessories for housing of 1x100A FP MCCB, 1x32A FP MCB, 1x20A DP MCB, 24x16A SP MCB,5 No.s of Timers, 5 No.s of 40A contactors complete with wiring, timers & contactors, metering & complete switchgear components. (Before fabrication drawing approval is to be taken from Dy.CEE/GS/SC) | — | — | — | 1,80,000 | |
| — | 3.00 | — | — | ||
| Erection, testing & commissioning of Sheet Steel Enclosure wall mounted type LT panel board (Powder coated RAL 7032 ) including supply and fixing of digital voltmeter, digital ammeter with CTS, indication lamps complete with all accessories for housing of 1x100A FP MCCB, 1x32A FP MCB, 1x20A DP MCB, 24x16A SP MCB,5 No.s of Timers, 5 No.s of 40A contactors complete with wiring, timers & contactors, metering & complete switchgear components. (Before fabrication drawing approval is to be taken from Dy.CEE/GS/SC) | — | — | — | 30,000 | |
| — | 3.00 | — | — | ||
| Design, fabrication & supply of Sheet Steel Enclosure Outdoor type LT panel board ( Powder coated RAL 7032 ) suitable for Mounting of 3No.s of 3Phase Energy Meter ,4 No.s with 160A 4Pole MCCB,1No. of 250A 4Pole COS along with indication | — | — | — | 2,40,000 | |
| — | 3.00 | — | — | ||
| Erection, testing & commissioning of Sheet Steel Enclosure Outdoor type LT panel board ( Powder coated RAL 7032 ) suitable for Mounting of 3No.s of 3Phase Energy Meter ,4 No.s with 160A 4Pole MCCB,1No. of 250A 4Pole COS along with indication | — | — | — | 24,000 | |
| — | 2.00 | — | — | ||
| Design, fabrication & supply of Sheet Steel Enclosure Outdoor/Indoor type LT panel board ( Powder coated RAL 7032 ) with suitable Busbar capacity including supply and fixing of digital voltmeter, digital ammeter with CTS, indication lamps complete with all accessories, for housing of 1x250A FP MCCB , 2x100A FP MCCBs, 6x63A FP MCCB,4 x32A 4P MCB, 250A FP Onload COS and Digital Multifunctional panel meter etc. (Before fabrication drawing approval is to be taken from Dy.CEE/GS/SC) | — | — | — | 1,50,000 | |
| — | 2.00 | — | — | ||
| Erection, testing & commissioning of Sheet Steel Enclosure Outdoor/Indoor type LT panel board ( Powder coated RAL 7032 ) with suitable Busbar capacity including supply and fixing of digital voltmeter, digital ammeter with CTS, indication lamps complete with all accessories, for housing of 1x250A FP MCCB , 2x100A FP MCCBs, 6x63A FP MCCB,4 x32A 4P MCB, 250A FP Onload COS and Digital Multifunctional panel meter etc. (Before fabrication drawing approval is to be taken from Dy.CEE/GS/SC) | — | — | — | 30,000 | |
| — | 2.00 | — | — | ||
| Supply of 250A 4 pole MCCB with 36KA breaking capacity with LSIG Micro processor based release with spereder links(4 nos-02 sets), phase barriers | — | — | — | 53,999 | |
| — | 2.00 | — | — | ||
| Erection of 250A 4 pole MCCB with 36KA breaking capacity with LSIG Micro processor based release with spereder links (4 nos-02 sets), phase barriers | — | — | — | 5,399.9 | |
| — | 14.00 | — | — | ||
| Supply of 160A 4 pole MCCB with 25KA breaking capacity with with LSIG Micro processor based release with spereder links (4 nos-02 sets), phase barriers | — | — | — | 3,47,578 | |
| — | 14.00 | — | — | ||
| Erection of 160A 4 pole MCCB with 25KA breaking capacity with with LSIG Micro processor based release with spereder links(4 nos-02 sets), phase barriers | — | — | — | 34,757.8 | |
| — | 21.00 | — | — | ||
| Supply of 63A/100A 4 pole MCCB with 25KA breaking capacity with Adjustable thermal magnetic release with spereder links (4 nos-02 sets), phase barriers | — | — | — | 1,18,156.5 | |
| — | 21.00 | — | — | ||
| Erection of 63A/100A 4 pole MCCB with 25KA breaking capacity with Adjustable thermal magnetic release with spereder links (4 nos-02 sets), phase barriers | — | — | — | 11,815.65 | |
| — | 6.00 | — | — | ||
| Supply of 250 A 4P On-load Change over switch in open execution with complete with accessories etc. | — | — | — | 99,889.2 | |
| — | 6.00 | — | — | ||
| Erection of 250 A 4P On-load Change over switch in open execution with complete with accessories etc. | — | — | — | 4,994.46 | |
| — | 288.00 | — | — | ||
| Horizontal drilling of bores for laying of pipe for drawing cable | — | — | — | 3,65,472 | |
| — | 3000.00 | — | — | ||
| Excavation of cable trench in all kinds of Soil | — | — | — | 3,90,000 | |
| — | 200.00 | — | — | ||
| Excavation of cable trench in Tar road surface as per the Rly specification No:C/E/UGC/1/92& Drg No:SC/A3/STD/1288 Alt-I | — | — | — | 43,200 | |
| — | 200.00 | — | — | ||
| Excavation of cable trench incement concrete bed flooring | — | — | — | 81,000 | |
| — | 10.00 | — | — | ||
| Supply and erection of earth electrode | — | — | — | 34,983.8 | |
| — | 18.00 | — | — | ||
| "Supply of earth pit materials and construction of earth pit as per IS 3043:1987 specification. This item also includesof supply anderection of CI pipe of size of 100mm inner diameter,13mm thickness and 3000 mm length.This work also includes of fabrication and fixing of GI strips for earthing connection. Excavated earth pit should be filled by mixture of coke/charcoal, salt and sand upto top. Provision of brick masonry chamber of size 650 mm x 650 mm and depth upto1000mm including light type CI coverframe and applying 12mm thick cement plaster in 1:3 inside and to all the exposed faces up to 300mm below. Foundation level, curing etc., All required materials for this job such as CI pipe cover with frame, salt,cement sand, charcoal gravel, bricks, etc.required bolts, nuts and double washers, number plates or painted plates. Tentative quantity of salt and charcoal shall be of 2.5 CMt. The CI pipe should be painted with 2coats of bitumen paint as per the directions of Rly engineer at site. Note: The work should be strictly done as per IS 3043:1987 specification or latest. " | — | — | — | 1,56,600 | |
| — | 200.00 | — | — | ||
| Supply of flexible cable organisor of 3/4" size | — | — | — | 5,000 | |
| — | 200.00 | — | — | ||
| Erection of flexible cable organisor of 3/4" size | — | — | — | 1,000 | |
| — | 30.00 | — | — | ||
| Supply of 05 mtrs long dip galvanised octogonal pole with 130 mm bottom A/F & 70 mm top A/F made up of 3 mm thick HT sheet along with base plate of size 200 x 200x12mm, M16x600 long 'J' type EN 8 grade foundation bolts., 1000 mm long single/double arm bracket (as per site requirement) with concrete foundation and plinth in hard soil including excation of soil, tamping of concrete grouting with Bakelite sheet and MCB(for mounting inside the base compartment of pole) with all accessories. | — | — | — | 3,14,520 | |
| — | 30.00 | — | — | ||
| Erection of 05 mtrs long dip galvanised octogonal pole with 130 mm bottom A/F & 70 mm top A/F made up of 3 mm thick HT sheet along with base plate of size 200 x 200x12mm, M16x600 long 'J' type EN 8 grade foundation bolts., 1000 mm long single/double arm bracket (as per site requirement) with concrete foundation and plinth in hard soil including excation of soil, tamping of concrete grouting with Bakelite sheet and MCB(for mounting inside the base compartment of pole) with all accessories. | — | — | — | 41,550 | |
| — | 4.00 | — | — | ||
| Supply of pole along with brackets suitable for illuminating platform end MS Station Name board on Both faces with OD/Covered LED 4ft Luminaires | — | — | — | 48,000 | |
| — | 4.00 | — | — | ||
| Erection of pole along with brackets suitable for illuminating platform end MS Station Name board on Both faces with OD/Covered LED 4ft Luminaires | — | — | — | 4,000 | |
| — | 6.00 | — | — | ||
| Supply of Digital multi function panel meter Complete with CT's & RS 485 port. | — | — | — | 37,452 | |
| — | 6.00 | — | — | ||
| Erection of Digital multi function panel meter Complete with CT's & RS 485 port. | — | — | — | 4,608 | |
| — | 150.00 | — | — | ||
| Supply of GI flat of size 25mmx3mm | — | — | — | 7,200 | |
| — | 150.00 | — | — | ||
| Supply of GI flat of size 25mmx3mm | — | — | — | 900 | |
| — | 400.00 | — | — | ||
| Supply of GI channel of size 100mm x 50 mm | — | — | — | 19,600 | |
| — | 400.00 | — | — | ||
| Erection of GI channel of size 100mm x 50 mm | — | — | — | 2,800 | |
| — | 18.00 | — | — | ||
| Supply of SMC junction Box complete with Accessories | — | — | — | 10,008 | |
| — | 18.00 | — | — | ||
| Erection of SMC junction Box complete with Accessories | — | — | — | 1,332 | |
| — | 18.00 | — | — | ||
| Supply of Diecast plastic moulded light weight track lead junction box with terminals arrangement etc | — | — | — | 22,086 | |
| — | 18.00 | — | — | ||
| Erection of Diecast plastic moulded light weight track lead junction box with terminals arrangement etc | — | — | — | 900 | |
| — | 6.00 | — | — | ||
| Supply of Thermoplastic junction Box complete with Accessories of size 300x300x182 along with terminals & glands suitable for termination upto 150 sq.mm | — | — | — | 32,454.72 | |
| — | 6.00 | — | — | ||
| Erection of Thermoplastic junction Box complete with Accessories of size 300x300x182 along with terminals & glands suitable for termination upto 150 sq.mm | — | — | — | 3,245.46 | |
| — | 72.00 | — | — | ||
| Foot | Square | — | — | ||
| Design, manufacture & display of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate heet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. | — | — | — | 1,04,173.92 | |
| — | 72.00 | — | — | ||
| Foot | Square | — | — | ||
| Installation, testing & commisioning of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate heet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. | — | — | — | 10,417.68 | |
| — | 48.00 | — | — | ||
| Foot | Square | — | — | ||
| Design, manufacture & supply of wall / hanging / floor mounting type Non illuminated sign/direction boards in Full elliptical /half elliptical/semi elliptical shape and Flat (single side/ double side ). The display sheet shall be of unbreakable 040 translucent polycarbonate heet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination | — | — | — | 34,724.16 | |
| — | 48.00 | — | — | ||
| Foot | Square | — | — | ||
| Erection. testing and commissioning of wall / hanging / floor mounting type Non illuminated sign/direction boards in Full elliptical /half elliptical/semi elliptical shape and Flat (single side/ double side ). The display sheet shall be of unbreakable 040 translucent polycarbonate heet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination | — | — | — | 3,472.32 | |
| — | 288.00 | — | — | ||
| Foot | Square | — | — | ||
| Design, fabrication & supply of LED single side glow sign boards made up of SS sheet IP 50/65 with high quality LEDs, 2 mm thick acrylic sheet topped on SS sheeted frame and is to be provided with computerised Vinyl stckering lettering in Telugu, Hindi, English, with all other connected accessories complete. Board should have uniform glow from end to end irrespctive of size as per specification. | — | — | — | 2,63,488.32 | |
| — | 288.00 | — | — | ||
| Foot | Square | — | — | ||
| Erection. testing and commissioning of LED single side glow sign boards made up of SS sheet IP 50/65 with high quality LEDs, 2 mm thick acrylic sheet topped on SS sheeted frame and is to be provided with computerised Vinyl stckering lettering in Telugu, Hindi, English, with all other connected accessories complete. Board should have uniform glow from end to end irrespctive of size as per specification. | — | — | — | 36,887.04 | |
| — | 200.00 | — | — | ||
| Supply of 20W batten fitting complete set as per specification | — | — | — | 73,800 | |
| — | 200.00 | — | — | ||
| Erection of 20W batten fitting complete set | — | — | — | 8,600 | |
| — | 76.00 | — | — | ||
| Supply of surface mounted LED 40W luminaire batten type fitting complete with necessary mounting accessories, clamps and hardware etc. as per specification | — | — | — | 43,700 | |
| — | 76.00 | — | — | ||
| Erection, connecting, testing and commissioning of surface mounted LED 40W luminaire batten type fitting complete with necessary mounting accessories, clamps and hardware etc. | — | — | — | 6,156 | |
| — | 34.00 | — | — | ||
| Supply of 60W LED street light complete with necessary clamps and hardware etc. as per specification | — | — | — | 92,140 | |
| — | 34.00 | — | — | ||
| Erection, connecting, testing and commissioning of 60W LED street light complete with necessary clamps and hardware etc. | — | — | — | 3,400 | |
| — | 8.00 | — | — | ||
| Supply of 100W LED flood light fixture complete with necessary mounting accessories,clamps and hardware etc as per specification | — | — | — | 30,952 | |
| — | 8.00 | — | — | ||
| Erection, connecting, testing and commissioning of 100W LED flood light fixture complete with necessary mounting accessories,clamps and hardware etc as per specification | — | — | — | 688 | |
| — | 36.00 | — | — | ||
| Supply of LED indoor surface downlighter suitable for general lighting. Luminaire should have pressure die- cast Al housing with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20, IK02 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 2150 lumens and maximum system wattage of 18 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10%. The fixture housing should be available in colors aluminium and grey. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval. Similar to Signify cat ref. no. Sleek Surface Pro SM296C LED20S-6500 PSU WH | — | — | — | 63,720 | |
| — | 36.00 | — | — | ||
| Installation, testing and commissioning of LED indoor surface downlighter suitable for general lighting. Luminaire should have pressure die-cast Al housing with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20, IK02 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 2150 lumens and maximum system wattage of 18 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10%. The fixture housing should be available in colors aluminium and grey. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval. | — | — | — | 6,372 | |
| — | 3.00 | — | — | ||
| Supply of Automatic light controlled nature switch device with infrared space grade sensors and advanced micro controller with suitable power contractor and MCB, enclosed in FRP enclosure for pole mounting confirming to IP: 54 or above suitable for working on 3phase supply and with 5kW power rating. | — | — | — | 47,790 | |
| — | 3.00 | — | — | ||
| Erection of Automatic light controlled nature switch device with infrared space grade sensors and advanced micro controller with suitable power contractor and MCB, enclosed in FRP enclosure for pole mounting confirming to IP: 54 or above suitable for working on 3phase supply and with 5kW power rating. | — | — | — | 4,779 | |
| — | 4.00 | — | — | ||
| Supply of Automatic change over panel complete for color light signaling system having 60 Amps capacity with all connected accessories vig.rotary selector switch, air break contactor, MCCBs, MCBs. LEDs. alarm buzzer, alarm reset micro switch etc.meeting RDSO technical specification No.TI/SPC/PSI/CLS/0020 with amendment No.2 dt.3-4-2006 or latest. | — | — | — | 2,26,248 | |
| — | 4.00 | — | — | ||
| Fixing, connecting, installation, testing and commissioning of Automatic change over panel complete for color light signaling system having 60 Amps capacity with all connected accessories vig.rotary selector switch, air break contactor, MCCBs, MCBs. LEDs. alarm buzzer, alarm reset micro switch etc.meeting RDSO technical specification No.TI/SPC/PSI/CLS/0020 with amendment No.2 dt.3-4-2006 or latest. | — | — | — | 8,000 | |
| — | 4.00 | — | — | ||
| Supply of Automatic Changeover Color Light Signaling Panel Capacity 150A For 25KVA AT as per RDSO Spec no.TI/SPC/PSI/CLS/0020 with A&C slip 1to 4 or latest. | — | — | — | 5,19,200 | |
| — | 4.00 | — | — | ||
| Erection of Automatic Changeover Color Light Signaling Panel Capacity 150A For 25KVA AT as per RDSO Spec no.TI/SPC/PSI/CLS/0020 with A&C slip 1to 4 or latest. | — | — | — | 8,000 | |
| — | 8.00 | — | — | ||
| Supply of 150A CLS junction box as per the drawing No:E.252/Tr.D/C/CLS-JB/2024-01, Dated: 16.07.2024 or latest.Drawing enclosed | — | — | — | 1,52,000 | |
| — | 8.00 | — | — | ||
| Erection, testing and commissioning of 150A CLS junction box as per the drawing No:E.252/Tr.D/C/CLS- JB/2024-01, Dated: 16.07.2024 or latest.Drawing enclosed | — | — | — | 8,960 | |
| — | 8.00 | — | — | ||
| Supply of Weather proof terminal box with Bimetallic bus bar with clampbolts nuts including all accessories etc. (For 25KVA AT) As per DRG No:E.252/ TrD/C/AT-JB/2024-02.Dated:16.07.2024 or latest Drawing enclosed. | — | — | — | 92,000 | |
| — | 8.00 | — | — | ||
| Fixing and connecting and commissioning of Weather proof terminal box with Bimetallic bus bar with clampbolts nuts including all accessories etc. (For 25KVA AT) As per DRG No:E.252/ TrD/C/AT-JB/2024-02.Dated:16.07.2024 or latest Drawing enclosed. | — | — | — | 4,000 | |
| — | 7.00 | — | — | ||
| Supply of 5 star inverter type 1.5 TR capacity split type Air conditioner unit complete | — | — | — | 2,94,000 | |
| — | 7.00 | — | — | ||
| Installation, testing and commissioning of 5 star inverter type 1.5 TR capacity split type Air conditioner unit complete Q | — | — | — | 10,500 | |
| — | 70.00 | — | — | ||
| Supply of copper pipe 1/4" x 1/2" of 20 SWG along with 9 mm thick insulation | — | — | — | 70,210 | |
| — | 70.00 | — | — | ||
| Erection of copper pipe 1/4" x 1/2" of 20 SWG along with 9 mm thick insulation | — | — | — | 3,500 | |
| — | 70.00 | — | — | ||
| Supply of CPVC drain pipe | — | — | — | 9,450 | |
| — | 70.00 | — | — | ||
| Erection of CPVC drain pipe | — | — | — | 700 | |
| — | 3.00 | — | — | ||
| Supply of sand/mud proof ISI marked Submersible pump set of 3.0 HP 23 stage vertical type submersible pump with head at duty point 136 Mtrs. approx. with a discharge of 33 LPM approx. suitable to work on Single phase, having pump maximum outer dia (4") or 100 mm & delivery Size 38mm | — | — | — | 69,579 | |
| — | 3.00 | — | — | ||
| Erection, connecting, testing and commissioning of sand/mud proof ISI marked Submersible pump set of 3.0 HP 23 stage vertical type submersible pump with head at duty point 136 Mtrs. approx. with a discharge of 33 LPM approx. suitable to work on Single phase, having pump maximum outer dia (4") or 100 mm & delivery Size 38mm | — | — | — | 9,741 | |
| — | 3.00 | — | — | ||
| Supply of pump panel suitable for 3HP Single phase Submersible pump comprising of 2 pole contactor, relay, ammeter, voltmeter relay range from 17 to 24 Amps, run capacitor 50+50 mfd, start capacitor 200/250 mfd, complete with all other connected accessories | — | — | — | 13,110 | |
| — | 3.00 | — | — | ||
| Fabrication, erection, testing and commissioning of pump panel suitable for 3HP Single phase Submersible pump comprising of 2 pole contactor, relay, ammeter, voltmeter relay range from 17 to 24 Amps, run capacitor 50+50 mfd, start capacitor 200/250 mfd, complete with all other connected accessories | — | — | — | 600 | |
| — | 4.00 | — | — | ||
| Supply of sand/mud proof 5 Star rated ISI marked Submersible pump set of 5.0 HP 22 stage vertical type submersible pump with head at duty point 150 Mtrs. approx. with a discharge of 33 LPM approx. suitable to work on Three phase 415V AC 50HZ, having pump maximum outer dia (4") or 100 mm & delivery Size 38mm, equivalent to KSB make model No. CORA 7C + UMAI 100 | — | — | — | 1,17,352 | |
| — | 4.00 | — | — | ||
| Erection, connecting, testing and commissioning of sand/mud proof 5 Star rated ISI marked Submersible pump set of 5.0 HP 22 stage vertical type submersible pump with head at duty point 150 Mtrs. approx. with a discharge of 33 LPM approx. suitable to work on Three phase 415V AC 50HZ, having pump maximum outer dia (4") or 100 mm & delivery Size 38mm, | — | — | — | 16,428 | |
| — | 6.00 | — | — | ||
| Supply of 5 HP Starter Control Panel for Submersible pump | — | — | — | 42,000 | |
| — | 6.00 | — | — | ||
| Fabrication, fixing and commissioning of 5 HP Starter Control Panel for Submersible pump | — | — | — | 4,200 | |
| — | 3.00 | — | — | ||
| Supply of Chain link Fencing with MS post of size 5Mtr x 4Mtr, 6 feet height along with angular supports and concrete for foundation | — | — | — | 1,11,819 | |
| — | 3.00 | — | — | ||
| Erection of Chain link Fencing with MS post of size 5Mtr x 4Mtr, 6 feet height along with angular supports and concrete for foundation | — | — | — | 11,181 | |
| — | 1.00 | — | — | ||
| Supply and Erection of 100 KVA DG set with AMF panel | — | — | — | 12,50,000 | |
| — | 4.00 | — | — | ||
| Instrumental topographic survey and submission of report for OH HT power line crossing with complete details like angle of crossing, distance of OH supports, height of lower most conductor with respect to track center, height of OH supports etc. | — | — | — | 47,200 | |
| — | 2.00 | — | — | ||
| Supply of 1KVA online line UPS with IGBT based fully microprocessor controlled with PWM technology, with single phase input, with built in isolation transformer, with inbuilt battery of backup time of 120 Minutes including with all associated connected accesssories as per specification | — | — | — | 1,20,604 | |
| — | 2.00 | — | — | ||
| Erection, connecting, testing and commissioning of 1KVA online line UPS with IGBT based fully microprocessor controlled with PWM technology, with single phase input, with built in isolation transformer, with inbuilt battery of backup time of 120 Minutes including with all associated connected accesssories as per specification | — | — | — | 13,400 | |
| — | 3.00 | — | — | ||
| Supply of Aluminium folding ladder four leg type size 14 feet (01 No),10 feet (01 No.) & 08 feet (01 no.) =1 set. (Warranty Period : Upto 30 months from the date of delivery.) | — | — | — | 1,30,980 | |
| — | 3.00 | — | — | ||
| Supply of Handheld Digital Plus Analog display Insulation tester with peak testing voltage 1000V etc. as per specification | — | — | — | 16,181.34 | |
| — | 3.00 | — | — | ||
| Supply of Power Clamp meter, AC/DC voltage to 1000 V, AC/DC current to 1000A True RMS, Resistance 100 K Ohms etc. as per specification | — | — | — | 29,258.1 | |
| — | 2.00 | — | — | ||
| Supply of Digital Earth Resistance meter with inbuilt rechargeable battery with 3.5 digit LCD display Auto ranging as per specifications attached. | — | — | — | 1,67,572.28 | |
| — | 2.00 | — | — | ||
| Design & Supply of 10 KWp rooftop on-grid solar plant with MPPT technology with Mono PERC Bifacial solar modules of 535wp or above, Module Mounting Structure, Power Conditioning Unit (PCU) consisting of Maximum Power Point Tracker (MPPT),Inverter (10KW output pure sine wave inverter), and Controls and Protections, interconnect cables and switches ,all complete as per the standard specifications as per the direction of site Engineer | — | — | — | 9,73,684 | |
| — | 2.00 | — | — | ||
| Erection, fixing and commissioning of 10 KWp rooftop on-grid solar plant with MPPT technology with Mono PERC Bifacial solar modules of 535wp or above, Module Mounting Structure, Power Conditioning Unit (PCU) consisting of Maximum Power Point Tracker (MPPT),Inverter (10KW output pure sine wave inverter), and Controls and Protections, interconnect cables and switches ,all complete as per the standard specifications as per the direction of site Engineer. | — | — | — | 1,36,316 | |
| — | 400.00 | — | — | ||
| Removing of LT cable and handed over the same to the concerned supervisor at his store (10 to 120 sq.mm) | — | — | — | 20,000 | |
| — | 2.00 | — | — | ||
| Provision of removing unforeseen underground electrical infringements etc. as per the directions of engineer at site. | — | — | — | 1,00,000 | |
| — | 300.00 | — | — | ||
| Removing and Relaying of Exisitng Cables upto 50 Sq.mm | — | — | — | 36,000 | |
| — | 300.00 | — | — | ||
| Removing and Relaying of Exisitng Cables from 70Sq.mm upto 150 Sq.mm | — | — | — | 72,000 | |
| — | 1000.00 | — | — | ||
| — | 500.00 | — | — | ||
| — | 20.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | 20.00 | — | — | ||
| — | 40000.00 | — | — | ||
| — | 20000.00 | — | — | ||
| — | 50.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_1111.pdf correction
ATTACHMENT
Specificationfor10KWpRooftopSolarPlant.pdf
ATTACHMENT
ATCLSJUNCTIONBOXES.pdf
ATTACHMENT
ACSsupto10_1.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
TenderBooklet_PRLILTRR_04-GS-SC-WS-26-27_FF.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_1111.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .