| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.6 LAccepted-AOC 1ST FLOOR MALOO HOUSE PLAIN STREET INFANTRY ROAD BANGALORE KARNATAKA 560001 | BENGALURU URBAN | KARNATAKA | 560001 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹70.0 L+₹2.3 L (3.45%)Rejected-Finance 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹70.6 L+₹3.0 L (4.38%)Rejected-Finance PLOT NO 37 BADANPUR OLD SER NO 34658 NEAR SAI BARAT PALACE PAWAN BHUMI SHAKTI NAGAR JABALPUR MADHYA PRADESH 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Not being Lowest | |
| 4 | L4₹78.9 L+₹11.3 L (16.7%)Rejected-Finance | L4 | Rejected-Finance Not being Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not submitted affidavit of minimum wages , T and P ,Work completion not meeting the NIT Criteria |
Tender Value
₹71.4 L
EMD Value
₹1.4 L
Closing Date
29 May 2020, 6:00 pmClosed
JGM(E-E)-II
AAI, Operational Offices, Chennai Airport, Chennai-600016
FMC of 4 X 100TR AC plant and ACMC for Window, Split, Cassette, Ductable Split Air Conditioner and Water Coolers at Chennai International Airport
2020_AAI_45505_1
AAI/CHE/AMED-IX/2019-20/02
Open Tender
Electrical Works
Item Rate
730 days
Chennai
As per e-NIT
8 documents required · 8 mandatory
₹1,120
Yes
Airports Authority of India
₹1.4 L
Yes
19 Aug 2020
13 Mar 2020
3 Jun 2020
14 Mar 2020
29 May 2020
14 Mar 2020
14 Mar 2020 - 29 May 2020
Amount
FMC for 4X100 TR HVAC system in Admin Block
FMC for 4X100 TR HVAC system in Admin Block to ensure satisfactory operations, day to day maintenance; ensuring serviceability for the details of installations and their associated electrical switch gears; including supervision; recording of all activates of HVAC and complying with Techno commercial specifications of contract, other clauses in the tender document;by providing manpower for 2 shifts on all working days i/c Holidays excepts Sundays.
FMC & CMC for Air conditioners and Water coolers
FMC with All inclusive Annual Comprehensive Maintenance Contract of following type Air- Conditioners & water coolers including all necessary spares, consumables, filters, compressors etc. carrying out preventive maintenance checks daily/ Monthly/Quarterly/ Half yearly /yearly , break down maintenance and Emergency call service etc. to keep the equipment in perfect working condition etc. and complying with Techno commercial specifications of contract, other clauses in the tender document;by providing manpower as required.
Window type Air-conditioners of 1.5/2.0 TR capacity of different make.
i) First Year
ii) Second Year
Split type Air-conditioners of 1.0 TR capacity of different make
i) First Year
ii) Second Year
Split type Air-conditioners of 1.5 capacity of different make
i) First Year
ii) Second Year
Split type Air-conditioners of 2.0 TR capacity of different make
i) First Year
ii) Second Year
High wall Split type Air-conditioners of 3.0 TR capacity of different make
i) First Year
ii) Second Year
Split type Vertical Air-conditioners of 3/4.0 TR capacity of different make
i) First Year
ii) Second Year
3 Phase, 3.0/ 4.0 Ton Cassette type Air- Conditioners units of different make
i) First Year
ii) Second Year
Ductable type Air- Conditioners of 6.0 TR Capacity
a) First Year
b) Second Year
Ductable type Air- Conditioners of 9 TR Capacity
a) First Year
b) Second Year
Ductable type Air- Conditioners of 16.5 TR Capacity
a) First Year
b) Second Year
Comprehensive repair and maintenance of voltage stabilizer upto 5KVA capacity suitable for above split/window A/C units i/c dismantling repairing and refixing etc. as required at site.
a) First Year
b) Second Year
Annual Comprehensive Maintenance Contract of Kelby/conway model storage tank capacity 80 Litres and RO Purification at 50 Litres per hour capacity water cooler including all necessary spares, consumables, filters (Carbon & Spun);Taps and compressor etc (except membrane) to keep the equipment in perfect working condition etc., as required.
a) First Year
b) Second Year
Annual Comprehensive Maintenance Contract of Kelby Brook brand 125 NHC model for normal, hot & cold water cooler fitted with water purification of UV protection including all necessary spares consumables, filters (Carbon & Spun);Taps and compressor etc to keep the equipment in perfect working condition etc., as required.
a) First Year
b) Second Year
Annual Comprehensive Maintenance Contract of Kelby make 125 litres/ hour capacity / Voltas make Normal Water Cooler fitted with model for normal, hot & cold water cooler including all necessary spares, consumables, filters (Carbon & Spun);Taps and compressor etc to keep the equipment in perfect working condition etc., as required.
a) First Year
b) Second Year
Annual Comprehensive Maintenance Contract of Zero B Eco chill water cooler 40-80-40 with inbuilt RO purification system with HRR & ESS Technology having two tap for cold and normal water with stainless steel body including all necessary spares, consumables, filters and RO membrane,Taps and compressor etc to keep the equipment in perfect working condition etc., as required.
a) First Year
b) Second Year
MISCELLANEOUS AC & WATER COOLER WORKS
Supply of Membrane suitable for Kelby/ Conway make RO type water coolers etc., complete as required.
Installation, testing and commissioning of following type of AC units of any reputed make in the existing opening i/c fitting of indoor and outdoor unit at their respective locations, drilling holes in the wall using suitable hardwares, ceiling supporting arrangement, leak testing of entire system, charging refrigerant gas in the unit , making good the surface as per requirement of the site, providing of wooden frame ply board and necessary painting with matching colour etc.(if required)complete as required at site.
Window AC upto 1.5/2 TR
Split AC upto 1.5/2 TR
Cassette AC upto 1.5/2/3/4 TR
Tower AC upto 2/3/4 TR
Dismantling of following type Air- Conditioners including In door & Out door units and all accessories etc, and shifting the same to AAI store complete as required.
Window AC upto 1.5/2 TR
Split AC upto 1.5/2 TR
Cassette AC upto 1.5/2/3/4 TR
Tower AC upto 2/3/4 TR
Supply of cordless remote different make 1.5/2.0 TR/3.0TR split type/window type/tower type/cassette A/C units as required.
Supply & installation of additional Refrigerant copper piping of suitable size b/w indoor and outdoor units, including protective external covering with 10mm thick closed cell Polyethylene foam insulation or nitrile rubber or PUF with all necessary supports,fittings,brazing, wrapping with plaster and leak proof arrangements as required and recommended by the OEM. Refrigerant copper piping: For 1TR: Suction Tube 1/2" & Liquid Tube 1/4" For 1.5TR: Suction Tube 1/2" & Liquid Tube 1/4" For 2TR: Suction Tube 5/8" & Liquid Tube 3/8" For 3TR: Suction Tube 3/4" & Liquid Tube 1/2" For 4TR: Suction Tube 3/4" & Liquid Tube 1/2"
SITC of Suction Tube & Liquid Tube for 1TR & 1.5 TR AC
SITC of Suction Tube & Liquid Tube for 2TR AC
SITC of Suction Tube & Liquid Tube for 3TR & 4 TR AC
Supplying, of following thickness closed cell elastrometric nitrile rubber of class ‘O’ as per specifications and as required complete in all respect.
9 mm thick , 5/8' dia
9 mm thick ,1/2' dia
Supply of standard outdoor wall bracket with vibration pad of suitable size for different capacity of AC's complete as required at site.
Split AC upto 1.5/2 TR (Outoor)
Supply of suitable size (not less than 25 mm) drain pipe medium duty with Insulation complete as required and as per satisfaction of EIC
Supply & Fixing of condenser copper coils of following capacity, dismantling of existing old Aluminium coils and shifted to AAI Store etc., complete as req.
Supply & fixing of 13mm thick class O closed cell Aflex GC cloth faced nitrile rubber dia 25mm with suitable rubber adhesive, finally finished coating poly shield.Inclusive of scaffolding and transportation charges.
Supply, installation, testing and commissioning of following nominal size of chilled water piping of MS "C" class Heavy duty pipes with 50mm EPS insulation provided complete with all fittings and accessories like Bends, Tees, reducers, exp. Joints supports, clamps, etc complete as required and as per specification (For pipes of dia. up to 200 mm IS 1239 (1) & above, IS 3589)
150 mm dia
100 mm dia
Supply and fixing of 50mm EPS insulation for existing chilled water piping of MS "C" class Heavy duty pipe, etc complete as required and as per specification.
150 mm dia
100 mm dia
SNOWMEX ENGINEERS LIMITED
Zamzam Refrigeration and airconditioning
M/s Cooltec
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .