| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-Finance | ₹16.9 L | L1 | Accepted-Finance Being lowest bidder |
| 2 | L2₹16.9 L+₹2,230 (0.13%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | ₹16.9 L+₹2,230 (0.13%) | L2 | Rejected-Finance Not being lowest bidder |
| 3 | L3₹17.8 L+₹95,165 (5.63%)Rejected-Finance | ₹17.8 L+₹95,165 (5.63%) | L3 | Rejected-Finance Not being lowest bidder |
| 4 | L4₹18.7 L+₹1.8 L (10.7%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | ₹18.7 L+₹1.8 L (10.7%) | L4 | Rejected-Finance Not being lowest bidder |
| 5 | L5₹18.9 L+₹2.0 L (11.7%)Rejected-Finance | ₹18.9 L+₹2.0 L (11.7%) | L5 | Rejected-Finance Not being lowest bidder |
| Sl No | Description | Qty | Unit | L-7 Primewave Communications L9 | AIRDOT ENGINEERING L5 | Mahindra Electric Stores L3 | NEELESH ENGINEERS L8 | Chaulya Enterprises L2 | R R Associates L7 | M R ENTERPRISES L1 | Azurite Engineering L6 | M/S ROHIT ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation testing and commisioning of inverter based wall mounted typed split Air Conditionar of capacity 1.5 Ton, 5 Star rating (Copper coil), electric driven single phase, 240 volts, 50 Hz supply, complete with indoor and outdoor unit, remote control, including all accessories like brackets, MS stand made out from suitable size of MS angle iron, copper tubbing nitrile rubber insulation including brazing, suitable size of PVC drain pipe, PVC insulation multistranded copper cable of suitable size from indoor unit to outdoor unit, and making good distrurbed surface to mach with the existing surface complete all as per specified and directed
(Make: HITACHI/CARRIER/VOLTAS/ BLUE STAR 'O' general)
Note:
1. All cooling and conditioning coil should be copper material.
2. Mounting braket for outdoor unit is included in Quotated rates | 6 | Each | 68,000 ₹4,08,000 | 54,300 ₹3,25,800 | 52,000 ₹3,12,000 | 63,000 ₹3,78,000 | 46,500 ₹2,79,000 Lowest | 48,000 ₹2,88,000 | 47,100 ₹2,82,600 | 56,000 ₹3,36,000 | 65,000 ₹3,90,000 |
| 2.00 | Supply, installation testing and commisioning of inverter based wall mounted typed split Air Conditionar of capacity 02 Ton, 5 Star rating (Copper coil) three star rating, electric driven single phase, 240 volts, 50 Hz supply, complete with indoor and outdoor unit, remote control, including all accessories like brakets, MS stand made out from suitable size of MS angle iron, copper tubbing nitrile rubber insulation including brazing, suitable size of PVC drain pipe, PVC insulation multistranded copper cable of suitable size from indoor unit to outdoor unit, and making good distrurbed surface to mach with the existing surface complete all as per specified and directed (Make: HITACHI/CARRIER/VOLTAS/ BLUE STAR 'O' general)
Note: 1. All cooling and conditioning coil should be copper material.
2. Mounting braket for outdoor unit is included in Quotated rates | 10 | Each | 77,000 ₹7,70,000 | 61,800 ₹6,18,000 | 68,000 ₹6,80,000 | 72,000 ₹7,20,000 | 68,000 ₹6,80,000 | 65,000 ₹6,50,000 | 60,900 ₹6,09,000 Lowest | 75,000 ₹7,50,000 | 65,000 ₹6,50,000 |
| 3.00 | Supply, installation, testing and commissioning of Walk in chiller temprerature range + 2 Degree Celsius to + 8 Degree Celsius of size 96''x 96''x 96'' consisting of wall and ceiling PUFF panels of 60mm thick, Material PPGI/ PPGI with density 60 KG/M3 + -3, Flooring 60mm thick P P outer -18 GGI + Anti skid, Door : PUF-Flush in type swing door with 34" x 78" clear opening with accessories: Anti-condensation door Heater, Pad lock system, Posi seal closure, Human Safety release knob, Evaporator Unit & condenser unit: BLUE STAR LIMITED/ Carrier or equivalent make Split type - Air - cooled, 230/1/50 Regrigration Capacity offiered : 10,000 BTU/Hr x 2 Nos @ 4 Degree celsius room tempreture and 35 Degree celsius ambient split type - Air - cooled refigerant : R404A, 1 Working + 1 Standby, Fully SS indoor body, Hooter for rise in tempreture indication, lights inside the cold room 2 Nos, with necessary civil work required at site, stand for outdoor units complete as all specified and directed. | 1 | Each | 8,45,000 ₹8,45,000 | 8,17,000 ₹8,17,000 | 6,00,000 ₹6,00,000 Lowest | 8,10,000 ₹8,10,000 | 6,25,000 ₹6,25,000 | 9,95,000 ₹9,95,000 | 7,05,000 ₹7,05,000 | 6,80,000 ₹6,80,000 | 6,80,000 ₹6,80,000 |
| 4.00 | Material and Labour for submain wiring in PVC casing & caping with two runs of 4 sq mm and one runs of 4 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS 694) drawn through and including 25 mm dia PVC rigid conduit heavy grade ISI marked (IS 9537 Part III) includung accessories such as bends, supports etc Note: Two runs of 4 sq mm and one runs of 4 sqmm cable along with conduit shall be measured as one length complete all as per specified and directed. | 369 | RM | 300 ₹1,10,700 | 241 ₹88,929 | 425 ₹1,56,825 | 405 ₹1,49,445 | 210 ₹77,490 | 200 ₹73,800 | 180 ₹66,420 Lowest | 400 ₹1,47,600 | 340 ₹1,25,460 |
| 5.00 | Supply and fix in repair sheet metal enclosures with socket plug top and MCB 20 amp double pole factory made duly painted 240 ,AC concealed in wall suitable for fixing gyser /AC complete all as specified and directed.
Make:L & T/legrand/Standard | 16 | Each | 1,500 ₹24,000 | 1,850 ₹29,600 | 1,500 ₹24,000 | 1,530 ₹24,480 | 1,250 ₹20,000 | 1,000 ₹16,000 | 999 ₹15,984 | 800 ₹12,800 Lowest | 800 ₹12,800 Lowest |
| 6.00 | Supply and fix Heavy duty rust proof Mounting Bracket for Air conditioner outdoor unit which supports upto 150kg weight Air Conditioner with Necessary Wall Fittings complete all as specified and directed. | 16 | Pair of 2 | 1,200 ₹19,200 | 540 ₹8,640 Lowest | 750 ₹12,000 | 540 ₹8,640 Lowest | 650 ₹10,400 | 1,000 ₹16,000 | 666 ₹10,656 | 1,400 ₹22,400 | 800 ₹12,800 |
Tender Value
₹21.9 L
EMD Value
₹43,720
Closing Date
3 Aug 2026, 6:55 pmClosed
GE MH AND RH KHADKI
Garrison Engineer (MH and RH) Range Hills Road Khadki, Pune 411003
PROVN OF COOLING APPLIANCES WITH WALK-IN COOLER ALONG WITH NECESSARY ELECTRIFICATION WORK FOR MEDICAL STORE IN MILITARY HOSPITAL UNDER GE (MH AND RH) KHADKI)
2026_MES_776793_1
8887/E8
Open Tender
Civil Works
Item Rate
GE MH AND RH KHADKI
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹43,720
9 Sept 2026
6 Jul 2026
5 Aug 2026
6 Jul 2026
3 Aug 2026
20 Jul 2026
6 Jul 2026 - 27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation testing and commisioning of inverter based wall mounted typed split Air Conditionar of capacity 1.5 Ton, 5 Star rating (Copper coil), electric driven single phase, 240 volts, 50 Hz supply, complete with indoor and outdoor unit, remote control, including all accessories like brackets, MS stand made out from suitable size of MS angle iron, copper tubbing nitrile rubber insulation including brazing, suitable size of PVC drain pipe, PVC insulation multistranded copper cable of suitable size from indoor unit to outdoor unit, and making good distrurbed surface to mach with the existing surface complete all as per specified and directed
(Make: HITACHI/CARRIER/VOLTAS/ BLUE STAR 'O' general)
Note:
1. All cooling and conditioning coil should be copper material.
2. Mounting braket for outdoor unit is included in Quotated rates | 6 | Each | - | - |
| 2 | Supply, installation testing and commisioning of inverter based wall mounted typed split Air Conditionar of capacity 02 Ton, 5 Star rating (Copper coil) three star rating, electric driven single phase, 240 volts, 50 Hz supply, complete with indoor and outdoor unit, remote control, including all accessories like brakets, MS stand made out from suitable size of MS angle iron, copper tubbing nitrile rubber insulation including brazing, suitable size of PVC drain pipe, PVC insulation multistranded copper cable of suitable size from indoor unit to outdoor unit, and making good distrurbed surface to mach with the existing surface complete all as per specified and directed (Make: HITACHI/CARRIER/VOLTAS/ BLUE STAR 'O' general)
Note: 1. All cooling and conditioning coil should be copper material.
2. Mounting braket for outdoor unit is included in Quotated rates | 10 | Each | - | - |
| 3 | Supply, installation, testing and commissioning of Walk in chiller temprerature range + 2 Degree Celsius to + 8 Degree Celsius of size 96''x 96''x 96'' consisting of wall and ceiling PUFF panels of 60mm thick, Material PPGI/ PPGI with density 60 KG/M3 + -3, Flooring 60mm thick P P outer -18 GGI + Anti skid, Door : PUF-Flush in type swing door with 34" x 78" clear opening with accessories: Anti-condensation door Heater, Pad lock system, Posi seal closure, Human Safety release knob, Evaporator Unit & condenser unit: BLUE STAR LIMITED/ Carrier or equivalent make Split type - Air - cooled, 230/1/50 Regrigration Capacity offiered : 10,000 BTU/Hr x 2 Nos @ 4 Degree celsius room tempreture and 35 Degree celsius ambient split type - Air - cooled refigerant : R404A, 1 Working + 1 Standby, Fully SS indoor body, Hooter for rise in tempreture indication, lights inside the cold room 2 Nos, with necessary civil work required at site, stand for outdoor units complete as all specified and directed. | 1 | Each | - | - |
| 4 | Material and Labour for submain wiring in PVC casing & caping with two runs of 4 sq mm and one runs of 4 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS 694) drawn through and including 25 mm dia PVC rigid conduit heavy grade ISI marked (IS 9537 Part III) includung accessories such as bends, supports etc Note: Two runs of 4 sq mm and one runs of 4 sqmm cable along with conduit shall be measured as one length complete all as per specified and directed. | 369 | RM | - | - |
| 5 | Supply and fix in repair sheet metal enclosures with socket plug top and MCB 20 amp double pole factory made duly painted 240 ,AC concealed in wall suitable for fixing gyser /AC complete all as specified and directed.
Make:L & T/legrand/Standard | 16 | Each | - | - |
| 6 | Supply and fix Heavy duty rust proof Mounting Bracket for Air conditioner outdoor unit which supports upto 150kg weight Air Conditioner with Necessary Wall Fittings complete all as specified and directed. | 16 | Pair of 2 | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.61 MB
BOQ_869897.xls
BOQ • 0.27 MB
Tender8887R.pdf
Tender Documents • 14.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .