Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | ₹9.2 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹11.0 L+₹1.8 L (19.0%)Rejected-Finance | ₹11.0 L+₹1.8 L (19.0%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹11.0 L+₹1.8 L (19.5%)Rejected-Finance | ₹11.0 L+₹1.8 L (19.5%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹11.1 L+₹1.9 L (20.5%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | ₹11.1 L+₹1.9 L (20.5%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹11.1 L+₹1.9 L (20.9%)Rejected-Finance | ₹11.1 L+₹1.9 L (20.9%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹8.8 L
EMD Value
₹17,540
Closing Date
6 Apr 2022, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim 737102
Special repair to Bldg No T 353 living shelter and certain minor works under GE Gangtok
2022_MES_510002_2
8018AE8
Open Tender
Miscellaneous Works
Item Rate
182 days
Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹17,540
Yes
9 May 2022
25 Mar 2022
8 Apr 2022
25 Mar 2022
6 Apr 2022
25 Mar 2022
Amount
SCHEDULE 'A' (B/R WORKS) Dismantling old PGI/CGI/Fiber sheeting any gauge, thickness including Nainital. Sikkim or similar pattern roof/facia including ridge etc and keeping serviceable sheets in safe custody for re-use complete all as specified and as directed.
Dismantling of wall and ceiling board (fibre pulp, insulation etc.,) /AC sheets and plywood any thickness and cover fillets and removal of dismantled materials/rubbish from site complete all as specified and directed.
Taking down cement plaster/terrazo cast in situ of any description on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Demolition of brick work or stone / boulder masonary or precast concrete block walling , built in cement mortar including all quoins, arches, pillars, etc but exclusing ashlar facings, dressed stoneswork and precast concrete articles complete all as specified and as direcetd.
Demolition of concrete in ground floor and paving n.exc 15cm thick (un-reinforced) complete all as specified and as directed.
Taking up or down 15mm steel tubing and connection including cleaning for re-fixing or removing from site and S&F of 50mm bore GI pipe with all fittings fixed complete to wall, ceiling or laid in floor.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area n.exc 1.5 sqm all as specified and as directed.
Dismantling of timber in scantling 40 sqcm and over in section in any position in unframed work all as specified.
Demolition of reinforced cement concrete in any description and in any position complete all as specified and as directed. (Reinforcement cut as required to facilitate demolition).
Dismantling wrought iron or mild steel work of any description not otherwise provided for grills, rails etc. complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & as directed.
Material and labour for Lacquer coated Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement & pigment, set, jointed and pointed in neat cement slurry in floors cement laid over and including screed bed/ bedding layer of 15mm thick in cement mortar (1:6) complete all as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair complete all as specified and as directed.
M&L for rendering 20mm thick in cement mortar (1:4) in two layer of 10mm thick each with using WPC shall be mixed with cement mortar in finishing outer layer only as per manufacturer's instruction, on other than fair face of brick/stone masonry (external surfaces) finished surface fair and even without using extra cement complete all as specified and as directed. Note : (WPC shall be measured and paid separately as supply only)
Rough excavation in hard/dense soil not exc. 1.5 metre in depth and getting out complete all as specified and as directed by the Engr-in-Charge.
Returning, filling in soil/back filling of retaining walls using approved earth obtained from excavation including watering, well ramming etc complete all as specified and as directed.
Removing excavated materials(soil) to distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2(using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as dirc
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4) including laying PC pipe in weep holes complete all as specified and as directed.
M&L RCC M-25 (design mix) using 20mm graded stone aggr as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M&L for mild steel TMT bars, 10mm dia and over cut to length, bent to shape required including cranking, bending spirally, hooping for columns, hookings ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for labour for Mild steel TMT bars 5mm dia and over upto including 10mm dia as in stirrups, spacers and binders cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for pre cast cement concrete block masonry with solid blocks exceeding 10 cm in width and settting in cement mortar 1:6 type C1, (1:3:6) (using 20 mm graded stone aggregate) as per IS-383 complete all as specified and as directed.
Material & labour for non skid coloured ceramic tiles of 7 to 8mm thick ( Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.36 Sqm as in floors etc conforming to IS-13712, grade B-II-(a) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including cement screed bed/bedding layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.
S&F for mild steel tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St-240 including one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication and fixing complete all as specified and as directed.
S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
M&L for 35mm thick 2nd class HW plain, framed, paneled shutters (two panel) with lock rail and panel of 9mm thick BWR commerical ply or 12mm veneered particle board with commercial face veneering on both faces. The size of rail & site as per IS : 1003 (Part-I), Kiln, seasoned & chemically pressure, treated complete all as specified and as directed.
S&F of factory made steel windows with side hung shutters openable type including friction/box type hinges steel handle and peg stay complete with glazing bars fixed to existiog opening and making good to match as per existing surfaces including taking out old/unserviceable steel windows complete all as specified and as directed.
S&F in repair 4.0 mm thick tinted sheet glass, ordinary quality and glazing without putty in square in exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F 150mm long aluminum anodised tower bolts of extruded section and fixed complete all as specified and directed.
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed.
Supply & fix Aluminium handles, 150 mm size, cast type, anodised complete all as specified and as directed.
S&F of 100mm size mild steel butt hinges medium weight complete all as specified and as directed.
S&F floor door stopper with overall length of cover plate 150mm of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in door complete all as specified and as directed.
M&L for preparation of old/new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer applied over 3mm thick super fine Birla or altek wall care putty finish including complete removal of existing treatment complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistance primer on new surfaces of walls complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces exc 10cm width or girth over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed.
Supply and fixing 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts as in walls cladding etc, (Class VIII) all as specified and directed.
Supply and fixing 0.63mm thick plain, galvanised, mild steel sheeting, with 275 grams per Sqm Zinc coating as in ridges, hips, valley gutters, drip & straight flashing etc complete all as specfied and as directed.
All as per item No. 42 here-in-before but except sheeting.
Material and labour 6 mm thick plywood, 5 ply, grade BWR type BB fixed with nails to timber frame work in Wall/ Ceiling complete all as specified and as directed.
Material and labour for 2nd class hard wood fillets, square, rectangular and triangular in section, wrought, secured with nails,sectional area exe 3 Sqcm but n.exc 6 Sqcm in section complete all as specified and as directed.
S&F for PVC (SWR) (Bore of pipe 110mm) pipes single socketed, in any length with rubber ring joints fixed to walls with necessary clamps, bolts etc complete all as directed by Engr-in-Charge.
S&F for PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters etc (Bore of pipe 110mm) complete all as directed by Engr-in-Charge
S&F in repair aluminium power coated fancy curtain rails plain or colour 20 to 25mm dia as approved with teak wood finishing brackets and knobs complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in surface channels and drain including forming fair finish the surface even & smooth without using extra cement etc complete all as specified and as directed.
M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form, moulds, mitred/stopped ends complete all as specified and as directed.
M&L for 15mm dia steel tubing medium grade galvanised with allfitting fixed complete to walls and ceiling or floor complete all as specified and as directed
S&F of factory made steel ventilator with top hung shutters openable type including friction/projected type hinges steel handle and peg stay complete without glazing bars fixed to existing opening and making to match as per existing surfaces complete all as specified and as directed including taking down old unserviceable steel ventilators.
Material & labour for preparation of old painted surfaces of wood & wood based materials over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed by the Engr-in-Charge.
M&L for preparation of new or previously untreated wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L for 2nd class hard wood in scantling fixed in clean sawn complete all as specified and as directed.
All as per item No. 55 above but except timber scantling.
M&L for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded stone aggregate ) as in plinth protection; path / hardstanding etc laid in bays / panels not exc.2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified and as directed.
SCHEDULE 'A' (E/M WORKS) Taking down copper/aluminium point wiring (light, fan, socket or power) complete, inlcuding fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Taking down carefully by unscrewing from boards/outlet boxes, DBs, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc complete all as specified and as directed.
Taking down MCB of any type or rating and keeping aside complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC (FRLS) insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor in including PVC heavy grade rigid non metallic 25mm PVC casing caping (double Lock) including PVC polycarbonate/PVC/recatangular block/box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nomnal cross sectionl area PVC (FRLS) insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DBs or common earth dolly complete all as specified and directed for the following .Make of cable-Havells/Finolex/plaza, Make of casing caping- Prestoplast/Plaza/Modi.
All as per item No. 61 here-in-above but with 1.5 Sqmm copper conductor with 1.5 Sqmm earth stranded wire for 5 Amps power point in independent board.
All as per item No. 61 here-in-above but with 2.5 Sqmm copper conductor with 2.5 Sqmm earth stranded wire for 16 Amps power point in independent board.
S&F decorative LED tube light fitting 1x18 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F lamp holder angular/straight insulated body, with back plate suitable for batten fittings, white/ivory finish complete all as directed. Make : Anchor Product Code No 39527 or equivalent of approved make
S&F switch piano flush button,single pole,one way(ISI marked), 6 amps complete all as specified and as directed. Make : Anchor product code No. 50053 or equivalent of approved make
S&F switch socket combination, 2 and 3 pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as directed including taking down old one. Make : Anchor Product Code No 4056/50483 or equivalent of approved make
S&F switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose , flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete complete all as directed including taking down old one. Make : Anchor Cat No 38808/50665 or equivalent of approved make
S&F ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed Make : Anchor Product Code No 39040 or equivalent of approved make
S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed.vells/ABB/Legrand) (Make : L&T cat No DBSPN008DD or equivalent of Havells/ABB/Legrand
S&F in repairs MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. (Make : L&T cat No BB10060C to BB10320C or equivalent of approved make
S&F in repairs MCB single pole & neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. (Make : L&T cat No BB20400C to BB20630C or equivalent of approved make
Supply, laying, jointing & testing 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured LT electric power cables, heavy duty with aluminium conductor of cross sectional area 16 Sqmm 2 core with all fixing & connecting accessories as in service connection complete all as specified and as directed including taking down old unserviceable one. Note : The rate quoted by the bidder shall be deemed to be inclusive of cost of aluminium thimbels/lugs of suitable size.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected with galvanised iron/steel earth wire of 4mm dia by means of bolts, nuts, check nuts and washers made outof galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore and connected to VTPN DB/SPN DB including neccessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2;4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS hook 6mm dia MS bars etc complete all as specified and as directed including testing on completion.
S&F electrical water heater storage with copper inner tank and heating element, capacity 2 KW, 25 Ltr BEE 5 Star rated complete with accesories such as safety valve thermostate, NRV, connection piece etc. Make : Havells, Cat-Monza DX GHWAMGTWHO025 or equivalent approved make.
S&F CP for basin/wall mixer for hot and cold water mixing, ISI marked with iron wheel head screwed both ends for GI pipe complete all as specified and as directed.
S & F gun metal gate valves of size 15mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fixing galvanised steel water tubing 15mm bore, medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as directed.
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm, complete all as specified and as directed.
Supply and fix stop connection 15mm size with PTMT nut of length 750mm, complete all as specified and as directed.
S&F exhaust fan 250mm sweep, 1400 RPM, 240 Volt, AC 50 Hz, PVC body, including louvers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement mortar complete all as specified and as directed. (Make : Havell Ventil Air-DX White or equivalent approved).
Cutting brick/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement mortar complete all as specified and as directed.
Supply and installation of induction motor 30 HP, 3 phase, 415 V to match with pumpset all as specified in Sl item No. 84 here-in-after.
Supply and installation of pump set, centrifugal electric driven 30 HP to match with working characteristics with motor as specified in item No. 83 here-in-above.
Supply and installation of Submersible pump with high discharge rate, electric driven 415 V, TP suitable for 200/150mm dia bore well 20 HP inclusive of 100 metre long submersible cable and starter complete all as specified and as directed.
M&L for copper strip 25x3.15mm as roof conductors and down conductors buried in ground/fixed on wall with epoxy based insulator and screws, bolts, nuts and lead washers complete all as specified and as directed. (Note Epoxy insulators will be measured and paid separately).
S&F to existing pipeline HDPE pipe of size 50 mm bore OD, PE-100, PN-6, mild steel with metal flanges on both ends conforming to IS 4984-2016 with latest amendments complete with gasket, bolt, nuts and washers to existing pipeline on ground/floor/trench, all as specified and as directed. Make : Make : Supreme/Hallmark Aqua equipment Pvt.Ltd./Premier Irrigation ADRITEC Pvt. Ltd. or equivalent approved.
M&L for Air termination, single pointed copper rod 12mm dia and 300mm long complete all as specified and as directed.
M&L for Epoxy insulator with hole for suitable screw fitting and all screw and nut accessories for fixing strip complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws in and including box duly powder coated and backed made of GI sheet 2mm thick of size 200x150x100mm and screwed to wall complete all as specified and as directed.
M&L for Earthing complete in repairs with Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3043.The outer and inner pipe should be 48.3mm &26.4mm 2mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed inthe pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity ,The job includes digging the pits and refilling the same by BARONS Electrodite OR Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS Certification from NABL accredited lab. The earth pit should be provided with a FRP OR EPCC earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH ie BLACK COTTON OR MOISTUROUS NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 TO 4 bags ELECTRODITE 0R 2-4 BAGS CONDUCTILITE BFC FOR INSTALLATION OF EARTH ELECTRODE. The electrode should be of galvinised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm, 7.5 m. including excavation earthwork etc connected to electrical eqpts/panels and testing on completion all as specified and directed by Engineer in charge.
M/S ANIL KUMAR THAKUR
DHARMINDER SINGH
M/S S. S CHETTRI AND SONS
RAAJ BANGAR
MAHENDRA KHAWAS
KARMA SHERPA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .