Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.1 CrAccepted-AOC 30 1 BHAVANI MAIN ROAD VEERAPANCHATRAM ERODE 638004 | ERODE | TAMIL NADU | 638004 | ₹2.1 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹2.3 Cr+₹14.8 L (6.90%)Rejected-Finance | ₹2.3 Cr+₹14.8 L (6.90%) | 2 | Rejected-Finance L2 |
| 3 | 3₹2.5 Cr+₹35.2 L (16.4%)Rejected-Finance | ₹2.5 Cr+₹35.2 L (16.4%) | 3 | Rejected-Finance L3 |
| 4 | 4₹2.6 Cr+₹46.0 L (21.4%)Rejected-Finance NO 39 3RD KOVALAN STREET TEACHERS COLONY ERODE 638011 | ERODE | TAMIL NADU | 638011 | ₹2.6 Cr+₹46.0 L (21.4%) | 4 | Rejected-Finance L4 |
Tender Value
₹2.4 Cr
EMD Value
₹2.4 L
Closing Date
21 Jul 2022, 3:00 pmClosed
Deputy General Manager(Civil)i/c
TCMPF Ltd, Aavin illam, No.3A Pasumpon muthuramalinganar salai,Nandanam, Chennai-35.
Construction of Finished Product Godown and Raw Material Godown at existing Cattle Feed Plant, Erode.
2022_TCMPF_237490_1
5795/Engg.3/2022
Open Tender
Civil Works
Lump-sum
180 days
Erode
Refer Tender document
8 documents required · 8 mandatory
₹0
₹2.4 L
Yes
TCMPF Limited ,Aavin illam,Nandanam-35
7 Oct 2022
27 Jun 2022
22 Jul 2022
27 Jun 2022
21 Jul 2022
27 Jun 2022
27 Jun 2022 - 21 Jul 2022
6 Jul 2022
Amount
Earth work narrow excavation for foundation in all soils and sub soils and to full depth as may be directed except hard rock requiring blasting inclusive of shoring, shuttering and baling out water where ever necessary, refilling the sides of foundations with excabvated earth in layers of not more than 15cm thk watered, well rammed , consolidated and depositing the surplus earth on bank with initial lead of 10m and initial lift of 2m, clearing and leveling the site etc., complete as directed by the federation officers and as per standard specifications. From 0.0m to 2.00 m Depth
Dismantling of soft designated rocks and medium rocks by using chemical/compresser and keeping away the depreise from the site etc.., rate including all tools and plants, conveyance, scaffolding and safety measures etc.., complete as directed by the departmental officers.
Plain Cement Concrete 1:5:10 using 40 mm size HBG stones for foundation including de-watering if found necessary and laid in layers of not more than 15 cm thick for flooring including rendering the top surface rough to take floor finish including side shuttering if required and compaction ,curing etc., complete as directed by the Federation officers and as per the technical Specifications
Brick work in Cement Mortar 1:5 (one part cement and five parts sand) using best quality II class Ground moulded chamber burnt bricks of size 9" x 4-1/2" x 3" to line, level and to plumb on one face including necessary scaffolding, racking out joints, curing etc., complete as directed by the departmental officers and as per standard specification. - For Foundation and Basement
Above basement up to 4.50m ht
Up to 4.50m to 9.00m ht.
Reinforced Cement Concrete 1:1-1/2:3 (One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - Upto basement
Above basement - upto 4.50m ht
up to 4.50m to 9.00m ht
Supplying , erection and steel centering for all RCC works using M.S Sheet, M.S. angles casurina props C.W.joints for all type of RCC works (ie) beams, roof slab, lintel, column footing, column & roof beam etc., including necessary supports with all cross bracing, filling the slits and holes the reprieved materials should be taken by the contractor and side shuttering etc., complete as directed by the departmental officers. Up to basement - Column surface
Above basement 0.00to 3.30m - Column surface
Above basement 3.30to 4.30m - Column surface
Above basement 4.30to 5.30m - Column surface
Above basement 5.30 to 6.30m - Column surface
Above basement 6.30to 7.30m - Column surface
Up to basement - Plain surface
Above basement 0.00to 3.30m - Plain surface
Above basement 4.30to 5.30m - Plain surface
Supply, fabricating and placing in position of reinforcement grills for all RCC works including cost of steel rods, binding wires, labour for bending, cutting and tying etc., complete as as directed by the federation officers and as per standard specifications.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five M sand), 12mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five M sand), 20 mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing gear operated type rolling shutter with necessary cutting, welding and fixing with bolt and nuts etc.,complete complying with standard specification and as directed by the departmental officers.
Supply and fixing steel ventilator with necessary cutting, welding and fixing with bolt and nuts etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing M.S.Angles and I-beams for steel roof truss, Purlin, etc., with necessary cutting, welding and fixing with bolt and nuts etc.,complete complying with standard specification and as directed by the departmental officers.
Supplying and filling with conveyed Gravel for foundation and basement to required thickness and in layers on not more than 30 cm thick, watered ,well rammed and consolidated etc., complete as directed by the Federation officers and as per the technical Specifications.
Supply and filling with M sand for foundation and basement to required thickness and in layers of not more than 15 cm thick, watered, well rammed and consolidated etc., complete as directed by the Federation Officers and as per standard specifications.
Supply and fixing of 6mm thick plain A.C roofing Sheets for roofing including boltls , nuts and washers etc., complete as directed by the Federation Officers and as per standard specifications.
Supplying and fixing in position of Powder coated MS roofing sheet of 0.47mm thick with necessary bolts, nuts and washers, metal screws etc. complete with standard specification and as directed by the departmental officers.
Supply and fixing of 600mm dia aluminium roof turbo ventilator etc., complete as directed by the Federation Officers and as per standard specifications.
Supply and fixing of light roofing Sheets for roofing including boltls , nuts and washers etc., complete as directed by the Federation Officers and as per standard specifications.
Supplying and Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint (interior) of first class quality and of approved color over one coat of priming coat including priming coat and also make good of the surface with sand paper, putty, scaffolding etc., complete as directed by the departmental officers
Supplying and painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint (exterior) of first class quality and of approved color over one coat of priming coat including priming coat and also make good of the surface with sand paper, putty, scaffolding etc., complete as directed by the departmental officers.
Painting two coats of new iron work using ready mixed enamel paint of approved quality and colour over a priming coat etc. complete as directed by the departmental officers. (such as steel door , grill, M.S Channel & angle etc.,)
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (4 points per coil)
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and concealed with 3mm thick hylem sheet
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet
Supply and fixing of WT bulk head fitting with guard suitable for 11W CFL lamp with CFL
Supply and fixing of electrical lamps, fittings and connected accessories etc., 18W 4Feet LED fitting with LED
Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work
Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.
CONTINENTAL CONSTRUCTION COMPANY
RG ASSOCIATES
KONGU CONSTRUCTION AND CONTRACTORS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .