Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | Admitted-Finance |
| 2 | Admitted-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | Admitted-Finance |
| 3 | Admitted-Finance NO 33 JEENIS ROAD SAIDAPET CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | Admitted-Finance |
| 4 | Rejected-Technical NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | Rejected-Technical Experience Certificate submitted is not as per NIT conidition |
| 5 | Rejected-Technical | Rejected-Technical Audited Balance sheet for last financial year and digitally signed tender documents not submitted |
Tender Value
₹53.3 L
EMD Value
₹1.1 L
Closing Date
4 Mar 2022, 11:30 amClosed
Regional Manager
AAI CARGO LOGISTICS AND ALLIED SERVICES COMPANY LIMITED
Modification of Fire fighting system and fire alarm system at Integrated Air Cargo Complex Meenambakkam, Chennai Airport
2022_AAICL_105113_1
AAICLAS/ELECT-28(R)/FIRE/2022
Open Tender
Electrical Works
Works
180 days
Integrated Air Cargo Complex Meenambakkam
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
AAICLAS
₹1.1 L
15 Sept 2022
11 Feb 2022
9 Mar 2022
11 Feb 2022
4 Mar 2022
19 Feb 2022
11 Feb 2022 - 19 Feb 2022
Amount
SUB HEAD-I: (FIRE FIGHTING SYSTEM) Supply and installation of Temporal Horn, 84.4/79.4 dB, 15,30,75,110 cd Strobe, red complete as required. XLSG1R-HDVM. Make : Honeywell/EST
Supply and installation of Single Input Module complete as required. SIGA-CT1. Make: Honeywell/EST
Supply of Detector Base - Standard complete as required. SIGA-SB. Make:Honeywell/EST
Supply and installation of Intelligent Fixed Temperature Heat Detector - 135F complete as required. XLS-HRS Make:Honeywell/EST
Supply and installation of Isolator Module complete as required. XLS-IM. Make: Honeywell/EST
Supply and installation of Intelligent Photoelectric Smoke Detector complete as required. XLS-PS. Make: Honeywell/EST
Supplyand installation of Control relay module complete as required. SIGA - CR. Make: Honeywell/EST
Supply and installation of Manual pull station - Lexan complete as required. XLS-278. Make: Honeywell/EST
Supply and installation of Dual Signature Driver Controller including programming and up dating in the existing panel complete as required. 3-SDCC 1. Make: Honeywell/EST
Supply of 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable complete as required.
Laying of one number 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable on surface for fire alarm circuit etc., complete as required.
Supply and installation of AC to DC convertor with controls for power supply to Beam detector and other devises complete as required. (230/24v Dc 5 amps)
Supply and installation of 450 - 600 W Booster power Amplifier with 3U height 21'' case for rack mounting LED display on front panel (approved Make: Bosch)
Supply and installation of voice alarm system with plena voice alarm router having 6 zones (Make: Bosch)
Supply and installation of 2 Zone conventional fire alarm panel
Supply and installation of 2 Zone conventional fire alarm detector
Supply and installation of Fire alarm conventional manual call point
Supply and installation of Conventional Hooter
Supply and installation of Beam detector back box (8X6)
Supply and installation of Manual call point back box (4X3)
Supply and installation of Detector back box (2X2)
Supply and installation of Weather proof manual call point
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling/truss with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
25 mm dia
32 mm dia
40 mm dia
50 mm dia
100 mm dia
150 mm dia
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required.
Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
150 mm dia
Supplying and fixing 63 mm dia,2nos of 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Stainless Steel (Grade 304)
Supplying and fixing of hose cabinet of size 900mm X 600mm X 500mm make of 2 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate internal/external hydrant with Sluice valve 2 Nos. 15 mtr. Long hose pipe, 1 No. branch pipe, duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect, for Internal/external hydrant, as reqd.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories
Pendent Sprinkler
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc., of follwing sizes as required
150mm dia
Preparation of Layout drawing of AAICLAS , Cargo complex indicating location of Pump house, Pipe line grid, location of Hydrant valves , warehouses with sprinklers , detection devise detals , submission of application for Fire NOC from Fire Department and obtainig NOC for AAICLAS complex all as required
VESDA Laser Focus Detector with LED display VLF 250
Capillary Sampling Points E700-TA+CSC+CT+SP+SPLR
24V DC, 0.5A power supply unit with battery backup VPS 220E VPS 220
Sampling HD PVC Pipe of size 25mm OD, 21mm ID smooth bore pipe
DElite System Engineering (India) Pvt. Ltd.
GLYPTIC
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .