Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹56.7 L+₹6.1 L (12.0%)Rejected-Finance STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L2 | Rejected-Finance BEING L2 BIDDER |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
21 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPL REPAIRS TO BLDG NO ET-140 AND OTHER SANCTION WORKS AT HATTIGOR MILITARY STATION UNDER GE RANGIA
2022_MES_506058_5
8527/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
HATTIGOR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹89,000
Yes
6 Jun 2022
7 May 2022
23 May 2022
7 May 2022
21 May 2022
9 May 2022
60 days
Amount
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
M&L for G I Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L rendering 10mm thick on other than fair faces of brick work or on other side of lathing in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, complete all as specified and as directed by Engineer-in-charge.
S&F MS steel work in tubular trusses including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 along with one shop coat of zinc chromate primer paint , complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, wind ties, clamps and similar small articles etc. conforming to Fe-290 Gde E-165, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
M&L for 4 mm thick non-asbestos fiber cement building boards, fixed to G.I. frame (snapgrid) of standard section as per manufacturer's instruction with 2 mm thick GI wire suspender as in ceiling complete all as specified and as directed by Engineer-in-charge.
S&F solid PVC wall paneling consisting of 5 mm thick PVC wood grain printed PVC sheet inclusive of solvent cement and fixing at site as per specification and directed in any position with screws, complete all as per specified and as directed by Engineer-in-charge.
S&F 5mm thick PVC sheet fillets of width 35mm for wall paneling inclusive of fixing on wall to make frame as per specifications and drawing, complete all as per specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in footpath / hardstanding / pavings / plinth protections, finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L precast Coloured cement concrete PU finished chequered tiles 300x300x25mm thick set jointed and pointed in with grey cement and pigment laid over and including 20mm thick screed bed in CM 1:4 in floorings, complete all as per specified and as directed by Engineer-in-charge.
Taking down chowkat or frame not exceeding 1.5 Sqm each (without taking off shutter from the frame), complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description not exc. 1 sqm each, complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
M&L 35 mm thick second class hardwood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of member (Bottom 250mm, stiles 100mm, top 120mm & lock rail 160mm wide) as specified in SSR part I section & clause 8.24 (a) complete all as specified and as directed by Engineer-in-charge.
S&F 30 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. for windows and ventilators etc complete all as per specified and as directed by Engineer-in-charge.
S&F anodised Aluminium colour powder coated ventilator sliding glass frame made up 89 mm /32 mm 2.75 mm thick aluminium section & shutter of suitable size without sash bar aluminium section using suitable section with 3-4 mm thick tinted glass including all necessary joining cleats, hold fast, rubber gasket, anodised snap beading, anodised aluminium fittings, suitable aluminium handle and locking arrangment etc, complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
S&F 3 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as specified and as directed by Engineer-in-charge.
S&F galvanised mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F fancy type curtain/hanger rods of mild steel pre painted with fixing decorative bracket stops rollers etc complete all as per specified and as directed by Engineer-in-charge.
S&F 75 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S & F 75 mm long extruded Aluminium alloy anodised Butt hinges with galvanized mild steel hinge pin type C-21, complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm long extruded Aluminium alloy anodised butt hinges with galvanized mild steel hinge pin type C-21, complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm long extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F aluminium alloy 300 mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
S&F 300 mm long mild steel Helical door Spring of approved quality, complete all as per specified and as directed by Engineer-in-charge.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
Dismantling boarding, any description fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
M&L 20 mm thick 2nd class hard wood boarding clean sawn with butt joints fixed with nails in any situation (except flooring and skirting), complete all as specified and as directed by Engineer-in-charge.
M&L anti termite treatement of soil under existing floor using emulsion @ one litre per hole 300mm apart including drilling and plugging 12 mm dia holes with cement mortor 1:2 (1 cement : 2 coarse sand) to match the existing floor complete all as per specified and as directed by Engineer-in-charge.
M&L for anti termite treatment to the soil alongwith external perimeter of bldg at the rate of 2.25 ltr of emulsion per metre of the perimetre wall complete all as per specified and as directed by Engineer-in-charge.
M&L for ATT at points of contract of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as per specified and as directed by Engineer-in-charge.
M&L second class hard wood plain fillets, square or rectangular or triangular in section, clean sawn, secured with nails or brads having sectional area not exceeding 03 sqcm complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surface and applying two coats of distemper oil emulsion on wall surfaces over a coat of chalk whiting primer complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of cresote oil, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
M&L for Coloured Glazed ceramic tiles 300 x 200 x 6 or 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick screed in CM (1:4), complete all as specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
M&L cleaning top surfaces by washing & brooming down or by wire brushing, removing grass, raking out joint to receive plaster and removing debris, grass etc. outside the defence land, complete all as specified and as directed by Engineer-in-charge. Note : 1. plaster shall be measured and paid separately under relevant item. 2. Rate of this item is inclusive of disconnect fitment as solar heater etc and refixing in same position after compeleting of roof treatment.
M&L for preparation of concrete roof surface appyling roof treatment as under:- (a) Applying bituminous primer @ 0.30 liter per sqm of surface. (b) Applying one coat of 85/25 grade hot bitumen @ 1.20 kg/sqm of surface (c) Laying of APP modified water proofing membrance with non-woven polyster reinforcement on hot applied bitumen with 100mm over lap at joints by torching on the transverse direction and 75 mm on longitudinal direction all as per manufacture's instructions (d) Applying one coat of bitumineous aluminium paint @ 0.10 litre/sqm complete all as per specified and as directed by Engineer-in-charge.
Dismantling of old wooden or babus post fencing in any size and fixed with any wooden or bambu baliies, fillets, rails, posts, etc., in any section including chain link fencing, complete all as per specified and as directed by Engineer-in-charge.
Excavation in post holes (or similar holes) each n.exc 0.5cum in soft/loose soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing of surplus soil to a distance n.exc 50 meters and making good surface, complete all as per specified and as directed by Engineer-in-charge.
M&L plain cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in for fixing post, bed plates, anchorage blocks, corbels, bracket, including necessary form work etc., complete all as specified and as directed by Engineer-in-charge.
S&F Mild steel work in hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O, complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, Fe-410-w (Gde-E-250), complete all as per specified and as directed by Engineer-in-charge.
S&F chain link fencing mild steel GI wire of mesh size 100 mm x 100 mm or cases with 3.15 mm dia MS GI wire, lapped straining and binding withincluding mild steel wire (annealed) not less than 0.9mm dia including provision of binding wire, complete all as per specified and as directed by Engineer-in-charge.
S&F mild steel screw bolts having neck dia. 11 to 15 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 5cm long complete all as per specified and as directed by Engineer-in-charge.
S&F PVC coated chain link fencing PVC coat around mild steel GI wire of mesh size 100 mm x 100 mm or cases with 3.5-4.0 mm dia MS GI wire, lapped straining and binding withincluding mild steel wire (annealed) not less than 0.9mm dia including provision of binding wire, complete all as per specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificied provided for, complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete (nominal mix) type B-l, 1:2:4 (20 mm graded aggregate) as in plinth beam, slab, cover, footing, foundation beam etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in sub base in flooring/ hard standing, complete all as specified and as directed by Engineer-in-charge.
'M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation, complete all as per specified and as directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 100 mm thickness of M-40 grade with grey cement and pigment including dismantling & removing old unserviceable paver blocks, complete all as per specified and as directed by Engineer-in-charge.
Refixing of Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 80-100 mm thickness of M-40 grade with grey cement and pigment including dismantling & removing old unserviceable paver blocks, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 50 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
S&F GI tube 50 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge.
Taking up or down 20 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
S&F GI tube 20 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded & pointed in any morter complete all as per specified and as directed by Engineer-in-charge.
M&L machine cut kota stone slab flooring with 20-25mm thick over 15mm thick screed bed in CM 1:4 and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as per specified and as directed by Engineer-in-charge.
M&L machine cut kota stone in riser of steps, skriting, dado and pillar with 20-25mm thick over 10mm thick screed bed in CM 1:3 and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as per specified and as directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 60 mm thickness of M-35 grade with grey cement and pigment, complete all as per specified and as directed by Engineer-in-charge.
M&L for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in kerb stone, landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube in opening complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing factory made solid panel factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as per specified and as directed by Engineer-in-charge.
S&F in repair angular stop cock 15 mm dia size with wall flange made of cast copper alloy, chromium plated fancy type, complete all as specified and as directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe of 15 mm bore, complete all as specified and as directed by Engineer-in-charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for anti-termite treatement treating the soil under the plinth protection at the rate of 5 litre of emulsion per square metre of surface area complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete (nominal mix) type B-l, 1:2:4 (20 mm graded aggregate) as in beams, lintels etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for form work for side of concrete footings, foundations beam, base of columns & similar works vertical or batter complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work or one side of lathing in cement mortar 1:4 , surface finished even and smooth without using extra cement using water proofing compound in top layers as per manufacturer's direction complete all as per specified and as directed by Engineer-in-charge. Note - WPC shall be measured and paid saparately.
Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge.
M&L rendering 10mm thick on other than fair faces of brick work or concrete block surface in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of oil bound distemper on surfaces of walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement base paint on walls, complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
M&L for 20mm thick screed bed or bedding layer of mortar (1:4) for laying floor surface finishes, complete all as specified and as directed by Engineer-in-charge.
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed and pointed in with grey cement and pigment laid over floor and pointed in neat cement slurry in floors, complete all as specified and as directed by Engineer-in-charge.
S&F 100 mm long stainless steel butt hinges medium weight cold rolled, complete all as per specified and as directed by Engineer-in-charge.
S & F in repair Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges complete all as per specified and as directed by Engineer-in-charge.
M&L for precast cement concrete 1:3:6, type-C1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes, etc.) shelves and similar articles with plain faces and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
S&F GI tube 15 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches complete all as per specified and as directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches complete all as per specified and as directed by Engineer-in-charge.
S&F110 mm dia bore PVC (SWR) bends, complete all as specified and as directed by Engineer-in-charge.
S&F 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position including 20mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 20mm- 210 gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S & F 20 mm stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as per specified and as directed by Engineer-in-charge.
S & F 15 mm stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F 15mm dia PVC connection pipe with PTMT nuts of length 450 mm complete all as specified and as directed by Engineer-in-charge.
S&F Vitreous China squatting pan "Orissa" patern size 580x440mm white with integral foot rest including connection to trap and to flushing pipe, anti-syphonage pipe, etc including 'P' or 'S' trap complete all as per specified and as directed by Engineer-in-charge.
S&F vitreous china wash down water closet pan (pedestal pattern) white, including seat cover, closed pattern with flat bottom and cover with chromium plated hinging device complete all as per specified and as directed by Engineer-in-charge.
S&F PVC 10 ltr capacity low level flushing cistern white with inlet ball valve float and braket and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge.
Supply and fix 100mm dia grating doom of PTMT with minimum weight 25 grams complete all as specified and as directed by Engineer-in-charge.
S&F Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge.
S&F 15mm dia bore pillar tap cast copper alloy with capston heads chroumium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge.
M&L of Reinforced concrete pipes of size 150mm, class NP2, laid and jointed complete with collars complete all as specified and directed by Engineer in Charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 150 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
M&L for 100mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as per specified and as directed by Engineer-in-charge.
S&F MS cloth hang hooks with available 4-6 hanging hooks, complete all as per specified and as directed by Engineer-in-charge.
S&F CP toilet paper roll holder with flap including all necessary fittings, complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore Chromium plated 2 way bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
M&L for construction of septic tanks, exc, in ordinary soil, foundation in PCC (1:2:4), brick work in CM (1:4), RCC (1:1.5:3) Slab covers including RCC(1:1.5:3) precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete for 20 users.as per drg. No. TD/SZ/504 1/1, complete all as per specified and as directed by Engineer-in-charge.
Construction of Soakage wells including excavation in any ordinary soil, foundation in PCC (1:3:6) type C1, walls of honey combed brick masonary with top ring of RCC (1:1.5:3) type A1 concrete including intercepting chamber and screen chamber made of brick masonary in CM (1:4), RCC cover slab in (1:1.5:3) type A1 cover, inter connecting pipes of RCC/DWC , filled with brick bats of size 1.8 M Dia X 3.00 M effective depth, complete all as per specified and as directed by Engineer-in-charge.
S&F pressed steel frames (125x60) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate and inside filled with PCC 1:3:6 (12.5mm graded stone aggregate) etc complete all as specified and as directed in SSR Part-I
S&F factory made solied panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottomrails. MS frame shall be covered with heatmoulede plain colour PVC 'C' channel having a PVC sheet strip of 20mm widthstuck inside with slovent cement for stilesand plain colour PVC sheets for top rall,rock rail & bottom rall on either side & asgap insert for top rail & bottom rall; paneling of plain colour PVC sheet to befitted in the MS frame welded/sealed to the stiles & ralls with suitable PVC sheet beading and joined together with solvent cement but wire gauzed i.e panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm MS solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly. complete as per specified and as directed by Engineer-in-charge.
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and separating serviceable fittings for reuse in the same work and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc all complete all as specified and directed complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully unserviceable main switches and DB’s including wooden boards and removing from site including making good disturbed surfaces of walls complete all as per specified and as directed by Engineer-in-charge.
Dismantling of house service brackets of any size and type and making good the distrubed wall surfaces complete all as per specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 140 above but for one ceiling/exhaust fan point controlled by one switch.
All as per serial item No. 140 above but for one 3 pin 5 Amps socket outlet on independent board.
All as per serial item No. 140 above but for one 3 pin 5 Amps socket outlet on same board.
All as per serial item no. 140 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards.
Supply and fix switch socket combination 05/15 Amp 6 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix socket outlet, 2 in 1, 3 pin 6/5 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 6 Amp 5 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano flush type, 6/5 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix fan regulator electronic type, rotary step, SP 240 Volt, suitable for ceiling fans complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by Engineer-in-charge.
Supply and fix lamp holder, PVC/Polycarbonate type complete all as specified and as directed by Engineer-in-charge.
Taking down old ceiling fan/exhaust fan and refixing only serviceable fans after testing to its original position/location and handing over old unserviceable ceiling/exhaust fans to MES store yard complete all as specified and as directed by Engineer-in-charge.
Supply and fix exhaust fan 1200 RPM, AC, single phase 230/240V, 50 Hz of size 300 mm sweep with louvers including cutting of wall to suitable size to fix the exhaust fan with nut bolts etc., complete all as specified and as directed by Engineer-in-charge.
S&F wall Security light fittings 1x 15 Watt LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openning seperate driver compartment with IP65 protection and impact resistance of IK07 and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F building security light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and clamp of required shape and length with bolts nuts and washers suitable for building security light including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F PVC rectangular block for mounting, DBs, etc. with 3mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep complete all as specified and as directed by Engineer-in-charge.
S&F House service bracket (Hook type) complete with 40 mm dia GI pipe 3.00 m long, medium grade, two Nos. of 90 degree bends, M.S hook and stay or guy complete all as per specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 08 way double door DB with din rail and suitable bus bar complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 04 way double door DB with din rail and suitable bus bar complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 6-32 Amp 10KA braking capacity 230/240 volt AC, complete all as specified and as directed by Engineer-in-charge.
S&F XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of size 10 Sqmm 2 Core including testing, complete all as specified and as directed by Engineer-in-charge.
S&F 32 mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm fixed to walls, ceilings or in floors etc. complete all as per specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 32 mm bore light grade for protection of UG cable, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Supply and fix 6 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-charge.
Supply and laying 3-layer PP-R Pipes 50 mm dia ( PN 16/ SDR 7.4) with all fittings laid in trenches including testing complete all as per specified and as directed by Engineer-in-charge.
Supply and laying 3-layer PP-R Pipes 32 mm dia ( PN 16/ SDR 7.4) with all fittings laid in trenches including testing complete all as per specified and as directed by Engineer-in-charge.
Supply and laying 3-layer PP-R Pipes 25 mm dia ( PN 16/ SDR 7.4) with all fittings laid in trenches including testing complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing PP-R Gate valves (brass insert) suitable for PP-R pipe of outer dia 32 mm complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing PP-R Gate valves (brass insert) suitable for PP-R pipe of outer dia 25 mm complete all as per specified and as directed by Engineer-in-charge.
Making connection of PP-R distribution branch with PP-R main of 50 to 75 mm sizes by providing and fixing tee including cutting and making fusion joint etc. complete all as per specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S KIRAN ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .