Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | ₹8.2 L Quoted ₹8.5 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹9.0 L+₹57,885 (6.84%)Rejected-Finance | ₹9.0 L+₹57,885 (6.84%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹11.2 L+₹2.8 L (32.6%)Rejected-Finance | ₹11.2 L+₹2.8 L (32.6%) | L3 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | M/S SATISH KUMAR SINGH & SONS L3 | Soma Enterprises L2 | M/S SHEO KUMAR SINGH AND SONS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/alluminium point, wiring (light, fan, socket or power) complete including fixtures and fitting such as switches, ceiling roses, pendants, regulator socket light fitting etc, removing materials to store for keeping in safe custody for or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of walls , floors etc., complete all as specified and as directed. | 235 | Each Point | 300 ₹70,500 | 50 ₹11,750 Lowest | 195 ₹45,825 |
| 2.00 | Material and labour for concealed point wiring complete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metallic PVC rigid conduit medium grade of suitable size (minimum 20mm bore) and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC insulated 1.5 sq mm copper conductor for each continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6 mm thick modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet etc. for one light point point controlled by one way 6 Amp switch, complete all as specified and as directed.
Note :- (i) Cost of PVC conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortar (1:4), matching with existing colour/paint of surface are deemed to be included in the quoted rate. (ii) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | 62 | Each Point | 2,500 ₹1,55,000 | 1,500 ₹93,000 | 1,250 ₹77,500 Lowest |
| 3.00 | All as per item No. 2.00 here in above but for one fan point controlled by one way 5/6 Amp switch and regulator, complete all as specified and as directed. | 16 | Each Point | 2,500 ₹40,000 | 1,500 ₹24,000 | 1,280 ₹20,480 Lowest |
| 4.00 | All as per item No. 2.00 here- in-above but for one 5 pin socket outlet 6 Amps on independent board, complete all as specified and as directed. | 12 | Each Point | 2,500 ₹30,000 | 1,500 ₹18,000 | 1,340 ₹16,080 Lowest |
| 5.00 | All as per item No. 2.00 here- in- above but for one 5 pin socket outlet 6 Amp on same board with other switches, complete all as specified and as directed. | 10 | Each Point | 3,000 ₹30,000 | 1,500 ₹15,000 | 370 ₹3,700 Lowest |
| 6.00 | All as per item No. 2.00 here- in- above but for One bell/buzzer point controlled by one push button same board with other switch or independent board, complete all as specified and as directed. | 6 | Each Point | 2,000 ₹12,000 | 1,500 ₹9,000 | 1,260 ₹7,560 Lowest |
| 7.00 | All as per item No. 2.00 here-in-above but for one 16 Amps socket outlet using by 4.0 sq mm copper conductor cable with 4.0 sq mm PVC insulated single core copper cable for earth continuity conductor, complete all as specified and directed. | 10 | Each Point | 2,000 ₹20,000 | 1,800 ₹18,000 Lowest | 2,425 ₹24,250 |
| 8.00 | All as per item No. 2.00 here-in-above but for one 16 Amps socket outlet using by 2.5 sq mm copper conductor cable with 2.5 sq mm PVC insulated single core copper cable for earth continuity conductor, complete all as specified and as directed. | 19 | Each Point | 2,000 ₹38,000 | 1,800 ₹34,200 | 1,450 ₹27,550 Lowest |
| 9.00 | Material and labour for point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multi-stranded copper conductor, PVC insulated unsheathed FRLSH cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes , 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multi-stranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. Note :- (i) Cost of PVC casing caping, making holes though the wall and inserting suitable PVC pipe, if necessary, making good disturbed wall surfaces including finishing with cement mortar (1:4), matching with existing colour/paint of surface are deemed to be included in the quoted rate. (ii) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | 50 | Each Point | 2,000 ₹1,00,000 | 1,500 ₹75,000 | 950 ₹47,500 Lowest |
| 10.00 | All as per item No.9.00 here-in-above but for One 3 pin 5 Amps socket out let points on independent board, complete all as specified and directed. | 10 | Each Point | 2,000 ₹20,000 | 1,500 ₹15,000 | 960 ₹9,600 Lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
25 Jul 2026, 6:00 pmClosed
AGE (I) AF PURNEA
AGE (I) AF PURNEA, P.O - CHUNAPUR AIR FIELD, DIST- PURNEA BIHAR, PIN CODE-854303
REPAIR/REPLACEMENT OF INTERNAL WIRING SUB MAIN WIRING, MCCBs, BUILDING SECURITY LAMPS, INDUSTRIAL SOCKETS FANS AND FLAME PROOF LAMPS ETC IN TECH AREA AT AF STN PURNEA UNDER AGE (I) (AF) PURNEA
2026_MES_773948_1
8190/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Purnea
As per tender documents
7 documents required · 7 mandatory
₹500
AGE(I)(AF) Purnea
₹16,000
Yes
1 Sept 2026
22 Jun 2026
27 Jul 2026
22 Jun 2026
25 Jul 2026
6 Jul 2026
22 Jun 2026 - 6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/alluminium point, wiring (light, fan, socket or power) complete including fixtures and fitting such as switches, ceiling roses, pendants, regulator socket light fitting etc, removing materials to store for keeping in safe custody for or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of walls , floors etc., complete all as specified and as directed. | 235 | Each Point | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_866617.xls
BOQ • 0.39 MB
TENDER8190.pdf
Tender Documents • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .