| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Accepted-AOC due to being L1 | |
| 2 | L2₹20.0 L+₹3.3 L (19.7%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹20.7 L+₹4.0 L (24.0%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹23.5 L+₹6.8 L (40.7%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹23.9 L+₹7.3 L (43.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Oct 2021, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO-GARHI PIN-182121
Repair/Maintenance of Window/Split Type AC, Voltage Stabilizers of Capacity upto 7.5 KVA Refrigerator, Water Coolers, Desert Cooler, Deep Freezers and Water Dispensers under GE (Utilities)Udhampur
2021_MES_468360_2
GE/U-31/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
As per Appx A to notice of tender
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹40,000
Yes
10 Nov 2021
23 Sept 2021
11 Oct 2021
23 Sept 2021
7 Oct 2021
24 Sept 2021
Amount
Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 40 Amps, 220 Volts complete suitable for window/ Split type complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable front show grill and supply and fix new front show grill (as per sample approved by GE) for LG/Voltas /Sidwal/Godrej window type AC 1.5/2 Ton complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable inner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split type AC of capacity 1.5 /2.0Ton as existing shape, size and make complete all as specified and directed by Engr–in–Charge. Make: Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
Taking out old existing unserviceable outer unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split type AC of capacity 1.5 /2.0Ton existing shape and size with out compressor complete all as specified and directed by Engr–in –Charge. Make: Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA,5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as below:-
Rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA all as specified & directed by Engr-in-Charge.
Description all as per ser item No.06 here-in-before but of capacity 5KVA.
Description all as per ser item No.06 here-in-before but of capacity 2KVA.
Description all as per ser item No.06 here-in-before but of capacity 1KVA.
Description all as per ser item No.06 here-in-before but of capacity 0.5KVA.
Replacement of unserviceable relay for 7.5KVA & 5KVA,30amp 24volts DC.
Replacement of unserviceable Step down transformer 24 volts 2Amp for 7.5 KVA & 5KVA complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable circuit plate with connection wire complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable relay for 0.5KVA, 1KVA & 2KVA,16Amp 24V DC complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable Voltmeter 0- 300V, AC 75 Sqm complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable Amp meter 0- 30Amp, AC 75 Sqm complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable push switch complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable time delay circuit complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable connector switch 30Amp 220volts AC complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable 3pin socket 5Amps,240volts complete all as specified and directed by Engr-in-charge.
Replacement of unserviceable 3pin socket 15Amps,240volts complete all as specified and directed by Engr-in-charge.
Water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable cooling coil and supply and fix new cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC all as specified and directed by Engr–in–Charge.
Taking out old existing unserviceable condensing coil and supply and fix new condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC all as specified and directed by Engr–in–Charge.
Repair/replacement PCB for LG /Voltas/Lloyd/Hitachi/Godrej window type AC 1.5 ton / 2Ton capacity complete all as directed by Engr-in-Charge .
Repair/replacement PCB for LG /Voltas/Hitachi/Lloyd/Godrej split type AC 1.5ton/2Ton cap complete all as directed by Engr-in-Charge .
Taking out old existing unserviceable coil Senser and supply and fix new coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr–in–Charge.
Taking out old existing unserviceable Senser and supply and fix new senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr–in–Charge.
Taking out old unsv blower and supply and fix new blower(plastic body) of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-charge.
Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-charge.
Supply and topping up of refrigerant gas R-600 in Referigerator complete all as specified and directed by Engr-in-charge.
Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of L -Shape thimble brass in pk(50Nos in one pkt) complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of thimble brass(50Nos in one pkt) suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of unserviceable Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr–in–Charge.
Supply & fix in replacement flexible drain pipe for Window type/Split Type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable swing motor and supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton complete all as specified and directed by Engr-in-charge. Make:- LG/Voltas/Hitachi/Godrej.
Taking out old existing unserviceable compressor and supply and fix new hermetic/Rotary sealed unit compressor and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to window type ACs/ Split Type ACs:- (a) Sealed unit (Compressor Rotary Type) Suitable for capacity 1.5 Ton Window type/spllit type ACs. Make-LG/Godrej/Hitachi/universal
Taking out old existing unserviceable compressor and supply and fix new hermetic/Rotary sealed unit compressor and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to window type ACs/ Split Type ACs:- (a) Sealed unit (Compressor Rotary Type) Suitable for capacity 2Ton Window type/spllit type ACs. Make:- LG/Godrej/Hitachi/universal
Taking out old existing unserviceable compressor and supply and fix new hermitically /Rotary sealed unit compressor and making connection of suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per existing unit of latest new model of same manufacturer with same specification conforming to original compressor including recharging with refrigerant gas F-22/R-134A,R-600, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and changing parts with gas brazing and leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to Water coolers, refrigerator and deep freezers:-
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) in original suitable for Water cooler of capacity 40/80 Ltr complete all as specified and directed by Engr-in-charge. Make:– Godrej / Blue Star /Voltas
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) in original suitable for Water cooler of capacity 60/120 Ltr complete all as specified and directed by Engr-in-charge. Make:– Godrej / Blue Star /Voltas.
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) in original suitable for Water cooler of capacity 150/180 Ltr complete all as specified and directed by Engr-in-charge. Make:– Godrej / Voltas /Blure Star.
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) in original suitable for 165/170 Ltr Refrigerator, complete all as specified and directed by Engr-in-charge. Make:- Godrej /LG/Voltas.
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) in original suitable for 270 to 290 Ltr Refrigerator, complete all as specified and directed by Engr-in-charge. Make - Godrej /LG/Voltas.
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) in original suitable for more thatn 310 Ltr Refrigerator complete all as specified and directed by Engr-in-charge. Make:- Godrej /LG/Voltas
Taking out old existing unserviceable compressor and supply and fix new sealed unit (compressor) suitable for 320 litres Deep Freezers in original, complete all as specified and directed by Engr-in-charge. Make:- Godrej /Voltas/Blue Star
Supply and fix in replacement and testing of complete new Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts, bolts, main lead as required etc against burnt defective motor of following capacity/Models as under:- (a) Fan motor1/16 HP single shaft for water cooler complete all as specified and directed by Engr-in-charge. Make:- Air master/Crompton
Fan motor1/20 HP (in replacement) single shaft for water cooler as per the original make of complete fan motor complete all as specified and directed by Engr-in-charge. Make:- Air master /Crompton/Havells.
Fan Motor 1/35HP (in replacement) single shaft for water cooler complete all as specified and directed by Engr-in-charge. Make:- Air master/Crompton/Havells.
Fan Motor 1/70HP (in replacement) single shaft for water cooler side holder, bushes with main lead complete all as specified and directed by Engr-in-charge. Make:- Air master/Crompton/Havells.
Supply and fixing in replacement of Fan motor with fan suitable for LG double door 286ltr / 310 Ltr refrigerators complete all as specified and directed by Engr-in-charge.
Fan motor (in replacement) of 165/170 Litre Refrigerator and supply and fix new fan motor of existing make, shape and size directed by Engr-in-Charge.
Description all as per Srl Item No 44 above but suitable for single door 310 litre Refrigerator complete all as specified and directed by Engr-in- Charge .
Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size all as directed by Engr-in-Charge.
Fan Motor of same model and type, single phase 230V (in replacement) complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps and testing complete in all respect all as specified and directed by Engr-in-charge. Make:- Air master/ Crompton/Havells
Description same as Srl item No 47 but Blower Fan Motor single shaft for Split type AC complete with base, clamps, side holders, rubber bushes complete all as specified and directed by Engr-in-charge.
Description same as Srl item No 47 Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG Make complete all as specified and directed by Engr-in-charge. Make:- Air master/Crompton.
Taking out old existing unserviceable Starting Capacitor of capacity 50+6 mfd supply and fix new Multi purpose Running Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr–in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Running Capacitor of capacity 50+2 mfd and supply & fix new Multi purpose Starting Capacitor of capacity 50+2 mfd for window/split AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 40+80 mfd and supply and fix new Multi purpose starting Capacitor of capacity 40+80 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 40+60 mfd and supply and fix new Multi purpose starting Capacitor of capacity 40+60 mfd for water cooer complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 80/100 mfd and supply and fix new Multi purpose Running Capacitor of capacity 80/100 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 45+5 mfd and supply and fix new Multi purpose running Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 36+6 mfd and supply and fix new Multi purpose running Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 10 mfd and supply and fix new Multi purpose running Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 4 mfd and supply and fix new Multi purpose running Capacitor of capacity 4 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 20 Mfd and supply and fix new Multi purpose running Capacitor of capacity 20 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable thermostate and supply and fix new thermostate for water cooler of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2ton window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2 ton split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance all as directed by Engineer-in-Charge.
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels complete all as directed by Engineer-in-Charge.
Replacement of Khas khas set for the doors of desert coolers all as directed by Engineer-in-charge.
Servicing window/split type air conditioner 1.5 TR capacities of any make by opening the indoor/ outdoor unit ,cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water ,greasing fan motor ,rectification of loose electric connections and replacement of u/s knobs of electrical items complete all as directed by the Engr-in-Charge.
Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator, supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning complete all as directed by Engineer-in-Charge.
Disconnecting and taking down unserviceable thermostat from split type AC and supply and fix new thermostat for split type AC 1.5/ 2.0 Ton cap AC and testing the same for satisfactory performance all as specified and as directed by Engineer-in-Charge.
Pressure testing and rectifying leakage in the system of window/split air conditioner up to 2 TR capacity including testing for satisfactory performance, commissioning all as directed by Engineer-in-Charge.
Copper tubing (in replacement) of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
Cleaning of coils of Window/Split by using alkaline based coil cleaner (Non Acid based) including taking down filters, spraying the diluted alkaline based coil cleaner, leaving it for five minutes and then flushing with running water. Fixing back the filters. Testing & re-commissioning etc., complete all as directed by Engineer-in-Charge. Make: C-Shine
Taking out old existing unserviceable Fan motor 4x4 and supply and fix new Fan motor 4x4 for water cooler of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Sub main wiring (in replacement) with two single core PVC insulated, unsheathed copper conductor cable, 1100volts grade of size 4.0 sqmm, FRLS in and inculding concealed PVC conduit, heavy duty, ISI marked, of dia 25mm and thickness not less than 2mm with all accessories such as bends, Tees, elbows, reducer socket, bell mouth,tube ends etc including cutting chases, pinning in masonry walling & making good to facing by pointing / plastering in cement mortar 1:3 to ends or edges for concealed wiring inculding 4.00 sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as directed by Engineer-in-Charge. Note :- Two run of wire and single run of earth wire 1RM of PVC conduit shall be measured as one unit.
Taking out old existing unserviceable diacharge valve and supply and fix new discharge valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable suction valve and supply and fix new suction valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable bush and supply and fix new bush of 1.5/2 ton split type AC .of any capacity makle LG/ Voltas complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable filter drier and supply and fix new drier of Split /Window 1.5/2.0 Ton Ac LG. Sidwal, Carrier and Voltas (as per sample approved by GE) of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable capillary and supply and fix new capillary of 1.5/2 ton split type /window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable dead Nut and supply and fix new dead nut of 1.5/2 ton split type /window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable NRV and supply and fix NRV of 1.5/2 ton split type /window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Replacement of existing unserviceable remote control unit Suitable for 1.5 / 2.0 Ton split type AC working on both ( Hot & Cool) (as per sample approved by GE) and complete all as specified and directed by Engr-in-Charge.
Sub main wiring with two single core PVC insulated unsheathed copper conductor cable 1100 volts grade 6.0 Sq mm size HRFR in and including concealed PVC conduit heavy duty ISI marked 25mm dia non metallic with all accessories such as bends, Tees, elbows, reducer socket, bell mouth, tube ends etc. including cutting chases, pinning in masonry walling & making good to facing by pointing/plastering in cement mortar 1:3 to ends or edges for concealed wiring including 4.0 Sq mm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as specified and directed by Engr-in-Charge. Note: Two run of wire and single run of earth wire and 1 RM of PVC conduit shall be measured as one unit.
Repair of Deep frezeer of capacity 320 ltr capcity by dismatiling the whole condensing as well as cooling coil and finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confroming no leakage . Then reassembling the same deep freezer by provinding proper insulation material at the disturbed area complete all as per entire satisfaction of Engineer-in-Charge.
Repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of the water cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including providing the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage complete all as specified and directed by Engr-in-Charge.
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note: All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract.
Taking out old existing unserviceable drain pipe and supply and fix new drain pipe of 1.5/2 ton split type/window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable NRV spare parts from air curtain such as Air Curtain motor, Air curtain door sensor, Air curtain blower, blower wheels replacement with new and fix of any capacity or size complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable foam insulation and supply and fix new foam insulation of 1.5 / 2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE)
PREM NATH KHAJURIA AND SONS
slathia construction works
LUXMI ELECTRONIC WORKS
ARNABH ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .