Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹40.2 L+₹31,057.09 (0.78%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹42.4 L+₹2.5 L (6.30%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹44.1 L+₹4.3 L (10.7%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹45.0 L+₹5.2 L (13.0%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
7 Jun 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
INTERNAL/ EXTERNAL PERIODICAL SERVICES TO INCL BLDGS WORKS AND MISC E/M WORKS INCLUDING DAILY MAINTS COMPLAINTS AT RR COLONY, TRG AREA, MES QTR, RRRC, GREEN WINDOWS, CC HUT, ARTRAC HUT, TRAINING AREA AND ADJOINING AREA UNDER GE (CENTRAL) DELHI CANTT-
2023_MES_594973_1
GE/C-07/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
5 Jul 2023
12 May 2023
9 Jun 2023
12 May 2023
7 Jun 2023
26 May 2023
12 May 2023 - 26 May 2023
Amount
Preparation of old decorated surface (plastered or unplastered) of walls incl cornices pillar etc by brooming down or steel wire brushing scraping down smoke root mould moss and efforesceent salts and treating oil and greasy spots as applicable and applying one coat of white wash on wall .
All as per item No 01 above but applying two coats of white wash and ditto.
All as per item No 01 above but applying one coat of white wash on ceiling.
All as per item No 01 but applying two coats white washing on ceiling.
M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 cms width or girth and applying one coat of synthetic enamel paint , complete all asspecified.
All as per item No 05 above but applying two coats of synthetic enamel paint.
Preparation of wire mesh surfaces by brushing and applying a coat of synthetic enamel paint on GI wire mesh complete (measured over all one side only).
M&L for Preparation of old painted surfaces of steel of any description over 10 cms width or girth and applying one coat of synthetic enamel paint , complete all as specified.
All as per item No 08 above but applying two coats of synthetic enamel paint –ditto-.
Complete removal of existing old treatment on surface from walls with machenical scraper (machine) complete all as specified and directed.
M& L for applying two coats of oil bound distemper on wall surface with roller brush complete all as specified and directed.
M& L for preparing the entire surface with applying 2-3 mm thick birla/ JK wall care putty on walls/ ceiling surface finished even and smooth complete all as specified and directed.
M& L for applying two coats of oil bound distemper on Ceiling surface with roller brush complete all as specified and directed.
M & L preparing old surface including washing, rubbing, filling holes,and uneven surface finishing old surfaces even and smooth with ,JK/Birla Wall care putty/POP, and surface shoulld be even and smooth applying one coat of oil bound distemper on wall surfaces with roller brush of complete all as specified.
Complete removal exising treatment of old/ new surfaces of wall scrubbing by machenical scrapper (machine) with hard brushing ,brooming down or steel wire brushing scraping down smook root mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water and Two coats of weather proofing exterior acrylic emulsion paint over one coat of primer from the same manufacturer white lime wash even and smooth with roller brush complete all as specified and directed.
Demolition of Brick work of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles.
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified.
All As per item no 18 before but except bricks.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished even (incl mixing of WPC) and smooth without using extra cement up to hieght of four storey ,including scaffolding complete Note: Water Proofing Compound will be paid seprately.
M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished even and smooth without using extra cement in multistorey building ,complete all as directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajja in multy storey building etc complete all as specified.
Supply only integral water proofing admixture of approved quality.
M&L preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
Material and labour for preparation of new plastered surfaces as of walls and applying Two coats of weather proofing exterior acrylic emulsion paint over one coat of primer from the same manufacturer complete all as specified and directed.
M&L for new plaster surface two coat of oil bound destemper over 3mm thick of birla white putty including preparation of newly plastered surface etc all as specified.
Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick (above or below grnd level) complete all as specified.
M & L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified.
S & F glass dividing strips, 73mm depth and 5mm wide and inserted in position to conform to design, complete all as specified.
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified.
M&L for Plain, solid, straight chowkats and frames made of 2nd class hard wood wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed,making good , complete all as specified and as directed by Engineer-in-Charge.
S&F for 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L for 35 mm thick 2nd class hard wood glazed and skelton door shutter, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 20(a) and fixed to chowkat, complete all as specified.
S&F 150mm long extruded alumiunium alloy handle fabricated type anodized (D type).
S&F 100 mm long (size) butt hinges medium weight, cold rolled, mild steel, complete all as specified (Fixing included in item 35 here-in-before).
S&F for 150 mm size aluminium, anodised barrel tower bolts of extruded section and fixed to shutter complete.
S&F for MS 300mm size, door spring Pencil type rat tail rod pattern springs including roller and roller plate complete.
S&F for 100 mm size long mortice lock vertical type ,4 levers with key in duplicate, brass body with brass two nos handle fixed in shutters with screw complete all as specified.
Supply&fix two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge.
S&F for galvanized stainless steel wire cloth 0.38mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples including beading complete all as specified and as directed .
Hacking out old broken glass of any thickness size quality or description frame wooden frames /Aluminium frame fixed with wooden beads/aluminium beads and M&L 5.5 mm thick sheet galss ordinary quality and glazing with wooden bead/aluminium beads, complete all as specified.
S & Fin repair 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I.
S & F in repair 500 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I I.
Taking down chowkhat or frame not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame).
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded Complete all Specified and directed.
All as per Srl item No 46 above but without glazing bars.
S&F for bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165.
M&L for preparation of old decoreated external wall of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding.
M&L for preparation of old/new decoreated/undecoreated external wall applying two coats weather proofing exterior acrylic emulsion paint up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding.
M&L for preparation of newly plaster surface of wall of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying and applying two coats of weather proofing exterior acrylic emulsion paint over priming coat premium quality over wall / ceiling complete, including applying 2mm thick wall care putty over disturbed surface during preparation or any reason up to 8 storey bldg including scaffolding complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. Note rate quoted up to G+8 bldg including scaffolding.
M&L for preparation of old decoreated external wall surface by mechanised sander of Berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible, again sand papering thus making surface smooth. and applying two coats of cement base paint on walls complete all as specified and all as directed by Engr-in-Charge . Note :- The prepration of surfaces stage shall be got approved from GE before applying the finishes. Note rate quoted up to G+8 bldg including scaffolding.
Complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of oil bond distemper over complete all as specified and directed.
M&L for prepration of old plstered surfaces of wall and applying two coat of white wash complete all as specified and all as directed by Engineer in charge .
M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
M&L for renderning 15 mm thick in CM 1:4 on any faces of brick/concrete surfaces finished even and fair with out using extra cement complete all as specified. Note rate quoted up to G+8 bldg including scaffolding
M&L for prepration of newly plstered surfaces of ceiling and applying two coat of white wash complete all as specified and all as directed by Engineer in charge .
S&F precast cement concrete Type B0 1:2:4 (12.5 mm graded aggregates) louvres and jallies, 50mm thick set in CM (1:4) (measured solid), including all mouldings precast RCC coping/post of size 600x100x50 mm suitable for fixing of RCC Jallies in vertically & horizontally incl demolation existing jalli and complete all as specified and directed.
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortor of any diameter incl bends Note rate quoted up to G+8 bldg including scaffolding.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete. Note rate quoted up to G+8 bldg including scaffolding.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete. Note rate quoted up to G+8 bldg including scaffolding.
S & F 100 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding.
S & F 75 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding.
S&F in repairs PVC (SWR) bends of any radius ( 110mm bore) including jointing with solvent cement complete all as specified.
S&F in repairs PVC (SWR) bends of any radius ( 75mm bore) including jointing with solvent cement complete all as specified.
S&F in repairs PVC (SWR) vent cowl of 110 mm bore.
S&F in repairs PVC (SWR) vent cowl of 75 mm bore .
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Pratap chowk and adjoining area.
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Pratap chowk and adjoining area.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 71, 72 and 73 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at Pratap Chowk Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to complaint cell at 0900 hrs daily and get the job card for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this. (h) Daily attendance register will be maintained by conserned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 09 pm to 05 am). Notes for Item No. 4 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at Pratap Chowk Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday . Electrician shall report to complaint cell at 2100 hrs daily . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only switch piano 6 amp SP two way, ISI marked Make:Havells Reo or equivalent in legrand/Schneider.
Supply only socket piano outlet 6 Amp flush button type all as specified Make:- Havells Reo or equivalent in legrand/Schneider/.
Supply only bell push single pole 6 Amps all as specified Make:- Havells Reo or equivalent in legrand/Schneider.
Supply only switch piano flush button type single pole 16 Amps. Make:- Havells Reo or equivalent in legrand/Schneider.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole . Make:- Havells Reo or equivalent in legrand/Schneider.
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete. Make : Anchor/ Havells/ cona
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.Make:- Legrand/Schneider/ ABB
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. Make:-IndoAsian, Legrand or Havells.
Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells..
Supply only ceiling rose surface PVC type with three terminals.Make:- Havells/Polycab/Anchor.
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed. Legrand/Havells Reo/ Anchor
Supply only insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed. Make : Havells / Crompton Greaves/ Anchor
Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
Supply only industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
Supply only relacement plug top 16 Amps 3 pin 230- volts Make:- Crabtree/Havells Reo.
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. (Make-Wipro / Crompton Greaves / eqivalent in Phillips).
Supply only in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base. Make:- Philips/Wipro/Jaquar
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/Indoasian /Havels.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/ Indoasian/ Havlls.
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/Indoasian/ Havells.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/Indoasian/ Havells.
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB.
Supply only MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB.
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed.
Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) . Make- Legrand /Havells/Crabtree/Polycab.
Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked)
Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :- Make :-As per sample.
(a) T Cover
(b) Sheet 4" x 4" two cuttings suitable for two piano switches.
(c) Sheet 4" x 7" three cuttings suitable for three piano switches.
(d) Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches.
(e) Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
(f) Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
supply only hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. Make - Havells / Jaquar / Bajaj.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified. Make : RR Kable, Gloster, Havels
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.Make:-Finolex ,Gloster, RR Kable
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified. Make:- Finolex ,Gloster, RR Kable
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 6 sqmm with approved coloured code completed all as specified. Make:- Finolex ,Gloster, RR Kable
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 10 sqmm with approved coloured code completed all as specified. Make:- Finolex ,Gloster, RR Kable
Supply only replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge
Taking down sub main wiring off sizes etc complete all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 4.00 sqmm (Main Cable and neutral) and one run of 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed. Make : RR Kable, Gloster, Havels
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 6.00 sqmm (Main Cable and neutral) and one run of 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed. Make : RR Kable, Gloster, Havels
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 10 sqmm (Main Cable and neutral) and one run of 10 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed. Make : RR Kable, Gloster, Havels
Schedule of Credit
imran construction company
M/S GR construction compony
GIAN ENGINEERS
Pall Associates
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .