Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | Admitted-Finance |
| 2 | Admitted-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Rejected-Technical NO 33 JEENIS ROAD SAIDAPET CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | Rejected-Technical Experience certificate not as per NIT |
Tender Value
Refer Docs
Closing Date
14 Jun 2021, 4:00 pmClosed
Regional Manager
AAICLAS, Integrated Air Cargo Complex, Meenambakkam,Chennai Airport, Chennai-600016
Facility Management and Maintenance of Fire fighting system and Fire alarm system at Integrated Air Cargo Complex AAICLAS Meenambakkam Chennai Airport
2021_AAICL_77721_1
AAICLAS/FMC/FIRE-25/2021-2022
Open Tender
Electrical Works
Works
720 days
Integrated Air Cargo Complex Meenambakkam
As per NIT
4 documents required · 4 mandatory
₹1,180
AAICLAS
Exempted
1 Jul 2021
21 May 2021
18 Jun 2021
21 May 2021
14 Jun 2021
29 May 2021
21 May 2021 - 29 May 2021
Amount
SUB HEAD: I (Fire hydrant system) Facility management services for fire hydrant sprinkler Systems and all type of fire extinguishers at cargo admin block Export & Import shed courier sections CUDCT area and all other buildings annexes in coming under the Intergrated Air Cargo complex Chennai,Airport as per inventory, monitoring and maintenance activities to ensure the serviceability on round the clock basis including maintaining records/ data entry/ Supervision of the total system etc as per the specifications & directions of Engineer-In-Charge. (Refer Annexure-A1 for inventory of equipments, Annexure-B1 for monitoring & maintenance activities, Annexure-C Manpower details)
For First Year
For Second Year
SUB HEAD: II (ARC Works- to carryout the works, Separate manpower other than manpower mentioned in SH:I Should be deputed when as required basis)
Dismantling of existing split case/ radially split case type Centrifugal pump sets of following make/ models for necessary overhauling/ repairing i/c supply and replacement of both side bearings, mechanical seal, petty materials like stud bolts, gland packing, gasket, rubber bush for coupling etc. Cleaning and Greasing of bearings, reassembling, realignment of the pump with motor, testing, commissioning and painting etc. complete as required.
Kirloskar 85HP to 100 HP
Kirloskar 60HP to 75 HP
Kirloskar/Mather-platt 15HP
Dismantling of following valves from the existing fire fighting water pipe line, Complete removal of scale deposits by acid dipping, scrapping and overhauling, replacement of packings, nut & bolts and gaskets etc. as required & reinstalling the same in its original postion i/c. testing and commissioing complete as required.
For 10" and 12" Gate/Non Return/Globe/Foot valves
For 6" and 8" Gate/Non Return /Foot valves
From 2" to 4" Gate/Non Return/Foot valves
Dismantling of following damaged Ms Heavy class pipes from the system which are on surface, supplying and installing new MS Heavy class pipes complete with flanges, bends, tees, supports etc. by welding with approved make & specifications as required.
25mm (IS: 1239, Heavy class)
50mm (IS: 1239, Heavy class)
80mm (IS: 1239, Heavy class)
100mm (IS: 1239, Heavy class)
150mm (IS: 1239, Heavy class)
200mm (6.35 mm Thick)
250mm (6.35 mm Thick)
SUB HEAD: III BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
80mm dia (PN 1.6 Rated)
100mm dia (PN 1.6 Rated)
150mm dia (PN 1.6 Rated)
Providing and fixing the following size of Non return valves of approved make after dismantling the existing damaged one i/c replacement of the gasket, nut, bolts etc. as required.
100 mm Non return valve
150 mm Non return valve
Dismantling of following existing faulty sprinkler flexible hose drops from the system, which are inside the false ceiling, supplying and installing new flexible hose drops up to 1.5Mtr Length along with all required connectors, threading, coupler etc. as required.
Providing one welder and one Khallasi along with Electric welding/ gas cutting machine and welding rods/ Oxygen Acetlyne gas for carrrying out leak arresting/ welding of fire fighting hydrants or other welding works during any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency work as and when required.
Supply & replacement of following suitable parts in hydrant delivery/ Landing valves(Single/ Double head), First aid Hose reel drums, other related accessories and valaves in Fire hydrant and sprinkler system (as and when required basis).
Coupling washer
Seating washer
Gasket of suitable thickness
Nut bolts 12mm dia, 3" long
Rubber hose 20mm x 30 Mtr. Suitable for First aid Hose reel drum
O ring seal inside First aid Hose reel drum
25mm forged brass Ball Valve
Brass Shutoff Nozzle with 1/2" ball valve
Hose clamps for rubber hose
25mm GM Air release valve (Screwed type)
Supply and replacement of 100mm dia Pressure guages, 0-200PSI, H. Guru make or as per the approved make, specifications & directions of E.I.C.
Supply & replacement of pressure switch suitable for the existing system with a pressure range of 1 to 10 Bar.
Disconnecting and dismantling of burnt out Induction motor from the system. Complete dismantling of burntout stator winding and through cleaning of stator slots. Rewinding the stator with Class 'F' polyester coated super enameled copper wire and insulating materials i/c. baking, varnishing, finishing and refixing the stator in the motor frame & re-installation in Fire pump room including transportation to and from Pump room etc as required. (Rebate for taking away the burnt copper winding shall be considered while rate quoting done by the contractor)
Painting with two coats of Synthetic enamel paint of approved shade and colour over a coat of red oxide primer over pipe lines including cleaning/ scrapping and remarking the existing indications/numbers with white paint/sticker etc., as required.
Providing & fixing of MS fire Hose box with mounting accessories as per standard with complete as required.
Supply and replacement of SS holding lugs for hydrant valve with complete as required.
Providing & fixing of female coupling of 1 to 2 inch size with nut and bolt with complete as required.
Providing & fixing of MS wheel with nut and bolt with suitable of exisiting for fire hydrant valve as complete as required.
Providing & fixing MS trim kit and gong bell for alarm valve 150 NB with nut and bolt with complete as required.
Supply of 15 mm and 50 mm ball valve with complete as required.
Providing & fixing of pressure gauge needle valve set with suitable exiting pipe complete as required.
Providing & fixing of hose reel nozzle in the exisiting First aid hoze reel with suitable nut and bolt with complete as required.
Providing & fixing of hydrant valve PVC cap, disk washer with nut and screws with suitable existing complete as required.
Providing & fixing of MS key & SS branch with washers etc with complete as required.
Providing & fixing of suitable glass with screws and nuts with exisiting fire box complete as required.
Providing & fixing of fire fighting hose with nut in fire box each length of 15 meters with suitable couplings etc, complete as required.
Providing & fixing of Nipple for sprinkler drainage drain line with complete as required.
Providing & fixing of 150 mm dia MS C class heavy type pipe with double type welding, Suitable Bends and arrenging scoffoding with proper jointing with nut ,bolt and channel in the pipe fixing above surface and below false ceiling with complete as required with the direction of E.I.C
Supply of distilled water with complete as required.
Providing & fixing of 200 mm PN16 Butter fly valve wheel type with suitable nut and bolt with washers complete as required.
Providing & fixing of 250 mm PN16 Butter fly valve wheel type with nut and bolt with washers complete as required
Supply of 25mm ball valve with complete as required.
Suppy & fixing of hose reel drum set with hose 20mm x 30 mtr, hose reel nozzle with nut, bolt, clamp etc. complete as required.
Providing & fixing of single headed fire hydrant Landing valve with suitable bolt nuts and gaskets, etc., with complete as required.
Numbering of Fire hydrant box/Fire hydrant landing pipe with double coated Red enamel paint with numbering in white paint of suitable size as complete as required
SUB HEAD: IV - Fire Alarm system Monitoring & Maintenance of Fire Alarm & PA Systems at cargo admin block Export & Import shed courier sections CUDCT area and all other buildings annexes in coming under the Intergrated Air Cargo complex Chennai, Airport as per inventory comprising of Fire Alarm system (Low Ceiling) & few items(high ceiling), including maintaining records/ reports/ Supervision of the total system etc up to the specifications & directions of Engineer-In-Charge. (Refer Annexure-A2 for inventory of Fire alarm system, Annexure-B2 for monitoring & maintenance activities, Annexure-C for man power)
For First Year
For Second Year
Providing mobile communication facility at two locations with minimum monthly topup of Rs. 300/- for each mobiles etc., as required for the entire contract period.
For First Year
For Second Year
SUB HEAD: V SUPPLY OF SPARES AS AND WHEN REQUIRED BASIS. (Separate manpower) Fire Alarm Accessories
Providing & Fixing of Single Input Module complete as required. SIGA-CT1. Make: Honeywell/EST
Providing & Fixing of Detector Base - Standard complete as required. SIGA-SB. Make:Honeywell/EST
Providing & Fixing of Intelligent Fixed Temperature Heat Detector - 135F complete as required. XLS-HRS. Make:Honeywell/EST
Providing & Fixing of Isolator Module complete as required. XLS-IM. Make: Honeywell/EST
Providing & Fixing of Intelligent Photoelectric Smoke Detector complete as required. XLS-PS. Make: Honeywell/EST
Providing & Fixing of Control relay module complete as required. SIGA - CR. Make: Honeywell/EST
Providing & Fixing of Manual pull station - Lexan complete as required. XLS-278. Make: Honeywell/EST
Supply of 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable complete as required.
Laying of one number 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable on surface for fire alarm circuit etc., complete as required.
Providing & Fixing of Pla relay complete as required. (Pla mpc-2c-24D-5A-L)
Providing & Fixing of power supply for Pla relay complete as required. (230/24v Dc)
Sub Head - VI Supply of following items for recharging / maintenace of fire extinguishers
Printed Stickers with required information as per Instruction of EIC
Dry Type chemical Powder for fire extinguishers
LAKSHMI ELECTRICAL ENTERPRISES
DElite System Engineering (India) Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .