Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Responsive |
| 2 | Accepted-Technical | Accepted-Technical Responsive |
| 3 | Accepted-Technical | Accepted-Technical Responsive |
| 4 | Accepted-Technical | Accepted-Technical Responsive |
| 5 | Accepted-Technical | Accepted-Technical Responsive |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
13 Mar 2026, 2:00 pmClosed
Executive Engineer ED Sumbal
Office of the Executive Engineer ED Sumbal Near Irrigation Colony Sumbal
Installation of 63 KVA Transformer and allied works for providing of Electricity for SWM Facility at Ganda-Bal Hajin Municipal Committee Hajin
2026_PDD_304164_1
EDSbl 37 of 2025-26
Open Tender
Electrical Works
Turn-key
45 days
sumbal
as per SBD enclosed
6 documents required · 6 mandatory
₹1,000
Executive Engineer ED Sumbal
₹53,000
16 Mar 2026
21 Feb 2026
13 Mar 2026
21 Feb 2026
13 Mar 2026
23 Feb 2026
21 Feb 2026 - 23 Feb 2026
Sub Station (SITC Works )
63 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate.
11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185mm² (1Ckt for 200kVA) single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,(ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No and 63 Amp MCCB 3P 16 kA 1 No. for Outgoing Circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-Ø, 4-Wire Trivector Meter (Prodigy ) with suitable ring type CT 200 Amp
Cement bottoming 1:2:4 mix as per Standards 0.48 cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like Aluminium lugs, Jumpers, Binding Tape,
HT Part (SITC Works )
ST Poles 9 Mtr long (410-SP-33).
0.05 ACSR Conductor (Rabbit).
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
V -Shaped GI Cross/GI CI Arms (75X40X6 mm) with top Bracket including Clamps and GI Nuts and Bolts.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Earthing Complete by GI Pipe 40 mm or 20 mm Solid rod 3 mtr long through GI Strip 25X3 mm
Red-Oxide for painting of Poles
Aluminium paint for painting of Poles
Cement Bottoming 1:2:4 mix as per REC standards 0.48cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 550X550X 1650mm for 9 ST poles (410,SP-33 ) (the leftover pit after concreting to be filled with soil and boulders).
Danger Plate with Clamps
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting
Anti-Climbing Device with Clamps
Isolator Double Break 3 Pole ,600 Ampere Horizontal mounting type without Earthing Blade
LT Part (SITC Works )
ST Poles 8 Mtr long (410-SP-15).
0.05 ACSR Conductor (Rabbit).
GI Mukhi clamps with LT Shackle insulators
Earthing Complete by GI Pipe 40 mm or 20 mm Solid rod 3 mtr long through GI Strip 25X3 mm
Red-Oxide for painting of Poles
Aluminium paint for painting of Poles
Providing and laying of Cement Bottoming 1:2:4 mix as per REC standards 0 .40 cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 500X500X 1650mm 8 Mtr ST poles (410,SP-15) (the leftover pit after concreting to be filled with soil and boulders).
Anti-Climbing Device with Clamps
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
SBD37.pdf
Tender Documents • 1.67 MB
BOQ_988047.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .