Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹3.1 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹3.7 Cr+₹60.8 L (19.5%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹3.7 Cr+₹60.8 L (19.5%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹4.1 Cr+₹1.0 Cr (32.0%)Rejected-Finance NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹4.1 Cr+₹1.0 Cr (32.0%) | L3 | Rejected-Finance Not L1 |
| 4 | L4₹4.4 Cr+₹1.3 Cr (40.8%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹4.4 Cr+₹1.3 Cr (40.8%) | L4 | Rejected-Finance Not L1 |
| 5 | L5₹4.6 Cr+₹1.5 Cr (46.9%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹4.6 Cr+₹1.5 Cr (46.9%) | L5 | Rejected-Finance Not L1 |
Tender Value
₹6.0 Cr
EMD Value
₹6.3 L
Closing Date
20 Sept 2022, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
ADDN / ALTERATION TO EXTERNAL E M SERVICES AT MATHURA UNDER GE(EAST) MATHURA
2022_MES_547267_1
80858
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
MATHURA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE (East) Mathura
₹6.3 L
Yes
1 Oct 2022
24 Aug 2022
22 Sept 2022
24 Aug 2022
20 Sept 2022
15 Sept 2022
Amount
Supply, laying & testing underground cable XLPE insulated, screened PVC bedded galvanised steel strip armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade system of cross section area 400 Sqmm x 3.5 core laid in trenches / duct / fixing on walls / poles or passing through pipe including connecting to installation / equipment / panel with Bus Bar etc with suitable lugs, glands, nuts-bolt & washer complete all as specified and directed .
All as per item No 01 here-in-before but size of cable 300 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 240 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 185 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 150 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 120 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 95 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 70 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 50 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 35 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 25 Sq mm 3.5 core.
All as per item No 01 here-in-before but size of cable 16 Sq mm 4 core.
All as per item No 01 here-in-before but size of cable 10 Sq mm 4 core.
Earth work in excavation in all kind soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed.
Returning, filling in including spreading, levelling,watering and well ramming in any type of soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified & directed.
M&L for clean dry Yamuna sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and levelling complete all as specified and directed. Note : Punned thickness of sand shall only be measured for payment purpose.
M&L for supplying and laying in trenches un-reinforced precast cement concrete cable cover, class LV type 1, flat, size 250mmx150mmx40mm for cable protection cover laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified & directed.
M&L for HDPE Double Wall Corrugated (DWC) pipe of size 40mm outer dia and 32mm inner dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. laid in trenches/ fixed to pole /wall with suitable clamps for cable protection complete all as specified and directed. Make : Gemini/Stiple/Astral
M&L for repairing road cutting with premix ready mix road patching compound including preparing the affected surface by cleaning, sweeping ,brushing and apply cat's coat primer and pouring the ready mix road patching compound, spreading, leveling and compacting to match with existing road complete all as per manufacturers instruction and as directed. Make : Instapatch/ Patch Mate/ Hincol. or equivalent as approved by GE.
Supply, installation, testing and commissioning of outdoor double door type cubicle panel board suitable for 3 phase 4 wire 415 V, 50Hz, and CPRI approved, factory fabricated, powder coating having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof including danger notice plate , PCC 1:2:4 type B-1 as in foundation ,incoming (I/C) and outgoing (O/G) cable connections & general construction confirming to IS: 8623 / 93 comprising of the following: OUTER SHELL: The outer shell shall be made out of 3.15mm thick CRCA steel sheet & MS angle section 50x50x6 mm frame, factory fabricated with front & back open able double door system lockable/ open able by keys from both sides, louvers & air vent gasket for natural flow of air. 'U' type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. INNER SHELL: Inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, the inner shell completely vermin proof & to accommodate incomer/ outgoing MCCBs and TPN Aluminium bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve. All control wires shall be with1.5 sqmm multi strand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled gland plate of thickness 3.15mm powder coated should be used at the bottom. The inner shell shall be of powder coated. The degree of protection for inner shell shall be IP-42 & carry the following:
Supply, installation, testing and commissioning of outdoor double door type cubicle LT feeder pillar box suitable for 3 phase 4 wire 415 V, 50Hz, and CPRI approved, factory fabricated, powder coating having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof including danger notice plate , PCC 1:2:4 type B-1 as in Foundation ,incoming (I/C) and outgoing (O/G) cable connections & general construction confirming to IS: 8623 / 93 comprising of the following: OUTER SHELL: The outer shell shall be made out of 3.15mm thick CRCA steel sheet & MS angle section 50x50x6 mm frame, factory fabricated with front & back openable double door system lockable/ openable by keys from both sides, louvers & air vent gasket for natural flow of air. 'U' type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. INNER SHELL: Inner shell shall be made out of 2.0 mm thick CRCA steel sheet duly compartmentalized for each control gear, the inner shell completely vermin proof & to accommodate incomer/ outgoing MCCBS and TPN Aluminium bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB or 250 Amp which is higher. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve. All control wires shall be with1.5 sqmm multi strand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled gland plate of thickness 3.15mm powder coated should be used at the bottom. The inner shell shall be of powder coated. The degree of protection for inner shell shall be IP-42 & carry the following:
(a) MCCB 100 Amp,4P, 25KA adjustable thermal based released (I/C)- 01 No ( b) MCCB, 63 Amp,16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 02 Nos +02 Bare MCCB space (c.) Aluminium Bus bar (RYB & N) with 4 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 100 Amp,4P, 25KA adjustable thermal based released (I/C)- 01 No ( b) MCCB, 63A,16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 04 Nos (c.)Aluminium Bus bar (RYB &N) with 4 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 160 Amp,4P, 25KA adjustable thermal and adjustable magnetic (I/C)- 01 No ( b) MCCB, 63 Amp, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 04 Nos (c.) Aluminium Bus bar (RYB &N) with 4 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 100 Amp,4P, 25KA adjustable thermal based released (I/C)- 01 No ( b) MCCB, 63 Amps,16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 03 Nos +1 bare space for MCCB (c.) Aluminium Bus bar (RYB &N) with 4 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 125 Amp,4P, 25KA adjustable thermal based released (I/C)- 01 No ( b) MCCB, 63Amp 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 03 Nos +1 bare space for MCCB) (c.) Aluminium Bus bar (RYB &N) with 4 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 200 Amp,4P, 36KA adjustable thermal and adjustable magnetic (I/C)- 01 No ( b) MCCB, 63Amp, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 06 Nos (c.) Aluminium Bus bar (RYB &N) with 6 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 160 Amp,4P, 25KA adjustable thermal and adjustable magnetic (I/C)- 01 No ( b) MCCB, 63Amp 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 06 Nos (c.) Aluminium Bus bar (RYB &N) with 6 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
All as per item No 43 here-in-before but incommer & outgoing as per the following :- (a) MCCB 100 Amp,4P, 25KA adjustable thermal based released (I/C)- 01 No ( b) MCCB, 63 A , 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 05 Nos+01 bare space for MCCB) (c.) Aluminium Bus bar (RYB &N) with 6 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B
Supply & Fixing of Bus Bar Chamber outdoor type made out of 1.6 mm CRCA steel sheet 8 Nos outgoing TPN 200 Amps Bus Bar rating including fixing on Wall / Pole with suitable size of clamp, Nut & Bolt or as per site requirement for fixing of outdoor site with provision of angle iron legs 45 x 45 x 3 mm, 750mm long including PCC 1:2;4 type B-1 as in foundation of size 450 x 600 x600mm for grouting and incommer and outgoing cable connections with suitable size of lugs complete all as specified and directed .
Dismantling / taking down stay assembly complete any type & description.
Dismantling/taking down of ACSR conductor from electric poles of any description.
Dismantling/taking down insulators any type/size from electric poles of any description.
Dismantling/taking down cross-arms and bracing any type/size from electric poles any description.
Dismantling/taking down GI earth wire any type/size from electric poles any description.
Supply & fixing Automatic Security light control panel having sheet steel enclosure powder coated CRCA sheet suitable for three phase,6 KW rating, outdoor installation, IP 54 protected , Slop 1:2 , danger notice plate including making all connections and grouted in PCC (1:2:4) type B-1 as in foundation of size 450 x 600 x 600mm should be 100mm above ground level complete with comprising of the following switch gears:- (i) MCB TPN 40Amp rating -01No (ii) Digital Timer Switch - 01 No (iii) Contactor with nominal current rating 32Amp TP (iv) Outgoing MCB SP with Suitable rating - 03 Nos (v) Auto/manual switch (vi) Incoming and outgoing terminal suitable for three phase supply. (vii) MS cable glands for entry & exist point of cables.
M&L for boring of holes under road, Pavement, Hard standing or as directed by trenchless technology using ultra sounding technique and necessary machine for crossing of LT Electric XLPE cable as per standard technical specification with & including HDPE pipe of dia 150mm suitable for 0.4Mpa working pressure. Vertical depth n. exc. 2 mtr and diameter of hole n. exc. 200mm including getting out excavated surplus soil to a distance not exceeding 50 mtr and depositing where as directed at a level not exc 1.5m above the starting point compllete all as specified and directed.
M&L for earthing of Panel / Busbar etc. complete with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron Wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe medium grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI wire & protection pipe beyond 7.5 Mtr length from earth electrode shall be measured and paid separately. (For Bus Bar 50 Nos Earthing)
M&L for earthing of machinery/equipment/ Panel etc. complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth lead on pole or control board and GI pipe medium grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI strip & protection pipe beyond 7.5 Mtr length from earth electrode shall be measured and paid separately Details : (For Panel 47 Nos (02 for Each) & Feeder Pillar Box 62 Nos (2 for Each) & Timer Panel 40 Nos (1 for Each) Earthing) = (47 x 2 ) + (62 x 2) + (40 x 1) = 258 Nos = 258/2 =129 Set of 2
Supply and fixing moulding compound street light junction box of size not less than 250 mm x 250 mm x 160mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for three phase, four wire cable (size upto 25 Sqmm 4 Core) incomming & outgoing loop -in loop connection and including one No. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete. Make - Sintex or equivalent in Hensel/ABB/PSC.
M&L for Cable route indicator showing " MES LT UG Cable" and route of cable with arrow made of CI in round shape of 100mm dia , 6mm thick and fixed on angle iron 40x40x6mm, 800mm long painted in Blue Colour with two coats of synthetic enamel paint cover a coat of red oxide primer duly embedded in PCC 1:2:4 type B-1 block (0.40x0.40x0.40)mtr in ground and 0.15mtr above ground lable complete all as directed and specified.
Supply & fixing PVC insulated FRLS unsheathed flexible copper conductor cable of size 1.5 Sqmm, multistranded ,three core,1100 volts grade for connecting from loop in - loop out box to street light fitting including heavy duty PVC conduit pipe of size 20mm dia with suitable fixing arrangement on pole with clamps complete all as specified and directed.
Dismantling/ taking down old unserviceable service cable /LT cable/AB cable of any size & any description complete all as directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 35 Sqmm complete all as specified and directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
FRIZO INDIA PVT LTD
M/S SURINDER KUMAR MAHAJAN
GEPS PROJECTS
Pioneer Enterprises
SAGGI ELECTRIC COMPANY
SNG BUILDERS AND ENGINEERS
M/s Matadeen Ramchandra Agarwal
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .