Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC H NO 61 SECTOR 3 SHAKTI NAGAR SHAKTI NAGAR JAMMU JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | ₹2.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.5 Cr+₹20.9 L (9.18%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | ₹2.5 Cr+₹20.9 L (9.18%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹2.8 Cr+₹49.3 L (21.7%)Rejected-Finance | ₹2.8 Cr+₹49.3 L (21.7%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹3.0 Cr+₹68.8 L (30.2%)Rejected-Finance | ₹3.0 Cr+₹68.8 L (30.2%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹3.1 Cr+₹86.2 L (37.8%)Rejected-Finance | ₹3.1 Cr+₹86.2 L (37.8%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹3.0 Cr
EMD Value
₹3.7 L
Closing Date
20 Mar 2024, 6:00 pmClosed
Chief Engineer Lucknow Zone,
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt PIN -226002
PROVISION OF CERTAIN DEFICIENT OTM ACCN OF HQ 71 MTN BDE AT LUCKNOW
2023_MES_624950_2
CELZ/LKO/T-31 OF 2022-23
Open Tender
Construction Works
Lump-sum
540 days
LUCKNOW
AS per tender documents
8 documents required · 8 mandatory
₹2,000
GE(P) LUCKNOW
₹3.7 L
Yes
16 Apr 2024
27 Jan 2024
27 Mar 2024
27 Jan 2024
20 Mar 2024
7 Mar 2024
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path, Culvert & Hard Standing)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (External Water Supply )
Total amount of Sch 'A' Part IX (External Electrification )
Total amount of Sch 'A' Part X (Refrigerator, AC, Water Cooler & Desert Cooler)
Total amount of Sch 'A' Part XI (Conduit for Telephone/TV )
Total amount of Sch 'A' Part XII (Rain Water Harvesting)
Sch 'A' Part - XIII (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S&F angle valve, cast copper alloy, chromium plated with crutch or butterfly handles screwed for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed.
S&F health faucent (1.5 m long tube) with hook (hand spray) with CP body of 15 mm bore & fixed, complete all as specified and directed.
S&F brass chromium plated mixer hot and cold water screwed down for iron pipe and fixed in 15 mm bore complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one modular switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point controlled by two way modular switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp modular switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost..
M&L for Point wiring complete for one 5 Pin 15 Amp modular switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max one points only.
S&F recessed mounted pure line slim square shape LED 44 watt including fixing arrangement connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption 20 W & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats of aluminum paint including nuts, bolts and washers complete all as specified and directed.
S&F LED Lamp 12/14 Watt suitable for batten/angle type holder complete all as specified and directed.
S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 Amp rated bus bar of suit-able size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabri-cated, powder coated complete with out MCCB 4 pole 100 Amp, 16 KA capacity as incoming and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed
Supply and fixing Telephone Scoket Modular with ISI marked complete all as specified and dierected.
Supply and fixing TV Scoket Modular with ISI marked complete all as specified and dierected.
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % without remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed. Note:- (a) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger
Supply and fixing wall mounted fan 400mm sweep with 65 cubic meter/mm air delivery, 1350 RPM , 50 watt in recommended colour with corrosion resistance guard, high quality PP blades for silent operation, copper wound motor tilting control, oscillation knob, tilting control, 120 VAC power cord with polarized plug, oscillation control pull , steel control pull working with 230 VAC with all fittings as per manufacturer norm complete all as specified and directed.
Supply and fixing Exhaust Fan heavy duty plastic body, resistant to colour change 300 mm sweep, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
ROAD, PATH, CULVERT & HARD STANDING M & L for preparing black top surface of road and applying thermo plastic paint on marking of 2.5 mm thick single coat a center line, stop line, side line etc on roads as per IRC pattern. Road marking of not exceeding 100 mm wide using hot mark thermoplastic paint hot application) white or yellow by indineous modem propelled road marking machine as directed including all ingredient such as binder, glass beads, titenium dioxide, calcium carbonate, inter fillets etc. Thermoplastic requirement for glass beads shall be confirming to BS-6086 of MORTH specification including spraying of glass beads etc. as per IRC-35 with and including traffic diversion arrangement complete all as specified and directed.
SEWAGE DISPOSAL Providing, supplying and laying of DWC pipe, Class-SN8 Structured Wall polyethelene Piping systems of 150mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified.
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M dia X 4.50 M effective depth complete all as specified and shown on drawings No. TD-576 Sheet 1/2 & 2/2.
EXTERNAL WATER SUPPLY Dismantling and taking out of GI tubing pipe of any type and size upto 50mm dia including necessary earthwork in any type of soil complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply & fixing LED street light luminaire 70/75 watt, comprising of PDC housing enclosed with toughened glass cover including bracket of 32 mm dia light grade GI tubing 1.20 m long bend to shape with suitable size nut, bolt & washer etc including making cable connection with 3 core PVC insulated copper conductor cable of 1.5 sqmm and ingress protection 66 complete all as specified and directed.
S&F Polycarbonate junction box of size 250x200x150 mm with 01 No SP MCB 6 Amps 02 Nos alumin-ium bus bar of size 25 mmx3 mm for cable in/out fixed on porcelain support with hinged cover and locking arrangement fixed to the PSC/Steel pols by means of suitable size of clamps with nut, bolt and washer with and including locking arrangement fixed to pole complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9.00 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with and including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Disconnecting and taking out old LT under ground cable 1100 Volts of any size and type including necessary earth work in any type of soil complete all as specified and directed.
Relaying of LT under ground cable 1100 Volts of any size and type incluidng necessary earth work in any type of soil complete all as specified and directed.
Supply and fixing MCCB 200 Amp, 4 pole, 50 Hz, 415 Volts with rupturing capacity 35 KA adjustable thermal setting type-01 No with suitable CRCA enclosure complete using lugs glands for cable connection all as specified and directed including following assembly ( for existing Tapping point) :- (a) Ammeter (0 to 500) amp, Digital type having scroll type switch with CT’s.-01Set (b) Voltmeter (0 to 500) V, Digital type scroll type switch-01 Set (c) Indicator lamp LED type (set of 3)-01 Set
4 Nos Aluminium bus bars, 3 Nos for phase (R,Y,B) of rating 300 Amp and 1 for neutral rating 200 amp mounted on heavy duty rubberised / porcelain support.
MCCB 200 Amp, 35 KA, 4 pole , 415V, 50 HZ for incomming-01 No
MCCB 100 Amp, 25 KA, 4 pole , 415V, 50 HZ -02 No (outgoing )
MCCB 63 Amp, 4 Pole, 50 Hz, 415 V, 25 KA - 01 No (Outgoing )
MCB SPN 32 Amp-01 Nos.
Ammeter (0 to 500) amp, Digital type having scroll type switch with CT’s.
Voltmeter (0 to 500) V, Digital type scroll type switch
Indicator lamp LED type (set of 3)
S & F Timer switchs astro type 415 volt three phase 20 Amp rating with suitable size power contactor fitted inside the panel.
Street light Auto ON/OFF switch
LT Danger Notice plate (20cmx15 cm)
Painting as per CPRI
Wiring of panel complete.
Labour charge incling foundation etc.
Note : - The contractor shall arrange factory visit as detailed by accepting officer to check the above panel board.
REFRIGERATOR, AC, WATER COOLAR & DESERT COOLER Supply and installation of metallic body desert cooler electric driven (single phase) having nominal air flow of capacity 4000 cum/hour, including water pipe connection with PVC pipe connection having brass coupling nuts at both ends, PVC float valve, fixing on window complete PVC front grill, regulator, horizontal and vertical adjustable PVC grill and other necessary fittings and electric plug connection with and including plug top 5 Amps complete all as specified and directed.
S&F of Voltage stabilizer of capacity 0.5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input voltage between 170 Volt to 250 Volt with out put voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.
S&F of Voltage stabilizer of capacity 4.0 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input voltage between 170 Volt to 250 Volt with out put voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.
Supply and installation hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and directed
Supply and installation hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2 TR complete all as specified and directed .
RAIN WATRER HARVESTING: M&L for Plain PVC pipe, 152 mm dia bore as per IS 12818 including lowering & jointing complete all as specified and directed.
M&L Screened PVC Pipe 152 mm dia bore as per IS 12818 including lowering & jointing complete all as specified and directed.
M&L for Trial bore of 200 mm dia upto 90 m depth below GL in any kind of Soil strata including hard stone/boulder including electric logging MS Cap., MS flat iron clamps, reducing socket etc complete all as specified and directed.
Reaming of bore upto 300 mm (only for recharge well) pilot bore in any kind of soil/strata including hard stone/boulder by means of direct rotary method upto and including 60 RM depth each below ground level complete all as specified and directed.
M&L for Pea Gravel packing for trial bores of size to be designated by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete as directed.
Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/dirty water complete all as specified and directed.
M&L for PVC end cap for 152 mm bore pipe. complete all as specified and directed.
Supply and laying Plain PVC bend 87.5 degree for 152 mm bore pipe with nylon wiremesh for to covering one end complete all as specified and directed.
R K CONTRACTOR AND SUPPLIERS
Gambhir Constructions
DEORA ELECTRIC WORKS
rajan construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .