Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.8 LAccepted-AOC | 1 | Accepted-AOC Accepted being L1 | |
| 2 | 2₹9.9 L+₹2.0 L (24.8%)Rejected-Finance | 2 | Rejected-Finance Accept | |
| 3 | 3₹10.1 L+₹2.2 L (27.5%)Rejected-Finance | 3 | Rejected-Finance Reject |
Tender Value
₹14.9 L
EMD Value
₹29,880
Closing Date
1 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Leh
GE (AF) Leh c/o 56 APO
CERTAIN PETTY REPAIRS/ MAINTENANCE TO INTERNAL E/M SERVICES IN TORA BORA AND MES ACCOMMODATION AREA AT AF STN LEH
2022_MES_553287_1
GE (AF)-27/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As per tender Dcouments
7 documents required · 7 mandatory
₹500
GE (AF) Leh
₹29,880
Yes
30 Dec 2022
23 Sept 2022
5 Nov 2022
23 Sept 2022
1 Nov 2022
17 Oct 2022
Amount
Point wiring for one light point controlled by one switch one way in & including PVC conduit or casing and capping as per site requirement using FRLS PVC unsheathed multistrand copper conductor cable 1.5 sqmm single core for one light/fan point/bell point controlled by one switch including 3 mm thick plastic laminated sheet cover over PVC / wooden Box for earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly in and including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge. Note : (a) Wiring shall be done by using proper colour coding.
All as per srl item No. 01 here-in-before but for 05 Amp socket outlet on independent board, complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 01 here-in-before but for 05 Amp socket outlet on same board, complete all as specified and directed by Engineer-in-Charge.
All as per item No 1 above but for wall fan/exhaust fan point controlled by one way switch, complete all as specified and directed by Engineer-in-Charge.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly in and including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge. Note : (a) Wiring shall be done by using proper colour coding.
Switch piano, flush type 5 Amps One Way 230 volts, complete all as specified and directed by Engineer-in-Charge.
Socket outlet 2-in-1 3 pin 6 & 16 Amps flush type 230 volts, complete all as specified and directed by Engineer-in-Charge.
Socket outlet 2-in-1 3 pin 6 Amps flush type 230 volts, complete all as specified and directed by Engineer-in-Charge.
Switch one way 15 Amps flush type 230 volts, complete all as specified and directed by Engineer-in-Charge.
Ceiling rose 3 terminal size 50x65mm surface type 230 volts, complete all as specified and directed by Engineer-in-Charge.
Lamp Holder insulated body with back plate for batten fitting suitable for LED lamp, complete all as specified and directed by Engineer-in-Charge.
LED light fitting 1x22 watt T-8, 3.78 ft/4 ft epoxy powder coated CRCA sheet housing with reflector cover channel, prewired with 3 core copper cable of size-23/.0076 from ceiling rost to tube light fitting and tube rod of 22 watt fixed on wall/ ceiling for surfaced pendant mounting in and including taking down of old unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge.
LED Adore Lamp 9/10W, B22 base 6500K CDL type, complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with two single core 2.5 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 2.5 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 2.5 Sqmm ,1 run of PVC casing caping & 1 run of 2.5 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item
Sub main wiring with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC casing caping & 1 run of 4 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring with two single core 6 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 6 Sqmm ,1 run of PVC casing caping & 1 run of 6 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring with two single core 1.50 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 1.50 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 1.50 Sqmm ,1 run of PVC casing caping & 1 run of 1.50 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
MCB SPN, 32 Amps, 240 Volts ,10 KA to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Distribution box Double door type , SPN 8 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coated in and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box Double door type , SPN 4 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coatedin and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box Double door type , TPN 4 way,with required rated bus bar, 415/430 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coated in and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces ,complete all as specified and as directed by Engineer-in- Charge.
MCB TPN, 63 Amps, 415 Volts ,50 Hz ,25 KA to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Blanking plate to cover up the blank area of MCB in DBs, complete all as specified and directed by Engineer-in-Charge.
Energy saving new generation Endura Rugby Neo - IP65, 10W LED IP65 bulkhead luminaire with opal diffuser, etc complete with all accessories rewired electrically connected in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
ENDURA Slim Pro Plus PANEL 36W LED 5700K LED fitting with LED prisumatic optival modular luminaire suitable for Reccesses mounting complete with HF electronic driver in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Moduler switch 1 way 6A, 1 modules square white mechanisms as in replacement, complete all as specified and as directed by Engineer-in- Charge.
Moduler socket 6 Amps, 2/3 Pin combined, 2 module as in replacement, complete all as specified and as directed by Engineer-in- Charge.
Moduler socket 6/16 Amps, 2/3 Pin combined, 2 module as in replacement, complete all as specified and as directed by Engineer-in- Charge.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. in and including taking down of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Taking down exhaust fan of any type for repair including servicing, replacement of painting etc and refixing it to its original position after testing, complete all as specified and directed by Engineer-in-Charge. Note :- Rewinding of exhuast Fan if required shall be carried out separtely under item No-32.00.
Rewinding of exhaust fan of any type or make but of size upto 250mm to 450mm sweep with copper winding wire of required size & type and replacement of bearing, bush and capacitor of required size complete all as required on size and all as directed by Engineer-in-charge.
Decorative garden, pathway light of capacity 10W complete including stand suitable as per OEM with IP65 rated LED Bollard with robust design and efficient light distribution in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Decorative LED Post Top ideal to light up parks, garden and heritage of capacity 20W complete including stand suitable as per OEM with IP65 rated in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Decorative LED Post Top ideal 360 degree indirect light of capacity 40W complete including stand suitable as per OEM with IP65 protection, resistant to impact, anti corrosion, glarefree and better uniformity in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Attending the complaints of electrification nature rectification of the fault as per the complaint lodged by the user onward KWH meter in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, suck boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders, AC, ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty sotres such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as specified and as directed at site to the entire satisfaction by Engineer-in-Charge./users . NOTE : (a) Items replaced shall be measured seprately. (b) All the necessary T&P and transport required for repair shall be provided by the contractor. (c) The complaints of internal electric of one qtr will be considered one Job. (d) The penalty shall be applicable to the contractor if the delay is noticed by Engineer-In Charge more than 12 Hrs after handing over the work of urgent nature to the contractor. (e) Please not that this penalty is exculsively other than conditions 56 IAFW-2249 & shall be treated as interim condition of the contract & Shall inforceable as an delay in individual job is noticed & no cliam whatever on his account shall be entertained by the dept. The decision of the accepting officer in this regard shall be final & binding.
Supply only MCB SPN 32A, 240 V -10 KA complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only MCB SP 6-32A, 240 V -10 KA complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only MCB 32 Amp TPN 415 volts 50 Hz 25 KA, complete with all accessories as required on site & as directed by engineer-in-charge.
Supply only MCB 63 Amp TPN 415 volts 50 Hz 25 KA, complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only Sheet metal enclosure double door for DBs TPN 4 way 415 Volt having 200 A rated bus bar ,complete all as specified and directed by Engineer-in-Charge.
Supply only Lamp Holder insulated body with back plate for batten fitting suitable for LED lamp ,complete all as specified and directed by Engineer-in-Charge.
Supply only Crystal glass LED tube light of 18/20W T8 , 4ft. (double side connection with LED driver) with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light ,complete all as specified and directed by Engineer-in-Charge.
Supply only universal Regal batten for LED tube Double side connection Complete 1x22 Watt ,complete all as specified and directed by Engineer-in-Charge.
Supply only Switch piano, flush type 5 Amps One Way 230 volts complete all as specified.
Supply only Socket outlet 2-in-1 3 pin 6 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination with PVC box 2-in-1 3 pin 6 & 16 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination with PVC box 2-in-1 3 pin 6 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination 2-in-1 3 pin 5 & 15 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination 2-in-1 3 pin 5 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 1.50 sqmm, complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 2.50 sqmm ,complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 4.00 sqmm ,complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 6.00 sqmm ,complete all as specified and directed by Engineer-in-Charge.
Supply only hylem sheet cover 3mm thick of size 4" x 4" ,complete all as specified and directed by Engineer-in-Charge.
Supply only hylem sheet cover 3mm thick of size 6" x 4" ,complete all as specified and directed by Engineer-in-Charge.
Supply only hylem sheet cover 3mm thick of size 8" x 4" ,complete all as specified and directed by Engineer-in-Charge.
Supply only PVC Casing & Caping of size 1.0" (ISI Marked) including all fixing accessories, complete all as specified and directed by Engineer-in-Charge
Supply only PVC Casing & Caping of size 1.5" (ISI Marked) including all fixing accessories ,complete all as specified and directed by Engineer-in-Charge.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
Hitech Engineers
Ms Salaria Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .