28 May 2026, 4:00 pmClosed
Executive Engineer
O/o E. E., D. W. and S. Mech. Div. Dumka
special repairing of installed electromechanical items as pump motor set, motor control panel with FASD starter, voltage stabilizer and other allied works at intake well and WTP of Jaspur group of village rural water supply scheme pertaining to drink
2026_DWSD_114183_1
E-quotation No. 02 2026-27
Open Tender
Machineries/ Mechanical Engg Items
Empanelment
Dumka
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
20 May 2026
20 May 2026
29 May 2026
20 May 2026
28 May 2026
20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Clear water Boosting P/Plant -W.T.P Campus at Kalipahari | |||||
| 1.01 | Cost towards repairing, servicing and overhauling of 10 H.P. HSC C/F Pump set having 1450 rpm, head 40 mtrs, discharge 32 m³/hr, Pump make- Kirloskar DSM type with following works:-
i. Opening, dismantling & cleaning of the pump.
ii. Making, turning & finishing and fitting S.S. pump shaft-01 No. as per sample with threading, key slot making grooving etc. all complete job.-01 No.
iii. S.S. shaft sleeve-02 Nos. as per sample.
iv. Ball bearing -6305 (SKF/NBC make)-02 Nos.
v. Check nut-02 Nos.
vi. M/F Gland tightener as per sample-02 Nos.
vii. Bearing housing re-metalling, turning & finishing as per sample and suitable for bearing.-02 Nos.
viii. Making & fitting of Neck ring-02 Nos.
ix. S.S. bush as per sample-02 Nos.
x. Tyre Coupling set with lathe work-01 set
Complete re-assembling and overhauling of Pump, installing at site with all labour, tools & tackles and Testing on full load with transportation charge up & down etc. including the deduction of scrap materials all complete at clear water P/Plant Kalipahari. | - | Set | - | - |
| 1.02 | Supplying all labor tools and tackles for complete opening, dismantling, cleaning of its slots of stator by brush & petrol then complete rewinding of JSL make 10 H.P, 415 volts, 50c/s,1450 rpm, Star delta, 3 phase induction motor by supplying super enameled copper wire & then tapping, varnishing, heating ,repairing of stator & rotor and reassembling to its original position &testing on full load. Changing of bearings-DE/ NDE 6308/ 6208 as per sample-2 Nos. with including the deduction of cost burnt copper Wires and transportation charges from p/plant to workshop and back to the same etc. all complete at clear water p/plant .
Wt. of cooper wire approx.-8.50 kg. | - | set | - | - |
| 1.03 | Supplying all labor tools and tackles for complete opening, dismantling of JSL make 10 HP, 415 volts, 50c/s,1450 rpm, Star delta, 3 phase induction motor by varnishing, heating, repairing of stator & rotor and reassembling motor to its original position and testing on load etc. all completed at WTP with changing of followings bearings (i) Ball bearing DE/ NDE 6308/ 6208 (SKF) as per sample-1 No. each, terminal plate-01 No. as per sample including the deduction of scrap materials. | - | set | - | - |
| 1.04 | Cost towards repairing, servicing and overhauling of 30 H.P. HSC C/F Pump set having 1460 rpm, head 60 mtrs., discharge 82 m³/hr., Pump make - Kirloskar DSM type with following works:-
i. Opening, dismantling & cleaning of the pump.
ii. Making, turning & finishing and fitting S.S.
Pump shaft-01 No. as per sample with threading,
key slot making grooving etc. all complete job.-01
No.
iii. S.S. shaft sleeve-02 Nos. as per sample.
iv. Ball bearing -6305 (SKF/NBC make)-02 Nos.
v. Check nut-02 Nos.
vi. Gland tightener-02 Nos.
vii. Bearing housing re-metalling, turning & finishing
as per sample and suitable for bearing.-02 Nos.
viii. Making & fitting of Neck ring-02 Nos.
ix. S.S. bush as per sample-02 Nos.
x. Tyre Coupling set with lathe work-01 set.
Complete re-assembling and overhauling of Pump, installing at site with all labour, tools & tackles and Testing on full load with transportation charge up & down etc. including the deduction of scrap materials all complete at clear water P/Plant Kalipahari. | - | Set | - | - |
| 1.05 | Supplying all labor tools and tackles for complete opening, dismantling, cleaning of its slots of stator by brush & petrol then complete rewinding of JSL make 30 H.P, 440 volts, 50c/s, 1460 rpm, Star delta, 3 phase induction motor by supplying super enameled copper wire & then tapping, varnishing, heating and reassembling to its original position repairing of stator & rotor& testing on full load. Changing of bearings- DE/NDE -6310/6310 Make as per sample-2 Nos. with including the deduction the cost of burnt copper Wires and transportation charges from p/plant to workshop and back to the same etc. all complete at clear water p/plant. Wt. of copper wire approx. -22.50 kg | - | Job | - | - |
| 1.06 | Supplying all labor tools and tackles for complete opening, dismantling of JSL make 30 HP, 415 volts, 50c/s, 1460 rpm, Star delta, 3 phase induction motor by varnishing, heating, repairing of stator & rotor and reassembling of motor to its original position and testing on load all completed at WTP with changing of followings bearings (i) Ball bearing DE/ NDE 6310/ 6310 (SKF) as per sample-2 Nos. each, terminal plate-01 No. as per sample including the deduction of scrap materials. | - | Set | - | - |
| 1.07 | Cost towards Resetting of base plate by supplying of new MS base plate as per sample in place of damaged/rusted base plate for 10 & 30 H.P c/f Pump set, groove making, finishing and welding of damaged foundation bolts, pump and motor refitting & alignment, leveling etc., with all labor, tools and materials including the deduction of scrap materials.
I. For 10 HP Pump Motor set- 2 Nos.
II. For 30 HP Pump Motor set- 1Nos. | - | Job | - | - |
| 1.08 | Cost towards repairing & servicing of motor control panel (MCP) having FASD starter – 4 nos. (2 for 10 HP and 2 for 30 HP p/sets) and 200 Amp. 415Volts incomer MCCB with following works-
i. Changing of L&T MNX 50 main contactor with L&K/ Schneider contactor -1 no. with Front- (2NO+2NC) & Side Add on Auxiliary contacts -01 no. each as per suitable for FASD-1(30 HP).
ii. Changing of Star & delta contactor MNX 40& MNX 50- 01 No. each having Front-(2NO+2NC)-1 & Side Add on Auxiliary contacts-(1NO+1NC)- 01no. each with with L&K/Schneider contactor with Front- (2NO+2NC) & Side Add on Auxiliary contacts -01no. each as per suitable –for FASD-2(30 HP).
iii. Changing of star & Delta contactor MNX-25-01 No. each having Front-(2NO+2NC)& Side Add on Auxiliary contact-(1NO+1NC)-01 no. each with L&K/Schneider contactor with Front- (2NO+2NC) & Side Add on Auxiliary contact -01 no. each as per suitable. –for FASD-1.(10 h.p.)
iv. Changing of Thermal overload Relay (30-50 A)-125A max. with required ratings -01 No.
v. Changing Timer (12-120 sec)-01 No. (L&k Make)
vi. ON-OFF push buttons-02 Nos.
vii. 3 Phase LED Voltmeter CI 0.5-01 No.
viii. 3 Phase LED Ampere meter CI 0.5 -01 No.,
ix. Single phasing, reverse current, under voltage, over voltage protection relay (MPD)-02 sets for both motor.
x. LED Phase indicating bulb-06 Nos.,
xi. Auto/Manual Selector switch-03 Nos.
xii. Spare MCCB-100 amp. L&k/Havell’s/BCH /ISI Mark any reputed make.
xiii. S/F of 4 sq. mm Single core copper cable for control wiring etc. with all fitting & electrician and servicing charges at P/Plant. | - | Job | - | - |
| 1.09 | Cost towards Servicing and repairing of 75 KVA Servo voltage stabilizer having input-240-470 volt, Output-400±1% V Power Line make with following works-
i. Cost towards S/F of servo motor as per sample having torque 03 kg-cm to 10kg-cm, 240V,1PH, 50Hz 125mA, 60 RPM with required rating suitable for servo stabilizer - 01No.
ii. Panel Sensing-Control Card-01 No.
iii. Relay,
iv. Digital Voltmeter as sample-01 No. each. ,
v. Control transformer-02 Nos.
vi. Top up T-Oil -60 Ltr.
Including all labor tools tackles and electrician charges etc. all complete job and testing on full load at wtp. | - | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
BOQ_154209.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .