Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.9 L
EMD Value
₹6,000
Closing Date
31 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
DY.C.E(S and D)
Office of The Dy.C.E(M)/(S and D) 5, S.N Banerjee Road, Kolkata-700013, KMC
Necessary replacement of defunct luminaries inside DWF pump house, strainer areas with allied electrical works at DWF station of PBPS(Drg.)/S and D.
2026_KMC_1044307_1
KMC/DR/PBPS/E/24/2026-2027
Open Tender
MISC ELECTRICAL WORKS
Percentage
14 days
6/1 Palmar bazaar road, Kolkata-700015
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹6,000
Office of The Ex. Engr.(M)/PBPS(Drg)/S and D.
7 Oct 2026
7 Oct 2026
2 Nov 2026
8 Oct 2026
31 Oct 2026
8 Oct 2026
8 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. (RATE IN RS. PER MTR), 3 CORE 6 SQ. MM
SHEDULE OF IRRIGATION & WATERWAYS DEPT. 2022 PAGE NO.101, SL. NO. 5.3 | 220 | METER | 125 | ₹27,500 |
| 2 | Laying on Wall / surface with Saddles / clamps.(b)Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting | 90 | RUNNING METER | 60 | ₹5,400 |
| 3 | SUPPLY AND FIXING OF GREENLINE V2 STREET LIGHT(115 WATT) COMPLETE WITH ALL ACCESSORIES TO BE FIXED/PROJECTED FROM THE WALL OF THE BUILDING OR ON
POLE INCL. MAKING HOLES/PROVIDING CLAMPING ARRANGEMENT & NECY. GI REDUCER AS REQUIRED. S&F 40MM GI PIPE (ISI-MEDIUM) QUALITY 1.5 MTS. AVERAGE
LENGTH HAVING SUITABLE BEND S&F NECY. LENGTH OF 1.5 SQMM PVC INSULATED SINGLE CORE STRANDED ANNEALED COPPER WIRE AND MAKING CONNECTIONS AS REQUIRED AND MENDING GOOD DAMAGES TO WALL INCL. PAINTING ETC.
SHEDULE OF IRRIGATION & WATERWAYS DEPT. 2022 PAGE NO.112 ITEM NO. 5.3 F.11.0.1 MAKE : PHILIPS,115 WATT | 12 | EACH | 9,284 | ₹1,11,408 |
| 4 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 16. Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (a) 200 x 150 x 100mm | 8 | EACH | 498 | ₹3,984 |
| 5 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision FOR earthing
attachment .Legrand 2+12 way Enclosure (607712) | 1 | EACH | 1,757 | ₹1,757 |
| 6 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 63 A FP | 1 | EACH | 1,830 | ₹1,830 |
| 7 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP | 8 | EACH | 190 | ₹1,520 |
| 8 | Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp.1. Supplying & Erection of 40x40x6x300 mm long Galv. (HOT Dip) angle iron crossarm FOR carrying insulators incl. painting | 8 | EACH | 304 | ₹2,432 |
| 9 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP. | 8 | EACH | 546 | ₹4,368 |
| 10 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 36/0.3 (2.5 sqmm) | 180 | RUNNING METER | 74 | ₹13,320 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
TENDERFORM.pdf
Tender Documents • 1.28 MB
BOQ_2561511.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .