| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-Finance | L1 | Accepted-Finance Admitted | |
| 2 | L2₹18.9 L+₹3.4 L (22.0%)Accepted-Finance | L2 | Accepted-Finance Admitted | |
| 3 | L3₹22.1 L+₹6.6 L (42.2%)Accepted-Finance | L3 | Accepted-Finance Admitted | |
| 4 | L4₹22.6 L+₹7.1 L (45.6%)Accepted-Finance | L4 | Accepted-Finance Admitted |
Tender Value
Refer Docs
EMD Value
₹35,200
Closing Date
28 May 2021, 6:00 pmClosed
GE (I) CAMPBEL BAY
GE (I) CAMPBEL BAY, ARMY LAND, GREAT NICOBAR-744302
PROVISION OF PUMP AT MOUTH OF EXISTING DRAIN NEAR WATCH TOWER AT MAIN GATE AND ELECTRIC SIREN FOR ATC TOWER AT INS BAAZ CAMPBELL BAY
2021_MES_439345_1
8730/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (I) CAMPBELL BAY
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) CAMPBEL BAY
₹35,200
Yes
2 Jun 2021
30 Apr 2021
31 May 2021
1 May 2021
28 May 2021
3 May 2021
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete as specified and as directed.
Returning, filling in, including spreading, levelling, watering and wall ramming in layers not exc 25 cm in soil all as specified and directed
Removing excavated materials not exc 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply & lay pipe cast iron, S/S including specials Class "LA", 100 mm dia complete all as specified and directed
M & L HDPE Double Wall Corrugated (DWC)pipes,ISI marked,with outer diameter 50 mm and inner diameter 38 mm conforming to IS-14930 Part-II including necessary pipe fittings such as couplers,end caps,bends,clamps etc laid in trenches/on wall for cable protection complete all as specified and directed by Engr-in-charge.
Supply and fix non return Valve, flanged with both ends of class 1.6 PN of size 100mm bore complete including all necessary fittings/fixtures with by-pass arrangement all as specified.Make:- Leader/Upadhyay/Kejarwal.
Supply and Install, testing non clog verticle Submersible pumpset chrome steel impeller & cutter, non clog to pass 40 mm size particluars including installation with guide rail and lifting chain cables earthing testing complete with 2 years maintenance of 7.5 HP with discharge capacity of 600 lpm & head of 40 m complete including all necessary fittings/fixtures all as specified. Make:- Kirloskar/Crompton/Havells
Supply & fix submersible pump starter of capacity 7.5 HP motor complete all as specified. Make:- L & T/Legrand
Supply & lay submersible copper cable of 4 sq mm to connect from motor to stator panel complete all as specified & directed.Make:- Finolex/polycab/Gloster
M&L weather proof sheet metal enclosure double door made up of MS CRCA sheet 3.15 mm thick for housing of Distribution box & starter panel and including stand made up of MS angle iron frame of 50 x 50 mm size on ground with PCC foundation and locking arrangements complete all as specified and directed
Supply & Fix Sheet metal enclosure for DB’s Single pole and neutral, double door 415V, 4 way with 200 Amps rated bus bar complete all as specifed and directed. Make:- L & T/Legrand/Havells
Supply & Fixing MCB TPN 32 Amps, C curve having breaking capacity 10KA complete all as specified. Make:- L & T/Legrand/Havells
Supply & Fixing MCB TP 16 Amps, C curve having breaking capacity 10KA complete all as specified. Make:- L & T/Legrand/Havells
Supply, laying, jointing, testing LT cable 1100 volts grade, XLPE insulated armoured and PVC bedded with stranded aluminium conductor heavy duty, including cable glands, cable lugs etc. to suit the cable size, laid in trenches, fixed along the poles bare or through G.I. Pipe laid under floors road etc; fixed concealed in walls encased in G.I. Pipe etc. complete of size 16 Sq mm,4 core complete all as directed.Make:- polycab/Gloster/Havells
M & L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip of 32x6mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 5 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel 15mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
Material & Labour Fire Alarm sounders / sirens electronic type horizontal double mounting flame proof two stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 mtr with sound output variation of +5 DB for 3500 meter range three phase 415 Volt, 2800 rpm,50Hz,AC, including nuts ,bolts, PCC foundation of size 2x2 M with shed/rain cover for siren protection as per manufacturer instruction complete all as specified and directed by Engr-in-charge.Make:- Kirloskar/CG/or Equivalent approved by GE
Material & Labour weather proof sheet metal enclosure for housing of Siren / Electric Motor incl stand made up of MS channels / angles & PCC foundation for placing the siren / motor panel complete all as specified & directed
Supply and fixing XLPE insulated armoured heavy duty electric cable with alluminium conductor 1100 volt grade of crossection area 10 sqmm, 4 Corecomplete all as specified and directed by Engr-in-charge.
Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 4 x 10.0 Sqmm drawing into and including PVC conduit with accessories, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 2 x 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire completeas directed by Engr in Charge .
S & F MCB DB 4 way ,double door, with 200 amp rated busbar 415 V, TPN recess mounted complete all as specified and directed by Engr-in-charge.Make:- L & T/Legrand/Havells
S&F MCB TPN 63 amps, 25 KA, 415V,'C' series all as specified.Make:- L & T/Legrand/Havells
M/S Sudhir Kumar Gupta
NAVJEEVAN ENTERPRISES
SUBASH FURNITURE SHOP
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .