Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC HOUSE NO 2734 2ND FLOOR PHASE 7 SAS NAGAR MOHALI PUNJAB | S A S NAGAR | PUNJAB | 140103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.1 L+₹40,651.75 (2.59%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹16.0 L
EMD Value
₹31,946
Closing Date
20 Oct 2022, 11:00 amClosed
Er. Nitin Kalia
Executive Engineer Water Supply and Sanitation Division no 2 Jalandhar
Providing and laying jointing fixing testing ISI Marked GI Pipe PVC Pipes Dismantling brick Dismantling of cement concrete 80mm thick cement concrete Sluice Valves Chamber Water Connection on New Proposed PVC Pipe Line and O M for 3 Months complete
2022_WB_90720_1
DWSS-W-DIV14-9894-1
Open Tender
Civil Works - Water Works
Item Rate
60 days
Jalandhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹31,946
31 Oct 2022
30 Sept 2022
20 Oct 2022
30 Sept 2022
20 Oct 2022
30 Sept 2022
Amount
GI Pipe Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B-Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
25mm i/d (on Single side)
40mm i/d (on Both sides)
50 mm i/d (on Both sides)
New Pipe Line Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for less than 3 mtr street width. specifications for Manually Excavation including specials (6kgf/ cm2)
63mm o/d PVC Pipe
90mm o/d PVC Pipe
110mm o/d PVC Pipe
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to original Position.
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects.
PVC/GI Pipe
Sluice Valves Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, (with the approval of Engineer In-charge). Class PN-1 as per ISI
80 mm I/d Sluice Valves flanged
100 mm I/d Sluice Valves flanged
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6m x 0.6m complete in all respect.
Water Connection Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d B- Class ,( Above GL), Prov. & fixing MDPE pipe 15mm i/d with specials (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make .
Water Connection on New Proposed PVC Pipe Line
Water Connection on GI Pipe Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d B- Class as per Above GL), Providing & Fixing in position C.I.bib cock including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp complete in all respect.
Water Connection on Replaced Proposed GI Pipe Line
Water Connection on PVC Pipe Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d ( Below GL), Providing & Fixing in position C.I.bib cock including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp complete in all respect.
Water Connection on Replaced Proposed PVC Pipe Line
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
25mm i/d G.I Union
40mm i/d G.I Union
50mm i/d G.I Union
Connection with existing PVC pipe including cost of PVC tee and PVC saddle piece and earth work in excavation & back filling complete in all respect.
Connection with existing 90mm PVC pipe to GI pipe including cost of CI tee and CI Flanged, elbow, Nut bolt, Union Complete in all respect.
25mm i/d G.I Pipe
40mm i/d G.I Pipe
50mm i/d G.I Pipe
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra.
80mm i/d Non Return Valve Class PN-1.0 as per ISI with gun metal flap
Repair of Water Works
Scraping brushing to remove paint to base metal surface
White washing (Three coat) inside of pump chamber.
Finishing walls with exterior decorative cement based such as snowecem, robbiacem etc. on old work one coat to give an even shade
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade+Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position.panelled, glazed or glazed and panelled.
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area.
Distempering with dry distemper of approved manufacture one coat on old distempered work.
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
CHLORINATION & DISINFECTION Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
SOLAR PANELS Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capacity as per guidelines issued by PEDA complete in all respects.
Carriage of Material such as Bajri & Sand Upto As per site complete in all respect
O. & M. cost for water supply scheme for village Dalla for Sodium Hyprochlorite solution for disinfection cost of solution for 3 Months.
kulwinder singh govt. contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .