Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹53.5 Laccepted-aoc | ₹53.5 L | accepted-aoc |
Tender Value
₹53.5 L
EMD Value
₹1.1 L
Closing Date
17 Feb 2026, 10:30 pmClosed
Rural Drinking Water and Sanitation Department
EXECUTIVE ENGINEER
Augmentation to Chikkabagewadi MVS Water Supply Scheme in Bailhongal Taluka in Belagavi District.(Balance work)
RWSSD/2025-26/WS/WORK_INDENT9836
RWSSD/2025-26/WS/WORK_INDENT9836
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
RWSSD Division Office Belagavi
11 documents required · 11 mandatory
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Satisfactorilycompleted(at least 90% of the contract value), asPrime Contractor atleastonesimilar drinking water supply workofvaluenotlessthan Rs.26.75 Lakhs (certified by an officer not below the rank of Executive Engineer)
Executed in any one year, any three of the following minimum quantities of work1)Pipeline work CI MS DI PVC HDPE GI of at least 1748 mtr length not less than 80 Percenatge of estimated length as per DPR 2) Earthwork excavation of at least 1089 Cum not less than 80 Percentage of estimated volume as per DPR 3)Concrete work of at least 44.86 Cum not less than 80 Percentage of estimated volume as per DPR construction)
Executed in any one year, any three of the following minimum quantities of work1)Pipeline work CI MS DI PVC HDPE GI of at least 1748 mtr length not less than 80 Percenatge of estimated length as per DPR 2) Earthwork excavation of at least 1089 Cum not less than 80 Percentage of estimated volume as per DPR 3)Concrete work of at least 44.86 Cum not less than 80 Percentage of estimated volume as per DPR
The Tenderer should possess valid registration of appropriate Class with PWD Department of Class III and Above
PAN CARD COPY
GST COPY
ACCURATE POSTAL ADDRESS
Unconditional Liquid Assets/Bank Line of Credit from any Nationalized/Scheduled bank of not less than 30% of amount put to tender of Rs.16.04 Lakhs
Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.106.98 Lakhs(usually not less than two times the estimated annual payments under this contrac The Consolidated Annual Financial turnover certificate for the relevant financial years certified by an ICAI registered Chartered Accountant along with UDIN number (also the audited financial statements for each of the financial years to be submitted). The certificate should be affixed with the seal of the office of the Chartered Accountant with the registration number and duly notarized by Notary Public.)
The Tenderer must submit ongoing work commitments (certified by an officer not below the rank of Executive Engineer) to compute available tender capacity
JOINT INSPECTION REPORT ALONGWITH AEE
₹1,340
₹1.1 L
17 Feb 2026
7 Feb 2026
18 Feb 2026
17 Feb 2026
Repairs to approach road & existing Jack well
code01 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel... 45.36 Sqm
code02 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a primi... 2.16 Sqm
code03 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on spec... 4.80 Sqm
code04 Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. O... 16.32 Sqm
code05 Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, ... 249.08 Sqm
code06 Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. includi... 1.00 Nos
code07 Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an an... 7.00 Mtr
code08 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and f... 1.80 Sqm
code09 Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matt... 1000.00 cm
code10 Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work sit... 15.00 Mtr
code11 Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.. complete as per specifications an... 1.00 Set
code12 Providing,Supplying and fixing LT cast iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. ... 60.00 Rmtr
code13 Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size mad... 1.00 Nos
constuction of Panel cum rest room near Jack well
code01 Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and te... 40.82 Cum
code02 Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with ... 7.78 Cum
code03 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS... 2.92 Cum
code04 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixe... 5.13 Cum
code05 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 0.82 Cum
code06 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 4.21 Cum
code07 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 2.75 Cum
code08 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 25.34 Cum
code09 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 0.92 Cum
code10 Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup ... 65.43 Cum
code11 Providing Thermo-Mechanically Treated bars of grade Fe-550 or Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, ... 3.08 Tonne
code12 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) inc... 22.25 Cum
code13 Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing completecomplete as per specifications and as per directions of th... 32.77 Cum
code14 Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with ... 2.59 Cum
code15 Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mix... 45.04 Cum
code16 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, in... 138.18 Sqm
code17 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mor... 119.90 Sqm
code18 Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to open... 90.72 Kg
code19 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a primi... 7.20 Sqm
code20 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on spec... 4.80 Sqm
code21 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and for... 15.84 Sqm
code22 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after th... 158.18 Sqm
code23 Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, ... 121.74 Sqm
code24 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and for... 10.56 Sqm
code25 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning ... 10.56 Sqm
code26 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to... 16.00 Point
code27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to... 3.00 Point
code28 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to... 2.00 Point
code29 Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring us... 6.00 Each
code30 Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. -do- 10"x7"x3" (... 6.00 Each
code31 Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the s... 60.00 Mtr
code32 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS... 60.00 Mtr
code33 Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase ... 6.00 Each
code34 Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ca... 6.00 Each
code35 Supplying and fixing of T5 Fluorescent Tube with 14W power consumption with low 3mg Mercury content & below 40% glass content than T8 lamp & 20% less phosphor coating than T8 with initial lumen on 135... 4.00 Each
code36 Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wire... 4.00 Each
code37 Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of sa... 4.00 Nos
Construction of room & Alum Unit At WTP
code01 Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, inc... 19.44 Cum
code02 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS... 1.35 Cum
code03 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixe... 1.73 Cum
code04 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 0.29 Cum
code05 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50... 0.70 Cum
code06 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The ... 1.17 Cum
code07 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The ... 3.22 Cum
code08 Proving Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C work including straightening , cutiing , bending , placing, in position ,binding and anchoring to adjacent member... 0.71 Tonne
code09 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) inc... 10.43 Cum
code10 Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete complete as per specifications and as per directions of E... 20.41 Cum
code11 Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with ... 1.35 Cum
code12 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS... 0.90 Cum
code13 Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mix... 12.31 Cum
code14 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, in... 42.75 Sqm
code15 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mor... 63.36 Sqm
code16 Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to open... 41.58 Kg
code17 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a primi... 5.94 Sqm
code18 Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel wo... 7.52 Sqm
code19 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after th... 51.75 Sqm
code20 Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, ... 63.36 Sqm
code21 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with cla... 15.00 Mtr
code22 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with cla... 20.00 Mtr
code23 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with cla... 30.00 Mtr
code24 COAGULENT DOSING SYSTEM 65000 LPH Supply, Delivery, Installation and Commissioning of Agitator & Coagulant Dosing System for mldwith required accessories etc. complete for connecting to rising main an... 1.00 Nos
code25 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS... 6.00 Point
code26 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS... 2.00 Point
code27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS... 3.00 Point
code28 Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using... 5.00 Each
code29 Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete complete as per ... 4.00 Each
code30 Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the ... 30.00 Mtr
code31 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS... 30.00 Mtr
code32 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phas... 3.00 Each
code33 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa... 3.00 Each
code34 Supplying and fixing of T5 Fluorescent Tube with 14W power consumption with low 3mg Mercury content & below 40% glass content than TS lamp & 20% less phosphor coating than T8 with initial lumen on 135... 3.00 Each
code35 Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, r... 3.00 Each
code36 Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of sa... 2.00 Nos
Improvement to WTP
code01 Supplying and fixing of solar street light system with mounting and pole (MNES specification) with following specification including cost of transporting to site fixing charges etc. complete.complete ... 7.00 Nos
code02 Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor,Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made... 1.00 Nos
code01 Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,... 148.02 Cum
code02 Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, s... 1148.62 Cum
code03 Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: complete as per specifications and ... 1.63 Cum
code04 Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: complete as per specifications and ... 0.65 Cum
code05 Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: complete as per specifications and ... 1.30 Cum
code06 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint... 340.00 Rmtr
code07 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint... 250.00 Rmtr
code08 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint... 420.00 Rmtr
code09 Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge... 2.00 Nos
code10 Supply and fixing of Cast steel ASTM A 216 Gr.WCB double flanged Dual plate check valve Conforming to API 594 with latest amendments Shaft material shall be SS420/431 and spring shall be spring steel... 2.00 Nos
code11 Supply and fixing of Single / Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/50. ... 3.00 Nos
code12 Supplying and fixing surface box of required dia. and size with synthetic lid for valves or spindle rods. The surface box should be usable for 50 to 400mm dia. valves, PN 10 / 16 and will consist of l... 3.00 Nos
code13 Providing,Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including te... 10.00 Rmtr
code14 Providing,Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including te... 500.00 Rmtr
code15 Providing,Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including te... 350.00 Rmtr
code16 Providing and laying Ductile Iron pipes of class ----- conforming to IS 8329:2000 with latest amendments, conveyiing to worksite, rolling and lowering into trenches, laying true to line, level and per... 315.00 Rmtr
code17 Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5... 1147.32 Cum
code18 Water Bound Macadam Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling ... 1.30 Cum
code19 Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), ... 3.26 Cum
code20 Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and te... 4.37 Cum
code21 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS... 0.32 Cum
code22 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixe... 1.35 Cum
code23 Providing Thermo-Mechanically Treated bars of grade Fe-500D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent member... 81.00 Kg
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Chikka bagewadi KW3 Gen.docx
Tender Document • 0.42 MB
Notification 21.pdf
Others - notification • 1.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .