Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹23.6 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | 1st | Accepted-AOC M/s OM Sai Enterprises is L1 bidder being accepted pl. | |
| 2 | 2nd₹27.9 L+₹2.6 L (10.3%)Rejected-Finance | 2nd | Rejected-Finance Not being L1 | |
| 3 | 3rd₹28.4 L+₹3.2 L (12.5%)Rejected-Finance | 3rd | Rejected-Finance Not being L1 | |
| 4 | 4th₹31.1 L+₹5.8 L (23.1%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | 4th | Rejected-Finance Not being L1 | |
| 5 | 5th₹31.4 L+₹6.2 L (24.5%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | 5th | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Star Electrical L3 | Shri Sai Electricals L5 | S.M.Sales Corporation L2 | ONKAR ELECTRIC AND GENERAL STORE L4 | Om Sai Enterprises L1 | T.H.ASSOCIATES L6 | PREETI ENTERPRISES L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the old transformer oil and testing the TRANSFORMER OIL CLASSIFICATIONS* with the following from NABL accord test lab (i)ACIDITY OR NEUTRALISATION NUMBER(NN) (ii) INTERFACIAL TENSION (IFT).(iii) IFT-NN Relationship and other test complete all as directed. | 9 | Each | 1,500 ₹13,500 | 500 ₹4,500 Lowest | 2,000 ₹18,000 | 2,500 ₹22,500 | 1,500 ₹13,500 | 1,800 ₹16,200 | 2,500 ₹22,500 |
| 2.00 | Disconnections the HT and LT connection 0f 11/0.44 KV step down outdoor type Transformer of capacity 315 KVA and transportation to workshop, Opening the top cover and taking out the core and drain out the unserviceable oil, Descaling the oil tank, removing all sludge and acide cleaning, Removing the all sladge, carbon, acid from the core and coil, dry the coil and heat-varnishing the same, Decarbonizing the all connected parts, Filling new transformar oil, refixing the top cover, top up the transformer oil and dehydration and filteration the oil upto dielectric strength of 30 KV and testing, including painting with two coat of synthetic enamel paint complete including reinstallation in original position and reconnection all as directed.
Note: (i) Cost of M&L for various parts will be paid seperately under respective items of Sch-"A". However, cost of labour towards dismelting, assembling, tools and lifting arrangement, transportation is deemed to be including in this items. Cost of sundry items viz cover bolt, plug cap, screws, washer, air release plug etc., deemed to be included in quoted rate. (ii) New oil to be measured and paid in respective items seperately. (iii) Testing and commissioning of transformer after repair and test report with satisfactory results to be submittted. | 2 | Each | 9,000 ₹18,000 | 7,500 ₹15,000 | 5,500 ₹11,000 | 12,000 ₹24,000 | 2,500 ₹5,000 Lowest | 13,500 ₹27,000 | 25,000 ₹50,000 |
| 3.00 | Serviceaing and maintanence 22/0.44 KV step down outdoor type Transformer of capacity 500 KVA after necessary disconnections the HT connection at site. Opening the top cover and repairing the Leckage, replace the silica gel, Decarbonizing the all connected parts, refixing the top cover, top up the transformer oil and dehydration and filteration the oil upto dielectric strength 30 KV and testing, including painting with two coat of synthetic enamel paint complete all as directed.
Note: (i) Cost of M&L for various parts will be paid seperately under respective items of Sch-"A". However, cost of labour towards dismelting, assembling, Joint inspection and identifying the fault, tools and lifting arrangement, transportation is deemed to be including in this items. Cost of sundry items viz cover bolt, plug cap, screws, washer, air release plug etc., deemed to be included in quoted rate. (ii) Filtration/centrifuging of old transformer oil to be measured and paid seperately. (iii) Addition/Replacement of Transformer oil if required will be measured and paid seperately. (iv) Testing and commissioning of transformer after repair and submitting of test report with satisfactory result to be submittted. | 2 | Each | 8,000 ₹16,000 | 9,000 ₹18,000 | 12,500 ₹25,000 | 8,000 ₹16,000 | 6,000 ₹12,000 Lowest | 9,999 ₹19,998 | 15,000 ₹30,000 |
| 4.00 | All as item no 3 here in before but step down transformer 11/0.44KV of capacity 400 KVA. | 1 | Each | 6,000 ₹6,000 | 9,000 ₹9,000 | 11,000 ₹11,000 | 6,000 ₹6,000 | 5,000 ₹5,000 Lowest | 8,100 ₹8,100 | 12,000 ₹12,000 |
| 5.00 | All as item no 3 here in before but step down transformer 11/0.44KV of capacity 250 KVA. | 3 | Each | 4,500 ₹13,500 | 7,500 ₹22,500 | 9,000 ₹27,000 | 3,500 ₹10,500 Lowest | 4,500 ₹13,500 | 6,300 ₹18,900 | 10,000 ₹30,000 |
| 6.00 | All as item no 3 here in before but step down transformer 11/0.44KV of capacity 160 KVA. | 2 | Each | 3,500 ₹7,000 | 6,500 ₹13,000 | 7,500 ₹15,000 | 3,000 ₹6,000 Lowest | 3,500 ₹7,000 | 5,994 ₹11,988 | 10,000 ₹20,000 |
| 7.00 | All as item no 3 here in before but step down transformer 11/0.44KV of capacity 100 KVA. | 6 | Each | 3,500 ₹21,000 | 6,000 ₹36,000 | 5,200 ₹31,200 | 2,000 ₹12,000 Lowest | 2,500 ₹15,000 | 5,400 ₹32,400 | 10,000 ₹60,000 |
| 8.00 | All as item no 3 here in before but step down transformer 11/0.44KV of capacity 50 to 75 KVA. | 2 | Each | 3,000 ₹6,000 | 5,500 ₹11,000 | 4,500 ₹9,000 | 1,500 ₹3,000 Lowest | 2,000 ₹4,000 | 5,400 ₹10,800 | 8,000 ₹16,000 |
| 9.00 | Supply only breather assembly of approved make filled with silica gel suitable for transformer of capacity upto 500 KVA Volt Distribution transformer. | 13 | Each | 1,200 ₹15,600 | 300 ₹3,900 Lowest | 600 ₹7,800 | 3,500 ₹45,500 | 520 ₹6,760 | 5,400 ₹70,200 | 5,000 ₹65,000 |
| 10.00 | Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 250 KVA to 500KVA. | 3 | Each | 600 ₹1,800 Lowest | 1,250 ₹3,750 | 1,600 ₹4,800 | 3,200 ₹9,600 | 1,000 ₹3,000 | 6,300 ₹18,900 | 5,000 ₹15,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Vinay Kumar, IDSE, SE (SAG), CWE
HQ Commander Works Engineer (Army) Mumbai 24 Assaye Building Colaba Mumbai -05
REPAIR AND MAINT OF HT DISTRIBUTION, UNDERGROUND HT CABLE HT EQUIPMENTS, TRANSFORMER AND ALLIED WORKS UNDER GE DEHU ROAD
2025_MES_735961_1
85223/DR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehu Road Pune
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
GE DEHU ROAD PUNE
₹90,000
Yes
21 Jan 2026
17 Oct 2025
10 Nov 2025
17 Oct 2025
8 Nov 2025
1 Nov 2025
Amount
Taking down the old transformer oil and testing the TRANSFORMER OIL CLASSIFICATIONS* with the following from NABL accord test lab (i)ACIDITY OR NEUTRALISATION NUMBER(NN) (ii) INTERFACIAL TENSION (IFT).(iii) IFT-NN Relationship and other test complete all as directed.
Disconnections the HT and LT connection 0f 11/0.44 KV step down outdoor type Transformer of capacity 315 KVA and transportation to workshop, Opening the top cover and taking out the core and drain out the unserviceable oil, Descaling the oil tank, removing all sludge and acide cleaning, Removing the all sladge, carbon, acid from the core and coil, dry the coil and heat-varnishing the same, Decarbonizing the all connected parts, Filling new transformar oil, refixing the top cover, top up the transformer oil and dehydration and filteration the oil upto dielectric strength of 30 KV and testing, including painting with two coat of synthetic enamel paint complete including reinstallation in original position and reconnection all as directed. Note: (i) Cost of M&L for various parts will be paid seperately under respective items of Sch-"A". However, cost of labour towards dismelting, assembling, tools and lifting arrangement, transportation is deemed to be including in this items. Cost of sundry items viz cover bolt, plug cap, screws, washer, air release plug etc., deemed to be included in quoted rate. (ii) New oil to be measured and paid in respective items seperately. (iii) Testing and commissioning of transformer after repair and test report with satisfactory results to be submittted.
Serviceaing and maintanence 22/0.44 KV step down outdoor type Transformer of capacity 500 KVA after necessary disconnections the HT connection at site. Opening the top cover and repairing the Leckage, replace the silica gel, Decarbonizing the all connected parts, refixing the top cover, top up the transformer oil and dehydration and filteration the oil upto dielectric strength 30 KV and testing, including painting with two coat of synthetic enamel paint complete all as directed. Note: (i) Cost of M&L for various parts will be paid seperately under respective items of Sch-"A". However, cost of labour towards dismelting, assembling, Joint inspection and identifying the fault, tools and lifting arrangement, transportation is deemed to be including in this items. Cost of sundry items viz cover bolt, plug cap, screws, washer, air release plug etc., deemed to be included in quoted rate. (ii) Filtration/centrifuging of old transformer oil to be measured and paid seperately. (iii) Addition/Replacement of Transformer oil if required will be measured and paid seperately. (iv) Testing and commissioning of transformer after repair and submitting of test report with satisfactory result to be submittted.
All as item no 3 here in before but step down transformer 11/0.44KV of capacity 400 KVA.
All as item no 3 here in before but step down transformer 11/0.44KV of capacity 250 KVA.
All as item no 3 here in before but step down transformer 11/0.44KV of capacity 160 KVA.
All as item no 3 here in before but step down transformer 11/0.44KV of capacity 100 KVA.
All as item no 3 here in before but step down transformer 11/0.44KV of capacity 50 to 75 KVA.
Supply only breather assembly of approved make filled with silica gel suitable for transformer of capacity upto 500 KVA Volt Distribution transformer.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 250 KVA to 500KVA.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 100 KVA to 160KVA.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 50 KVA to 75 KVA.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 250 KVA to 500KVA.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 100 KVA to 160KVA.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 50 KVA to 75 KVA.
Supply only ceramic bushing and Gasket on LT side of transformer of capacitie 250 KVA to 500 KVA 22/11/0.44 KV Distribution transformer.
Supply only ceramic bushing and Gasket on LT side of transformer of capacitie 50 KVA to 160 KVA 11/0.44 KV Distribution transformer.
Supply only ceramic bushing and Gasket on HT side of transformer of capacitie 250 KVA to 500 KVA 22/11/0.44 KV Distribution transformer.
Supply only ceramic bushing and Gasket on HT side of transformer of capacitie 50 KVA to 160 KVA 11/0.44 KV Distribution transformer.
Supply and fixing in replacement of complete gasket (Cock sheet) 6 mm thick complete of capacity of 250Kva to 500 Kva transformer including conical rubber bush:-
Supply and fixing in replacement of complete gasket (Cock sheet) 6 mm thick complete of capacity of 50 KVA to 160 KVA transformer including conical rubber bush:-
M&L for on load filtration/configuration/desludging(in situ) of old carbonized insulating oil(Transformer Oil), filled in transformers under service(Both the power and distribution type) of various capacities and rating outdoor type(22/11KV,22/0.44KV,11/0.44 KV) located and installed at different places under GE Dehu Road area by means of filtration plant(Machine), electric motor driven to improve the dielectric strength up to 66 KV including filling/topping up insulating oil and mentaining data of fil on transformer. Note:(i) Testing of di-electric strength of insulating oil befor and after filtration shall be carried out in presence of e-in charge/GE.(ii) T&P /Labour required for filtration testing shall be arranged by the contractor at his own cost.(iii)New Transformer oil topped shall be measured and paid seperately.
Supply Transformer oil in pack container complet all as directed
Disconnecting all in coming and outgoing cables, removing the transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractor's workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and out going cables by properly crimping using lugs of suitable size taping the bushes / bus bars, using insulation tape and testing complete of capacity up to 500 kva all as directed . Note:- (i) Rate including allinsulating material for winding coil (ii)Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side , rewinding,dehydration of oil shall be measured and paid separately in respective items.(iii)Testing of Transformer in workshop complet.
Supply and winding of 22/11//0.433 KVHV coils,using new copper wire/strip of proper size injcluding insulating materials (double insulation)as per existing size of core of transformer complete incl heating , varnishing all as directed .
Supply and winding of 22/11//0.433 KV LV coils,using new copper wire/strip of proper size injcluding insulating materials (double insulation)as per existing size of core of transformer complete incl heating , varnishing all as directed .
Surface excavation n.exc 30cm deep and averaing 27 cm deep and getting in hard and dence soil.
Excavation in trenchesin Soft / loose soil not exc 1.5m wide and not exc 1.5 m in depth for laying cable,erection of poles,stay and pipe line,complete allas directed.
Excavation in trenches for errection of poles etc.,n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
M & L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
M&L for applying two coats of Synthetic enamel (Ordinary tint)over a coat of primer Surfaces of any description steel surface, over 10cm in width or girth,not otherwise described.
Supply and laying stone gravells(river stone) of size 20mm to 30 mm for spreading,leavling is surrending transformer all as direted.
Taking up the un reinforced precast concrete cable cover of any type from the existing trenches.
Supply and laying un reinforced precast concrete cable cover class HT, type-I, flat size 300 mm x 180 mm x 40 mm laid in trenches.
Laying only un reinforced precast concrete cable cover as obtained from item no 5 here n before of class HT, type-I, flat size 300 mm x 180 mm x 40 mm laid in trenches.
Supply, spreading in trenches sand cushioning with dry and cleover and under the cable for protection of cable,complete all as directed (Punned thickness shall be measured for payment)Note: Thickness of sand cushioning shall be measured after punning and consolidating of sand.
Taking out old unserviceable underground cable HT/LT,PVC insulated, PVC sheathed armored heavy duty aluminum conductor form pole, wall and trenches etc after disconnecting complet all as directed.
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 95 sq. mm. Note- some place ACSR conductor will be schedule of credit.
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 70 sq. mm. Note- some place ACSR conductor will be schedule of credit.
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 120 sq. mm. Note- some place ACSR conductor will be schedule of credit.
Relaying HT cable 11000/22000 volt grade of any size any type as obtaing from item no-40 here in before all as directed.
Reaying GI pipe medium grade 80 mm dia for protection of cable all as directed.
Reaying GI pipe medium grade 100 mm dia for protection of cable all as directed.
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm sqmm
Taking down unserviceable Aluminium cable lug 120/185 sqmm and supply with fixing the same all as directed.
Taking down unserviceable Aluminium cable lug 95 sqmm and supply with fixing the same all as directed.
Taking down unserviceable Aluminium cable lug 70 sqmm and supply with fixing the same all as directed.
Supply & Erect Steel sewaged tubular poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified of type 410 SP-55 (11.0 Mtrs Long) including Painting with two coats of aluminium paint over a coat of red oxide primer complete after preparation of steel surfaces and writing letters / Numbers not more than 10 cm high by Black paint all as directed.. .
Taking down unserviceable danger notic board,Supply and FixingDanger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, forHT, 25x20cm size
M&L for earthing complete with galvanised Steel earth plate electrode of size 600x600x6mm thick burried directly in ground with (earth pit not less than 2.25mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire of size 4.0 mm dia by means of nuts, bolts, check nuts, washers of galvanised Iron or Steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion all complete.
Supply and fix earth strip of size 25 x 4 mm galvanised iron strip fixed to wall/over head reservoir on batten or recess or chases or buried inground or drawn in conduit /pipe fixed on poles insulated as per Engr-in-Charge.
Dismantling and removing ACSR conductor of any type from pole after disconnecting all connection on insulator etc all as directed.
Supply & fixing ACSR conductor of any type and Size incl binding, on insulator all as directed
Restringing/Fxing only ACSR conductor of any type and Size incl binding wire, retrived all as directed
Dismantling cross arms of MS channel or angle iron section etc complete and setting aside for reuse/replacement with in 50 mtr all as directed.
Supply and fix cross arms, bracing, support, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including one primer coat, one under coat and one finishing coat all as directed.
Fixing only retrieved serviceable cross arms, bracing, support, clamps ,retrived all as directed.
Dismantling the insulators of any type/size/voltage.Testing with magar and keeping aside serviceable insulator for refixing all as directed.Note: Refixing/Replacement of new items measured and paid in respective seperate items.
Supply and fix pin type insulator, Polymetric/poreceline , vitreous, white/brown including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 150 mm height 150 mm dia 11000 volt grade all as specified.
Fixing only serviceable pin type insulator, pin type insulator any type and size obtained.
Supply and fix disc type insulator Polymetric/ poreceline vitreous,/Polymetric 145 mm height and 255 mm dia ball and socket type white/brown of 11000 volt grad all as specified .
Fixing only serviceable disc type insulator any type and size, obtained.
Taking down unserviceable GOD,and supply and fixing Triple pole, mechanically operated mounted on insulator and steel frame, with operating mechanisum worked from ground level GOD 11 KV heavy duty, for current rating 400 amps all as directed.
Indicator LED Lamp,(Read,Yellow,and Orange)110 V,AC,for HT 11 KV VCB.
Closing Coil,110V,DC,suitable for HT 11 KV VCBD82:D107 Make
Shunt trip coil on,24V ,DC,suitable for HT 11 KV VCB Make
Control Fuse ,HRC,2/4/6 Amp,suitable for HT 11 KV VCB Make
Motor cutoff switch,suitable for HT 11 KV VCB Make
HT Tape
Monoplast Tape
Digital volt meter 96x96mm,0-500V,Aux supply 110V,AC,suitable for HT 11 KV VCB.
Digital Ammeter Make - Conzerve DM - 3258 /DM 3310 suitable for HT 11 K V VCB
Auxilary switch on block magnet,suitable for HT 11 KV VCB Make
Male & Femal Spout assembly,suitable for HT 11 KV VCB Make
CT for VCB,suitable for HT 11 KV VCB Make
Over Current realy suitable for HT 11 KV VCB.
Master trip relay suitable for HT 11 K V VCB.
Digital VAF meter , EM 6400 suitable for HT 11 K V VCB
Contact arm assembly from HT 11 kV VCB suitable for Siemens braker
M & L to find out fault location in 11000 V /415 V UG Cable of any size by using cable fault locator directed by all as specified and directed by Eng in charge. Note:-Contractor must bring cable fault locator at site within 24 hours of intimation otherwise recovery @ Rs 1000/Hr will be charged after 24 hours.
Comprehensive maintanence and repair of brackdown for 11 HT overhead / UG cable / UG cable line from MRS to Garden city (Gardencity feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -15 KM)
Comprehensive maintanence and repair of brackdown for 11 HT overhead / UG cable line from MRS to 29 FAD(Center feeder) under GE Dehu road all as directed.(Noted: Length of feeder approx -24KM)
Comprehensive maintanence and repair of brackdown for 11 HT overhead / UG cable line from MRS to Ashok nagar, COD(Ashok nagar feeder ) under GE Dehuroad all as directed.(Noted: Length of feeder approx -15 KM)
Comprehensive maintanence and repair of brackdown for 11 HT overhead / UG cable/Under Ground line from MRS to Kehinya Pump house, COD (Keniya feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -9 KM)
Comprehensive maintanence and repair of brackdown for 11 HT Under Ground line from MRS to Kehinya Pump house MAP Qtr (MAP feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -4.5 KM)
Comprehensive maintanence and repair of brackdown for 22 HT overhead / UG cable line from MRS to147 unit location(Unit 147 feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -8 KM)
Comprehensive maintanence and repair of brackdown for 22 HT overhead / UG cable line from MRS to ODTD unit location ( DOD feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -15 KM)
Comprehensive maintanence and repair of brackdown for 22 HT overhead / UG cable line from MRS to Indrayani location, 495 unit ( Indrayni feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -11 KM)
Note for item Nos 91 to 98 The scope of work inclusvie of :- (a) To identify reasion for HT line brackdown. (b) Immediat repair the HT line. (c) replace the unserviceable material. The material for repair HT line will be measured and paid seperately in respective items of shedule "A". (d)Providing safty equiptment for maintanence staff. (e) Insurance of maintanence staff will be provided by the contractor. (f) The maintanence/serviceabilty of HT VCB completed immediately any fault occured at any time.
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight throuht heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 - 95 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight throuht heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 -185 sqmm sqmm
S.M.Sales Corporation (BID ID -3469107)
Star Electrical (BID ID -3466548)
ONKAR ELECTRIC AND GENERAL STORE (BID ID -3470332)
Shri Sai Electricals (BID ID -3467937)
T.H.ASSOCIATES (BID ID -3469967)
PREETI ENTERPRISES (BID ID -3469949)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_824098.xls
BOQ • 0.31 MB
Tenderdocuments85223.pdf
Tender Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .