Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC 84 ARYA NAGAR SARDHANA ROAD KANKER KHERA MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹24.1 L+₹29,877.87 (1.26%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹25.3 L+₹1.5 L (6.31%)Rejected-Finance 56 LALKURTI BARA BAZAR MEERUT CANTT UP 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹25.9 L+₹2.1 L (8.83%)Rejected-Finance 355 2 LAL SINGH NAGAR SHIV SAROVAR BANK COLONY GARH ROAD MEERUT UP | MEERUT | UTTAR PRADESH | 250002 | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹26.8 L+₹3.0 L (12.4%)Rejected-Finance NOT SPECIFIED | L5 | Rejected-Finance Rejected due to not being L1 |
Tender Value
₹49.0 L
EMD Value
₹97,960
Closing Date
4 Jul 2024, 6:00 pmClosed
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt The Mall Road Meerut Cantt Distt Meerut-250001(UP)
SPL REPAIR OF BLDG NO E-20 OR LINES) OF 22 RAPID (S) SIG REGT (AREN), PROVN OF FALSE CEILING AND PVC PANELING OF SAND MODEL ROOM OF HQ 22 ARTY BDE CAMP, PROVN OF LIGHTENING CONDUCTORS IN BLDG NO E-57 OF 22 RSR AND ADDN/ALTN TO SINGLE OFFR ACCN QTR NO
2024_MES_658177_1
GE/MRT/S/8155/2024-2025
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹97,960
Yes
14 Oct 2024
6 Jun 2024
11 Jul 2024
6 Jun 2024
4 Jul 2024
20 Jun 2024
Amount
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc complete all as specified and directed
M&L brick work with sub class fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified and directed
M&L brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified and directed
Dismantling timber scantlings 40 sq. cm and over in section as in framed work, in any position as in roof truss and Purlins complete all as specified and directed
S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats et conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed
Dismantling asbestos cement (corrugated or semi corrugated ) sheets in roof covering complete all as specified and directed.
Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed.
Supply and fix Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed.
S&F Mild steel flat iron as in wind ties including cutting drilling holes and securing bolts confirming to FE 410-0 of 310-0 complete all as Specified and Directed.
Dismantling ceiling board of insulation boards etc any thickness complete all as specified and directed.
Material & labour for provision of Aluminium anodized frame work(snap grid) suitable for size as in false ceiling of size 605mmx605mm consisting of followings and all as directed:-i) Aluminium sections incorporated in frame work shall conform to designation 63400 given in IS: 737-1986. ii) The snap grid shall consist of aluminium anodized main /cross tee of size 36.5mmx25mmx1.4mm thick and 25mm x 25m x1.4mm thick, respectively. iii) Snap grid frame shall be fixed to ceiling with supporting hangers consisting of S & F 2mm dia mild steel GI wire. iv) The main and cross tees shall be jointed at junction/crossings with aluminium anodized angle bracket, of size 15mmx15mmx1.4mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer’s instructions. v) The snap grid (main/cross tee section) shall be supported at ends all along the wall with aluminium anodized angle of size 25mmx25mmx1.4 mm anodized thick. vi) Size of the snap grid shall be 605mm by 605mm. vii) Minimum average thickness of anodizing shall be 15 micron.
S&F 4 mm thick Gypsum/Everest Board in ceiling size 60cm x 60cm fixed to aluminium snap gird complete as per manufcturer"s instructions complete all as specified and directed
Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed
S&F Coloured Glazed colour ceramic tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 10mm thick plaster in CM(1:4) joint free with grout of matching shade complete all as specified and directed
M &L for Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, white tiles, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M &L for Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, white tiles, on vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and laid over and including 10mm thick screed bed in CM 1:4 complete all as specified and directed.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each complete all as specified and directed
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqn each complete all as specified and directed
Supply & fixing pressed steel frames for doors with one or more rebates including necessary fitting lugs, hinges, lock strike plates etc completed size of frame 125x60mm made out of 1.25mm MS sheets complete all as specified & directed.
S&F for factory made 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed
M&L gauged shutter shall be made out of box section 35x35x5mm, 25x25x5mm and 1.5mm thick as shown on drawing. The frame for shutter shall be of pressed steel and 10mm Square bars grill complete with fly proof wire mesh having 0.63mm nominal dia wire and 1.4mm average with aperture including two coats of synthetic enamel paint over a coat of red oxide Primer complete all as specified and directed
S&F Aluminium, anodized barrel tower bolts of extruded section and fixed, 200 mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified and directed
S&F aluminium anodized handle of size 150 mm, ISI marked, complete all as specified and directed
S&F aluminium alloy, anodised, sliding door bolt 250mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed ISI marked complete all as specified and directed
S&F Steel windows box type using 'P' section comprising double frame for gauge and glazed skelton shutter jointly with flat iron 40x3mm complete including hinges, handle, tower bolts, stops, lugs etc all as shown on drawing.Note (i) For the perpose of measurement & payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mongreries shown on drgs (iii) gaurd bars glazing & Wire mesh shall be measured and paid for separately complete all as specified and directed.
Supply & fix galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified & directed.
S&F 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading ) in square n.exc 0.5 Sqm in each panes complete all as specified and directed.
M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290 Gde-165 complete all as specified and directed.
Taking down of cement plaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed.
M & L 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth with out using extra cement complete all as specified & directed.
Materials & labour for prepration of newely plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over and including one Coat of Cement Primer of, any colour, complete all as specified & directed.
Materials & labour for prepration of Old plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over one Coat of Cement Primer complete all as specified & directed.
M&L Preparing newly plaster surfaces & applying two coats of cement base paint Complete all as specified and directed.
M&L preparation of old painted surfaces and applying two coat of cement based paint on walls of any colour complete all as specified and directed.
M & L For preparation of New or Previously untreated Wooden Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and directed.
M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel Paint over one coat of Red oxide primer complete all as specified and directed
Demolition of cement concrete of ground floor n exc 15 cm in depth in any position nototherwise specifically provided for, complete all as specified and directed
M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cement complete all as specified and directed
Dismantling OH water tank of capacity exc 500 ltr but not exceeding 1000 ltr and removing from site complete all as specified and directed
S&F triple layer 1000 Ltrs Rotational moulded polyethylene (PVC) water storage tanks cylindrical vertical with closed top including nipple nuts and washers for fixing inlet, outlet/washout pipes and air vent pipes complete all as specified and directed
Taking up or down steel tubing and connection 15 mm bore pipe and removing from site complete all as specified and directed
Taking up or down steel tubing and connection 20 mm bore pipe and removing from site complete all as specified and directed
Supply, fix 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
Supply, fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
S&F sinks made of stainless steel 01mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing with Granite Stone and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed
Supply & fix PVC ball valves, high pressure with polyethylene float and fly nut complete screwed for iron pipe 20mm bore complete all as specified & directed.
S&F Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed for 20 mm pipe complete all as specified and directed
S&F Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed for 15 mm pipe complete all as specified and directed
Supply and fixing PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
Supply & fixing steel C.P. grating 100/125 mm dia as reqd at site complete all as specified and directed
S&F in repair bib taps brass cromium plated 15 mm bore size screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed
M&L PCC 1:3:6 type C-0 (using 12.5 mm greded agg) for hold fast pressed steel frame etc complete all as specified and directed
Material & Labour Powder coated anodised aluminium partition with/without sash bar, aluminium section weighing 0.55 kg/Mtr (minimum) including necessary joining cleats, Glazing clips, rubber packing aluminum snap beading, screws suitable anodised aluminium frame with one or more rebates including 5 to 6 mm thick glass all fixed to frame glass complete all as specified and directed.
Material & Labour For Powder coated anodised aluminium Door Shutter without sash bar, aluminium section weighing 0.55 kg/Mtr (minimum) including necessary joining cleats, Handles, hydraulic door closer Locking Arrangement , Glazing clips, rubber packing anodised aluminum snap beading, screws suitable anodised aluminium frame with one or more rebates including supply and fix 5 to 6 mm thick black glass all and aluminium grill fixed to frame complete all as specified and directed.
M&L Non Skid ceramic ( coloured tiles ) tiles 7 to 8 mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, (400 x 400 x 10mm) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed or bedding layer in C M 1:6, for laying floor finish complete all as specified and directed
Dismantling OH water tank of capacity exc 250 ltr but not exceeding 500 ltr and removing from site complete all as specified and directed
Supply & fix rotational moulded polyethylene water storage tanks 500 liters capacity, triple layered (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings complete all as specified & directed.
M & L RCC 1:2:4 Type B1 nominal mix ( Using 20 mm graded stone Aggregate ) as in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
S&F mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing clips complete all as specified and directed.
M & L For Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete complete all as specified and directed
M & L For Granite (of any type) tiles 15 to 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types laid over and including Screed bed or bedding layer 15 mm thick in C M 1:6, for laying floor finish Complete all as specified an directed.
Supply and fix in repairs 75mm bore PVC Pipes single socketed in any length with rubber ring joints, fixed to walls and floor etc. as in waste complete all as specified & directed.
Supply and fix PVC bends 75mm bore, any radius complete all as specified & directed
S&F in repair ,PVC(SWR) floor trap, 75mm bore, plain with grating including jointing with solvent cement complete all as specified and directed
S&F 15mm dia chromium plated fancy type sink mixer with swinging spout (wall mounted model) fixing and connection to pipes complete all as specified and as directed.
Supply and fixing 06mm thick hollow insulated PVC wall lining consisting of PVC insulated panels having expended polystyrene (EPS) fitting into the wall by using nail, pvc strips, L, angles etc. complete all as specified and directed.
Material & labour for provision of GI frame work (snap grid) suitable for size as in false ceiling of size 605mmx605mm including fixing 12 mm Perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm in size, fixed to GI snap grid in ceiling consisting of following and all as directed (i) Gi sections incorporated in frame work shall conform to designation given in IS: 737-1986. (ii) The snap grid shall conist of GI frame work main/cross tee of size 36.5mmx25mmx1.0mm thick and 25mmx25mmx1.00mm respectively. (iii) Snap grid frame shall be fixed to ceiling with supporting hangers consisting of Supply and fix 2mm to 4mm dia mild steel Gi wire. (iv) The main and cross tees shall be jointed at junction/crossings with GI frame work angle bracket, of size 15mmx15mmx1.0mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer's instructions. (v) The snap grid(main/cross tee section) shall be supported at ends all along the wall with Gi frame work angle of size 25mmx25mmx1.00mm anodized thick (vi) Size of the snap grid shall be 605mmx605mm. (vii) Minimum average thickness of anodizing shall be 15 micron. complete all as specified & directed.
Supply and fixing LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with highefficiency PMMA diffusersoftglare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 12 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified and directed
Supply and fixing MCB SPN, AC, 240 volts of 63 Amps, C curve, 10 kA complete all as specified and directed
Material and labour for sub main wiring with 10 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor and including continuous earth wire of size 10 Sqmm nominal cross sectional area and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade. Note:- One meter of 25mm dia non-metallic PVC conduit alongwith 2x10 Sqmm and 1x10 Sqmm earth wire shall be measured as one unit lenght.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed
Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed.
Material and labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, unsheathed, copper conductor cable in and including new PVC concealed conduit of any size/dia complete with all accessories/fittings, brass screws, washer etc, sunk zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth duly complete all as specified and directed for One light point controlled by one, one way switch 05 / 06 Amps.
One fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed
One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch complete all as specified and directed
One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch complete all as specified and directed
All as per serial item No 79.00 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board complete all as specified and directed
Supply and fix in repair switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
Supply and fix in repair socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed.
Supply & fixing in repair of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed.
Supply and fix in repair switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
Supply and fixing in repair steped type electronic fan regulator flush type on the existing sheet etc. AC, 230 volts, duly ISI marked with and including connector complete all as specified & directed.
Supply & fixing in repair lamp holder (Angular / Straight), insulated body, with back plate for batten fitting including 9 watt LED Bulb complete all as specified and directed
Supply and fix decorative LED Tube light fitting 1x20 Watt , with opal diffuser, environmental friendly, energy efficient MS batten with retrofit T8 polycarbonate tube-01 No, complete with all accessories and fixing material complete all as specified and directed
Supply and installed LED security light fitting 1x60 Watt luminaries with GI bracket including taking down existing old security light fittings with pressure die cast aluminium housing comprising high power LEDs enclosed with lens embedded PC cover with LED driver complete IP 65 protection complete all as specified and directed
Material and labour in repair for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note:- One meter of 25mm dia non-metallic PVC conduit alongwith 2x04 Sqmm and 1x04 Sqmm earth wire shall be measured and paid separately.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified and directed
Supply and fixing MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed.
Supply & fixing MCB, DP (Double Pole), AC, 240 volts, B series capacity 40 Amps to 63 Amps 10kA and making connections complete all as specified & directed.
Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified & directed.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified and directed
Supply and fix LED lamp 10 watt complete all as specified and directed
Material & labour for earthing complete with copper earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI strip 25x4mm means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around copper earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
M & L for Aluminium strip of size 25 x 3.15 mm for earth continuity from test point to Air termination rods inter connections including brazing for joint, copper/brass nut bolts/washers with insulators for necessary fixed on wall/laid on roofs/trenches etc complete all as specified and directed
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Supply and fixing of Aluminium Air termination, single pointed aluminium rod 12mm dia and 300mm long a proper distance as per direction of EIC incl all cutting/welding complete all as specified and directed
Supply and fixing in repair LED security light fitting 1x45 Watt luminaries with die cast aluminium housing comprising epoxy powder coated enclosed with glass coverembedded lens in frame with high power LED white lamp type of capacity 45 watt complete all as specified and directed.
Supply and fixing sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision for four pole isolator/mcb as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified and directed.
Taking out old unserviceable LT cable any size and supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 10 sqmm 2 core armoured, PVC sheated with aluminium conductor heavy duty laid in tranchies, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed.
Supply / laying and fixing 80 mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M depth in soft/ loose soil and getting out in soft / loose soil complete all as specified and directed
M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading leveling andhar punning complete all as specified and directed.
M&L for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft / loose soil complete all as specified and directed
Removing surplus excavated materials not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed
Meterial and labour for cement concrete in foundation, filling and mass concrete type C-2 of ratio 1:3:6 complete all as specified and directed.
Supply and fix LT OH lines on existing poles with ACSR conductors size 2 of 6/2x2.59mm (weasel) complete all as specified and directed.
SA construction co.
M/S AGARWAL CONSTRUCTION CO.
B.K.construction
M/S AMAR ELEKTRO CENTRE
Rajneesh Jain
vibha associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .