Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.1 L+₹64,175 (3.48%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹23.4 L
EMD Value
₹46,800
Closing Date
9 Feb 2023, 6:00 pmClosed
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE(I)(AF)/SHL/ OF 2022-23 REPAIR/REPLACEMENT OF OLD/UNSERVICEABLE
2023_MES_574127_1
8066/22/SHL/2022/23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LAITKOR PEAK SHILLONG
For Enlisted Contractors Class E Category b i and for unenlisted contractors meeting enlistment criteria for required Class and Category
8 documents required · 8 mandatory
₹500
GE (I) (AF) SHILLONG
₹46,800
Yes
15 Feb 2023
10 Jan 2023
11 Feb 2023
10 Jan 2023
9 Feb 2023
23 Jan 2023
10 Jan 2023 - 20 Jan 2023
Amount
Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same.
Taking down carefully old point wiring (light, Fan, Socket, bell point or power point) complete including unserviceable fittings and fixtures like switches, Sockets, holders, ceiling roses bulk head fittings/fixtures removing from site and keeping serviceable fittings/ fixtures etc in safe custody for re-use at site (if found serviceable) and making good disturbed surfaces of wall/floor with cement plaster in cement mortar (1:6) and distempering/ white wash to match the existing surface complete all as directed by Engr-in-Charge.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper cable FRLS-H of size 1.5 Sqmm 1100 Volts grade drawing into and incl PVC conduit of size 20mm bore and cutting chasing in wall for concealed wiring with all accessories and one single core PVC insulated sheathed multi stranded copper cable of size 1.5 sqmm, 1100 Volts grade as earth continuity conductor connected to common earth dolly termination switch board of recessed MS box / box 1.6mm thick covered with PVC laminated sheet 3mm thick with brass screw for mounting switches, sockets etc complete as specified and directed for the following:-
(a) One light/ Fan point controlled by one switch complete.
(b) One socket out let 5A 5pin on independent board complete.
(c) One call bell controlled by one bell push complete.
(d) One socket out let 5A 5pin on same board complete.
All as per item no 2 here-in-before but with two single core PVC insulated unsheathed multistranded copper cable 2.5 sqmm and one single core 2.5 sqmm copper cable as earth continuity conductor for one 15 Amp power point on independent board all as directed.
All as per item no 2 here-in-before but with two single core PVC insulated unsheathed multistranded copper cable 4.0 sqmm and one single core 4.0 sqmm copper cable as earth continuity conductor for one 15 Amp power point for geyser on independent board all as directed.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper cable FRLS-H of size 1.5 Sqmm 1100 Volts grade and incl PVC casing & caping of size 20 / 25 mm fixing in wall with all accessories and one single core PVC insulated unsheathed multi stranded copper cable of size 1.5 sqmm, 1100 Volts grade as earth continuity conductor connected to common earth dolly termination switch board of recessed MS box 1.6mm thick covered with PVC laminated sheet 3mm thick with brass screw for mounting switches, sockets etc complete as specified and directed for the following:-
(a) One light/ Fan point controlled by one switch complete.
(b) One socket out let 5A 5pin on independent board complete.
(c) One call bell controlled by one bell push complete.
(d) One socket out let 5A 5pin on same board complete.
All as per item no 5 here-in-before but with two single core PVC insulated sheathed multistranded copper cable 2.5 sqmm and one single core 2.5 sqmm copper cable for one 15 Amp power point on independent board all as directed.
All as per item no 5 here-in-before but with two single core PVC insulated sheathed multistranded copper cable 4 sqmm and one single core 4 sqmm copper cable for one 15 Amp power point/geyser point on independent board all as directed.
M & L for switch piano, flush type single pole, one way 5 Amp.
S & F Bell push, flush type, 5 amp 230 volts.
S & F Bell Ding dong type suitable for AC, 230 V, 50 Hz supply.
S&F switch socket combination 5/6 Amp, 240 Volts, 5pin, 2-In-1 flush type universal complete all as directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal all as specified and directed.
S & F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one MCB SP 10 Amps for geyser complete all as directed.
S & F ceiling rose surface bakelite, three terminal AC, 230 Volts complete all as specified and directed . .
S & F switch piano, flush type, single pole one way, 15 Amp for geyser complete all as specified and directed . .
S & F Batten angle holder backelite, insulated body with LED bulb 10W, AC, 230V complete all as directed.
S & F batten LED luminaire integrated LED channel with engineering plastic batten and white acrlic cover 18 Watt suitable for AC, 230 volts supply. Make Havells Cat No BS18WLED865SPCSS or equivalent as approved.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS-H cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor FRLS-H cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through rigid non metallic PVC conduit of suitable size on roof/wall/ceiling including making groove in any type of wall etc (concealed type)including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge. Note: Two run of 6sqmm single core cable and one run of earth wire with PVC conduit and accessories shall be measured as unit length.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS-H cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor FRLS-H cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through and including casing and caping of suitable size roof/wall/ceiling including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge. Note: Two run of 6sqmm single core cable and one run of earth wire with caping casing and accessories shall be measured as unit length.
S&F in replacement sheet metal enclosure DB’s SPN Double Door 8 way with 100 amps rated bus bar, AC, 240 volt on the wall/recessed complete all as specified & directed including taking down old. Make : C&S or equivalent as approved.
S&F in replacement sheet metal enclosure DB’s TPN Double Door 6 way, AC, 415 volts on the wall/recessed complete all as specified & directed including taking down old. Make : C&S or equivalent as approved.
S&F in replacement MCB SPN 20 to 40 Amp suitable for 240 Volt, AC, 50 Hz supply complete all as directed. Make : C&S or equivalent as approved.
S&F in replacement MCB SP 6 to 40 Amp suitable for 240 Volt, AC, 50 Hz supply complete all as directed. Make : C&S or equivalent as approved.
S&F in replacement MCCB TPN 415Volt, 4 pole, 18 KA, 63 to 100 Amp complete all as specified and directed including taking down old. Make : C&S or equivalent as approved.
S&F in replacement MCCB TPN 415Volt, 4 pole, 18 KA, 125 Amp complete all as specified and directed including taking down old. Make : C&S or equivalent as approved.
S & F in replacement SKYLUX efficient LED recessed mounting 2 X 2 luminaire suitable for AC, 230 volts, 50 Hz supply, white powder coated CRCA housing with LEDs, seamless front frame with flat white high transmission acrylic cover complete with driver and prewired for necessary connection incl taking down old unsv fluorescent fitting from ceiling all as directed. Make-Havells, cat No.HE2X2R36WLED857PIRSENSOR or equivalent as approved.
S & F in replacement SKYLUX efficient LED recessed mounting 1 X 1 luminaire suitable for AC, 230 volts, 50 Hz supply, white powder coated CRCA housing with LEDs, seamless front frame with flat white high transmission acrylic cover complete with driver and prewired for necessary connection incl taking down old unsv fluoroscent fitting from ceiling all as directed. Make-Havells, Cat No. PLUTO1X1PLR15WLED857S or equivalent as approved.
S & F in replacement SLEEK RD LED recessed mounting round downlight luminaire 15 watt suitable for AC, 230 volts, 50 Hz supply, aluminium die cast cast body finish with drop down PC diffuser complete with driver and prewired for necessary connection incl taking down old unsv fluorescent downlight from ceiling all as directed. Make-Havells, Cat No. RDDLR15WLED857S or equivalent as approved.
Supply only following Modular accessories :-
(a) Modular socket outlet 2/3 pin, 6 and 16 amp 2 module complete.
(b) Modular switch way 16A, 1 module complete.
(c) Modular socket outlet 2/3 pin, 6 amp 2 module complete
(d) Modular switch way 6A, 1 module complete.
(e) Modular bell push way 6A, 1 module complete.
(f) T8 Tube light (rod) with LED tubelight (rod) 20w Single side connection with inbuilt driver suitable for AC, 230 volts, 50 Hz.. Make-Havells, Cat No T8SSTL20WLED865SPC, cool white or equivalent as approved.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in any type of soil with provision of charcoal and salt. PCC 1 : 2: 4 type B1 in chamber with RCC 1 : 2 : 4 type B1 for cover slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways and with 6 mm dia MS hook complete including taking down old unsv earthing all as specified and directed.
M/S DEEDAR ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .