Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 32 06 PEST HOUSE NARONA CHAURAHA MALL ROAD POST BOX NO 49 KANPUR 208001 UP | KANPUR | KANPUR | UP | 208001 | ₹1.0 Cr | L1 | Accepted-AOC Being reasonable and Lowest L1 |
| 2 | L2₹1.1 Cr+₹4.3 L (4.15%)Rejected-Finance | ₹1.1 Cr+₹4.3 L (4.15%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.1 Cr+₹6.4 L (6.13%)Rejected-Finance | ₹1.1 Cr+₹6.4 L (6.13%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹1.1 Cr+₹7.2 L (6.85%)Rejected-Finance | ₹1.1 Cr+₹7.2 L (6.85%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹1.1 Cr+₹10.1 L (9.66%)Rejected-Finance | ₹1.1 Cr+₹10.1 L (9.66%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
31 Aug 2020, 6:00 pmClosed
Col SS BOse CWE
HQ CWE (AF) Chakeri Kanpur-208008
ADDN ALTN TO HANGER NO 4 AND ITS ANNEXIE OF 29 ED AT AFS KANPUR
2020_MES_352035_1
82120/E8
Open Tender
Civil Works
Lump-sum
366 days
Chakeri, Kanpur
Class B cat a (i)
8 documents required · 8 mandatory
₹1,000
GE (AF) B/R Chakeri
₹2.2 L
6 Nov 2020
11 Jun 2020
7 Sept 2020
11 Jun 2020
31 Aug 2020
3 Aug 2020
Amount
Lumpsum price worked out by the contractor for"BUILDING &STRUCTURES”as listed in Sch ‘A' Part I representing above/below the lump sum price of Rs 21,50,000.00 as inserted by MES for Sch ‘A’ Part I on Sl. Page No.18(R).
Lumpsum price worked out by the contractor for “ADDITION / ALTERATION” as listed in Sch ‘A' part II representing above / below the lumpsum price of Rs. 36,51,459.07 as inserted by MES for Sch ‘A’ Part II on Sl. Page No.25.
Lumpsum price worked out by the contractor for“INTERNAL ELECTRIFICATION ” as listed inSch ‘A' Part III representing above / below the lump sum price of Rs 36,512.40 as inserted by MES for Sch ‘A’ Part III on Sl Page No.27
Lumpsum price worked out by the contractor for 'INTERNAL WATER SUPPLY ' as listed in Sch ‘A' Part IV repersenting above/below the lump sum price of Rs 22,440.40 as inserted by MES for Sch ‘A’ Part IV on Sl Page No 28 .
Lumpsum price worked out by the contractor for 'EXTERNAL ELECTRIFICATION ' as listed in Sch ‘A' Part V repersenting above/below the lump sum price of Rs 3,584.26 as inserted by MES for Sch ‘A’ Part V on Sl Page No 29 .
Lumpsum price worked out by the contractor for 'EXTERNAL WATER SUPPLY ' as listed in Sch ‘A' Part VI repersenting above/below the lump sum price of Rs 66,371.90 as inserted by MES for Sch ‘A’ Part VI on Sl Page No 30 .
Lumpsum price worked out by the contractor for 'EXTERNAL SEWAGE DISPOSAL ' as listed in Sch ‘A' Part VII repersenting above/below the lump sum price of Rs 26,313.98 as inserted by MES for Sch ‘A’ Part VII on Sl Page No 32 .
Lumpsum price worked out by the contractor for 'SITE CLEARANCE, EXCAVATION & EARTHWORK ' as listed in Sch ‘A' Part VIII repersenting above/below the lump sum price of Rs 44,444.93 as inserted by MES for Sch ‘A’ Part VIII on Sl Page No 33 .
SCH 'A' PART -IX (MISC E&M AND B/R ITEMS) S&F Nylon wire bird proof netting of HDPE twine of 1.00mm dia and having mesh size 25mm x 25mm square or diamond type black UV stablized including supporting of all mesh netting by 10mm dia nylon rope by steel hooks of suitable size and other required fixing arrangments as in ceiling on existing trusses of hangers complete all as per manufacturer's instructions, specified & directed. Note:- Unit rate quoted by the contractor shall also include the following elements:- (a) Fixing & installation of wire netting with nylon rope and by other means as directed by Engr-in-charge/GE and shall be got done from manufacturer's team as per authorised firm handling netting solutions of skilled workers as per manufacturer's instructions all as specified and directed. (b) Provision of requisite necessary scafolding as well as other works nature i.e civil welding etc required to execute/ complete the work shall be provided by the contractor. please also note that scaffolding provided shall be of requisite strength/design to avoid any mishappening/accident. Any compansation on account of any accident/mishappening/damage occured shall be paid by the contractor as per rules and regulations of labour contract act or any other similar staturatory rule applicable. (c) Contractor shall arrange all safety measures for workers to avoid any mishappening during execution of work and also covered all workers with insurance. (d) The work has been executed at Hanger roof ceiling and no any extra payment shall be made by Govt for extra height. Contractor may quoted their rate as per site conditions with considering all above aspects.
M&L 16mm thick of size 600 x 600 mm mineral fibre false ceiling sytem of pattern classic lite RH 99 (bevelled tegular) of Armstrong or equivalent make and model including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15mm x 38mm size (load carring capacity 14 Kg/Sqm) spaced at 1200mm centres securely fixed to the structrucal soffit and flush fitting 1200mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600mm module cut sub cross tee/runner 600 mm required independent support. Wall angle of size 19mm x 19mm secured to the periphery of the wall at 450mm maximum centres. The above grid is suspened at every 1200mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 4mm dia aqauline wire and adjuster with suitable fasteners and hook clip complete all as specified and directed.
S&F coloured galvalume profile sheet in roofing shall be with feed material manufactured from 0.50 mm (minimum) base metal thickness (BMT), minimum 550 MPa yield strength and shall confirm to physical specifications of ASTM-792 or equivalent. colour coated galvalume sheet shall have maximum pitch of 250 mm C/C and minimum 28 mm crest depth in length as per site requirement. The steel sheet shall be coated with hot dip metallic Aluminium Zinc alloy (55% Aluminiumm, 43.5% Zinc, 1.5% silicon) coating AZ 150 as 150 gm/Sq. mt total on both sides. The contractor shall submit manufacturer test certificates for the chemical and mechanical properties, confirming genuinity of materials including base metal thickness paint thickness and AZ 150 coating thickness must be submitted for approval to GE prior to the installation / fixing. The manufacturer of sheet should submit related documents for expected product service performance of pre painted metal sheet as per relevant ASTM/ IS. Manufacturer‟s recommended installation methodology shall be adopted for installation of roofing including profiled sheet, capping, trims, flashings, gutter and all types of accessories considered for roofing. Fastener shall be used for fixing roofing system as per manufacturer‟s recommendation. The painting shall be coloured based enamel super durable polyester with silicon coating of film thickness of minimum 25 micron (including primer) on top and minimum 10 micron (including primer) on interior face. The paint shall be of shade as approved by GE. The sheet shall have wide pans with minimum 2 (TWO) small stiffening ribs for effective water shedding and special male/ female ends with full return legs on laps for purlin support and fixed with self-driling screws as per manufacturers instructions completed all as specified and directed. Note : Total thickness of sheet with BMT , AZ 150 coating and painting shall be minimum 0.575 mm thick. If 0.575 mm thickness sheet is not available in market then next higher thickness of sheet shall be applicable without any price adjustment.
S&F UPVC sliding 2 track window of wall thickness 1.2mm + 0.25 mm made out of extruded section plain UPVC sections. The window frame made out of rigid UPVC sections meter cut at 4 corners & joint with plastic fusion welding with internal reinforcement required. The shutter section made out of extruded rigid UPVC with internal reinforced with provision of glazing/stainless steel wire mesh as per requirement. the window shall be fixed to the wall using 65x 100 mm long MS fasterners at suitable place provided for each vertical and horizontal member etc complete as per manufacturer's instruction of Make: Rajshri or equivalent
S&F UPVC sliding 3 track window of wall thickness 1.2mm + 0.25mm made out of extruded section plain UPVC sections. The window frame made out of rigid UPVC sections meter cut at 4 corners & joint with plastic fusion welding with internal reinforcement required. he shutter section made out of extruded rigid UPVC with internal reinforced with provision of 5mm glazing /wiremesh as per requirement. the window shall be fixed to the wall using 65x 100 mm long MS fasterners at suitable place provided for each vertical and horizontal member etc complete as per manufacturer's instruction of meke Rajshree or equivalent
INTERNAL ELECTRIFCATION M & L concealed point wiring on wall and surface wiring on ceiling/roof/trusses with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multistranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid metallic MS conduit 16 SWG ISI marked not less than 20mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly covered with bakelite laminated sheet 3mm thick, ISI marked for mounting of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper multistrand conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the distrubed surfaces by filling cement mortar (1:3) and matching, finishing of new plastered surfaces by means of plaster of peris (POP) and Birla white care putty and applying two coat of oil bound distemper / colour wash with same existing shed / colour complete all as specified and directed for the following :- (a) One light /fan point, controlled by one, one way switch
(b) All as per item No 14 here-in-before but for one 5/6 Amp socket point controlled by one switch on independent board.
(c) All as per item No 14 here-in-before but for one 5/6 Amp socket point controlled by other switch on same board.
(c) All as per item No 14 here-in-before but for for power point wiring 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable and 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable as continous earth lead. Note : All points will be made in hangers/Annexie.
S&F ceiling fan 1200 mm sweep 5 star rating complete with down rod and accessories (without regulator) and electrical connections with 3 core coppper cable 1.5mm sqmm from ceiling rose to fan complete all as sspecified and directed. (Make- HAVELLS Model PACER or equivalent in other makes given in Appendix 'B' duly approved by GE).
S & F factory made epoxy powder coated Distribution Board SPN 8ways ( SPN MCCB DB ) with metal door ( IP-43 protection ) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with Knockouts and suitable for one SPN-MCB 6-32 Amp as incomer and 6 SP MCBs as outgoing fixed properly in concealed position complete all as specified and conforming to IS : 8623 complete all as specified & directed. (Make: Legrand cat part No 507611 or equivalent in other makes given in Appendix 'B' duly approved by GE.)
S & F factory made epoxy powder coated Distribution Board TP & N 4ways ( TPN MCB DB ) with metal door ( IP-43 protection ) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with Knockouts and suitable for one FP-MCB 40/63 as incomer and 15 SP/SPN/TPN MCB's outgoings fixed properly in concealed position complete all as specified and conforming to IS : 8623 complete all as specified & directed. (Make: Legrand cat part No 507745 or equivalent in other makes given in Appendix 'B' duly approved by GE.)
S & F on Distibution Boards, Single pole (SP) MCB 6/10/16/25/32 Amps, 240 Volt, 50 Hz, AC made from moulded self-extingushing thermostat plastic and suitable for 'C' curve, 10 KA breaking capacity and terminal box suitable for 10 Sqmm cable complete conforming to IS 8828 of 1996 complete all as specified & directed. (Make : Legrand Cat Part 408587, 408590, 408592, 408593, 408594 and 408595 or equivalent in other makes as given in Appendix 'B' duly approved by GE).
All as per item No 18 here-in-before but SPN 06 to 32 Amps (Make : Legrand Cat Part 408609 to 408617 or equivalent in other makes as given in Appendix 'B' duly approved by GE).
S & F on Distibution Boards, TPN MCB 20-32 Amps, 240 Volt, 50 Hz, AC made from moulded self-extingushing thermostat plastic and suitable for 'C' curve, 10 KA breaking capacity and terminal box suitable for 10 Sqmm cable complete conforming to IS 8828 of 1996 complete all as specified & directed. (Make : Legrand Cat Part 408678 and 408680 or equvialent in other makes as given in Appendix 'B' duly approved by GE).
S & F on Distibution Boards, TPN MCB 40-63 Amps, 240 Volt, 50 Hz, AC made from moulded self-extingushing thermostat plastic and suitable for 'C' curve, 10 KA breaking capacity and terminal box suitable for 10 Sqmm cable complete conforming to IS 8828 of 1996 complete all as specified & directed. (Make : Legrand Cat Part 408681 and 408683 or equvialent as given in Appendix 'B' duly approved by GE.
S & F on Distibution Boards, TP MCB 20-32 Amps, 240 Volt, 50 Hz, AC made from moulded self-extingushing thermostat plastic and suitable for 'C' curve, 10 KA breaking capacity and terminal box suitable for 10 Sqmm cable complete conforming to IS 8828 of 1996 complete all as specified & directed. (Make : Legrand Cat Part 408656 and 408658 or equvialent in other makes as given in Appendix 'B' duly approved by GE).
S & F on Distibution Boards, TP MCB 40-63 Amps, 240 Volt, 50 Hz, AC made from moulded self-extingushing thermostat plastic and suitable for 'C' curve, 10 KA breaking capacity and terminal box suitable for 10 Sqmm cable complete conforming to IS 8828 of 1996 complete all as specified & directed. (Make : Legrand Cat Part 408659 and 408661 or equvialent as given in Appendix 'B' duly approved by GE.
M&L sub main wiring with two runs of single core PVC - FRLS 6.0Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable 1100 volts grade, drawn in and including rigid metallic MS conduit 16SWG ISI marked medium grade not less than 25mm dia including all necessary fittings and accessories such as tee, bends, reducers, elbow, bell mouth, tube ends and all fitting accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed porperly on as in concealed position on wall and surface position on ceiling (roof/trusses including cutting chases) and including one run of PVC insulated and unsheathed single core PVC -FRLS cable with copper conductor of size 4.0 Sqmm as earth wire (green in colour ) run through MS rigid conduit and connected to common earth dolly , including making good disturbed surfaces to match with existing surfaces complete all as specified and directed. Note: Two run of 6 sqmm single core cable and one run of 4.0 sqmm single core earth copper conductor and one run of MS conduit will be measured and paid as one unit length.
M&L sub main wiring with four runs of single core PVC - FRLS 10 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable 1100 volts grade, drawn in and including rigid metallic MS conduit 16SWG ISI marked medium grade not less than 32mm dia including all necessary fittings and accessories such as tee, bends, reducers, elbow, bell mouth, tube ends and all fitting accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed porperly on as in concealed position on wall and surface position on ceiling (roof/trusses including cutting chases) and including one run of PVC insulated and unsheathed single core PVC -FRLS cable with copper conductor of size 6 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring and making good disturbed surfaces to match with existing surfaces complete all as specified and directed. Note: Four run of 10sqmm single core cable and one run of 6.0 sqmm single core earth copper conductor and one run of MS conduit will be measured and paid as one unit length.
M&L Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation and earth work, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick, reinforced with 8 mm dia TMT bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh, watering GI pipe of 20 mm dia 'medium grade' and lugs including Charcoal dust, salt and testing etc. complete all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification. Note : Earthing lead and protection pipe upto 7.5 metre length shall be deemed to be included in the quoted unit rate, beyand 7.5 metre shall be measured and paid for separately. (6+0)
M&L cutting/boring under PCC / WBM / hard standing at depth not more than 30 cm depth & 20 in width and making good disturbed surfaces (cutting area) with top 10 cm filled with PCC (1:2:4) type B-1 using 20mm graded stone aggregate and bottom 20cm filled with hard core crushed stone aggregate 40 to 30mm size complete all as specified and directed. (100+80)
S&F sheet metal enclosure, 32 Amp, single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with and including one single pole neutral MCB 32 Amp fixed properly on in concealed position complete all as specified and directed. (Make: Legrand cat no 607851 or equivelent in other makes as given in Appendix 'B' duly approved by GE).
Supply and fix in replacement recessed type 35/40 watt LED with Lumen output of 3400 Lumen with epoxy polyster powder coated CRCA sheet complete with electronic driver etc prewired all accessories and connected with copper wire suitable size & length including hanging arrangements complete all as directed and as specified. Make: Philips Cat No. RCB 380B LED 36S-4000 G4 L60 W60 PSD OD WH OC or equivalent in other makes as given in Appendix 'B' duly approved by GE.
M&L wall mounted three speed oscillating type fan of size 400 mm sweep 900 RPM single phase with in built regulator fixed properly on wall by provisioning of MS strips, nut, bolts, washers and connecting complete all as specified and directed. Make Havells cat No. V-2 or equivalent in in other makes given in Appendix 'B' duly approved by GE.
S&F metallic body Heavy duty exhaust fans AC single phase 230/ 240 V of size 450 mmsweep, 900 RPM complete with louvers & shutters all as specified and directed. Make- Havells Model No Turbo Force HS or equivalent in other makes given in Appendix 'B' duly approved by GE.(07 +04)
AC/REFRIGERATION WORK Supply and fixing of automatic voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 150V to 285 V with outpur voltage at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed. (Make: V Gaurd or Amron or Luminious or equivelent in other makes as given in Appendix 'B' duly approved by GE).
S&F sheet metal enclosure, 20 Amp, single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with and including one single pole neutral MCB 20 Amp fixed properly on in concealed position complete all as specified and directed. (Make: Legrand cat no 607843 or equivelent in other makes as given in Appendix 'B' duly approved by GE).
M&L sub main wiring with two runs of single core PVC - FRLS 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable 1100 volts grade, drawn in and including 20mm dia MS, medium grade, ISI marked conduit with all necessary fittings and accessories and including one run of PVC insulated and unsheathed single core PVC -FRLS cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through Mild steel conduit and connected to common earth dolly , including conealing in position on wall surface position of truss and making good distrubed surfaces to match with existing surfaces complete all as specified and directed. Note: Two run of 4 sqmm single core cable and one run of 4 sqmm single core earth copper conductor and one run of MS conduit will be measured and paid as one unit length.
Supply & fix MCB SP, 20 Amps , 240 volts, 50 Hz, AC for 'C' curve, 10 KA breaking capacity fixed in existing MCB DB complete all as specified and directed. (Make: Legrand cat No 40 8593 or equivalent n other makes as given in Appendix 'B' duly approved by GE).
M&L fabrication of airconditioner cage made out of MS angle iron of size 40mm x 40mm x 5mm welded steel wire fabric on four sides for housing of condensing unit and shed on top made out of 20 gauge PGI sheet and applying two coats of synthetic enamel paint (black) over a coat of red oxide primer complete all as specified and directed.
Supply and installation, commissioning and testing of hi wall split type AC of capacity 1.5 TR with following specification:- (a) Indoor Unit: The split air conditioners suitable for 230V, 50Hz single phase AC supply shall be capable of performing the functions as cooling, dehumidifying, air circulating and filtering and having BEE3 star rating /making as pecified. The air conditioners provided with electronic thermostat as per IS: 11338 : 1985. (ii) Out Door Unit : Out door unit of the air conditioners shall be fitted with discharge cooled type rotary/scroll type compressor, operating on non-CFC refrigerant R-410A with suitable rated capacitor start electric motor. it shall be equipped with overload protection and shall be mounted on resilient mountings for quiet operation. (iii) Remote cordless control with LCD/LED display shall be provided, Display shall be provided as per manufacturer design Make- Model No RAU318KVDB of HITACHI or equivalent from CARRIER/BLUE STAR/LLOYED
EXTERNAL ELECTRIFICATION Supply, laying, jointing, testing and commissioning in trenches, ducts or fixing in wall or passing through pipe, XLPE cable, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120 sqmm 3.5 core suitable for earthed system complete all as specified & directed.
Supply, laying, jointing, testing and commissioning in trenches, ducts or fixing in wall or passing through pipe, XLPE cable, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 sqmm 3.5 core suitable for earthed system complete all as specified & directed.
M&L cutting/boring under PCC / WBM / hard standing not more than 30 cm deep & 20 cm in width and shall be make good by filling with PCC (1:3:6) type C-1 using 20mm graded stone aggregate with old and new stone aggregate including removal of excavated rubbish / old material out side MD land complete all as specified and directed.
M&L making horizontal boring by drilling / boring machine 60 cm deep below road crossing for passing of LT cable in GI pipe complete all as specified and directed.
M&L earthing complete with galvanised steet earth electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 1.65 mtr deep below normal ground level) with top edge of earth electrode not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm as earth lead by means of bolt, check nuts & washer of GI or steel connected to earth test point including earth strip from earth electrode to test point, Gl pipe 40 mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoal dust, common, salt, excavation and earth work, earth pit with PCC 1:3:6 type C 1 using 20mm graded stone aggregate, precast RCC cover 40mm thickness reinforced with 03 Nos TMT bars, 8 mm dia, both ways, funnel with wire mesh, testing and rest as shown in electrical plate No 3 of SSR Part -I including taking out old earthing material, complete all as specified and directed.
SAXENA BANDHU
B.K.ASSOCIATES
M/s R.V. Constructions
M/s DHARAM VIR GHAI
jayanti associates
M/S SDS Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .