Tender Value
₹2.8 Cr
EMD Value
₹2.9 L
Closing Date
6 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKSOL
19 conditions · 8 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. per Annexure-N & Annexure-I of tender booklet
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender as per Annexure- G of tender booklet.
b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of dvertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates.
In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Similar Work: - Any Signaling or Telecom work.
28 conditions · 24 needing a document upload
Please submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.as per annexure -J of tender booklet.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work. as per annexure -E of tender booklet.
Please furnish list of Works on hand indicating Description of Work, Contract Value, Approximate value of balance work yet to be done and Date of award.
Please furnish list of Works completed in last seven financial years giving Description of Work, Organization for whom executed, approximate value of contract at time of award, Date of award and Date of Completion. Date of actual Start, Actual Completion and Final value of Contract shall also be given. Annexure -G.
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
Documents to be Submitted Along with Tender: (i)The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (ii)Following documents shall be submitted by the tenderer:
(a)Sole Proprietorship Firm: All documents in terms of Para 10 of the Tender Form (Second Sheet) above (As per GCC-2022). (Annexure-O-1 of tender booklet.)
(b)HUF: i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.as per GCC-2022.
(c)Partnership Firm: All documents as mentioned in para18 of the Tender Form (Second Sheet) as per GCC-2022.As per GCC- 2022. (Annexure-O-2 of tender booklet.)
d) Joint Venture (JV): All documents as mentioned in para 17 of the Tender Form (Second Sheet).as per GCC-2022.
(e)Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.(Eligibility Criteria) above as per GCC-2022. (Annexure-O-10 of tender booklet.)
(f)(i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet)..(Eligibility Criteria) above as per GCC2022. (Annexure : O-11 & O-12 of tender booklet.)
(g)Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer whether sole proprietor/ a company or a partnership firm/registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected.
Any DIPP certificate submitted along with the tender document for, exemption of EMD should be valid on the date of opening of the tender, else the tender offer will be summarily rejected.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderers may also upload the following documents along with his/their tender: The tenderer may upload statement, which shall contain organizational set up and working systems to be adopted by the successful tenderer s during the operation of the contract. It shall contain the details of man power and machineries in the prescribed format and details of methodology for planning, execution, monitoring and completion of the project. The methodology so adopted shall suit to the nature of work and shall also comply fully with best practice and current regulations. A comprehensive detailing for each activity like setting-up organization, safety plan, execution plan, quality assurance plan, sequence of work to achieve the mile stones, ensure targeted progress and quality and in turn deployment of resources, risk analysis and its mitigation strategy shall be given communication arrangement within his organization and with the railways for decisions, progress or any other matter connected with this project to ensure full information about the project including progress of work at different time scale shall also be furnished.
List of works completed in the last seven financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given.
Supportive documents/certificates from the organizations with whom they worked/are working as list of works completed and list of works on hand should be enclosed.
List of works on hand indicating description of work, contract value, and approximate value of balance work yet to be done and date of award.annexure -H
Uploading of declaration regarding Employment/Partnership etc. of Retired Railway Employees as per GCC-2022 as per annexure -Q of tender booklet.
Uploading of Tender Forms shall embody the contents of the contract documents either directly or by reference and shall be as per specimen form, Annexure-I. e-Tender Forms shall be issued free of cost to all tenderers.
A copy of certificate stating that they are not liable to be disqualified and all their statements/documents submitted along with bid are true and factual. Standard format of the certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to Annexure-V, in case of other than Company/Proprietary firm. Annexure-V(A) shall also be submitted by the each member of a partnership firm/Joint Venture (JV)/ Hindu Undivided Family (HUF)/ Limited Liability Partnership (LLP) etc. as the case may be.Non submission of a copy of certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he are/is qualifying the Qualifying Criteria mentioned in the Tender Document. (As per Railway bord letter no.2022/CE-l/CT/GCC- 2022/Policy dt. 13.12.2022)
Declaration form regarding site etc. as per annexure -C of tender booklet.
Declaration regarding constitution of firm as per Annexure-D of tender booklet.
Engineers/Personnel as per annexure -F of tender booklet.
Performa of Completion Certificate as per annexure -L of tender booklet.
Provision of S&T work in connection with Rebuilding of existing overaged steel girder bridges of clear span 12.2M by PSC Slab of Bridges in BINA-DHO Section of Jhansi Division.
JHS-N-W-08-26~NCR
JHS-N-W-08-26
Open
Works - General
12 Months
Jhansi, Uttar Pradesh
₹0
₹2.9 L
6 Mar 2026
5 Feb 2026
20 Feb 2026
136 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,52,75,651.11 | ||
| — | 153.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay(QSPA1 Type), AC immunised, 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS: S - 34, S - 23, S 60 or latest, as applicable. The interlocking code for this unit shall be "ABDEJ"(Inspection Agency-RDSO). | — | — | — | 9,26,629.2 | |
| — | 119.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS- 93 1A and RDSO Specn . No . IRS : S - 34 , S -23 , S - 60 or latest, as applicable. The interlocking code for this unit shall be ABDGH".(Inspection by RDSO). | — | — | — | 5,28,269.56 | |
| — | 10.00 | — | — | ||
| Supply of Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board (base plate), connectors, retaining clips etc. and conforming to BRS- 943 and RDSO Specn. No. IRS:S - 34 , S - 23 , S - 60 or latest, as applicable. The interlocking code for this unit shall be "BCEJK". (Inspection Agency-RDSO). | — | — | — | 53,601.4 | |
| — | 5.00 | — | — | ||
| Supply of Relay A.C. Immune plug in type style (QBAT D.C. baised track relay, 9Ohms, D.C. 2F/2B Contacts front and back contact metal to carbon, complete with plug board , retaining clips and connectors, confirming to RDSO/SON/84 ver 2.0 or latest and RDSO Spec.No. IRS:S - 34, S-23 or latest, as applicable . The interlocking code for this unit shall be"ABEJX". (Inspection Agency-RDSO). | — | — | — | 27,734.7 | |
| — | 72.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver.1.1 Amdt.1 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One couple with suitable rubber O-ring should be supplied with every 6 mtr of pipe length. (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified.(Inspection Agency- Consignee). | — | — | — | 43,694.64 | |
| — | 50.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay, Non-AC immunised, (QN1 Type), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 ,S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ABCDF".(Inspection Agency-RDSO). | — | — | — | 1,81,970.5 | |
| — | 120.00 | — | — | ||
| Supply of Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete with plug board(base plate), connectors and retaining clips and con forming to BRS- 935A and RDSO Specn.No.IRS:S - 34 , S-23 or latest, as applicable. T h e interlocking code for this unit shall be "ABDEG" (Inspection Agency-RDSO). | — | — | — | 6,38,066.4 | |
| — | 105.00 | — | — | ||
| Q-Series Twin Neutral Line Relay(QNN1 Type), 6F/2B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn. No. IRS: S - 34 , S - 23 or latest, as applicable. The interlocking code for this unit shall be "ACDEK". (Inspection Agency-RDSO). | — | — | — | 5,61,082.2 | |
| — | 20.00 | — | — | ||
| Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates.(Inspection Agency-Consignee). | — | — | — | 1,16,142 | |
| — | 146.00 | — | — | ||
| Supply of Walco tape - self-winding,- 38mm (W) X 9M(L).(Inspection Agency- Consignee). | — | — | — | 1,82,413.86 | |
| — | 1035.00 | — | — | ||
| Supply of pressure Sensitive Adhesive Plasticized PVC Tapes having 20 mm Width, minimum 25 Meter length. The colour of the tape shall be decided by Railway in charge. Make: Protex/Nippon/Anchor or better.(Inspection Agency-Consignee). | — | — | — | 42,683.4 | |
| — | 18.00 | — | — | ||
| Supply, installation,wiring,testing and commissioning of SPT (Half Duplex) at IBS location and adjacentstatons. Each set shallcomprise one no. of signalpost telephone SPT) masterunit (Which should beinstalled on IBS post) alongwith one no. of slave unit tobe installed in SM'S officesuitable for working on 24VDC, 25KVRE area andcompatible to work onOFC/Copper media both,ACES make or similar. Note:the contractor shall ensurethat there is no interferencein communication betweenthe master and slave unitsowing to power hump due toRE induction. Cable from IBsignal unit to the cabletermination board in SM'Sroom/relay, room will be provided by Railways.(Inspection Agency-Consignee). | — | — | — | 4,66,323.84 | |
| — | 130.00 | — | — | ||
| Supply of Rubber hand gloves suitable for 1500 Volts. ISI marked Tested certificate to IS: 4770-1968-91 or latest & as per IS: 13774-1993 or latest. Make: commander or Similar. (Inspection Agency-Consignee). | — | — | — | 19,849.7 | |
| — | 12.00 | — | — | ||
| Supply, wiring, installation and commissioning of Earth Leakage Detector (ELD) having 6 digit counter, 12 Channel bus bar, voltage of 110V/60V/24V/12V in AC/DC measurement as per RDSO Spec. RDSO/SPN/256/2002 or latest. This includes supply of fuse terminal strip for incoming power supply wires. Installation to be done on 19 inch sub rack along with insulation resistance meter, remote indication and buzzer in ASM room.(Inspection Agency-RDSO). | — | — | — | 22,95,066.72 | |
| — | 105.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver. 1.0 or latest. Charging capacity rating should be suitable for charging 80 AH Battery. (Inspection by RDSO). | — | — | — | 6,19,558.8 | |
| — | 1250.00 | — | — | ||
| Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S-78/2006 with latest amendments, 2A/4A rating capacity.(Inspection Agency-RDSO). | — | — | — | 1,53,925 | |
| — | 28.00 | — | — | ||
| Supply of Revolving Chair With Arm Asynchronous mechanism of Make:-GODREJ Bravo Mid Black / Geeken /Venus model no.VC2067 or superior as per attached specification. (Inspection Agency:- Consignee). | — | — | — | 2,70,200 | |
| — | 18.00 | — | — | ||
| Supply and installation of Almirah Steel shelving cabinets of Geeken as per attached specification. (Inspection Agency- Consignee). | — | — | — | 4,86,000 | |
| — | 5.00 | — | — | ||
| Supply of Chair for Non supervisors: Model-GODREJ CH-7B or similar reputed make. (Inspection Agency-Consignee). | — | — | — | 28,320 | |
| — | 72.00 | — | — | ||
| Supply of Wheel sensor RSR 180 -001 GS05 ver 23320 or latest for rail claw mounting with 15 mtr of cable (frauscher make) as per spec. no. RDSO / SPN / 176 /2013 ver- 3.0 or latest. (Inspection Agency-RDSO). | — | — | — | 73,55,615.04 | |
| — | 125.00 | — | — | ||
| Supply of clamping bolt for rail claw SK 140 as per spec. no. RDSO / SPN / 176 / 2013 ver- 3.0 or latest. The material to be procured from RDSO approved firm.(Inspection Agency-RITES). | — | — | — | 5,30,216.25 | |
| — | 78.00 | — | — | ||
| Supply of Protection tube flame resistant 14.8 m for wheel sensor cable protection as per spec. no. RDSO / SPN / 176 / 2013 ver-3.0 or latest.(Inspection Agency-Consignee). | — | — | — | 4,03,526.76 | |
| — | 650.00 | — | — | ||
| Supply of IRS Type point machine 'P' bracket insulation complete set consisting of the following: - Plate LH-S - 3266 - 1 No, RH - S -3265- 1 No., Plate S - 8804 - 1 No., Bush -S-3199 -4 Nos, Bush S - 8813 - 2 Nos. The material to be procured as per RDSO Specification IRS/S/40- 84 or latest.(Inspection Agency-Consignee). | — | — | — | 3,12,006.5 | |
| — | 650.00 | — | — | ||
| Supply of stretcher bar insulation complete set consisting of the following: - Plate-T- 10367-1 No., Bush T- 10368- 3 Nos. and washer-T- 10371 -6 Nos.The material to be procured as per RDSO Specification IRS/S/40- 84 or latest.(Inspection Agency-Consignee). | — | — | — | 2,47,968.5 | |
| — | 20.00 | — | — | ||
| Supply of hand track drill machine (Cycle type) of KI Brand (Karar Industries)or reputed branded make.(Inspection Agency-Consignee). | — | — | — | 1,17,946.8 | |
| — | 380.00 | — | — | ||
| Supply of Insulating materials of Ground connection for 220 mm stroke Point Machine as per Drawing No. RDSO/S-3592 (1 No.), RDSO/S-3593 (1 No.),S-23199 (2 No.), S-8640 (4 No.), S- 3463 (1 No.) as per specification No. IRS:S-24/2002 or latest.(Inspection Agency-Consignee). | — | — | — | 1,17,040 | |
| — | 2.00 | — | — | ||
| Supply of Cable route tracer with GPS enable 10 Watt transmitter, rechargeable battery pack and main charger, direct connection lead 10 meter extension cable with all other accessories. Make- Radio detection/Stanley/3M or better.(Inspection Agency-RITES). | — | — | — | 7,16,474 | |
| — | 6700.00 | — | — | ||
| Supply of Disconnect Terminal block for four conductors with screwing cage /clamp type, sliding switch disconnect, as per RDSO spec.No. RDSO/ SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate length of rails for fitting terminal blocks.(Inspection Agency-RDSO). | — | — | — | 12,91,224 | |
| — | 135.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB),4way,made from FRP, as per Drg.No.20101/M(IRS)or latest, including brass bolts and hylam board sheet with terminal setc. The FRP material shall be as per RDSO spec. RDSO/SPN/151/1997 or latest. The technical specifications are as follows:(a)TLJB complete with cover to be in black/red/grey with all the holes required form ounting on FRP stump (vertical two for each FRP angle)HDPE pipe , cable etc.(b)Each TLJB shall have two bakellite terminal block fitted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Along with each TLJB, nickel chrome plated brass links( two nos.of adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe along with two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TLJB.(Inspection Agency-RITES). | — | — | — | 7,37,780.4 | |
| — | 3100.00 | — | — | ||
| Supply of 8 SWG GI wire (4 mm dia) suitable for Track circuit rail bonding as per RDSO spec. IRS: S 13 - 62.(Inspection Agency-Consignee). | — | — | — | 2,79,124 | |
| — | 76.00 | — | — | ||
| Supply of Thermo Shrink Jointing kit for PIJF underground cable 50 PAIRS X 0.63 MM copper conductor dia type TSF-II as per RDSO Specification No.IRS:RDSO/SPN/TC/57/2006 (REV.0) AMDT-1 OR LATEST.(Inspection Agency-Consignee). | — | — | — | 88,783.2 | |
| — | 10.00 | — | — | ||
| Supply of Thermo shrinkable jointing kit as per Spec. No. IRS TC. 77/2012(Rev.3 and Amd.3) or latest for all types joints suitable for 6 Quad Jelly filled UG cables for straight through/derivation joints. It includes supply of all accessories, without transformer.(Inspection Agency-RDSO). | — | — | — | 33,611.5 | |
| — | 40.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S - 34 , S - 23 , S - 60 or latest, as applicable. The interlocking code for this unit shall be "ABDFH".(Inspection Agency-RDSO). | — | — | — | 1,47,846.4 | |
| — | 40.00 | — | — | ||
| Q-Series Twin Neutral Line Relay(QNNA1 Type), AC immunised, 6F/2B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No. IRS : S - 34, S - 23, S - 60 or latest as applicable. The interlocking code for this unit shall be "CDEHX".(Inspection Agency-RDSO). | — | — | — | 1,85,560 | |
| — | 300.00 | — | — | ||
| Supply of GOOD QUALITY 0.63 mm Thick flexible blade type b Hacksaw Blade 300 mm.(Inspection Agency-Consignee). | — | — | — | 2,400 | |
| — | 10.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Electronic hooter (Red colour) with min 85 dB output Approval- UL/LPCB/VDS Listed and shall comply to RDSO/SPN/217/2018 Ver 2. (Inspection Agency-Consignee). | — | — | — | 21,237.9 | |
| — | 10.00 | — | — | ||
| Supply of visitor chair of make venus model no.VC2066/Geeken or superior. (Inspection Agency:-Consignee). | — | — | — | 88,500 | |
| — | 400.00 | — | — | ||
| Supply of L Bracket insulation made of Nylon 66 as per specification No IRS-S-40-84. One set consisting of materials of 1). insulating plate Drg no S8804=1nos, 2) Insulating Bush drg no S8813=2 nos, 3) Insulating washer drg no S8640-2nos. with proper manufacturer text certificate for materials.(Inspection Agency-Consignee). | — | — | — | 10,384 | |
| — | 50.00 | — | — | ||
| Supply of Industrial Grade Silicone sealant, Size 750 milliliter in Cartridge.(Inspection Agency-Consignee). | — | — | — | 30,450 | |
| — | 15.00 | — | — | ||
| Supply of Wired Computer Mouse Or Trackballs 1 Brand: Dell or superior. (Inspection Agency-Consignee). | — | — | — | 5,985 | |
| — | 15.00 | — | — | ||
| Supply of Standard Keyboard - Wired - Plug and Play 1 Years Brand: Dell or superior. (Inspection Agency-Consignee). | — | — | — | 5,249.7 | |
| — | 30.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No.SA-20161-66/M or latest.(Inspection Agency-RDSO). | — | — | — | 68,393.4 | |
| — | 30.00 | — | — | ||
| Supply of 1001 Epoxy HB Finish Paint Applications: Metal, Mild Steel Surfaces; Ratio 3:1; Superior Gloss White Protective Coating Floor Coating Paint- 1 Ltr.(Inspection Agency- Consignee). | — | — | — | 25,380 | |
| — | 3.00 | — | — | ||
| Supply, Installation and commissioning of central gateway. Note: Single centre gateway shall cater maximum up to 32 data transmitter node (Modbus).(As per Annexure A). (Inspection Agency-RITES). | — | — | — | 6,34,756.5 | |
| — | 51.00 | — | — | ||
| Supply, Installation ,testing and commissioning of data transmitter Node in location box. Modbus Type Note: Maximum range 400 meter.(As per Annexure B).(Inspection Agency-RITES). | — | — | — | 9,11,228.22 | |
| — | 12.00 | — | — | ||
| Supply, Installation , testing and commissioning of data transmiter Modbus cum repeater for augmenting range of ourdoor data transmiter node (Modbus), where distance of location box is more than 400 meter with respect to central gateway.(As per Annexure C).(Inspection Agency-Consignee). | — | — | — | 2,14,406.64 | |
| — | 50.00 | — | — | ||
| Supply of Q-Series Track Relay (QTA2 Type), ACimmunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming toBRS: 939A & 966(Appendix F2) or latest and RDSO Specn.No. IRS : S -34 ,S - 23 , S - 60 or latest, as applicable.The interlocking code for this unit shall be "FGHKX".(Inspection by RDSO). | — | — | — | 1,90,162.5 | |
| — | 35.00 | — | — | ||
| — | — | — | 14,00,433.65 | ||
| — | 2.00 | — | — | ||
| — | — | — | 8,49,749.56 | ||
| — | 552.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dial hole, or at any other locations as decided by Site Engineer.(Inspection Agency-RITES). | — | — | — | 5,47,203.12 | |
| — | — | — | 25,21,147.62 | ||
| — | 552.00 | — | — | ||
| Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dial hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012 issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest | — | — | — | 1,99,564.56 | |
| — | 19662.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 1,34,291.46 | |
| — | 160.00 | — | — | ||
| Cross trench for identification of the route of existing signaling and telecom cables. | — | — | — | 46,446.4 | |
| — | 7200.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables / tail cables) at /ARA/Disconnect type terminals provided in |Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, IPS Room, ASM Room etc. under supervision and instructions issued by Engr. incharge of the work. | — | — | — | 1,06,272 | |
| — | 6875.00 | — | — | ||
| Digging of 01 Meter deep and 300MM wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per cable route plan. Note:In case where digging of trench up to 01 Meter depth and 300MM wide is not possible or bigger size trench is required to lay more cables or loose soil/ imuck is encountered, the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 01 Meter deep and 300 MM wide. This also includes Back filling and consolidating of cable trench first for 5 CM (in case where bricks are to laid over cables) after laying of cables and then complete back filling & Ramming of loose soil. In all type of soils including soft rock. | — | — | — | 3,56,812.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .