Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.4 CrAdmitted-Finance | -7.20% | ₹2.4 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | - | Rejected-Technical as per enclosed Evaluation sheet |
Tender Value
₹2.6 Cr
EMD Value
₹5.3 L
Closing Date
14 Oct 2024, 6:00 pmClosed
Executive Engineer M and H, Dn. I Jaipur
Executive Engineer M and H, Dn. I Jaipur
SITC of HVAC System work for Construction of Sub District Hospital at Behror, Distt. Kotputli-Behror
2024_MEDIC_424973_1
NIT 26/2024-25EEM and HDn. I Jaipur/
Open Tender
Electrical Works
Percentage
240 days
Kotputali-Behror
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
RTGS/NEFT/Any other money Transfer System
₹5.3 L
28 Nov 2024
1 Oct 2024
15 Oct 2024
1 Oct 2024
14 Oct 2024
1 Oct 2024
Amount
Supply,installation, testing and commissioning of factory fabricated Double Skinned DX Coil Air- handling unit fabricated out of extruded aluminium section with 0.8mm pre-plasticized /pre-coated Galvanised steel sheet outside & 0.8 mm polished GI sheet inside complete with supply blower section with single / multiple AMCA certified backward curved plug fan with aerofoil design blades, power control panel with necessary switchgears incoming & outgoing for VFD, blower suitable for static pressure as required (Fan Static given below is for guideline), blower motor TEFC (IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 row cooling coil made of Aluminium finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media MERV 8 filters in extruded aluminium frame in both the supply & exhaust side of AHU, fine filter section with MERV 13 filters in extruded aluminium frame in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost),. The capacity of Air-handlers shall be as follows:
3200 CFM (8.0 TR ) ESP - 120 mm
2400 CFM (6.0 TR ) ESP - 120 mm
Fresh & Exhaust air in line fan: - Supply, installation, testing and commissioning of Exhaust &fresh air inline fan.
400CFM (static pressure upto 20 mm)
800 CFM (static pressure upto 20 mm)
900 CFM (static pressure upto 20 mm)
1000 CFM (static pressure upto 20 mm)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.96 MB
Tendernotice_2.pdf
PDF • 0.26 MB
Tendernotice_3.pdf
PDF • 0.46 MB
Tendernotice_4.pdf
PDF • 0.25 MB
Tendernotice_5.pdf
PDF • 2.72 MB
Tendernotice_6.pdf
PDF • 0.07 MB
Tendernotice_7.pdf
PDF • 2.57 MB
Tendernotice_8.pdf
PDF • 0.14 MB
SBD.pdf
Tender Documents • 0.67 MB
BOQ_763690.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .