Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹64.4 LAccepted-AOC | ₹64.4 L Quoted ₹66.4 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹76.5 LRejected-AOC HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | ₹76.5 L | L-2 | Rejected-AOC Other than L-1 |
| Sl No | Description | Qty | Unit | VRIDHI ENTERPRISES L1 | m/s AR Construction co L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down Chowkats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed by Engineer-in-Charge. | 136 | EACH | 100 ₹13,600 | 100 ₹13,600 |
| 2.00 | Taking down chowkhats or frame exceeding 1.5 Sqm but not exceeding 4.00 sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified and as directed by Engineer-in-Charge. | 20 | EACH | 100 ₹2,000 | 150 ₹3,000 |
| 3.00 | S&F Pressed steel frame 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick Mild steel sheet including necessary fixing lugs, lock strike plates complete, providing mild steel 6 mm dia threshold bar including filling hollow frame with plain cement concrete with and including one shop coat of primer complete all as specified and directed by Engineer-in-charge.
Note:- PCC for filling of frame shall be measured and paid separately here-in-after under relevant item of this schedule. | 98 | RM | 440 ₹43,120 | 400 ₹39,200 |
| 4.00 | Providing Plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregates) for filling hollow pressed steel door frames complete all as specified and as directed by Engineer-in-Charge. | 0.75 | CUM | 3,000 ₹2,250 | 2,000 ₹1,500 |
| 5.00 | S&F 2nd class hard wood factory made 35 mm thick panelled door shutter (two panel) factory made, with lock rail and panel of 9 mm thick BWP commercial ply or 12 veneered particle board with commercial veneering on both faces, the size of rail and style as per IS 1003 (part-I) klin seasoned and chamically treated complete all as specified and directed by Engineer-in-charge. | 36 | SQM | 2,500 ₹90,000 | 2,200 ₹79,200 |
| 6.00 | S&F 35 mm thick 2nd class hard wood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing chamfered plain or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge. | 36 | SQM | 2,200 ₹79,200 | 1,700 ₹61,200 |
| 7.00 | S&F Powder coated aluminium sections as in frames/ shutter of sliding or openable doors/ window/ ventilators including necessary joining cleats, screws, rollers etc., complete all as specified and as directed by Engineer-in-charge.
Note: 1. minimum thickness of powder coating shall not be less than 50 micron.
2. Weight of aluminium section only shall be measured and paid.
3. The rate shall be inclusive of neoprene beadings, 01 Nos of Handle (powder coated) 100 mm size for each leaf, 03 Nos of stainless steel hinges 75 mm Size for each leaf, 02 Nos of towerbolt (powder coated) 100 mm size for each leaf, 01 Nos hook and Eye for each leaf, fixing with Stainless steel screws minimum 02 nos roller per shutter etc., weight of fitting fixtures will not be measured for arriving the weight of aluminium section.
4. Glass and wooden panels shall be measured and paid separately under respective items.
5. Design shall be approved from engineer-in-charge at site before fabrication and bulk order to the manufacturer. | 108 | KG | 550 ₹59,400 | 650 ₹70,200 |
| 8.00 | Supply and fixing 5.5 mm thick sheet glass, ordinary quality, size in squares/ rectangles not exceeding 0.5 Sqm in each pane, fixed in aluminium frame with EPDM packing, complete all as specified and as directed by Engineer-in-Charge. | 5 | SQM | 650 ₹3,250 | 600 ₹3,000 |
| 9.00 | Supply and fixing 3.0 mm thick aluminium composite panel sheet (ACP) colour as approved by GE, fixed to aluminium frame work, complete all as specified and as directed by Engineer-in-Charge. | 2.5 | SQM | 700 ₹1,750 | 1,500 ₹3,750 |
| 10.00 | S&F Factory made box type steel section ventilator with top/ centre hung shutter double leaf shutter for glazing and wire gauze with pintle hinges & 01 No 150 mm mild steel tower bolt, hinges, steel peg stay, steel handle to each shutter, steel handle dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and as directed by Engineer-in-Charge.
Note : Glass/ Wire mesh required for fixing in ventilator will be measured and paid for separately. | 5.1 | SQM | 5,000 ₹25,500 | 6,000 ₹30,600 |
Updated dates
Tender Value
₹82.4 L
EMD Value
₹1.5 L
Closing Date
28 Oct 2025, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM-64/2025-26 SPECIAL REPAIR OF BUILDING NO P- 810 AND P-981 UNDER GE CHANDIMANDIR AT CHANDIMANDIR MIL STATION
2025_MES_724135_2
CWE/CHM-64/2025-26
Open Tender
Civil Works
180 days
GE Chandimandir
Class C, Cate a(i)
9 documents required · 9 mandatory
₹1,000
GE Chandimandir
₹1.5 L
23 Dec 2025
25 Sept 2025
4 Nov 2025
25 Sept 2025
28 Oct 2025
9 Oct 2025
25 Sept 2025 - 30 Sept 2025
Amount
Taking down Chowkats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frame exceeding 1.5 Sqm but not exceeding 4.00 sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified and as directed by Engineer-in-Charge.
S&F Pressed steel frame 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick Mild steel sheet including necessary fixing lugs, lock strike plates complete, providing mild steel 6 mm dia threshold bar including filling hollow frame with plain cement concrete with and including one shop coat of primer complete all as specified and directed by Engineer-in-charge. Note:- PCC for filling of frame shall be measured and paid separately here-in-after under relevant item of this schedule.
Providing Plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregates) for filling hollow pressed steel door frames complete all as specified and as directed by Engineer-in-Charge.
S&F 2nd class hard wood factory made 35 mm thick panelled door shutter (two panel) factory made, with lock rail and panel of 9 mm thick BWP commercial ply or 12 veneered particle board with commercial veneering on both faces, the size of rail and style as per IS 1003 (part-I) klin seasoned and chamically treated complete all as specified and directed by Engineer-in-charge.
S&F 35 mm thick 2nd class hard wood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing chamfered plain or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
S&F Powder coated aluminium sections as in frames/ shutter of sliding or openable doors/ window/ ventilators including necessary joining cleats, screws, rollers etc., complete all as specified and as directed by Engineer-in-charge. Note: 1. minimum thickness of powder coating shall not be less than 50 micron. 2. Weight of aluminium section only shall be measured and paid. 3. The rate shall be inclusive of neoprene beadings, 01 Nos of Handle (powder coated) 100 mm size for each leaf, 03 Nos of stainless steel hinges 75 mm Size for each leaf, 02 Nos of towerbolt (powder coated) 100 mm size for each leaf, 01 Nos hook and Eye for each leaf, fixing with Stainless steel screws minimum 02 nos roller per shutter etc., weight of fitting fixtures will not be measured for arriving the weight of aluminium section. 4. Glass and wooden panels shall be measured and paid separately under respective items. 5. Design shall be approved from engineer-in-charge at site before fabrication and bulk order to the manufacturer.
Supply and fixing 5.5 mm thick sheet glass, ordinary quality, size in squares/ rectangles not exceeding 0.5 Sqm in each pane, fixed in aluminium frame with EPDM packing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 3.0 mm thick aluminium composite panel sheet (ACP) colour as approved by GE, fixed to aluminium frame work, complete all as specified and as directed by Engineer-in-Charge.
S&F Factory made box type steel section ventilator with top/ centre hung shutter double leaf shutter for glazing and wire gauze with pintle hinges & 01 No 150 mm mild steel tower bolt, hinges, steel peg stay, steel handle to each shutter, steel handle dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and as directed by Engineer-in-Charge. Note : Glass/ Wire mesh required for fixing in ventilator will be measured and paid for separately.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Note: M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/ window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F of Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/ or rivetted, or forged into spikes; framed guard bars; barred iron doors; manhole cover; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and as directed by Engineer-in-Charge.
S&F in repair stainless steel wire cloth 0.56 mm nominal dia of wire & avg width of aperture 1.18 mm fixed with tinned tacks or galvanised wire staples complete all as specified and as directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 3 mm thick figured (frosted) glass, pin head type, ordinary quality and fixed in any type of frame and glazing with oil putty (or beading) in squares not exceeding 0.5 Sqm in each panes complete all as specified and as directed by Engineer-in-Charge.
S&F 200 mm size Aluminium barrel tower bolt of extruded section and fixed complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm size Aluminium barrel tower bolt of extruded section and fixed complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm size aluminium handle (ISI Marked) cast type, anodized, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing aluminum alloy, anodized, sliding door bolt (ISI Marked) 250 mm long hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and as directed by Engineer-in-charge.
S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed by Engineer-in-Charge.
Repair to RCC sunshades, chajjas, balconies, coloumns, bands, beams and similar RCC work at any position/ height by dismantling loose/ disintegrated portion including necessary scaffolding and safety arrangements and fixing of reinforcement (cut to length, bent to shape required, including cranking, bending spirally including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips)/ chicken wire mesh wherever required and dubbing out with cement concrete 1:1.5:3, 15 mm to 50 mm thick, using 6 to 12 mm graded stone aggregate to make up and finished the required shape including provision of necessary scaffolding and formwork up to three storey building if required and finished with 5 mm thick rendering in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
(NOTE : Supply only reinforcement and chicken wire mesh will be measured and paid separately under respective items)
M&L for 75 mm thick plain Cement Concrete type 1:3:6, type C-1 (Using 20 mm graded stone aggregates) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Post Construction ATT along the external wall below concrete or masonry apron using chemical emulsion@ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles including disposal of demolished material n. Exc 1.5 km complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with sub-class ‘B’ bricks (old size bricks), straight or curved on plan to any radius in half brick thick walls, for partition wall, parapet in balcony and other similar work built in Cement Mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M&L for Non Skid ceramic coloured tiles, 7 mm to 8 mm thick, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick cement mortar 1:6 screed bed for floor finishes complete all as specified and as directed by Engineer-in-charge.
M&L for Glazed ceramic coloured tiles in vertical surfaces of size 450 mm x 350 mm x 7 mm thick, set and jointed in neat cement slurry over 10 mm thick rendering in CM 1:4 for receiving the tiles complete all as specified and as directed by Engineer-in-charge.
Taking down existing plaster of any description on brick wall/ concrete surface/ parapet wall including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on brick or concrete surfaces with or without mixing WPC, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note:- WPC shall be measured and paid separately.
Material and labour for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 5 mm thick in cement mortar 1:3 on ceiling surfaces of any description finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-charge.
M&L for Machine cut kota stone slab in flooring, 18-20 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 15 mm thick cement screed in CM 1:6, including rubbing and polishing complete all as specified and as directed by Engineer-in-Charge.
Materials and labour for 16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plateform and like over and including 15 mm thick cement morter (1:4) bedding including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 18 to 20 mm thick baroda green stone, machine cut, laid over & including 15 mm thick (average thickness) screed bedding in cement mortar (1:4) laid and jointed with grey cement slurry and pointed with grout of matching shade on kitchen plateform, RCC Counters, Stairs, window sill and the like including making hole for gas pipe complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old plastered ceiling surfaces and applying two coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, white or tinted as ordered, over a coat of primer complete all as specified and as directed by Engineer-in-charge.
M&L for Preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour), including making arrengements for necessary scafolding and safety equipments for carrying out work upto a height of four storey building complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old plastered surfaces of wall and applying two coats of cement base paint over a coat of chalk whitening including making arrengements for necessary scafolding and safety equipments for carrying out work upto a height of four storey building complete all as specified and as directed by Engineer-in-charge.
S&F factory made (Box type) Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, tower bolts complete with glazing bars, dovetailed or welded including one shop coat of red oxide primer etc complete all as specified and as directed by Engineer-in-charge.
M&L for preperation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of New or previously untreated wooden surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel (ordinary tint) paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
Taking up or down GI steel tubing 15 mm with connections or fittings from wall, ceiling, floor etc., including removal to store complete all as specified and as directed by Engineer-in-charge.
Taking up or down GI steel tubing 20 mm with connections or fittings from wall, ceiling, floor etc., including removal to store complete all as specified and as directed by Engineer-in-charge.
Supplying and laying of CPVC pipes outer diameter 20 mm, SDR 11 (concealed or unconcealed as per site requirement) with Plain CPVC SDR 11 fittings as required to wall, ceiling or laid under floors including cutting chases and making good in cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge.
Supplying and laying of CPVC pipes outer diameter 25 mm, SDR 11 (concealed or unconcealed as per site requirement) with Plain CPVC SDR 11 fittings to wall, ceiling or laid under floors including cutting chases and making good in cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge.
S&F Brass Tee of outer dia 20 mm complete all as specified and as directed by Engineer-in-charge.
S&F Brass elbow of outer dia 20 mm complete all as specified and as directed by Engineer-in-charge.
S&F Male Brass Threaded Adaptor of outer dia 20 mm complete all as specified and as directed by Engineer-in-charge.
S&F Female Brass Threaded Adaptor (FTA/ FBTA) of outer dia 20 mm complete all as specified and as directed by Engineer-in-charge.
S&F Tank Adaptor of outer dia 20 mm complete all as specified and as directed by Engineer-in-charge.
S&F Brass Tee of outer dia 25 mm complete all as specified and as directed by Engineer-in-charge.
S&F Brass elbow of outer dia 25 mm complete all as specified and as directed by Engineer-in-charge.
S&F Male Brass Threaded Adaptor of outer dia 25 mm complete all as specified and as directed by Engineer-in-charge.
S&F Female Brass Threaded Adaptor (FTA/ FBTA) of outer dia 25 mm complete all as specified and as directed by Engineer-in-charge.
S&F Tank Adaptor of outer dia 25 mm complete all as specified and as directed by Engineer-in-charge.
S&F in repair Vitreous China wash hand basin, white, flat back, size 550 x 400 mm including brackets with including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed by Engineer-in-charge.
S&F waste pipe of polyethylene of low or high density or PVC, 32 mm dia, complete all as specified and as directed by Engineer-in-charge.
S&F as in repair Vitreous China Wash down water closet pedestal pattern white with and including plastic seat cover back, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair vitreous china squatting pan, “Orissa” pattern size 580 mm x 440 mm, white, with integral foot rests including PVC P or S trap (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe complete set in cement concrete complete all as specified and as directed by Engineer-in-charge.
Demolition of un-reinforced cement concrete exceeding 15 cm thick of any description and in any position not other wise specifially provided for and removing all demolished material/ debris upto 1.00 Km from the site and depositing where directed complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:5:10 E-2, (using 40mm graded brick aggregates) as in sunken filling and mass concrete complete all as specified and directed by Engineer-in-charge.
Water proofing treatment to sunken portion and adjoining walls of kitchen, WC, Bath & Toilet, etc, as follows, complete all as specified & directed :- (a) 15 mm thick plaster in cement mortar (1:3) mixed with WP compound as per manufacturer's instructions shall be provided on sunken portion after roughening of surfaces. (b) Apply cement slurry to the surface @ 0.488 kg/Sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/Sqm and the surface will be allowed to air cure for 4 hours. (c) Apply another layer of cement slurry @ 0.242 kg/Sq. m of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 Kg/Sq. m and the surface will be allowed to air cure for 4 hours. (d) Pond curing of sunken portion for minimum of 48 hours. (e) Paste one layer of 3 mm thick APP membrance with bitumen by torch application to the the treated sunken surface. (f) Joints/ traps/ WC/ soil pipes shall be properly sealed with approved sealing compound
Supply and fixing in repair PVC (SWR) pipe and vent pipes, 110 mm bore of pressure rating 6 kg/ cm2, single socketed in any length with rubber ring joints fixed with solvent cement laid in trenches or in floors, complete all as specified and as directed by Engineer-in-Charge. Note: Excavation and earth work shall be measured and paid for separately.
Supply and fixing in repair PVC (SWR) pipe and vent pipe 110 mm of pressure rating 6 kg/ cm2, single socketed in any length with rubber ring joints fixed with solvent fixed to walls including clamps as required, complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 69.00 here-in-before but pipe of 75 mm bore.
S&F 110 mm PVC (SWR) bend provided with access door in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) bend with accessible door in repair complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm PVC(SWR) junction single with accessible door, (Single T) in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F 75 mm PVC(SWR) junction single, (Single T) in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm PVC(SWR) vent cowl in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm PVC(SWR) P trap fixed in repair, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair towel ring of PTMT, fixed with and including chromium plated screws with pvc rawl plugs complete all as specified and as directed by Engineer-in-Charge.
S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing tanks of capacity exceeding 500 Litre and not exceeding 1000 Litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm bore bib taps, cast copper alloy, chromium plated with capstan head, screwed down for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F in repair 15 mm bore pillar tap, long neck, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Chromium plated brass shower rose with arm 100/ 125 mm dia with swivel joints, including fixing to pipe or union complete all as specified and directed by Engineer-in-charge.
Supply and fixing of angular stop cock, fancy type, cast copper alloy, chromium plated, screwed down, screwed both ends for iron pipe or for union suitable for 15 mm bore pipe, fixed as in repair complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, suitable for 15 mm bore pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Serial item no. 85.00 here-in-before but suitable for 20 mm bore pipe.
S&F in repair 15 mm bore Stop valves (concealed type), cast copper alloy, chromium plated, screwed down, high pressure, with capstan head, with long shank and cup screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
S&F in repair tubular towel rail, brass, chromium plated, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC (SWR) 75 mm dia floor trap, plain with CP grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs vitreous china urinal, half stall type, white and including all fixing accessories, and waste pipe complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Vitreous china urinal partition, white, of size 310 x 700 mm Urinal partitions slabs terminating about 40 cm above floor line complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Urinal spreader of PTMT, any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified and as directed by Engineer-in-charge.
S&F Health faucet (ABS Body), mild steel chromium plated, suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position ccomplete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC valveless, syphonic action type flushing cistern of 10 litre capacity, low level, white with inlet ball valve, float and handle including brackets complete all as specified and as directed by Engineer-in-Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm long fixed as in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs waste coupling of PTMT, for WHB, any colour, half or full threaded, suitable for 32 mm size discharge pipe (Minimum weight 45 gm), complete all as specified and as directed by Engineer-in-Charge.
S&F Soap dish, Brass, CP, approximate size 160 mm x 160 mm x 90 mm Vitreous China soap tray embedded in the wall complete all as specified and as directed by Engineer-in-Charge.
Dismantling of brick tiles or tertacing tiles on roof, any thickness, jointed in any mortar (including cement mortar) and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) including removal of such material outside the defence land complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregates as in roof padding complete all as specified and as directed by Engineer-in-Charge.
M&L for 20 mm thick rendering in CM 1:3 to roof surfaces, bearing plaster, sunken portion etc., including mixing with Water proofing compound finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note: WPC will be measured and paid separately.
M&L for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid on primed surface, on roof padding including wire brush cleaning on existing surface complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete tile 25 cm x 25 cm x 20 mm thick, with grey cement and no pigment, machine pressed, set jointed and pointed in neat cement slurry in floors, cut and polished as in floors over and including 15 mm thick screed bed of CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparing surface of wall and applying 15 mm thick cement plaster in 1:4 cement sand mortar mixed with integral water proofing compound in wall surface including applying two coat of Epoxy Resin coating Polymer modified cementitious coating like brush bon of Fosroc, Asian paint, Pidilite and Bostic as per manufacturer's recommendation on wall surface (shaft area) upto 4 storey building including all necessary scaffolding and safety arrangement complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparation of wall or similar surface by removing all loose material, clean by wire brush and water, applying two coats of damp proof component, such as sure seal by Dr Fixit or equivalent in Asian paints, Fosroc and pidilite, applying the component by brush 1.10 kg/sqm for each coat, second coat in perpendicular direction to first coat and after 4-6 hour dry of first coat complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound, ISI Marked, complete all as specified and as directed.
M&L for excavating in post holes (or similar holes) each not exceeding 0.5 cum, in Soft/ loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engineer-in-Charge.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240t complete all as specified and as directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick, any colour, having tensile strength 550 Mpa as in roof coverings/ cladding to wall, fixed with self tapping screws etc., including dismantling of old sheet of any description complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain Cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for providing Reinforced cement concrete 1:2:4, Type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 m clear span, Beams, cantilevers, bressummers, complete all as specified and as directed by Engineer-in-charge. Note : (Reinforcement shall be measured and paid separately)
Material and Labour for providing Reinforced cement concrete 1:2:4, Type B-1 (using 20mm graded stone aggregate) as in chajjas, facias, etc. complete all as specified and as directed by Engineer-in-charge. Note : (Reinforcement shall be measured and paid separately)
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, for rough finished surface of concrete complete all as specified and as directed by Engineer-in-charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200 mm thick (Horizontal or sloping) for rough finish surface of concrete complete all as specified and as directed by Engineer-in-charge.
Mild steel TMT bars 10 mm dia. and over, cut to length, bent to shape as required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality complete all as specified and as directed by Engineer-in-charge.
Mild steel TMT bars, upto 8 mm dia., cut to length, bent to shape as required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed by Engineer-in-charge.
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of perforated perforated 12mm Size 595 mm x 595 mm of approved texture, 12 mm thick thick micro tegular design and patterns having moisture micro tegular edged or 10 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC 0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, on combustible as per BS tiles tiles 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 gram per sqm both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15 x 32 mm of length 1200 mm Contd....
Contd.. and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600 mm x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85 mm x 25 mm x 2 mm. Galvanised iron perimeter wall angle of size 24 mm x 24 mm x 0.40 mm of length 3000 mm to be fixed on periphery with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-charge.
Supply and fabrication of Precast compound wall with M-25 grade concrete with precast RCC columns and precast RCC panels properly finised and free from projection as specified under and direction by the Engineer-in-charge :- (a) Each panel shall be of size 1800 mm x 300 mm x 50 mm, reinforced with 04 Nos of 4 mm dia prestresing wires along the shorter span and 5 Nos of 4 mm dia wires along the longer span. (b) Precast Columns/ post shall have size of 150 mm x 150 mm on plan having groove that can fit the precast RCC panels with 7 Nos of prestressing wire (3 on each flange and 1 in centre of web in plan), grouted minimum 900 mm below ground level and properly packed with concrete. Note:- The rate is inclusive of transporting, loading/ unloading and construction of the wall with precast compound wall panels at site, concreting to the foundation will be measured and paid separately.
Taking down copper/ aluminum point wiring for (light, fan, socket point 5/15 amps) complete including fitting such as switches, ceiling rose, light fittings, sockets, bulb holder, ceiling roses etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors etc complete all as specified and as directed by Engineer-in-Charge.
M&L for Point wiring with PVC insulated PVC unsheathed electric FRLSH cable, 1100V grade, single core, having multi stranded copper conductor of size 1.5 sqmm for phase & neutral drawn in Existing concealed PVC conduits with sheet steel modular sunken/ flush boxes 1.2 mm thickness and suitable size of frame cover for mounting modular switch, socket and regulator fixed on surface in touch with wall and including 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs for one light point/ fan point/ bell point controlled by one switch complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No 120.00 here-in-above but for one socket outlet 3/5 pin, 5 amps on same board.
All as per Serial item No 120.00 here-in-above but for one socket outlet 3/5 pin, 5 amps on independent board.
All as per Serial item No 120.00 here-in-above but for one light point controlled by two way switch.
All as per Serial item No 120.00 here-in-above but for one socket outlet 3/5 pin, 15 amps on independent board size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire as specified.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2 mm thickness covered with provision of 3 mm thick plastic laminated sheet, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge. Note : Unit rate is inclusive of cutting chases in wall/ floor/ PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
All as per Serial item No 125.00 here-in-above but for one socket outlet 3/ 5 pin, 5 amps on same board.
All as per Serial item No 125.00 here-in-above but for one socket outlet 3/5 pin, 5 amps on independent board.
All as per Serial item No 125.00 here-in-above but for one light point controlled by two way switch.
All as per Serial item No 125.00 here-in-above but for one socket outlet 3/5 pin, 15 amps on independent board size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire as specified.
S&F modular switch, one way, 6 Amps, one module 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push, single pole, one module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, two way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet, 2 in 1, 3/5 pin, 6 Amps, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet, 2 in 1, 6/16 Amps, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular type fan regulator, single pole, 230 volt, two module, complete all as specified and as directed by Engineer-in-Charge.
S&F Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F Switch piano, flush type, 6 amps, 230 volts, single pole, two way (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F Sockets outlet, 6 Amps, flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge.
S&F Sockets outlet, multipurpose 2 in 1 pin, 6 and 16 Amps, flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge.
S&F Stepped type electronic fan regulator, flush type, complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite, 65 x 50 mm dia, three terminal complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder, insulated body, PVC/Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed by Engineer-in-Charge.
S&F LED Lamp, 9W, B22 type complete all as specified and as directed by Engineer-in-Charge.
S&F electric ding dong bell, AC, 230 volt, single pole complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnection of power supply and taking down carefully by unscrewing from board fittings and fixtures such as MCB DB, junction box, panels of any size complete with all MCCB's, MCB's etc and removing from site, complete all as specified and as directed by Engineer-in-Charge.
S&F vertical TPN distribution board, double door, flush mounting with provisions for MCCBs incommer upto 125 to 160 Amp & outgoing, 4 way having IP 54 protection complete all as specified and as directed by Engineer-in-Charge.
S&F for MCB distribution board having IP-43 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 12 way, SPN, with 200 Amps rated busbar 230V AC supply complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosures for MCB, 240 volts, 8 way, double door, fitted with 200 Amp rated bus bar, neutral link, earth bar and din rail complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SPN, 32 Amp, 230 volts having breaking capacity 10KA "B" type complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SP, 40 to 63 Amp, 230 volts having breaking capacity 10KA "B" type complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SP, 6-32 Amp, 240V, 10 KA, 'B' curve Complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB, 4 Pole, 415 V, Adjustable thermal and fixed magnetic type, 160 Amps with breaking capacity 36 KA complete complete all as specified and as directed by Engineer-in-Charge.
S&F LED light fitting, 1x 9W/ 1x 10W bulkhead luminaries including LED light driver connection up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as tube light fittings for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and as directed by Engineer-in-Charge.
Fixing only LED light fittings, any wattage, 220V, with driver, holder including LED tube light including connecting up with existing cable of from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F SLIM LED batten with polycarbonate housing and diffuser with elegantly designed end caps 1 x 20W, 220 V, AC connecting up with two core flexible of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F in repair LED light fitting, mirror type with high output diffuser 2 feet, 10 watt, 220 V AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking down carefully copper/ aluminium sub main wiring complete, including existing batten/ conduit etc., removing materials and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed by Engineer-in-Charge.
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed, multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm LT, 1100V grade, down through and including adequate sizes medium type PVC non metallic conduit with accessories and fittings and one run of 4.0 sqmm single core, multi stranded, copper conductor cable as earth continuity conductor complete all as specified and as directed by Engineer-in-Charge.
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 6.0 sqmm LT, 1100V grade, down through and including adequate sizes medium type PVC non metallic conduit with accessories and fittings and one run of 6.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor complete all as specified and as directed by Engineer-in-Charge.
Notes for item No 162.00 and 163.00 :- (i) for payment purpose, two runs runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one running meter length. (ii) Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. (iii) Earth wire shall run inside the conduit pipe.
M&L of Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 10.0 sqmm LT, 1100V grade, down through and including adequate sizes medium type PVC non metallic conduit with accessories and fittings and one run of 10.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor complete all as specified and as directed by Engineer-in-Charge.
Notes :- (i) for payment purpose, four runs runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one running meter length. (ii) Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. (iii) Earth wire shall run inside the conduit pipe.
M&L for LED panel, surface mounted, 2' x 2', 36 watts, cool day light fitting with heat exchanger unit, LED driver, surge protection complete including making good disturbed including taking down any type ceiling fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement round shape 12 watt, 220 volts, AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED security light fitting, 35 Watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
S&F exhaust fan, steel body, AC, single phase, 230 V of size 300 mm sweep with blades, frame and louvers complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing exhaust fan, made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., and not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of 50 mm outer dia High density polyethylene (HDPE) duct pipes of pressure rating 6 kgf/sqcm conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittting for cable protection complete all as specified and as directed by Engineer-in-Charge.
Supply, laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of Size 35 Sqmm x 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of GI pipe, 40 mm bore, "Light grade" for protection of electric cable, fixed on wall/ floor/ under road including with all fitting and fixtures complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electorde 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) connected to galvanised earth lead wire 4 mm dia by means of GI bolts nuts, check nuts washer of galvanised iron or steel all as shown in electric plate No 5 of MES SSR Part-I and including excavation & earth work in any type of soil, disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix (1:3:6) type C-I with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8 mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering pipe of 20 mm dia GI light grade and 15 mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note:- The quoted unit rate shall be including of protection pipe and GI wire from top to earth plate up to 7.5 meters.
m/s AR Construction co (BID ID -3457945)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_820218.xls
BOQ • 0.50 MB
Tenderdocuments64.pdf
Tender Documents • 0.85 MB
Additional64.pdf
Additional Documents • 0.50 MB
Download all tender documents and submit your bid