Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical The bidder not fulfill the QR |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
5 Jul 2022, 11:00 amClosed
CE(CTPP)
ADM Building, Motipura Chowki, Chhabra
Procurement of Various CTs, PTs and Control Transformers for CTPP, Chhabra
2022_RRVUN_271985_1
NIB-1201/2022-23(MM)
Open Tender
Electrical Goods/Equipments
Item Wise
120 days
CTPP, RRVUL, CHHABRA
As per uploaded our tender documents
2 documents required · 2 mandatory
₹590
Yes
account Officer, CTPP, RVUNL, Chhabra
₹37,000
Yes
21 Sept 2022
4 May 2022
5 Jul 2022
4 May 2022
5 Jul 2022
4 May 2022
POTENTIAL TRANSFORMER
Potential Transformer 1-Ø, 50 Hz, Rating: 415/√3/110/√3, Burden: 50/100 VA, Voltage factor : 1.2, Class: 0.5/3P, Approx Dimesion: 12.5x13x10.5 cm, Insulation class- F confirming as per IS 3156 & IS 4146
Potential Transformer 1-Ø, 50Hz, Rating: 415/√3/110/√3, Burden: 100 VA, Voltage factor : 1.2 Continuous & 1.9 for 8 hours, Class 1, Approx Dimesion: 9.5x13x11.5 cm, Insulation class- F confirming as per IS 3156 & IS 4146
Potential Transformer 1-Ø, 50Hz, Rating: 415/√3/110/√3, Burden: 50 VA, Voltage factor : 1.2, Class 1,Approx Dimesion: 12.5x13x11.5 cm, Insulation class- F confirming as per IS 3156 & IS 4146
Potential Transformer 1-Ø, 50Hz, Rating: 415/√3/110/√3, Burden: 100 VA, Voltage factor : 1.5 Continuous & 1.9 for 8 hours, Class 1,Approx Dimesion: 12.5x12.5x9.5 cm, Insulation class- F confirming as per IS 3156 & IS 4146
Potential Transformer 1-Ø, 50Hz, Rating: 415/√3/110/√3, Burden: 50 VA, Voltage factor : 1.2, Class 1,Approx Dimesion: 8.5x9.5x9.5 cm, Insulation class- F confirming as per IS 3156 & IS 4146
Current Transformers for protection, Class 5P20, Type : Window, Burden 10VA, INS Class: F, Frequency : 50Hz, IL : 0.66/3kV, HSV: 0.66 kV, as per IS2705 and IS4201
CT ratio 4000/1 Compatible to Bus size 15.5 X 10 cm
CT ratio 3200/1 Compatible to Bus size 15 X 10 cm
CT Ratio 1250/1 Compatible to Bus size 15.5 X 5 cm
CT Ratio 350/1 Min. CT bore diameter 5.5 cm
CT Ratio 250/1 Min. CT bore diameter 5.5 cm
CT Ratio 800/1 Compatible to Bus size 11 X 4 cm
CT Ratio 300/1 Min. CT bore diameter 5.5 cm
Current Transformers for protection, Class 5P10, Type : Window, INS Class: F, Frequency : 50Hz, IL : 0.66/3kV, HSV: 0.66 kV, as per IS2705 and IS4201
CT Ratio 300/5, Buden 10VA, Min. CT bore diameter 5.5 cm
CT Ratio 1250/5,Buden 10VA Compatible to bus size 6cm x 3 cm
CT Ratio 1250/5,Buden 15VA Compatible to bus size 7 cmx 6.5 cm
CT Ratio 4000/5, Burden 10VA Compatible to bus size 15cm x 5 cm
CT Ratio 600/5, Burden 10VA, Compatible to bus size 6cm x 3 cm
CT Ratio 600/5, Burden 15VA, Compatible to bus size 6cm x 3 cm
Current Transformers for metering, Class 1, Type : Window, Burden 10VA, INS Class: F, Frequency : 50Hz, IL : 0.66/3kV, HSV: 0.66 kV, as per IS2705 and IS4201
CT ratio 4000/1 Compatible to Bus size 15.5cm X 10 cm
CT ratio 3200/1 Compatible to Bus size 15cm X 10 cm
CT Ratio 1250/1 Compatible to Bus size 16cm X 5 cm
CT Ratio 350/1 Min. CT bore diameter 5.5 cm
CT Ratio 250/1 Min. CT bore diameter 5.5 cm
CT Ratio 800/1 Compatible to Bus size 11cm X 4 cm
CT Ratio 400/1 Min. CT bore diameter 5.5 cm
CT Ratio 300/1 Min. CT bore diameter 5.5 cm
CT Ratio 200/1 Min. CT bore diameter 5.5 cm
Current Transformers for metering, Class 1, Type : Window, Burden 15VA, INS Class: F, Frequency : 50Hz, IL : 0.66/3kV, HSV: 0.66 kV, as per IS2705 and IS4201
CT Ratio 300/5, Min. CT bore diameter 5.5 cm
CT Ratio 150/1, Minimum CT bore diameter 4.5 cm
CT Ratio 200/5, Min. CT bore diameter 5.5 cm
CT Ratio 1250/5, Compatible to bus size 6cm x 3 cm
CT Ratio 600/1, Compatible to bus size 6cm x 3 cm
CT Ratio 4000/5, Compatible to bus size 15cm x 5 cm
CT Ratio 600/5, Compatible to bus size 6cm x 3 cm
Current Transformers for Metering, Class 1, Type : Wound primary, Burden 10VA, INS Class: F, Frequency : 50Hz, IL : 0.66/3kV, HSV: 0.66 kV, as per IS2705 and IS4201
CT ratio 100/1 Approx size 10cm x 7 cm
CT Ratio 25/1
Control Transformers For Switchgear & MCC
VPI Transformers, Double wound, AN, Ratio : 415/110V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage : 110V, Rated Output: 2KVA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
VPI Transformers, Double wound, AN, Ratio : 415/24V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage : 24V, Rated Output: 1.5 KVA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
VPI Transformers, Double wound, AN, Ratio : 415/240V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage :240V, Rated Output: 3 KVA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
VPI Transformers, Double wound, AN, Ratio : 415/240V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage :240V, Rated Output: 2 KVA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
VPI Transformers, Double wound, AN, Ratio : 415/110V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage : 110V, Rated Output: 5KVA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
VPI Transformers, Double wound, AN, Ratio : 415/110V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage : 110V, Rated Output: 500 VA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
VPI Transformers, Double wound, AN, Ratio : 415/110V, Single phase, Freq : 50 Hz, Rated Primary Voltage : 415 V (taps ± 2.5% & ± 5%, Rated Secondary Voltage : 110V, Rated Output: 1 KVA, HSV: 0.66kV, IL : 0.66/3kV, Ins. Class : F as per IS: 12021/1987
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .