| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹8.6 L+₹81,610 (10.5%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹14.7 L+₹6.9 L (89.5%)Rejected-AOC 14 ILTIFATGANJ AMBEDKAR NAGAR UTTAR PRADESH 224145 UDYAM UP 04 0036158 | AMBEDKAR NAGAR | UTTAR PRADESH | 224145 | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
15 Oct 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-51 2020-21 REPAIR/MAINT AND CLEANING OF SEPTIC TANK SOAKAGE WELLS MANHOLES SEWAGE LINES AT SUB AREA TRANSIT CAMP R CENTRE UP AND DOWN CVY PRO UNIT TA BN ETC UNDER AGE B/R-I OF GE (NORTH) UDHAMPUR
2020_MES_379569_1
GE/U(N)-51/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹20,000
Yes
27 Oct 2020
21 Sept 2020
17 Oct 2020
21 Sept 2020
15 Oct 2020
3 Oct 2020
Amount
Systematically cleaning of the water closer including nahani trap, floor trap and gully traps by bamboo/wire/kandi rotary cleaner up to first mainhole any type of dia complete all as specified and as directed by Engr-in-Charge. Note : The contractor or his authorised rep shall collect the complaint of all blockage of sewage from complaint cell /Engr-in-charge daily and all complaint will be rectified by the contractor with in same day than the returned the complaint slip after completion of complaint and get recipt from concered JE/Enge-in-charge .If he fails to complete the work with in same day then recovery will be made @150.00 per complaint per day .
Systematically cleaning of the sewage lines including gully traps by passing ropes, Knots, bamboo/wire/kandi rotary cleaner etc for any type of dia of sewage pipe complete all as specified and as directed by Engr-in-Charge.
Cleaning and desludging of manholes of any size, shape and any depth including pumping out liquid waste if any, removing all solid waste materials such as stones, bricks, pipes, plastic etc, pluggings/ diverting of flow if required and removing the debries outside MD land etc including all precautionary and safty measures all as directed.
Cleaning and desludging of existing mini septic tank or Manholes or gullytrap of capacity n exc 10 Users and including inlet and outlet chambers and soakage well, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means , and removing waste material/sludge ( desludging n exc 0.5 cum and dewatering n exc 0.5 cum from each septic tank) etc to a distance n.exc 50 mtr including digging , burrying in groundcomplete all as specified and as directed by Engr-in-Charge. Note :-(i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor . (ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth. (iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers. (iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt.
Same as item No. 04 above but 100 users capacity ( desludging n exc 12.0 cum and dewatering n exc 12.00 cum from each septic tank) complete all as specified and as directed by Engr-in-Charge..
Same as item No. 04 above but 50 users capacity ( desludging n exc 6.0 cum and dewatering n.exc 6.00 cum from each septic tank) complete all as specified and as directed by Engr-in-Charge..
Same as item No. 04 above but 25 users capacity ( desludging n exc 4.0 cum and dewatering n exc 4 cum from each septic tank) complete all as specified and as directed by Engr-in-Charge..
Excavation in trenches in hard/dense soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth and getting out in any type of soil, complete all as specified and directed by the Engr-in-charge.
Ditto all as above item No. 8 but as in soft/disintegrated rock complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up 150mm bore Concrete / SGSW /AC drain pipes of any description and in any position.complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up 100 mm bore Concrete / SGSW /AC drain pipes of any description and in any position.complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete in ground floor and paving not exceeding 15 cm thickness ( below or above ground level) complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work/precast concrete article built in cement mortar any description complete all as specified and as directed by Engr-in-Charge.
150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed by Engr-in-Charge.
250 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed by Engr-in-Charge.
PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore.complete all as specified and as directed by Engr-in-Charge.
PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 250 mm bore.complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete.complete all as specified and as directed by Engr-in-Charge.
Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius, for man-holes septic tank/soake well etc in sewer works etc using old size bricks, built in cement mortar 1:4 , complete all as specified and as directed.
All as per item No 19 herein before, but except bricks. Note-Old bricks obtained against dismantling shall be used.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete, all as specified and directed by the Engr-in-charge.
15 mm thick cement plaster on the fair face of brick or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement,all as specified and directed by the Engr-in-charge.
Two coat of cement base paint over a coat of alkali resistant primer paint including preparation of newly plastered of wall complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:3:6 type C-1 ( Using 20 mm graded crushed stone aggregate ) as in coping,bed block, Gola etc including necessary formwork as required complete all as specified and as directed by the Engr-in-charge.
Cutting into existing manhole for connecting new drain pipes of 150 mm internal dia, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by the Engr-in-charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and directed by the Engr-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories).complete all as specified and as directed by Engr-in-Charge.
110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps, all as specified and directed by the Engr-in-charge.
110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and directed by the Engr-in-charge.
dito as above SI NO 30 but refixing only (except pipe) with clamp complete all as specified and as directed by Engr-in-Charge.
100 mm bore CI vent cowl including taking down old CI vent cowl of any type complete all as specified and as directed by Engr-in-Charge.
110 mm bore PVC (SWR) bends with access door any radius, all as specified and directed by the Engr-in-charge.
Cement concrete 1:2:4 type B-2 ( Using 40 mm graded crushed stone aggregate ) as in surface channel or drain including necessary form work etc, complete all as specified and as directed by the Engr-in-charge.
Demolition of rerinforced cement concrete of any description and in any position complete all as specified and as directed by Engr-in-Charge.
Pre-cast RCC 1 : 2 : 4, type B-1 (using 20 mm graded stone aggregate) in cover slabs for man holes with plain faces finished fair and smooth etc, set in CM 1 : 6 and including demolition of old slabs complete all as specified . Note:- each cover slab shall be engraved with CA No when concrete is green.
TMT bars 6 to 8mm dia cut to length bent to shape required, including cranking binding spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in mortar complete all as specified and as directed by Engr-in-Charge.
Factory made, heavy duty full body digital, paving coloured tiles of size 300x300x10mm thick for external use and including jointing with spacers with neat cement slurry and pointed in coloured epoxy tile grout to match the shade of tile laid over and including screed bed 15mm thick in cement mortor 1:4, complete all as specified and directed by Engineer-in-Charge.
sohtra and co
M/S R S CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .