Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.7 L+₹2.0 L (5.53%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.1 L+₹2.4 L (6.71%)Rejected-Finance 12 L I G PRITAM NAGAR PRAYAGRAJ U P PIN 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹40.2 L+₹4.5 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L4₹45.6 L+₹9.9 L (27.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
30 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
REPAIR MAINT OF SUMMER/WINTER APPLIANCES AND LT ELECTRIFICATION OF DAD AREA AT NEW CANTT PRAYAGRAJ
2024_MES_670549_1
8773/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE WEST PRAYAGRAJ
₹1 L
Yes
23 Nov 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
CEILING FAN / EXHAUST FAN
Taking down carefully Ceiling fan 1200/1400 mm sweep any size any capacity any sweep including dismantling of blade down rod fan for recognised defects at site or deposit to store complete all as specified & directed Note : (i) Refixing and reconnection etc of ceiling fan due painting /over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taking down shall be made good by the contractor at his own cost.
Opening up of ceiling fan for examination joint inspection preparation of inventory of each fan assessing & listing the nature and details for repair /overhauling /providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers whereas required and refixing in position complete all as specified & directed. Note:- All major repair such as replacement of Bush, bearing , condenser, shaft, connection wire , winding & painting will be measured & paid separately under respective item of Schedule 'A' here-in-after
Upto 4 Meters height.
Above 4 Meters height.
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete all as specified & directed. Note :- (i) Cost of transportation shall be borned by the contractor. (ii) All ceiling fans will be handed over to contractor through issue voucher duly showing details / number of ceiling fan and received back after necessary rewinding through receipt voucher duly signed by all Engr-in-charge, JE & contractor & countersigned by GE.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan 1200mm/1400mm sweep complete all as specified & directed.
S&F in replacement of gun metal bush suitable for ceiling fan any as per site requirements complete all as specified & directed
S & F condenser with PVC clamp of the following capacities:-
Taking down the ceiling fan down rod and replace with new down rod made out of GI tubing medium grade cutting, threaded and holes drilled both ends (dual arrangement), making holes – 02 Nos & painting with two coats of synthetic enamel white colour paint, fixing the down road to the fan and re-hanging the fan complete including their electric connections complete all as specified & directed Note- GI tubing will be measured and paid separately under respective item here-in-after.
S& F for providing GI tubing 15 mm bore heavy grade ISI marked as down rod for hanging of ceiling fan complete all as specified & directed
S& F GI tubing 50 mm bore heavy grade ISI marked for fixing on walls including PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in PCC block of size 230x230x150 mm for grouting ends of pipe & all fittings for hanging of Ceiling fans complete all as specified & directed.
M&L for fan hook made out of MS flat 50x6 mm suitably shaped to mount on 40 mm dia GI pipe including welded MS bar 10 mm dia half round shaped & necessary nuts & bolts complete all as specified & directed.
M&L for replacement of celling fan shaft complete of size & quality of 1200 mm sweep as per existing complete all as specified & directed.
Material and labour for replacement of U/S stator block made of laminated sheets of size and quality of 1200 mm sweep as per existing complete all as specified & directed.
S&F electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified & directed.
S&F fan blade set (set of three) made out of aluminium suitable for 1200 mm sweep ceiling fan, as per existing size and gauge complete all as specified & directed.
All as per srl item No 14 here-in-before but 1400 mm sweep complete all as specified & directed
M&L for replacement of ceiling fan shaft complete of size & quality of 1400 mm sweep as per existing complete all as specified & directed
M&L for replacement of unserviceable stator block made of laminated sheets of size and quality of 1400 mm sweep as per existing complete all as specified & directed
S & F Outer cover of ceiling fan as per existing shape and size complete all as specified & directed.
S & F PVC canopy of 1200/1400 mm sweep ceiling fan complete all as specified & directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5 Sqmm complete all as specified & directed.
S&F in replacement of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable as per site requirements complete all as specified & directed.
S & F of PCB for BLDC Ceiling Fan of capacity 1200mm sweep complete all as specified & directed.
EXHAUST FAN
Taking down carefully exhaust fan /wall fan /pedestal fan /air circulators any size any capacity any sweep including dismantling of blade down rod fan for recognised defects at site or deposit to store complete all as directed by Engi-in-Charge Note : (i) Refixing and reconnection etc of exhaust fan /wall fan /pedestal fan /air circulators & due painting /over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taking down shall be made good by the contractor at the own cost
Disconnecting & Taking down Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site transporting to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required all as directed by Engineer-in-charge. Note:- All major repair such as replacement of Bush, bearing , condenser, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
Refixing and testing Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site in position etc including provision of cable from Ceiling fan to Ceiling Rose PVC flexible three core cable of size 23/0.0076 copper conductor ISI Mar white in colour complete all as specified and directed Note : PVC copper wire/cable will be measured and paid separately under respective item.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5 Sqmm complete all as specified and directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 1.0 Sqmm complete all as specified and directed.
S&F in replacement of ball bearing suitable for following sizes complete all as specified and directed.
Exhaust fan/wall fan/pedestal fan upto 380mm sweep
Exhaust fan / pedestal fan / air circulator 450mm to 600mm sweep
Material and Labour for removing of burnt winding from exhaust fan/ Air Circulators/ Wall mounted fans/ pedestal fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete including transportation to work shop and bringing back to store and testing for following fans complete all as specified and directed. Note :- (i) Cost of transportation shall be borned by the contractor. (ii) All ceiling fans will be handed over to contractor through issue voucher duly showing details / number of ceiling fan and received back after necessary rewinding through receipt voucher duly signed by all Engr-in-charge, JE & contractor & countersigned by GE.
Exhaust Fan 9” sweep.
Exhaust Fan 12” sweep.
Exhaust Fan 18” sweep
Wall Mounted Fan 16” sweep.
S & F of revolving mechanism of wall mounted fan suitable for 400 mm sweep or as per existing type complete all as specified and directed.
S & F stator block of wall mounted fan as per existing design and material suitable for 400 mm sweep complete all as specified and directed.
S & F rotor block as per existing suitable for 400 mm sweep wall mounted fan complete all as specified and directed.
S&F in replacement of gun metal bush suitable for pedestal fan/ exhaust fan complete all as specified and directed.
Supply and fixing capacitors with PVC clamp of the following capacities:-
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint complete all as specified and directed.
Exhaust Fan 9”/12" sweep.
Exhaust Fan 18” sweep single phase/ three phase.
M&L for making circular holes suitable for fixing of 18” sweep exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site complete all as specified and directed.
All as per item No 38 above but suitable for 12” sweep exhaust fan complete all as specified and directed.
S&F in replacement of wall mounted fan blade suitable for 400 mm sweep fan as per existing complete all as directed by Engr-in-Charge.
S&F exhaust fan MS blade 12” to 15” as per existing complete all as specified and directed.
S&F exhaust fan MS blade 18” to 24” as per existing complete all as specified and directed.
M&L for MS front frame suitable for mounting of stays of 9" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled over a coat of red oxide primer complete with necessary fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement including taking down old unserviceable front frame complete all as specified and directed.
All as per Srl item No. 43 but suitable for 12" exhaust fan complete all as specified and directed.
All as per Srl item No. 43 but suitable for 18" exhaust fan complete all as specified and directed.
M&L for MS stay work (set of 4) suitable for 9" exhaust fan made out of not less than 20 x 3mm MS strip bent to shape complete painted with two coat of synthetic enamelled over a coat of red oxide primer complete with necessary fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement including taking down old unserviceable existing MS work complete all as specified and directed.
All as per Srl item No. 46 but suitable for 12" exhaust fan made out of not less than 25 x 4mm MS strip complete all as specified and directed.
All as per Srl item No. 46 but suitable for 18" exhaust fan made out of not less than 25 x 4mm MS strip complete all as specified and directed.
M&L for circular / rectangular framed shutters suitable for 9" exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than 0.6mm thick for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with necessary fixing accessories all as per existing & as per site requirement complete all as specified and directed.
All as per Srl item No. 49 but suitable for 12" exhaust fan complete all as specified and directed.
All as per Srl item No. 49 but suitable for 18" exhaust fan complete all as specified and directed.
M&L for replacement of exhaust fan shaft for 9/12 " complete of size & quality as per existing complete all as specified and directed.
S&F in replacement of MS louvers shutters on wall suitable for 380/450 mm sweep exhaust fan including suitable size of nut, bolts & washer complete all as specified and directed.
S&F in replacement of exhaust fans PVC body of size 250mm sweep single phase 230 V AC , 1400 RPM Range complete with louvers shutter including taking down the old unserviceable one and depositing the same in MES yard for further disposal complete all as specified and directed.
S&F in replacement of Wall mounting fans PVC body of size 400 mm sweep single phase 230 V AC , 1400 RPM Range complete with louvers shutter including taking down the old unserviceable one and depositing the same in MES yard for further disposal complete all as specified and directed.
LT ELECTRIFICATION
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil complete all as specified & directed.
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified & directed.
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified & directed.
M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified & directed. Note:- Punned thickness of sand shall be measured for payment.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
Taking up or down 50/80 mm bore steel water tubing and connections including cleaning for refixing complete all as specified and directed.
M&L in replacement for GI tubing 'light grade' of 50 mm dia with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps complete all as specified & directed.
M&L in replacement for GI tubing 'light grade' of 80 mm dia with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps complete all as specified & directed.
M&L for boring under road horizontally of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soil complete all as specified and directed.
Disconnecting & dismantling of damaged/burnt/ unsv LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor of any size /make laid complete all as specified and directed
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 300 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 150 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 120 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 95 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 50 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 25 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Supply & laying in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene XLPE LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 10 Sqmm 2 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint of size 16 to 35 Sqmm and 3.5 / 4 core using straight through joint Hot shrink type and making connection of LT cables, meggering & restoration of electric supply complete including jointing material complete all as specified & directed.
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint of size 50 to 95 Sqmm and 3.5 / 4 core using straight through joint Hot shrink type and making connection of LT cables, meggering & restoration of electric supply complete including jointing material complete all as specified & directed.
S&F in replacement aluminium cable lugs of size 16 Sqmm & stud hole dia 10/ 12 mm complete all as specified and directed.
S&F in replacement aluminium cable lugs of size 25 Sqmm & stud hole dia 10/ 12 mm complete all as specified and directed.
S&F in replacement aluminium cable lugs of size 35 Sqmm & stud hole dia 10/ 12 mm complete all as specified and directed.
S&F in replacement aluminium cable lugs of size 50 Sqmm & stud hole dia 10/ 12 mm complete all as specified and directed.
S&F in replacement aluminium cable lugs of size 70 Sqmm & stud hole dia 10/ 12 mm complete all as specified and directed.
S&F in replacement aluminium cable lugs of size 95 Sqmm & stud hole dia 10/ 12 mm complete all as specified and directed.
M&L in replacement of MCCB, 4 pole, 415 Volts, 63 Amps, 16 KA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection and testing complete all as specified and directed.
M&L in replacement of MCCB, 4 pole, 415 Volts, 125 Amps, 16 KA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection and testing complete all as specified and directed.
M&L in replacement of MCCB, 4 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection and testing complete all as specified and directed.
M&L in replacement of MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection and testing complete all as specified and directed.
M&L in replacement of MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection and testing complete all as specified and directed.
M&L in replacement of MCCB, 4 pole, 415 Volts, 400 Amps, 36 KA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection and testing complete all as specified and directed.
M&L for replacement of ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 250 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.. Make Havells cat Part No IHCNFO0250 or equivalent make as specified in P.S.
M&L in replacement of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 315/320 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.. Make Havells cat Part No IHCNFO0320 or equivalent make as specified in P.S.
S&F in replacement of sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting MCCB of 160A Amps 4 pole duly fixed on wall with all fixing arrangements all as directed.
S&F in replacement of sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting MCCB of 250A Amps 4 pole duly fixed on wall with all fixing arrangements all as directed.
S & F MCB TPN 63 A,'C' Curve,10KA rupturing capacity complete all as specified and directed.
M & L for locating UG cable fault using Microprocessor based fault locator suitable for low/medium and high voltage up to 11KV , XLPE/PVC/PILC of Al/Cu cables under trenches / RCC surface & on wall for finding OC/SC/Flahing faults with any one of the suitable methods Time domain reflect meter method (TDR) / Secondary impulse Method (SIM) / Impulse Current method (ICM)/ decay Method to achieve pin point fault location up to 5 Km distance complete all as specified and directed.
M & L for Cleaning, dusting and servicing LT panel , MCCBS, Bus bars tightening cable connections, providing lugs , cable glands and replacing of worn out parts such as busbar spout , spacers, hinges, locks, and connected items/Mechanical parts etc for its smooth functioning including Internal spray Painting of the panel ,Insulation of busbar , replacement of control wiring, cleaning the disturbed area beneath the LT panel and removing vegitation , debris etc all as specified and directed by the Engineer in charge. (Note:- Rate quoted deemed to include for removing and replacing of defective items where required, complete all as specified and directed.
M & L for servicing of ACBs 800/1000A rating by disconnect and taking out the breaker after taking power shut down of the respective panel and overhauling/ servicing the ACB by opening all parts and cleaning of electrical contacts with CTC/rust remover, lubricating electrical moving parts with petrolium jelly and mechanical moving parts with grease & applying Becktrol red solution to the surface of the bus bars and spouts, applying Monoplast compound at the bus bar joints after tightening of joints and replacing defective spare parts like springs/ bolts/ nuts/ washers etc, including testing, calibrating , refixing the circuit breaker and make functional all as directed and specified
Disconnecting electrically items and cleaning of LT Panel for Internal/External Spray Painting complete of any capacity after preparation of surface and applying two coats of synthetic enamel (smoke grey) paint and old steel surface , replace the Danger notice plate, Insulation of busbar etc complete all as specified and directed.
S & F in Replacement of Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size, fixed as in repairs, complete all as specified and directed.
S & Fix in replacement of air circuit breakers 1000 A, 50Ka 4 pole thermal magnetic release type DN1 with breaking capacity 1 Sec fixed to existing LT panel by taking down the existing un-serviceable ACB complete all as specified and as directed. Make L&T cat part No SL95503 or equivalent make as specified in P.S.
S & Fix in replacement of air circuit breakers 800 A, 50Ka 4 pole thermal magnetic release type DN1 with breaking capacity 1 Sec fixed to existing LT panel by taking down the existing un-serviceable ACB and cutting as required for proper fixing & connection complete all as specified and directed. Make L&T cat part No SL95502 or equivalent make as specified in P.S.
S & F in replacement of Digital Multifunctional Panel meter for measuring Voltage 0-500 V min, Current , P.F etc including necessary P.T & C.T's with all connected accessories complete all as specified and directed.
S & F in replacement of Digital Ammetr 0-600A (min) , with CT's, all connected accessories including connecting up and testing complete all as specified and directed.
S & F in replacement of LED indicator lamp 240 V , with suitable colour Red/Blue/Yellow/Amber/Green and connected accessories complete all as specified and directed.
S & F in replacement of push button switch with NO/NC contacts 415 V ,6A , with add on Aux Contacts and connected accessories complete all as specified and directed.
Cutting/pruning of tree branches along /around over head LT line at places within a radius of 2 mtr from fasted conductor and removing from site complete all as specified and directed.
Trimming/cutting of tree /removal of bushes/removal of vegetation growth/cutting trunk portion protruding over ground, digging out roots arround 2 mtr radius of LT panel and removal from site complete all as specified and directed. Note : This job may be repeated after three month at the same location.
M & L for applying two coats of aluminium paint over a coat of red oxide on Steel tubular pole of following length including cross arms and clamps except embedded portion of pole in ground including copping after removing old painted surfaces by scraping of poles complete and making colour brand with synthetic enamel paint of approved colour up to 1.2 mtr from coping level including numbering of poles in red colour paint and painting of coping complete all as specified and directed.
Disconnecting of OH line of ACSR conductor/GI earthing wire, opening of binding wires, jumper connections any size and restringing, tightening of conductor with suitable line vice, replacing all worn out jumper connection with suitable conductor, re-tightening and straightening all cross arms, insulators, clamps etc including replacement of all worn out nut bolts and washers complete all as specified and directed .
S&F in replacement Pin type , porcelain , vitreous, white, brown or green insulator including one galvanized mild steel spindle , two galvanized iron washers and one galvanized iron nut ,100mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
S & F of LT spacer 4 ways made out of PVC material complete all as specified and directed.
Dismantling of stay assembly complete all as specified and directed.
S & F of Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x230x6 mm, stay bow, loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 complete all as specified and directed.
M & L for earthing complete with Galvanized Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to and including GI iron strip of size 32x6 mm flat by means of GI bolts, nuts, and washers, protected by 40mm bore GI light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggregate) including TMT reinforcement 80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-I and all as directed.
Schedule of Credit (MINUS) Rs. 121563.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
PITAMBARI TRADERS (BID ID -3106879)
M/s SINGH CONTRACTOR WORKS (BID ID -3105511)
DINESH ELECTRICALS (BID ID -3120864)
RAMESH ENTERPRISES (BID ID -3106923)
Ambrish Builders (BID ID -3122574)
M/S Aarav Construction (BID ID -3106372)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .