Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 CrAccepted-AOC A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹20.3 Cr Quoted ₹20.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹20.5 CrRejected-Finance B 604 VASUNDHRA APARTMENTS PLOT NO 16 SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹20.5 Cr | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹20.7 CrRejected-Finance | ₹20.7 Cr | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹21.2 CrRejected-Finance | ₹21.2 Cr | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹21.6 CrRejected-Finance | ₹21.6 Cr | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹20.6 Cr
EMD Value
₹13.5 L
Closing Date
1 Nov 2023, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ CE Delhi Zone Delhi Cantt-10
CONSTRUCTION OF 32 RESIDENTIAL QUARTERS (16-TYPE IV (SPL) AND 16 TYPE V) FOR JUNIOR LEVEL IDAS OFFICERS AT 0.565 ACRES OF LAND AT BRAR SQUARE, DELHI CANTT UNDER GE(P) EAST DELHI CANTT-10
2023_MES_616730_1
CEDZ/TOKEN-18 OF 2023
Open Tender
Civil Works
540 days
Delhi Cantt
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
GE (P) East
₹13.5 L
Yes
10 Nov 2023
18 Sept 2023
3 Nov 2023
18 Sept 2023
1 Nov 2023
25 Oct 2023
18 Sept 2023 - 10 Oct 2023
Amount
Lump sum price worked out by the contractor for Schedule 'A' Section-I (Bldg Work)(Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-II (Internal Water supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-III (Exacavation and Earth Work) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IV (Internal Electric supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-V (Demolition and Dismantling) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VI (DG Set) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VII (Lift) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VIII (Fire Fighting) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IX (Lightning protection) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-X (Road, path and culvert) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XI (External Water Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XII (External Electric Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIII (Sewage Disposal) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIV (Area Drainage) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XV (Boundary Wall, Gate and Fencing) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XVI (Rain Water Harvesting) (Ref pre priced Schedule attached seperately)
Description of Work / Item(s)
Amount
INTERNAL WATER SUPPLY
S&F CP Brass two way angle valve, Cera Cat No F-1016211, Hindware Cat No F-360055 or Equivalent in Jaquar complete all as specified and directed.
S&F CP Brass sink mixture wall, jaquar Cat Part No COP309PM, Cera Cat No F-1016501 ,Hindware Cat No F570027 complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY
S&F LED Bulb of 9 watt Oval diffuser to give glare free light, IP50 of lumen output should be greater than 1100 lumen, CCT 4000-5700, CRI>=70, THD must be less than 10%, Power factor more than 0.9, working voltage 140-270V, life time should not be less than 25KHr complete all specified and directed.
S&F Exhaust fan 300 mm sweep, copper winding,metal body, four metal blades BEE approved/ISI marked, air delivery shall not be less than 1600 CMM at 1400 RPM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable fixed in position as recommended by manufacturer complete all as specified.
S & F LED bracket light fitting 1x 12 W, 220V,AC LED Lamp decorative wall mounting fixture made up of Aluminum body including LED 12 watt with System level efficacy of the Luminary is > 120 lm/W , Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply Installation, testing & comissioning of Integral LED 2ft, 10 watt 220 V, luminaire made of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 2000 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 16W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The minimum dimensions (± 5mm) of the batten shall be 44mm(±5mm) X 51mm (±5mm)X 585mm(±5mm). The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips)/ Wipro/Regent complete all as specified and directed.
Supply & fixing of suspended/Surface mounted Cylinderical Downlight, 12w, 1500 lm, CCT 5700K, CRI>80, Efficacy 2120≥m/W, Surge 4Kv internal, THD ≤10% (At Full Load), Extruded aluminum housing, white/Black finish, Product Dia 100mm, Height 205mm, Life L70B50 @ 50K Hrs. @ 45 Degree Ambient temp. The product should be EMI/EMC compliant and ripple <5%. The product should have option of 24°, 36° and 60° beam angles to choose from as per the application. operating temperature should be -10° to +45°; operating volateg range 140-270. The LED driver should comply to IEC61347 -2 - 13, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. Product complying to above specs in Signify, LT or Endo complete all as specified and directed
Supply Installation,testing & comissioning of intregral LED 4ft luminaire of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 18 Watt LED with colour consistency SDCM< 5,CRI> 80 and CCT of 6500k, Luminaire shall be desihned to emit at least 2000 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 16 W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ desighn ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 140-270V AC current Ripple<5% internal surge protection should be minimum 4KV, electrical insulation class should be Class I &driver should be of class B serviceablility. the PIR sensor should be able to dim the fixture to 50% in case of no movement, sensor should have a detection angle of 60 degree and luminaire should be at least IP20 & IK02 rated. the minium dimensions (+5mm) of the batten shall be 44mm(+5mm)x51mm(+5mm)x1221mm(+5mm). The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & "FAT" before dispatch as per IS 10322. the successful bidder must submit the NABL accredition certificate for luminaire manufacturer along along with technical bid. the LED Luminaire & It's driver both should be BIS registered successful bidder shall submit the following reports before supply of material for approcals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips/Wipro/regent).
S& F Modular power socket suitable for Air conditioning with 20 Amp MCB, SP 240 volts AC including power plug (top) complete all as specified and directed.
S & F Distribution Board double Door made out of CRCA mild steel sheet surface not less than 1.2mm thickness with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 4 way as incomer 8 modules, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCBs and SPD as a incomer etc and making all necessary connections complete all as specified and directed.
S & F Distribution Board double Door made out of CRCA mild steel sheet surface not less than 1.2mm thickness with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 8 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCBs and isolators etc and making all necessary connections complete all as specified and directed.
Supply and fixing of 40 Amps MCB TPN 40 Amps, 240V 10KA 'C' curve for 230V in the SPN MCB DB complete with connection testing all sepecified and directed.
Supply and fixing MCB, 415 V 10KA 'C' curve , of 4Pole MCB 63 Amp current carrying capacity in the TPN DB as incomer complete with connection.
Supply and fixing RCBO, 415 Volt, 40 Amp, 30mA, 10 KA of 4 pole in the TPN DB as outgoing all as specified.
Supply and fixing RCBO, 230 Volt, 40 Amp, 30mA, 10 KA of double pole in the SPN DB as outgoing all as specified.
S & F of Fresh air ventilation fans of 250 mm sweep, speed 1280 RPM, Air delivery not less than 780 m^3 / Min, rated voltage 220-230, 50 Hz, Min two years warranty complete all as specified and directed.
S&F surface mounting LED building security light fitting fitted in high pressure die cast aluminium housing not less than 18 W including fabrication of GI bracket 25mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut bolts & washer etc. Fixture should have minimum efficacy at system level >=100 lumens/Watt, life of fixture not less than 50K Hrs,Ripple<5%,UGR<19,minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 ,THD<10% @ 240v Ac with IP 66 protection. An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed.
S & F Transparent Acrylic cover for fixing smart prepaid meter of suitable size (1Ph & 3 Ph) including hinges and arrangement for sealing the box complete all as directed.
Supply and installation of a Surge Protective Device (SPD) , 40Amp with T2/20KA, 4-pole, CT1 protection mode. TPN DB as incomer complete with all necessary connections. Make : Legrand/Siemens/Schneider
DG SET
Supply, installation, commissioning, and testing of a static Silent Diesel Engine-driven generating set, manufactured by the OEM, capable of delivering not less than 57 KVA at 415 volts (AC, 3-Phase, 4-wire system of supply), 50 Hz frequency, and a minimum power factor of 0.8 (lagging). The DG set comprises a diesel engine coupled through a flexible coupling to a matching alternator, all mounted on foundation pads on a common base frame. This entire assembly is then installed within a CPCB approved acoustic enclosure, ensuring full conformity with and certification according to as latest CPCB norms IV. The scope of work includes the supply of a control panel standardized by the manufacturer, a fuel tank complete with mounting arrangement, inlet and outlet connections, return oil arrangement, and an exhaust pipe made of MS pipe with a length exceeding either 35 meters or as required based on ground requirements. The exhaust pipe should also be complete with insulation of alluminium cladding & glass wool and comprise of the following:- (a) Diesel Engine (Prime Mover): The engine should operate at a rated speed of 1500 RPM, delivering suitable HP as recommended by the manufacturer but not less than 74 HP as per ISO8528-1. It should be a water-cooled engine, equipped with a 1x 100 AH 12 Volts electric battery for starting. The engine must include a flywheel and all standard fittings/fixtures according to manufacturing practices. The engine should come with a suitable engine control panel featuring a tachometer, lubricating oil temperature and pressure gauges, water temperature gauge, and a digital frequency meter. It should also include safety shutdown features. Furthermore, the engine must have a self-starter, dynamo, fuel tank, etc., and it should conform to IS 10002:1981, ISO 3046, and BS-5514 standards. The engine should be capable of providing an electrical output of not less than 57 KVA at a power factor of 0.8.
(b) Alternator: The AC alternator should be a self-excited, self-regulated, self-ventilated, brushless design, conforming to BS 2613/4722-2001 standards. It should operate as a 3-phase system at 415 volts, 50 Hz, with a 4-wire system output of not less than 57 KVA and a power factor of 0.8 at 1500 RPM. The alternator's efficiency should meet the standards outlined in IEC 60034-1. The insulation of the alternator should be rated as class 'H,' and it should have a proper enclosure conforming to IP 23/TEFC standards. The alternator should come complete with an Automatic Voltage Regulator (AVR) capable of +1% voltage regulation. It should be directly coupled to and matched with the above-mentioned engine, capable of handling an overload of 10% for one hour within 12 hours of operation. (c) Anti-Vibration Pads: These pads are intended for mounting the engine-alternator assembly on the base frame/plate to minimize vibrations. (d) Base Frame: The base frame should be constructed using structural steel in accordance with the manufacturer's recommended design and specifications. (e) Battery: One unit of a 12V battery with a capacity of 100 AH, DC charged and sealed, maintenance-free, complete with a suitable capacity. This includes the provision of an engine/alternator protective foundation with an LCD display. (f) Control Panel and Energy Meter: One control panel along with an energy meter.
(g) Acoustic Enclosure: The enclosure must be of integral type and should strictly adhere to the latest CPCB norms IV, ensuring that it meets the stringent MoEF/CPCB norms, maintaining noise levels at 75 dBA @ 1 meter at 75% load under free field conditions. The temperature rise within the enclosure should not exceed 5° to 7°C. The acoustic enclosure should be constructed using 16 SWG CRCA sheets, painted in Munsel green shade, with a structural/sheet metal base frame in black. The enclosure should be equipped with high-quality noise-absorbent and fire-retardant grade acoustic insulation material (Foam) that complies with IS 8183. Additionally, it should undergo an 11-tank pretreatment process and feature UV-resistant powder coating on all parts to withstand extreme environmental conditions. The enclosure should have four hinged doors, one of which includes a glass window. Additional components include: (i) Exhaust Pipe: The exhaust pipe should be of the silence absorption type, non-resistance, residential, and covered with asbestos rope lagging. The length of the exhaust pipe should exceed either 35 meters or be as required based on ground requirements. The exhaust pipe should also be complete with insulation of alluminium cladding & glass wool. (ii) Internal Wiring: Internal wiring should be done with PVC copper conductor cables (FRLS type), marked as per IS 694 (2010), and equipped with fluorescent lamp fittings. (iii) Fuel Tank: The fuel tank should have a capacity of at least 165 liters and should include provision for an external fuel filling arrangement outside the enclosure. This allows for 16 hours of operation. The tank should be constructed using 14 SWG CRCA MS sheet, duly powder-coated, and should be equipped with a float, gauge, and fuel float switch. (h) Catalogs and Manuals: Three sets, including operation and maintenance manuals, spare parts lists, and overhauling manuals.
(j) Control Panel (AMF Panel): The control panel should be designed to match the requirements of the DG Set. It must be manufactured using 14/16 gauge CRCA sheet and powder-coated for a weatherproof and durable finish. The control panel should consist of the following components, as per manufacturer's norms: (i) PCC-Key Switch / Autostart Generator Set Controller. (ii) Multifunction Meter displaying parameters such as Voltage, Current, Frequency, Water Temperature, Oil Pressure, KVA, and KW. (iii) Contactors with HRC (High Rupturing Capacity) fuses of suitable ratings, current transformers, AMF logic Battery Charger, Aluminum Busbar of suitable capacity, and indicating lamps. (iv) A standard foundation as per the manufacturer's specifications, along with anti-vibration foundation pads of approved make and suitable capacity.
EXTERNAL WATER SUPPLY
M&L for provision of MS header of size 250mm bore with end plate and length 3 mtr inclduing incoming supply 2 nos with MS pipe 100 mm and outgoing with MS pipe 150 mm with flanged end and end plate cover, nuts bolts, etc for provision of sluice valve all as specified and directed.
Supply, laying, jointing & testing centrifugally cast (spun) Ductile Iron pressure pipes, 100mm Dia, socketed & spigot ends, class K-7 with push on joints ISI (IS:8329-2000) marked in any length, laid in trenches all as specified and directed.
Supply fix, connect and test sluice valves of 100 mm bore, class PN-1.0, cast iron body with Stainless steel spindle non rising type and cast iron wheel head both ends flanged IS-14846 marked, complete with neoprene rubber gasket joints and nuts, bolts (high tensile) washers etc. complete all as specified and directed. Make : Kirloskar/Leader/Zoloto
Supply fix, connect and test sluice valves of 150 mm bore, class PN-1.0, cast iron body with Stainless steel spindle non rising type and cast iron wheel head both ends flanged IS-14846 marked, complete with neoprene rubber gasket joints and nuts, bolts (high tensile) washers etc. complete all as specified and directed. Make : Kirloskar/Leader/Zoloto
Supply fix, connect and test sluice valves of 80 mm bore, class PN-1.0, cast iron body with forged brass spindle non rising type and cast iron wheel head both ends flanged IS-14846 marked, complete with neoprene rubber gasket joints and nuts, bolts (high tensile) washers etc. complete all as specified and directed. Make : Kirloskar/Leader/Zoloto
Supply, installation , testing & commissioning of monobloc type MI-C series centrifugal pump having discharge capacity 12LPS at 60 mtr head complete with induction motor of suitable HP upto 20, 3 Phase 415 volt 50Hz mounted on common base frame complete all as specified and directed.
M&L Ductile Iron fittings, IS-1538 marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle/radius and straight connecting pieces, any type of end (flanged/socketed/spigot as reqd at site) but all ends flanged, size of pipe upto 150 mm bore, complete all as specified.
M&L for construction of brick masonary valve pit/chamber of size 900mmx600mmx1000mm (internal dimension), including necessary excavation and earth work, PCC, plaster in CM 1:6 on inside and outside (above ground), MS angle iron 40x40x6mm thick frame work, hold fasts, CRCA MS sheet cover 3mm thick, duly painted with one coat of bituminious paint of approved quality, handle and locking arrangements complete including provn of Godrej(Freedom) lock, all as specified and directed
Supplying & installation, Fabrication, testing and commissioning of Electrical motor control panel for Lift of cubical construction double door panel wall mounted indoor type fabricated 2mm thick CRCA sheet compartmentalized with hinged lockable doors, dust and vermin proof, powder coated, single core PVC insulated FRLS copper conductor cables, having suitable mountings for switchgears and accessories and internal control & power wiring with suitable rating PVC insulated FRLS copper conductor, earth terminals numbering etc suitable for operation on 415V 3 phase 50 Hz AC supply with enclosure protection class IP 55 with 200 Amp rating Al bus bar etc complete as required. (a) Incoming :- (i) MCCB 4 pole 63Amp 16 kA 415V(incomer for Lift ) - 01 Nos (b) Outgoing :- (i) MCCB 4 pole 40 Amp 25 kA 415V(iOutgoing for Lift ) - 02 Nos (ii) Energy meter - 01 Set (iii) Indicating Lamps : 01 set
EXTERNAL ELECTRIC SUPPLY
Supply and installation of Ring main unit one incoming two outgoing SF6 filled gas insulated load break switch of 12 KV ,630 Amp to be connected at one side of connecting rmu (Make-Siemens/Schneider/ABB), FBX-CCT2 with short circuit withstand current upto 21KA, short circuit duratiion 3 Sec, Power frequency withstand voltage 38 KV rms, lightning impulse withstand voltage up 95KV peak and IP54 degree of protection
Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station ,400kVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. Make : Siemens/Schneider/ABB. Note : CSS shall be from OEMs only . Licensed System Integrators are not allowed to supply. Package substation will have the following equipment :-
HT SWITCHGEAR 11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of 1 nos. fixed manual operated Vacuum Circuit Breaker Module along with aditional cable module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. Vacuum Interrupter,RMU,LT panel and CSS shall be of same make to ensure life cycle optimization. (a) Microprocessor based communicable IDMT Relay for Circuit Breakers - Self Powered along with series trip coil. (b) Capacitive voltage indication fixed type system with LED. (c) SF6 Gas pressure indicator. (d) Padlocking facility. (e) Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos. (f) All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set
Supply, install, testing and commissioning of indoor type transformer capacity 400 KVA, 11/0.433 KV, with the Indian Standard IS:11171 (1985), including all relevant amendments. It operates as 3 Phase, 50Hz, cast resin DRY type transformer with Double wound copper windings ensuring efficient performance. Its vector group configuration is Dyn11, and it boasts Class 'H' insulation. The HV side allows for voltage variation from +5% to -5% in 2.5% steps, facilitated by off-circuit tap links. The transformer can withstand a temperature rise in winding over an ambient temperature of 50°C, up to 115°C. Maximum total losses at 50% loading at rated 145°C (AN) are 2.38 KW (maximum) or as per the latest ECBC-2017 guidelines, and at 100% loading at rated 145°C (AN) are 6.040 KW (maximum) or as per the latest ECBC-2017 guidelines. The % impedance is 4.5% with a tolerance of +/- 10%. It has a Basic Insulation Level (BIL) of 12KV/28kV/75kVp and uses the AN (Air Natural) cooling method, complying with the latest ECBC-2017 code. Standard fittings are included as part of this specification. (a) Winding Temperature Indicator scanner. - 1 No. (a) Winding Temperature Indicator with 1 alarm and trip contact. - 1 No. (b) Surge arrestor in the HV side. - 1 Set (c) R&D Plate, (d) Lifting lugs, (e) 02 Nos. Earthing Terminal, (f) Degree of Protection: IP-23 (indoor). Transformer Make: Siemens/Schneider/ABB(Hitachi)/Raychem/TMC/Ames Impax/ITE Gurgaon
OUTDOOR ENCLOSURE Outdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.
Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel outdoor type of 1200x1500x600mm size and fabricated from 3.15 mm thick CRCA sheet steel with necessary MS angle iron frame work(50X50X6mm), weather proof, vermin proof, suitable rating Aluminium bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size conforming specification as per IS 5039. The panel should be CPRI approved and having IP 54 ingress protection including necessary foundation for mounting all as specified and directed by Enginer in charge. Make: As per approved.
Incoming :- MCCB 4 Pole -160Amps, 25 kA, 415V -01Nos Outgoing :- (i) MCCB 4 Pole - 63 Amps, 16kA -02 Nos ( outgoing for Pump House n terrace Pump) (ii) MCB 2 Pole - 32 Amps, 10kA -01 Nos ( outgoing for Security Light) (iii) MCCB 4 Pole - 63 Amps, 16kA -02 Nos ( outgoing for Lifts) (iv) LED indication lamp -01 (R Y B, set of three) (v) Busbar: 240Amps, System Voltage: 415V, 50 Hz, 4W +E (vi) Analog Timer-01No (vii) Multifunction meter of class 0.5 accuracy. - 1 No. along with suitable CT
Steel tubular swaged type swan neck poles of height 7.5 mtr complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-28 (6.0 metres above the ground) as per IS 2713/80 complete all as specified and directed.
Supplying and fixing in position new sheet moulding compound (SMC) junction box of size 280 mm X 170 mm X 130 mm depth. The box shall provided with and including 2 Nos, 32 Amps aluminum bus bar mounted on porcelain insulators and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI clamps,nuts,bolts & washers complete all as specified and directed.
Making hole under Road with trenchless technology manually for passing 80/50/40 mm dia GI pipe for protection of cable complete all as directed by Engr-In-Charge.
“S&F LED street light fitting of 35 Watt, including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece, high pressure die cast aluminium alloy, monolithic construction totally enclosed, dust and water proof with minimum IP65 protection as per IS-10322-1982(Part-I) with latest amendments and input voltage range 140-300 VAC, frequency 50-60Hz, P.F should be more than 0.9 with THD(I) less than 10%, cool white color and. Fitting should be provided with min 4 KV surge protection, constant current constant voltage driver, high voltage withstanding capacity upto 300 VAC and also have double phase protection, no load, open circuit and short circuit protection, Light fitting suitable for ambient temperature from minus 10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure minimum IP65 degree protection. The lumen output shall not be less than be 110 lumens per watt, life should not less than 40Khr, color index 6000K and must be certified by the relevant test report Fitting should fixed on pole using and including 1.2m long 40mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making electrical connection using 1.5sqmm, 3 core multi-stranded copper conductor PVC insulated and over all PVC sheathed cable form light fitting to junction box complete all as specified and directed.
SEWAGE DISPOSAL
S & F of SFRC manhole cover with frame HD 100 mm thick complete all as specified..
AREA DRAINAGE
S&F SFRC perforated medium duty drain cover 100 mm thick complete all as specified and directed.
SECURITY WALL
S & F concertina coil 450 mm dia, with SS sharp edges, fixed at the top of security wall all as specified and as directed.
RAIN WATER HARVESTING
M & L for drilling 250 mm dia bore hole by DTH cum Rotary at any depth below the GL in any kind of soil / rock up to 40 M depth incl disposal of surplus spoil to a distance not exc 50 m away all as specified and as directed.
S & F self perforated unplasticised PVC pipes 250 mm dia of pressure rating 10 kg/ sqcm fixed complete to walls or in floors complete all as specified.
FIRE FIGHTING
Supply, erection, commisioning and testing of Gun Metal Air Release Valve 25 mm on wet riser, with shut off Forge Brass ball valve.
Supply, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 250 mm with a canopy , door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 7.5 mtrs hose, weather proof, Finished with P.O. fire red color (Sample to be approved prior to entire supply) complete all as specified and directed.
Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system.The panel shouled be suitable for automatic operation for the fire pump as per the specifie parameter. The panel shall be copletely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Contineous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable enteries complete all as specified and directed .
Supply, installing, testing and commissioning of manual fire alarm control panel of 16 zone complete all as specified and directed.
S&F of 6 Kg ABC type Extinguisher (Dry Powder Chemical) with all connected accessories complete all as directed by Engr-in-Charge.
S&F of 4.5 Kg CO2 type Extinguisher (Dry Powder Chemical) with all connected accessories complete all as directed by Engr-in-Charge.
CCTV & INTERCOM
SUPPLY Cost of Complete HD Outdoor IP Camera (Fixed) with mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete HD Indoor IP Camera (Fixed) with mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete 30 TB Network Recorder Attached Storage for 30 days recording with mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges, FAT charges up to destination complete all as directed by Engr-in-Charge.
Supply network cameras supported,Up to 8 Megapixels resolution recording Support 1-ch HDMI, 1-ch VGA, HMDI at up to 4K(3840x2160) resolution detection alarm and VCA search,Support H.265/H.264/MPEG4 video formats complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete 42” TFT /LED FULL HD with mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges, FAT charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete CCTV Equipment Rack (42U) with mounting/installation accessories to house all the servers,switches for CCTV and fencing system inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete 12 core, SM Optic Fibre Communication cable with the required termination of all points of camera locations and wherever required including supply of requisite LIU,patch chords,pvc conduits etc with all mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete 40 mm dia HDPE pipe with mounting/ installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges, FAT charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete indoor UTP Cat 6 cable system along with requisite PVC conduit, patch chords, patch panels,gang boxes, cable trays, RJ-45 connectors,face plates required in control room for connectivity with servers and workstations wherever required with all mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete 3 X 1.5 sq mm armored PVC sheathed copper conductor with mounting/installation accessories , inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery
SUPPLY Cost of Complete Modular Online 5 KVA modular UPS with accessories and 30 minutes Backup time with mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges, FAT charges up to destination delivery complete all as directed by Engr-in-Charge.
SUPPLY Cost of Complete IP65 Outdoor Enclosure with accessories and mounting/installation accessories, inclusive of CST/VAT, Excise, All Indian, Overseas Taxes/ duties / levies, all handling/forwarding, loading/unloading charges, freight, insurance, Octroi, Road Permit Charges up to destination delivery complete all as directed by Engr-in-Charge.
Training Installation and Manuals for CCTV Camera complete all as directed by Engr-in-Charge.
Supply of Chasis Main system Model No IP7WW SL2100 complete all as directed by Engr-in-Charge.
Supply of CPU Board Model No IP7WWC1 complete all as directed by Engr-in-Charge.
Supply of Analog Extension Board Model No IP7WW 308U-A1 complete all as directed by Engr-in-Charge.
Supply of Digital Extension Board Model No IP7WW 008U-A1 complete all as directed by Engr-in-Charge.
Supply Expansion Board Model No IP7WW EXIFB-C1 complete all as directed by Engr-in-Charge.
Supply Expansion Board Model No IP7WW EXIFE-C1 complete all as directed by Engr-in-Charge.
Supply of Panasonic Basic Phone complete all as directed by Engr-in-Charge.
Installation and sevices for intercom system complete all as directed by Engr-in-Charge.
AUTOMATIC BOOM BARRIER
Supply ,Installation,Testing and commissioning of automatic boom barrier with 3 mtrs length along with safety sensor complete.The barrier shall be design to withstand direct impact force,five tonne vehicle travelling at the speed of 30Km/h alongwith heavy duty operation mechanism including necessary foundation/ fixing arrangements ,optical beam sensor ,access control operation, high range receiver,high range remote control,push button ,photosensor for human safety,loop detector, bar with protective rubber profile ,flash point , manual release key in case of power failure ,for better visibity shall be aluminium with red reflective strip and all connected accessories ,including necessary foundation as per OEM instructions complete all as specified and as directed. Make:- Godrej /Brosis/Avon/Gunnebo/BGI Engitech Note:- Civil Work and electric work for installation of above equipment will be scope of the Firm.and shall also confirm the followings;- (i) Clear Passage-3 Mtrs (ii) Length of the Boom-Not lett than 3 Mtrs. (iii)Height of pole from the ground level-0.90 Mtrs. (iv) Desirable Operation time-8 to 10 Sec (Max)
Pooja Singla Builders And Engineers Pvt Ltd
B D Raizada Projects Pvt Ltd
SRISHTI INFRASTRUCTURES LIMITED
Ktech Engineer Builders Co. Pvt. Ltd
Global Enterprises
Mathra Dass Ahuja and Sons
M P TYAGI ENGINEERS AND CONTRACTORS
SRISHTI INFRASTRUCTURES LIMITED
Mathra Dass Ahuja and Sons
MAHINDER PAL CONSTRUCTIONS PVT LTD
Pooja Singla Builders And Engineers Pvt Ltd
M P TYAGI ENGINEERS AND CONTRACTORS
Ktech Engineer Builders Co. Pvt. Ltd
Global Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid