Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-Finance | L1 | Accepted-Finance Lowest Quoted | |
| 2 | L2₹29.5 L+₹28,954.25 (0.99%)Rejected-Finance | L2 | Rejected-Finance Highest Quoted |
Tender Value
₹35 L
EMD Value
₹35,000
Closing Date
12 Mar 2024, 3:00 pmClosed
THE COMMISSIONER
Salem City Municipal Corporation, Fort Main Road, Salem
Maintanance and repairs to the Kitchen room Toilet Block, Compound wall and ICDS Centre at Manakadu Kamarajar Girls Hr.Sec.School in Division no - 12 Zone II.
2024_MAWS_442202_1
E6/509/B/2023-2024
Open Tender
Civil Works
Lump-sum
90 days
Salem City Municipal Corporation
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹35,000
22 Mar 2024
6 Mar 2024
12 Mar 2024
6 Mar 2024
12 Mar 2024
6 Mar 2024
Amount
Dismantling the Existing damaged Reinforced Cement Concrete including all cost and conveyance etc., complete
Dismantling the Existing damaged Brick Work in Cement morter including all cost and conveyance etc., complete
Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales murams and ordinary gravel and hard dravel including shoring, strutting, baling or pumping out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick and depositing the surplus earth at places as directed by the departmental officers with initial lead and lift
a). Narrow Foundation
b). Open Excavation
Collection,supply and filling of sand from approved quarry to work site and stocking to the Departmental gauge for premeasurement as directed by the Departmental Engineer, to required depth not more than 15cm depth including cost and Conveyance of sand to site and all labour charges for filling etc., Complete complying with Standard Specification
Plain cement concrete 1:4:8 mix (One cement four sand and eight aggregate) using 40mm size ISS gauge HBBG metal including mixing, laying, consolidating, curing, cost and conveyance of all materials to site and all labour charges etc., complete
Supplying and errecting centering to sides and soffits including supports and strutting for drainage sides and culvert body wall sides using M.S Sheets of size 90cm x 60cm and B.G 10stifened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding laid over (silver oak joists) of size 10cm x 6.50cm spread at about 90cm including all labour charges and cost and conveyance of all materials to site etc. complete
a). Square Columns/ Sunshade,Lintel
b). Grade Beam
c). Plain Surface
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Reinforced cement concrete 1:1½:3 mix (One cement one and half CS sand three aggregate) using 20mm ISS gauge HBBG metal from the approved quarry including mixing, laying, consolidating, curing cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification
a). Foundation & Basement
b). Ground Floor
Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm (8 3/4" x 41/4" x 23/4") from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications
a). Foundation & Basement
b). Ground Floor
Collection,supply and filling of Well gravel from approved quarry to work site and stocking to the Departmental gauge for premeasurement as directed by the Departmental Engineer, to required depth not more than 15cm depth including cost and Conveyance of gravel to site and all labour charges for filling etc., Complete
Supplying and fixing MS grill to doors windows and ventilators etc. as directed by the departmental officers inclusive of cost of MS grill and labour charges including one coat of red oxide and fixing in position etc. complete
Supplying and fixing in position of 20 BWG GI plain sheet shutter door of size 70 x 160 cm framed with alround MS angle iron of size 30 x 30 x 5mm with one ledge and two braces made out of MS flat 30 x 5mm size without door frame but with necessary gudjin pins and locking arrangements on both sides complete. The 20 BWG GI plain sheet should cover the MS angle frame alround in such a way that there would not be any exposition of the angles to avoid any rusting. The fastening of the GI sheet with the angle iron frame must be with aluminium rivets at 25cm C/C. The entire shutter door must be painted with one coat of red oxide paint and the shutter properly fixed in position etc., complete - Each
Manufacturing,supplying & fixing in position Steel windows of MS sheet 20 gauge thick with openable shutter frame and shutter frame made out of steel section confirming to IS 7452/ 1990.The outer frames of windows made of Z section (F7D) of size 25 x 20 x 3 mm confirming to IS7452/1992 mullions are made of (F4B) of section size 46x25x3mm confirming to IS7452/1990.The shutters are individual and each of them can be operated separately. Sash bars are made of 'T'section (T2) of size 25x22x3m, 2nos of sturdy hinges and one numbers of handle cum slatch of special type are fixed for with openable shutter. Suitable opening is left for its any operation. One number of adjustable stay with locking bracket of sufficient length shall be provided for each shutter 4 nos. of 40x40x3mm anngle hold fast 230mm length are welded to the outer frame at appropriate point.M.S square bars of 12mm size is welded to the inner face of the window at equal intervals not excluding 10cm spacings ,20gauge MS sheet is used for covering the shutter. Grill members are painted with one coat of primer. Also rate is inclusive
Special Ceiling Plastering for RCC slabs and beams with cement mortar 1:3 mix 10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications.
Plastering with cement mortar 1:3 mix 20mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications.
Plastering with cement mortar 1:5 mix, 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications
Weathering course over roof slab using 20 mm size brick jelly mixed with pure slacked lime no sand to be used the proportion being 32:121/2 including cost and convenience of all materials to working site, well beating with wooden beaters giving necessary slope and thickness including finishing neatly etc.
Finishing the top of roof with one course of Solar Roof Top of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Flooring with Vetrified flooring tiles of size 600 x 600 x 8mm of approved colour and quality of required size laid in cement mortar 1:3 mix 20mm thick and pointing with the same mortar complete and finish very neatly etc complete
Flooring with ceramic tiles of approved Colour and quality of size 305mm x 305mm x 6mm laid first quality design of all colours in cement mortar 1:3 mix, 20mm thick and pointing with the same mortar etc., completely and finish very neatly
Dadooing the walls with Vetrified tiles of size 600 x 600 x 8mm thick laid in cement mortar 1:2 mix 10mm thick and pointing with white cement using 0.40 kg./cm2 including finishing the joint and pointing flush with tile surface etc.
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
Painting two coats with best synthetic enamel paint of approved Colour for new iron works the rate is inclusive of all materials, brushes and scaffolding charges etc., complete complying with standard specification(paint should be got approved by the Departmental Engineer befor use on work.
Providing and laying of Rubber Moulded Hydraulic Pressed Paver Block size 63mm thick in uniform shape of approved make to be laid in lorrying bone pattern with approved non sticking surface in the top and the rate including leveling the base, preparation of sub base with sand cushion 100mm thick, laying out the pavement, cut the pieces to fit the edge, vibrating the pavers, sweeping the sand grouting, providing transporting, loading unloading and laying of paver block as per standard specification.
Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathedCu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For electronic regulator). (SD-23)
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x l00 x for open PVC plug point.inter locking CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for PVC Plug Point (SD-36)
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point. (SD-39)
Supply and fixing of single box type 4'x18w crystal glass LED Tube light with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. (SD-88)
Supply and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1meter down rod on the existing clamp. (SD-107)
Supplying and fixing in position P.V.C. specials such as plain bend, door bend, plain tee, door tee, offsets,Y-junction, plain or with door of various sizes best quality confirming to I.S.S and providing leakproof joints including fixing to wall and giving connection to the P.V.C, soil stacks, dismadling the brick masonry or R.C.C. floor or Roof slab and redoing the dismandled portion to original condition etc., complete complying with standard specifications. As per IS 4985 / 2000 and IS 10124 / 1982 Part II
110mm Dia PVC Pipe 6 Ksc (IS 4985 / 2000)
110mm Dia PVC Elbow (IS 10124 / 1982)
110mm Dia PVC Tee (IS 10124 / 1982)
20mm GI Pipe
20mm GI Bend
20mm GI Elbow
20mm GI Coupling
Brass Chromium Plated Screw Down Tap 15 / 12mm dia (Heavy Type)
1000 Lit HDPE Tank
Hayagreeva Earth Movers
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .