Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.5 LAccepted-AOC NO 41 KANNUDAYAMPALAYAM PUNJAI KALAMANGALAM ERODE 638 153 | ERODE | TAMIL NADU | 638153 | L1 | Accepted-AOC Lowest One | |
| 2 | L2₹70.8 L+₹23,573.64 (0.33%)Rejected-AOC NO 1 INSPECTOR QUARTERS TSP 6TH BATTALION CAMPUS NEW NATHAM ROAD MADURAI 625 014 | MADURAI | TAMIL NADU | 625001 | L2 | Rejected-AOC Second Lowest | |
| 3 | L3₹76.3 L+₹5.8 L (8.22%)Rejected-AOC NO 3 48 BOOMINAICKENPATTY POST OMALUR TALUK SALEM 636 304 | SALEM | TAMIL NADU | 636304 | L3 | Rejected-AOC Third Lowest | |
| 4 | L4₹78.6 L+₹8.0 L (11.4%)Rejected-AOC COIMBATORE 641015 | L4 | Rejected-AOC Fourth Lowest | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance T V MALAI | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹51,500
Closing Date
16 Jul 2024, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Special repair works for existing 1No.of DSP, 2 Nos. of INS, 5 Nos of SI and 71 Nos of PC/HC quarters at Udumalpettai in Tiruppur District.
2024_TNPHC_460193_1
SE/NC/DB/1436/2024
Open Tender
Civil Works
Lump-sum
90 days
Udumalpettai in Tiruppur District.
Refer the Tender Documents
7 documents required · 7 mandatory
₹0
₹51,500
17 Aug 2024
5 Jul 2024
18 Jul 2024
5 Jul 2024
16 Jul 2024
5 Jul 2024
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.5 : Earth work excavation in all soils for open foundation(excluding refilling) a. 0 to 2 mt.
1.6 : Earth work excavation for Open foundation (excluding refilling) width upto 1.25m for drains a. 0 to 2 mt.
30 : Ellispattern
31 : Weathering couse
37.1 : White washing 3 coats (slaked)
41 : Painting - New "iron work"
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
c. 20 mm dia
ANNEXURE 3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 :Plain cement concrete 1:2:4 using 20m gauge hard broken stone jelly (using crushed stone sand)
3.3.2 : P.C.C. 1:8:16 using 40 mm broken brick jelly (using crushed stone sand)
6.2.1 : Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
10.2.1 : Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) (using crushed stone sand) a. In Foundation and basement
e. In Third Floor
14.1.II : Precast Cupboard slab 40mm tk. using standardised concrete mix M20 (Using crushed stone sand) e) In Third Floor
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) Mixed with Super Plasticiser
32.1.1 : Finshing the top of Terrace floor with Pressed tiles (23cmx23cmx20mm) mixed with Water proofing compound (using crushed stone sand)
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) Mixed with Super Plasticiser
34.1: Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) Mixed with Super Plasticiser
35.1.1: Plastering with CM 1:3, 12mm with WPC (using crushed stone sand) Mixed with Super Plasticiser
35.1.2: Spl. Ceiling plastering in C.M. 1:3,10 mm tk.(using crushed stone sand) Mixed with Super Plasticiser
38.7 : Two coats of Plastic Emulsion PAINT including primer
43.1 : Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.6.1 : Precast slab 50 mm tk.in C.C. 1:3:6 with fibre (using crushed stone sand)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - G.F. (using crushed stone sand)
56.4.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F. (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm dia UPVC Non Pressure pipe
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
77.5 : Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
ANNEXURE II A1:Dismantling the damaged brick works of cement mortar for the under 3m Height in all floors without affecting the adjacent structures including the cost of required tools and plants and scaffolding, if necessary and clearing the debris away from the site etc., all complete
A2:Dismantling of Floor finishing and dadooing walls in cement mortar with mosaic tiles / glazed tiles / Cuddapah slabs, clearing the debris away from the site etc., all complete
A3: Clean removal of the old cement plastering both inside and outside from the existing walls of brick masonry without damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant and necessary scaffolding if necessary etc., all complete
A4: Dismantling the existing damaged R.C.C 1:2:4 Cover slabs ( one of cement, two of Crushed Stone Sand and four of HB stone jelly ) with out affecting the adjacent structures, including the hire charges of tools and plants, and scaffolding if necessary, and clearing the dismantled materials away from the site etc., all complete
A5: Dismantling the damaged Pressed tiles laid over cement mortar and Weathering Course lime concrete without affecting the adjacent structures in all floors including the cost of required tools and plants and clearing the debris away from the site etc., all complete
A6:Pointing the Disturbed Pressed Tiles in C.M 1:3 (One of Cement and three of Crushed Stone Sand) 20mm thick for full depth of tiles including curing and racking out the joints of 20mm deep and disposing the debries away from the site etc.,
A7:White washing two coats for old walls using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding, thorough scrapping and washing with soap, soda water etc., complete in all respects
A8: Painting the old wood work with two coats of approved Ist class synthetic enamel paint including clean removal of old paint using Sand paper etc., complete in all respects
A9: Painting the old iron work with two coats of ready mixed first class synthetic enamel paint of approved quality and brand including clean removal of old paint etc., complete in all respects
A10: Painting the old walls with two coats of Oil Bound Distemper of approved brand over existing thorough scrapped wall surfaces including cost of paints, putty, brushes, watering, curing, thorough scrapping, clean removal of dirt and dust etc ., all complete
A11 :Painting the old walls with two coats with ready mixed Plastic Emulsion Paint of first class quality paint of approved colour and shade over a priming coat, including thorough scrapping, clean removal of dirt and dust etc., complete
A12: Run off the 2 wires of 4sqmm copper PVC insulated single core cable with one run of 7/20GI stay wire suspended with porecelin reel insulators at 1.0m centre to centre for support of phase and neutral cable from top of street pole to the house / flats including all materials etc... all complete for EB service connections including labour charges for fixing GI wire and MS angles (For EB Service connection single phase)
A13: Supplying and fixing of 4' long 18 Watts LED tube light with fittings
A14 :Supplying and fixing of 9 Watts LED bulbs
A15: Supplying and fixing of 12 Watts LED bulbs.
A16: Supplying and fixing of Bulk head fittings suitable for 12W bulb.
A17: Supplying and fixing of 25 Watts LED Street light .
A18: Removing and redoing of new Ceiling rose fittings including labour charges for fixing of etc.,
A19: Removing and redoing of new Batten type holder fittings including labour charges for fixing of etc.,
A20: Removing and redoing of new 5 Amps Flush type switch fittings including labour charges for fixing of etc.,
A21: Removing and redoing of new 5 amps 5 pin Plug socket fittings including labour charges for fixing of etc
A22: Removing and redoing of new 3mm thick Laminated Hylem sheet fittings including labour charges for fixing of etc.,
A23: Removing and redoing of new 5 " Butt Hinges fittings including labour charges for fixing of etc.,
A24: Removing and redoing of new 10"X5/8" ALU. ALDROP fittings including labour charges for fixing of etc.,
A25: Removing and redoing of new 6"X1/2"ALU. TOWER BOLT fittings including labour charges for fixing of etc.,
A26: Removing and redoing of new Door stoper Tfittings including labour charges for fixing of etc.,
A27: Removing and redoing of ALU.HANDLE WITH C.P.SCREWS Tfittings including labour charges for fixing of etc.,
A28: Removing and redoing of new 3 " Butt Hinges fittings including labour charges for fixing of etc.,
A29: Removing and redoing of new 4"X5/8"ALU. TOWER BOLT fittings including labour charges for fixing of etc.,
A30: Removing the damaged broken door / window / ventilators including the removal of frames, hinges, fastenings and shutters form the existing structure and stacking the same carefully for reuse if any
A31: Supplying and Fixing of SFRC Manhole cover of Heavy including labour charges for fixing in position etc., all complete a) 0.75M X 0.75M
A32: Supplying and fixing of 3mm thick pin headed Glass panels with aluminium anodised ‘U’ shape beeding of size 12x12mm with 107 gram in average weight for 1m length with aluminium bolts and nuts for the shutters of the steel windows already supplied to suit all the size
M K SARAVANAN (BID ID -1080066)
M Prabhu (BID ID -1084109)
M/s.V.S.D CONSTRUCTION (BID ID -1084048)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_547029.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .