Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC LOWSET | |
| 2 | L2₹19.2 L+₹2.8 L (17.0%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹19.4 L+₹3.0 L (18.3%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹22.2 L+₹5.8 L (35.2%)Rejected-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹25.5 L+₹9.0 L (54.9%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Feb 2023, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD
REPAIR/MAINT OF SECURITY LIGHTS AND GARDEN LIGHTS, SOLAR LIGHTS AT DOMESTIC AREA AND REPAIR / MAINT LIGHTENING PROTECTION, LIGHTNING CONDUCTOR AND EARTHING OF BUILDING AT MANKHURD UNDER GE(NW) MANKHURD
2023_MES_579026_1
8216/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW) MANKHURD
₹60,000
Yes
3 Apr 2023
4 Feb 2023
27 Feb 2023
4 Feb 2023
24 Feb 2023
9 Feb 2023
Amount
Excavation in trenches not exc 1.5 mtr wide & n.exc 10 sqm cm on plan and not exc 1.5 mtr in depth and getting out in soft / loose soil
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC. Note : Sand after punning down will be measured
Supply and laying precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.. Make - Methab Indore Tiles or Conforming to IS Marked.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flate size 250mm x 150mm x 40mm laid cable cover obtained shall be reused.
Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armored heavy duty aluminum conductor LT 1100 Volts grade of size 3.5 Core 25 Sqmm, fixed on pole, wall and laid in trenches etc after disconnecting Note - Excavation and earth work will be mesured and paid seprately.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size:3.5 core 25 Sqmm
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS/ BENLO
Supply and Laying or fixing or passing through pipe, XLPE insulated ISI marked, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required including disconnection/taking down of existing cable all as specified. Make: Polycab/ Havell's/ KEI/ Gloster
-Ditto- all as per item No 10 above here-in-before but 10 Sqmm 4 Core complete all as specified & directed. Make: Polycab/ Havell's/ KEI/ Gloster
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. Make: PAINT: ASIAN/ NEROLAC/ BERGER
S& F in replacement of GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x 5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge. Make: PAINT: TATA/ JINDAL/ ZENITH
S& F in replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cable protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge. Make- TATA/ JINDAL/ ZENITH
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge..
M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing watering finish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top', including removal of surplase soil all as directed.
S&F of HDPE pipe 75 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etcall as directed by Engr-in-Charge. Make: SUDHAKAR / PRAYAG
Dismantling and disconnecting the electric connections and taking down the following burnt / unserviceable MCCB from panel boards of any capacity all as specified and directed by Engineer –in –Charge.
M&L in repairs MCCBs 3 Pole 250 Amps,36 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELL'S/ C&S
M&L in repairs MCCBs 3 Pole 200 Amps,36 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELL'S/ C&S
M&L in repairs MCCBs 3 Pole 100 Amps,16 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELLS/ C&S
M&L in repairs MCBs FP 16 amp to 63 Amps,16 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge. Make: HAVELL'S/ SCHINDER/ LEGRAND
M&L in repairs for 24 Hrs 240 V FM1 Quartz type daily timer switch for controlling street lights contactors all as specified and directed by Engineer –in –Charge. Make : L & T/ Indo Asian/ C&S
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
S&F in repair of building Security light fitting made up of pressure die cast alluminium body with mid power 60 Watt LED luminaire, with IP 66 protection, 4 KV in-built and 10 KV external large protection having luminuous efficiencies not less than 110 lm/watt CCT 5700K as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge.Make : Bajaj/ Wipro / Havells /Jaguar /Benlo
S&F in Repairs 36 W LED recessed full lit lminaire with glare free niform illumination with longer life and less maintainance 2x2 fitting mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement all as specified and directed in EIC. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using comutrised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately. (ii) Cable joint will be measured and paid seperetely. (iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed.
Supply and Fix in repairs MCCB 100 Amps 4 pole, 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted 0n wall with base plate for mounting in panel, including taking down of old MCCB with enclosure and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
Supply, install, in repair/ renewal feeder piller box outdoor type, IP-54 protection CPRI approved, factory fabricated, cubical panel wall mounted, self supported, free standing type, made out of 3.15m thick CRCA sheet with locking arragement, suitable for 3 phase, 4 wire, 415 volt, 50HZ, AC supply including suitable size copper conductor control wiring and powder coating with connecting the cables with necessary cable glands, lugs etc proper arrangement for veritilation complete with and including the following accessories :- (i) Copper bus bar Phases & Neutral for 200 Amps- 01 set (a) MCCB 4 pole 25 KA 100A - 1 Nos (b) MCB TPN 40 Amp 10 KA- 01 Nos (c) MCB SPN 32 Ampc 10 KA - 01 Nos
Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
M&L for earthing complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materils
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
S&F GI 32x6 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in pipe, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
S&F copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
Suppli and fix in repairs Halogen lamp with fixture complete of capacity 500/ 1000 watt operating on 230v, single phase, AC, 50 Hz supply complete all as specified and directed.
M & L for Taking down of aluminium/copper strip of any size laid as roof conductor, down conductor, earth contunity conductoor including air termination rod from any position / location of sheds/ buildings of height up to 30 meter & refixing the same after straightning the conductor/removal of bends, including replacing the old insulators with new one and saddles all as directed at site Note -i) The quoted rae is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. ii) The raete is deemed to be inclusive for providing Procealin insulator, Galvanised screws, Plugs iii) PCC Block required shall be measure and paid under respective items
S&F aluminium earth strip as roof/down/earth contitunity conductors of size 25x3mm with saddles, insulators, screws, etc to / at any position / location of sheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note -i) The quoted rate is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. ii) The rate is deemed to be inclusive of Procealin insulator, GI screws, Plugs iii) Space of insulator support shall not be more than 30 cm on roof / wall and 70 cm if insulator is placed over PCC block.
Refixing of Alluminium roof conductor/ down conductor including Air termination rod including provision of new insulator (procelain type) support, GI screw and all connected item complete all as specified and directed.
S&F air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary terminal base plate of not less than 3 mm, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick shheet for fixing the block
M&L for pre-cast cement concrete block of size 0.15M x0.15M x0.15M for fixing of Aluminium strip type C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the coccrete block on terrace of bldgs of height up to 30 meter all as directed at site Note -i) The quoted rae is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter.
Dismantling of PCC foundation / pole coping from ground level all as per specified.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 12 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make: Bajaj
Preparing surfaces of steel tubular swaged pole LT with scraping out old paint by emmery paper, wire brush complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint background and stripping with black and yellow synthetic enamel paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and remove the carbon after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LED will be measured and paid separately on respective item of Sch 'A' here-in-after].
Dismantling complete old Bolard light fitting and Supply & Fix 8/9 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3 Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry complete. Make:- Havells / Bajaj/ Crompton/ Jaguar/ Benlo
Supply and fix in repairs flood light luminaire with polycarbonate optics pressure die cast housing IP 66 ingress protection, 4 KV in-built and 10 KV external SPD, having efficiency not less than or equal to 150 lm/watt, CCT 5700oK in buildings etc the fitting shall be of LED type 150 Watts complete all as specified. Make : Bajaj/ Jaguar/ Wipro/ CG/ Benlo/ Jaguar
Supply and fixing Post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. Make:- Bajaj/ Havells / Benlo/ Crompton/ Jaguar/ Wipro
Supply and fixing Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. Make:- Havell's/ Crompton/ Jaguar/ wipro
S & F in repair/replacement of LED Driver 60 to 70 Watts Suitable for street light fitting. Make: Crompton /Havells/Bajaj
S & F in repair/replacement of LED Driver 30 to 40 Watts Suitable for street light fitting, Make : Crompton /Havells /Bajaj
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 25 to 50 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 120 to 185 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M
S & F in repair analog time switch FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY). Make L&T/ C&S
S & F in repair 3 Pole power contactor MNX-18 of coil voltage 415 Volts Make-L&T/ C&S
S & F in repair spare coil for MNX-18 3 pole power contactor of 415 volts Make L&T/ C&S
M & L for depute service representative to attend the LED Solar Light fittings of 18 wattage once in a month . Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd for 26 fittings per month a)Solar PV Modules - Check the Circuit Voltage and current characteristics. Also, check the mechanical integrity of the Solar PV Modules. b)Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. Note:- Electrolyte solution will be measured seprately under this Schedule. c)Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring. d)Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed. e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering ifa any required f)Module Cleanliness - Cleaning of the dust accumulated over the Solar Module, and taking corrective measures
M&L for preparation of old painted surfaces of Solar Street Light Poles including acessories by scarping old paint and applying two coats of paint including numbering of pole with black synthetic enamel paint all as directed by Engineer in Charge. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market
Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar
Supply and fix inreplacement of low maintenance VRLA lead acidic battery of 120 AH suitable for 1 x 18 watt Soalr Light fitting all as per recommanded by Manufracturer
Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required
Supply only electrolyte solution to be incorporated in servicing, suitable for Solar charged battery of any capacity. Note 2 : A sum of Rs 62,040.00 towards sch of credit shall be deducted to arrive the contract sum.
R J ENTERPRISES
Shree Ayyappa Engineering
PRIME ENGINEERS
AM ENTERPRISES
M/s Bhagirathi Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .