Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.7 LAccepted-AOC HARIPUSHPA APARTMENT BUILDING NO E 1 FLAT NO 01 REST CAMP ROAD DEOLALI CAMP 422 401 | DEOLALI CAMP | NASHIK | MAHARASHTRA | 422401 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.2 Cr+₹21.6 L (22.7%)Rejected-Finance 6 SAI KRUPA SONAWANE PARK BEHIND TILAK NAGAR BUS STOP OZAR MIG NASHIK 422206 | NASHIK | NASHIK | MAHARASHTRA | 422206 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.2 Cr+₹25.2 L (26.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
31 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Nagpur
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
IMPROVEMENT TO LIVING IN AIRMEN ACCN AT 25ED DEVLALI
2025_MES_704802_1
80693
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Ojhar
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) Ojhar
₹2.2 L
Yes
18 Jul 2025
19 Apr 2025
2 Jun 2025
19 Apr 2025
31 May 2025
12 May 2025
Amount
Excavation in trenches n . exc 1.5 m wide and n. exc 1.5 m in depth; for foundation etc. or for shaft, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n exc 1.5 m in depth and getting out any type of soil deep and getting out in any type of soil. complete all as specified and directed.
Surface excavation n. exc 30cm deep and getting out in hard dense soil complete all as specified and directed.
Returning filling including spreading, leveling, watering and wello ramming in layers n exc. 25 cm complete all as specified and as directed.
Removing excavated material n. exc 50 Mtr and depositing, where directed at a level n.exc 1.5 Mtr above the starting point complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40mm stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour brick work with fly ash bricks (FASB) conferming to IS 12894, of strength M-10 straight or curved on plan exc 6m mean radious built cement mortar 1:4 complete all as specified and directed.
Supply and fix 15 mm bore galvanised mild steel tubing of medium grade with all fittingSupply and fixixed complete to walls & ceiling or laid in trenches/floors etc complete all as specified and directed. Note:- Rate included for chase cutting in stone/ brickmasonary purpose of concealed GI tubing
Supply and fix 20 mm bore galvanised mild steel tubing of medium grade with all fittingSupply and fixixed complete to walls & ceiling or laid in trenches/floors etc complete all as specified and directed.
Material and labour renderig 15mm thick in cement mortar 1:6 over fair faces of of brick or concrete surface of wall rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
Material and labour renderig 15mm thick in cement mortar 1:4 over fair faces of of brick or concrete surface of wall rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
Material and labour Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Material and labour Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for 75mm thick cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of walls complete all as specified and directed.
Material and labour for preparation of new plastered surface and applying two coat of oil bound distemper on walls over a coat of 1mm thick putty complete all as specified and directed.
Material and labour for coloured non skid ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor, over and including 15mm thick screed bed or bedding layer in cementy mortar 1:4,etc complete all as specified and directed.
Material and labour for glazed coloured ceramic tiles 300 x 600 x 10 mm thick for work on vertical surface such as skirting, dado, set & jointed in cement slurry and pointed in white or coloured cement to match the existing wall surfaces, over and incl 10mm thick rendering in cement mortar 1:4 etccomplete all as specified and directed.
Supply and fix PVC (SWR) pipes 110mm dia single sockted in any length with rubber ring joints laid in trenches complete all as specified and directed.
Supply and fix PVC (SWR) bends 110mm bore of any radious complete all as specified and directed.
Supply and fix PVC (SWR) junction single ,(single T) equal or unequal 110mm bore complete all as specified and directed.
Supply and fix PVC(SWR) vent cowl 110mm complete all as specified and directed.
Supply and fix PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints laid in trenches complete all as specified and directed.
Supply and fix 75mm bore CI floor trap complete all as specified and directed.
Material and labour PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Supply and fix 30 mm thick flush shutters, solid core construction , with block board core and plywood face panels, commercial type on both sides etc complete all as specified and directed.
Material and labour 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints,complete all as specified and directed.
Material and labour 125mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
Supply and fix aluminium anodised barrel tower bolts of extruded section and fixed fixed 200 mm long etccomplete all as specified and directed.
Supply and fix aluminum handles cast type anodized 150 mm size etc complete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy.
Material and labour two coat synthetic enamel paint over one coat of red oxide primer on new steel surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and directed.
Material and labour for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection /path finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for cement concrete type B-1 ,1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Material and labour reinforcement cement concrete type B1 (1:2:4) using 20mm graded stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and labour formwork to sides and soffit of roof beams ,lintel level shelves incl supports over hang etc rough finished surfaces of concrete flat complete all as specified and directed.
Supply and fix Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply and fix mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Material and labour Reinforcement cement concrete M-25 ( Design mix) as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, ladings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete ( flat ) complete all as specified and directed.
Supply and fix 1000 litre capacity of rotational moulded polyethylene water storage tank multilayered construction, ISI marked of make specified (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Supply and fix 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Supply and fix 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. .(Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm etc complete all as specified and directed.
Supply and fix vitreous china squatting pan 'ORISSA PATTERN ' size 580mm x 440mm 'white with integral foot rest (excluding flushing cistern and flush pipe ) with 'P' or 'S' trap, front or back inlet including connection to trap and to flushing pipe anti syphonage pipe etc complete all as specified and directed.
Supply and fix in repair vitreous china wash down water closet (Pedestal) including white PVC seat cover closed pattern with flat bottem and cover and mild steel chromium plated hinge device,connection to drain or outgoing pipe and to flushing pipe, antisyphonage pipe joint to socket or stoper etc, white (EWC) complete all as specified and directed.
Supply and fix Vitreous China Ware Wash hand basin white, flat back, size 450 x 300 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand and waste pipe complete all as specified and directed.
Supply and fix 10 ltr capacity PVC low level flushing cistern white, ISI marked make as specified with inlet, float valve and handle including breacket with 32mm dia PVC pipe 600mm long complete all as specified and directed
Supply and fix PVC connection 15mm dia with Brass nuts of length 450mm etc complete all as specified and directed.
Supply and fix 15 mm bore angle stop cock long thread fancy type chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle screwed both and for iron pipe or for union and fixed etc complete.
Supply and fix 15 mm bore bib taps long body chromium plated fancy type, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for unions and fixed 15 mm bore etc complete all as specified and directed.
Supply and fix pillar taps, Cast Copper alloy, with capstan heads, chromium plated, fency type screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
Supply and fix towel rail 450mm long of PTMT fixed with an dincluding cromium plated brass screws and wooden/plastic cleats (minimum weight 170 gms) ccomplete all as specified and directed.
Supply and fix Soap dish any type , fixed to plugs with chromium plated brass screwes complete all as specified and directed.
Supply and fix painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix Roof trusses (framed),tubuler trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (tubes, Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe-290 Gde E-165 complete all as specified and directed.
Supply and fix for mild steel plates , plain , of any thickness square cur or notched including forming holes as required at site and including welding if required and complete all as specified and directed.
Supply and fix Mild steel screw bolts (machine made) with hexagonal at one end and screwed the other and grouting in PCC block including nut and washers etc complete all as specified and directed.
Supplying, laying, jointing and testing salt glazed stone ware drain pipe grade ‘A’ laid in trenches and jointed in cement mortar 1:1 complete all as specified and as directed for 150mm internal dia of pipe complete all as specified and directed.
Material and labour cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for 150mm internal dia of pipe complete all as specified and directed.
Material and labour PCC 1:3:6 Type C-1 using 20 mm graded stone aggregate as in coping/ surface channel / drains complete all as specified and directed.
Material and labour precast re-inforced cement concrete 1:2:4 type B1 (using 20 mm graded stone agg) as in cover slabs for man holes etc set in cement mortar 1:6 including necessary form work complete all as specified and directed.
Excavation over areas not exceeding 1.5M depth and getting out in Hard/ dense soil all complete all as specified and directed.
Supply and fix Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed uard bars; barred iron doors; ladders; ramed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Material and labour 100 mm dia, Cast iron soil, sand cast waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed.
Material and labour for 100mm dia, Cast iron cowls complete all as specified and directed.
Material and labour Burnt Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 as in manhole and septic tank etc complete all as specified and directed.
Supply and fix 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing of steel pipe or union complete all as specified and directed.
Supply and fix 15 mm bore stop cock long thread (concealed type) fancy type chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle screwed both and for iron pipe or for union and fixed etccomplete all as specified and directed.
Material and labour Grating square fitting of size 150mm made in two parts for smell and mosquito proofing with minimum 25 mm water seal of PTMT. (Minimum weight 85gms) complete all as specified and directed.
Material and labour two coat synthetic enamel paint over one coat of pink primer on new wooden surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and directed.
Supply and fix Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
Supply and fix Anodised aluminium snap grid frame work size 605x605 mm for false ceiling incl Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Material and labour Non asbestos fibre cement building boards 4 mm thick (one side embosed design), fixed or laid/ inserted to Aluminium grid frame work in ceiling with clips complete all as specified and directed.
Supply and fix Vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
Supply and fix Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
Supply and fix 32mm dia UPVC Low density polyethylene (LDPE) waste pipes of pressure rating 6 kgf/sq. Cm complete all as specified and directed.
Supply and fix hand shower (health faucet) (ABS Chrome palted) with 8mm dia, 1m long, flexible tube with wall hook ccomplete all as specified and directed.
Supply and fix Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Material and labour 20mm thick makrana marble tiles machine cut in urinal partion Fixed in wall jointed with grey cement slurry including cutting and polishing complete all as specified and directed.
Excavation over areas exceeding 1.5M depth and getting out in Hard/ dense soil all as specified. complete all as specified and directed.
Taking down carefully existing tarfelt, plaster or concrete bedding upto the RCC slab of any description over the surface of roof ,terraces including flashing and junctions of parapet/curb walls etc including removing off rubbish , material to a distance exceeding 250m but not exc500m and depositing complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any description and in any position not other wise specifically provided for complete all as specified at site complete all as specified and directed.
Material and labour for plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed.
Material and labour 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed. Note :- Water proofing compound shall be measured separately as supply only in item no 14
Material and labour One coat of bituminous based primer conforming to IS-3384-1965 @ 0.3 Kg/Sqm to be applied on prepared surface, till the surface is properly impregnated complete all as specified and as directed.
Material and labour APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application with solar reflective bituminous aluminium paint @ 0.10 kg/sqm complete all as specified and as directed.
Taking down 15 mm bore steel tubing and connection including cleaning and refixing or removal to store etc complete all as specified and as directed.
Supply and fix 20 mm bore galvanised mild steel tubing of medium grade with all fittingSupply and fixixed complete to walls & ceiling or laid in trenches/floors etc complete.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each etc complete.
-do- but exc 1.5 Sqm and n exc 4 sqm each.
Taking down shutters of any description exc 1 sqm but not exc 2 sqm each removal to store.
Dismantling/demolition of existing water tanks of steel /PVC/RCC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc incl racking out joints hacking for key and scrabbing down with water etc.
Material and labour renderig 10mm thick in cement mortar 1:6 over fair faces of of brick or concrete surface of wall rendering is to be finished even and smooth without using extra cement
Material and labour renderig 5mm thick in cement mortar 1:3 on ceiling surface and finished even and smooth with out using extra cment
Material and labour preparing surfaces of wall by complete removal of existing treament and applying two coat of oil emulsion distemper on walls over a coat of 1mm thick wall care putty complete all as specified and as directed.
Material and labour for preparation of new plastered surface and applying two coat of oil bound distemper on walls complete over a coat of 1mm thick wall care putty all as specified and as directed.
Material and labour for preparation of new plastered surface and applying three coat of white wash on ceiling complete all as specified and as directed.
Material and labour for complete removal of existing treament on ceiling and applying two coat of white wash all as specified and as directed.
Demolition of Brickwork of stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articlesl etc complete.
Material and labour Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, 20mm as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed
Material and labour Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:3 complete all as specified and directed
Material and labour two coat synthetic enamel paint over one coat of pink primer on old wooden surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and directed
Material and labour for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, over and including 15mm thick screed bed or bedding layer in cementy mortar 1:4, over 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) etc complete all as specified and directed
Material and labour for machine cut kota stone slab 20-25 mm thick, in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete,incl 10mm thick rendering on wall or conc surfaces in cement mortar 1:4 complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Material and labour for coloured joint free glazed ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor, over and including 15mm thick screed bed or bedding layer in cementy mortar 1:4, over 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) etc complete all as specified and directed
Material and labour for non skid coloured joint free ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in skirting/dado etc. set and jointed in neat cement slurry and pointed in colour cement to match to floor, over and incl 10mm thick rendering on wall or conc surfaces in cement mortar 1:4 ,complete all as specified and as directed.
Supply and lay in trenches/floor/on wall/ on surface with necessary fixing accesseries LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty)1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements all as specified and directed. Make :- Polycab/Havells/Gloster/KEI
Supply and lay in trenches/floor/on wall/ on surface with necessary fixing accesseries LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty)1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements all as specified and directed. Make :- Polycab/Havells/Gloster/ KEI
Material and labour & fixing of DWC pipes it should be flexible & should allow deformation in diameter as well as In joints under external load & soil natural movement, socket & spigot joint with electrometric sealing ring , it should be highly corrosive resistant & it should be impact resistant, chemiacal resistant, flexible & light weight of size 63 mm dia complete with coupler, elbows, joints,& necessary space parts complete all as specified and directed Make :- Dura line/Rex/Aestral/Gemin
Material & labor LT panel/feeder pillar box indoor/outdoor type by cutting corroded MS lid from panel , wielding the same with 3.15 mm thick /MS sheet in any desired including removing the carbonized/melted sparked thimbles cleaning the carbonized bus-bar making cable end clean, wielding/replacement of broken hinges with new one, replacement of locks with new one ( as per requirement) mounted on existing door, including taking elect shut down and cleaning the all bus bar system/providing necessary color code insulations , incoming and outgoing cables, replacement of burnt thimble/ cable pieces by using new thimble, cleaning of MCB/MCCB of size 32 AMP to 100 AMP Qty 5 with blower and charge the electrical panel painted surfaces of outing LT panel including scraping out old paint and painting with two coat of synthetic enameled Siemens grey paint complete all as directed including marking of building number on front face of panel in color compete all as specified and directed.
Supply and fix Sheet Metal enclosure double door for mounting MCBs with 200 A rated bus bar 4 way AC 240 Volt with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge . Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand
Supply and fix in MCB TPN 63Amp. complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead wire 4 mm fixing on wall by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-2 and CI cover with frame all as shown in electrical plate No. 5 of SSR part-I complete all as specified and directed
Taking down carefully old UNSV aluminum/copper point wiring (light, fan, socket power etc) on TW batten/ PVC casing Capping surface steel/PVC conduit excluding all fitting/fixtures and making good disturbed surface of wall/floor/ceiling etc to match the adjoining surfaces.
Point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5 sqmm (nominal area) cable using approved colour code as per IS drawing in and incl incl heavy duty PVC concealed conduit wiring cutting chaser on stone masonry/ brick wall, ceiling, for not less than 25 mm which shall be increased as per site requirement with all accessories suitable for modular type fitment including provision for fixing of modular/non modular flush boxes of suitable size complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 1.5 mm as continuous earth wire connected to common earth dolly complete all specified and marking good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed
One Light point controlled by one switch
One Fan point controlled by one switch
One 3 pint socket out let 5 Amps on same board
One 3 pint socket out let 5 Amps on independent board
One bell point controlled by one bell push
Description all as per Item No 121 above but using 2.5 sqmm copper conductor cable (multi strand) PVC insulated PVC insulated FRLS (unsheathed ) for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green copper conductor cable as continuous earth wire with lugs complete all as specified and directed.
Supply and fix Switch piano flush type single pole one way 5 Amp, complete all as specified and directed.
Supply and fix Switch piano flush type single pole one way 15 Amp, complete all as specified and directed.
Supply and fix Socket out let 2 in 1,5 pin 5 Amp flush type, complete all as specified and directed.
Supply and fix Socket out let 2 in 1,5 pin 15 Amp flush type, complete all as specified and directed.
Supply and fix Bell push flush type 5 Amp, complete all as specified and directed.
Supply and fix Bell, Ding Dong AC 230 Volts single pole. complete all as specified and directed.
Supply and fix fan regulator electronic 5 step type 2 module suitable for 1200/1400 mm sweep fan complete all as specified and directed.
Supply and fix ceiling rose surface type, PVC/Polycarbonate insulated body size 50x28 mm two three terminals complete all as specified and directed.
Supply and fix in lamp holder PVC/Poly carbonate type with back plate suitable for batten fitting SP 230 Volts complete all as specified and directed.
Taking down carefully existing tube light fitting/fixture and making good distributed surfaces of wall/floor/ceiling etc to match athe adjoining surfaces complete all as specified and directed.
Supply and fix LED light fittings fixture 20w, 6500K, 2000 lm decorative ultra slim with co extruded channel in thermal conductive material with plastic housing, heat sink, environmental friendly having power factor > 0.95 surge protection 2.5KV energy ready to use complete all as specified and directed
Refitting of serviceable light fitting any type and wattage obtaining wide item no 13 above complete and connecting up with and including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete all as specified and directed
Dismantling and taking down old US main switches/MCB/DBs enclosure etc any type capacity and making good to the disturbed surfaces of wall complete all as specified and directed
Dismantling and taking down carefully electric meter etc any type of capacity depositing electric meter in MES store and refitting electric meter after completing B&R works including making good to the disturbed surfaces of wall complete all as specified and directed
Material and labour for Submain wiring with two single core PVC insulated flexible copper conductor cable of size 2x4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 sqmm as earth lead in and incl heavy duty PVC concealed conduit wiring cutting chaser on stone masonry/ brick wall, for not less than 25 mm which shall be increased as per site requirement with all accessories and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed Make :- Polycab/Havells/Gloster/ paragon or equilant
Material and labour for submain wiring with two single PVC insulated flexible copper conductor cable of size 4x6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 sqmm as earth lead and incl heavy duty PVC concealed conduit wiring cutting chaser on stone masonry/ brick wall, for not less than 25 mm which shall be increased as per site requirement with all accessories and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed Make :- Polycab/Havells/Gloster/ paragon or equilant
Supply and fix sheet metal inclosure MCB SPN 4 way distribution board 240 volt, double door with DIN rail bus bar, neutral link, earth terminal etc IP-43 protection. complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix sheet metal inclosure MCB SPN 8 way distribution board 240 volt, double door with DIN rail bus bar, neutral link, earth terminal etc IP-43 protection. complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix sheet metal inclosure MCB TPN 4 way distribution board 415 volt, double door with DIN rail bus bar, neutral link, earth terminals etc, IP 43 protection. complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix MCB SP 5 to 32 Amp 240 Volt B sires 10KA complete all as specified and directed by Engr-in-Charge Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix MCB SPN 32 to 40 Amp 240 Volt B sires 10KA complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix MCB SPN 63 Amp 240 Volt B sires 10KA complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix sheet metal enclosure Distribution board 415 volt, vertical TPN 4 way with provision for MCB legrand make or equivalent in as incomer SP/TP MCB’s as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/recess mounting IP-43 K-09 protection. complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Supply and fix MCCB TP 100 Amp 240 Volt B sires 16KA complete all as specified and directed Make Indoasian/L&T/HPL/ ABB/Havells/C&S/Legrand or equilant.
Disconnect & insulate electric supply wire and taking down carefully ceiling fan/Exhaust fan any make any sweep dismantling and including oiling , greasing replacement of cotter pins, painting with one coat of synthetic enamel paint white after cleaning dust/dirt & writing MES No. and hanging/fixing the ceiling fan/Exhaust fan wall fan to its original position with an of 3 core copper conductor cable PVC insulated & sheathed from ceiling from ceiling rose to fan connector including replacement of clamps rubber shackle & top and bottom nut bolt washers complete testing complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead wire 4 mm fixing on wall by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-2 and CI cover with frame all as shown in electrical plate No. 5 of SSR part-I complete all as specified and directed
Supply and fix Exhaust fan 230V 300mm sweep with all connection arrangement & necessary nut bolts etc including wall cutting and making good disturbed surface if necessary & connecting with flexible wire of size 23x0.0076 for connecting up to ceiling rose complete all as specified and directed Make Havells/Bajaj/Usha
Supply and fix street light fittings 35 watt LED energy saving environmental friendly long life versatile die cast housing with toughened glass IP 66 protection, impact resistance of IK 07 & 10 KV external SPD roadway luminaire with high power LED secondary optics and accessories fixed on existing/new GI pipe bracket fixed on building and connection with PVC copper 1.0sqmm 3 core cable etc complete all as specified and directed complete all as specified and directed complete all as specified and directed Make Havells, Phillips, Crompton wipro etc.
Taking Taking out old unserviceable submain wiring of any type and capacity from existing all as per specified and directed by Engr-in-Charge
Supply and fix Electric water heater,storage type with Glass line coated verticle/squre type double safety thermostat – dual overheating control mechanism cuts off power automatically even if primary cut off fails ,Multi-function Safety Valve discharges water and acts as a non-return valve if pressure or temperature guge exceed preset limits, inner tank(with 7 yrs warranty) and heating element upto 2 KW of capacity 25 litre suitable to withstand 8 bar pressure , BEE 5 Star rated,compact cube shape design for smaller bathrooms & weather proof IPX4 steel body, complete with all mounting accessories connection piece hot cold pipes with fixing hexagonal nut bolt washers etc complete all as specified and directed . Make:(Jaquar ERICA VERTICAL (digital) ERD-WHT-V025/Usha /Havells/Bajaj
Supply and fixing ceiling fans complete with blades, down rods, anti suside road, clamps accessories complete with nut bolt, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and lay Pipes galvanized medium class laid in trenches complete including GI fittings 50 mm bore, Supply and fix Gun metal globe or gate valve 50 mm dia with brass gate with iron wheel head, screwed both ends, for iron pipe complete all as specified and directed. Make- Jindal, Tata, Apollo
Supply and lay Pipes galvanized medium class laid in trenches complete including GI fittings 25 mm bore, Supply and fix Gun metal globe or gate valve 25 mm dia with brass gate with iron wheel head, screwed both ends, for iron pipe complete all as specified and directed. Make- Jindal, Tata, Apollo
Supply and fix Gun metal globe or gate valve 50 mm dia with brass gate with iron wheel head, screwed both ends, for iron pipe complete all as specified and directed.
Supply and fix Gun metal globe or gate valve 25 mm dia with brass gate with iron wheel head, screwed both ends, for iron pipe complete all as specified and directed.
Material and labour for Cutting of exisiting DI /GI pipe line 80 to 100 dia for inserting of 50 mm GI pipe with thread, union Tee elbow complete all as specified and directed.
Construction of brick masonry valve pit of internal dimension 60 x 60 x 60 cm depth with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:4:8) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron and 6 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
Note : The amount against Schedule of Credit on Page No. 41 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance.
M/s M R MAHANA (BID ID -3309643)
MS. G.A. CONSTRUCTION (BID ID -3298583)
Bidder Name
M/s M R MAHANA
Vinod Enterprises
MS. G.A. CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .