| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Substantially Responsive |
| 2 | Accepted-Technical | Accepted-Technical Substantially Responsive |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
27 Feb 2026, 12:00 pmClosed
SE AK Singh
Superintending Engineer E/M Circle, P.W.D. Kanpur
The work of Rewiring of Type-D residence no 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25 at Raiganj Colony in District Jhansi.
2026_CEEMP_1118854_1
101C/06-EMC/2025-26, Dated-21-01-2026
Open Tender
Electrical Works
270 days
Jhansi
Please refer Tender documents.
5 documents required · 5 mandatory
₹854
Electrical/Mechanical Division PWD Jhansi
₹2.6 L
Jhansi
27 Feb 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
23 Feb 2026
Wiring for Light Point with 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with Piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm FRLS/HFFR PVC copper conductor single core cable etc. as required.(Group A)
Wiring for Fan and Fresh air Point with 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with Piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm FRLS/HFFR PVC copper conductor single core cable etc. as required. (Group A)
Wiring for Call bell point with 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with Piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm FRLS/HFFR PVC copper conductor single core cable etc. as required. (Group A)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supply and Fixing of brass Angle holder including connection etc. as required.
Supplying and drawing 1 x 1.5 sq. mm size of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (For Inverter Wiring)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing of 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
S/F of 63Amp DP Pole MCB (10KA), C curve Make-Havells or equivalent
Supply and fixing of 5 to 32 amp rating 240/415V, 10KA, C curve SPMCB suitable for inductive load in existing DB complete with connections, testing and commissioning etc. as required.
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
Supply & fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity / transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continuous Operation, Complete in All respect. compelete in all respect. 1200 system lumens, >120 Lm/W, PF>0.95, CRI >70, >300V over voltage protection, 4 KV internal Surge Protection, metal housing with 5 years warrantee
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Submain wiring along with earth wire with the 2 x 1.5 sqmm +1x 1.5 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(for Plug,Computer, Aquaduard,TV point)
Submain wiring along with earth wire with the 2 x 2.5 sqmm +1 x 2.5 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Submain wiring along with earth wire with the 2 x 4 sqmm +1 x 4 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Power Plug)
Submain wiring along with earth wire with the 2 x 6 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(AC and Geyser)
Submain wiring along with earth wire with the 2 x 16 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Brush Less Direct Current (BLDC) Fan without Remote - Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply and Fixing of BLDC Fresh air Fan 200 mm size sweep single phase including cartage and fixing Complete in all respects.Make Havells or equivalent
Dismentalling of old wiring, DBs and other electrical installation.
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.88 MB
Tendernotice_2.pdf
PDF • 0.97 MB
Tendernotice_3.pdf
PDF • 1.00 MB
Tendernotice_4.pdf
PDF • 2.77 MB
BOQ_2079909.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid